Elmo Rletschle V-VC 400, V-VC500, V-VC700, V-VC900, V-VC1100 User Manual

...
4.5 (2)
Elmo Rletschle V-VC 400, V-VC500, V-VC700, V-VC900, V-VC1100 User Manual

Edition: 1.4.2012 · BA 233-EN

Original Operating Instructions

VV-VC 400 | 500 | 700 | 900 | 1100 | 1300

Vacuum pump

V-Serie

V-Series

Drehschieber

Rotary Vane

Table of contents

Table of contents

1

Foreword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.1

Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.2

Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.3

Supplier documentation and accompanying documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.4

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.5

Directives, standards, laws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

1.6

Symbols and meaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

1.7

Technical terms and meaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

1.8

Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2

Safety .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

2.1

Warning instruction markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

2.2

General. .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

2.3

Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

2.4

Unacceptable operating modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

2.5

Personal qualifications and training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.6

Safety-conscious work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.7

Safety notes for the operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2.8

Safety instructions for installing, commissioning and maintenance . . . . . . . . . . . . . . . . . . . . . .

9

2.9

Guarantee conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

3

Transport, storage and disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

3.1

Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

3.1.1

Unpack and check the delivery conditionn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

3.1.2

Lifting and transporting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

3.2

Storage. .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

 

3.2.1

Ambient conditions for storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

3.3

Disposal .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

4

Set up and operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

4.1

Setup . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

 

4.1.1

Data plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

4.2

Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

4.3

Areas of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

5

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

5.1

Preparing for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

5.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

5.3

Connecting pipes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

5.4

Filling with lubricating oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

5.5

Connecting the motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

6

Commissioning and decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

6.1

Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

 

6.1.1

Checking the rotation direction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

 

6.1.2

Setting the operating range (V-VC 400 - V-VC 900) . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

6.2

Decommissioning/ storing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

6.3

Re-commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

2

| www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

 

 

 

 

 

 

 

 

Table of contents

7

Maintenance and repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

7.1 Ensuring operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7.2 Maintenance work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7.2.1 Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7.2.2 Air filtering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7.2.3 Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7.2.4 Oil removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

7.3 Repair/ Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 7.4 Spare parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

8

Malfunctions: Causes and elimination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

9

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

 

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |

3

 

 

Foreword

1Foreword

1.1Principles

These operating instructions:

• are a part of the following oil-flooded rotary vane vacuum pumps, V-VC 400, V-VC 500, V-VC 700, V-VC 900, V-VC 1100 and V-VC 1300.

• describe how to use them safely and properly in all life phases.

• must be available where the equipment is used.

1.2Target group

The target group for these instructions is technically trained specialists.

1.3Supplier documentation and accompanying documents

Document

Contents

No.

 

 

 

 

Operating Instructions

BA 233-EN

Supplier documentation

 

 

Declaration of Conformity

C 0045-EN

 

 

 

 

Declaration of harmlessness

7.7025.003.17

 

 

 

Spare parts’ list

Spare parts document

E 233

 

 

 

Data sheet

Technical data and graphs

D 233

 

 

 

Info sheet

Water vapour compatibility for oil-flooded

I 200

vacuum pumps

 

 

 

 

 

Info sheet

Storage guidelines for machines

I 150

 

 

 

Manufacturer’s declaration

EU Directive 2002/95/EG (RoHS)

 

 

 

1.4Abbreviations

Fig.

Figure

V-VC

Vacuum pump

m3/h

Pumping capacity

mbar (abs.)

Final vacuum, operating vacuum

1.5Directives, standards, laws

See Conformity Declaration

4

| www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

 

 

 

 

Foreword

1.6Symbols and meaning

Symbol

Explanation

 

 

 

Condition, pre-requisite

 

 

####

Instructions, action

 

 

a), b),...

Instructions in several steps

 

 

 

Results

 

 

[-> 14]

Cross reference with page number

 

 

 

Information, note

Safety symbol

Warns of potential risk of injury

Obey all the safety instructions with this symbol in order to avoid injury and death.

1.7Technical terms and meaning

Term

Explanation

 

 

Machines

Pump and motor combination ready to be connected

 

 

Motor

Pump drive motor

 

 

Vacuum pump

Machine to create a vacuum

 

 

Rotary vane

Machine’s design or active principle

 

 

Pumping capacity

Vacuum pump volume flow related to the condition in the suction con-

nection

 

 

 

Final pressure (abs.)

The maximum vacuum that a pump reaches when the suction opening is

 

closed. Given as absolute pressure.

 

 

Permanent vacuum

The vacuum or the suction range at which the pump operates perma-

 

nently.

 

The permanent vacuum or intake pressure is ≥ than the final vacuum and

 

< than the atmospheric pressure.

 

 

Noise emission

The noise emitted at a specific loading given as a figure, sound pressure

level dB(A) as per EN ISO 3744..

 

 

 

1.8 Copyright

 

 

Passing on or copying this document, using and

 

providing information on its contents are prohibited

 

unless expressly permitted.

 

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |

5

 

 

Safety

2Safety

The manufacturer is not responsible for damage if you do not follow all of this documentation.

2.1Warning instruction markings

 

Warning

Danger level

Consequences if not obeyed

 

 

 

 

 

 

 

 

 

 

DANGER

 

immediately imminent danger

Death, severe bodily injury

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

possible imminent danger

Death, severe bodily injury

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

possible hazardous situation

Slight bodily injury

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE

 

possible hazardous situation

Material damage

 

 

 

 

 

 

 

 

 

 

2.2 General

These operating instructions contain basic instructions for installation, commissioning, maintenance and inspection work which must be obeyed to ensure the safe operation of the machine and prevent physical and material damage.

The safety instructions in all sections must be taken into consideration.

The operating instructions must be read by the responsible technical personnel/ operator before installing and commissioning and must be fully understood. The contents of the operating instructions must always be available on site for the technical personnel / operator. Instructions fixed directly onto the machine must be obeyed and must always remain legible. This applies for example to:

• Symbols for connections

• Data and motor data plate

• Instruction and warning plates

The operator is responsible for observing local regulations.

6

| www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

 

 

 

 

Safety

2.3Designated use

The machine must only be operated in such areas as are described in the operating instructions:

• only operate the machine in a technically perfect condition

• do not operate the machine when it is only partially assembled

• the machine must only be operated at an ambient temperature and a suction temperature of between 5 and 40°C

Please contact us for temperatures outside this range.

• the machine may convey, compress or extract the following media:

• Air

The air extracted may contain water vapour but no water or other liquids. For water vapour compatibility see Info I 200

• all non-explosive, non-inflammable, non-ag- gressive and non-poisonous dry gases and gas air mixtures

2.4Unacceptable operating modes

• extracting, conveying and compressing explosive, inflammable, aggressive or poisonous media, e.g. dust as per ATEX zone 20-22, solvents as well as gaseous oxygen and other oxidants

• extracting, conveying and compressing explosive, inflammable, aggressive, oxidative or poisonous media, e.g. dust as per ATEX zone 20-22, solvents

• using the machine in non-commercial plants if the necessary precautions and protective measures have not been taken in the plant

• installing in environments that are at risk of explosions

• using the machine in areas with ionising radiation

• back pressures on the outlet side of more than +0,1bars

• modifications to the machine and accessories

 

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |

7

 

 

Safety

2.5Personal qualifications and training

• Ensure that people entrusted with working on the machine have read and understood these operating instructions before starting work, particularly the safety instructions for installation, commissioning, maintenance and inspection work.

• Manage the responsibilities, competence and monitoring of staff

• all work must only be carried out be technical specialists:

• Installation, commissioning, maintenance and inspection work

• Working with electricity

• personnel being trained to work on the machine must be supervised by technical specialists only

2.6Safety-conscious work

The following safety regulations apply in addition to the safety instructions and intended use listed in these instructions:

• Accident prevention regulations, safety and operating regulations

• the standards and laws in force

2.7Safety notes for the operator

• hot parts of the machine must not be accessible during operation or must be fitted with a guard

• People must not be endangered by the free extraction or discharge of pumped media

• Risks arising from electrical energy must be eliminated.

8

| www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

 

 

 

 

Safety

2.8Safety instructions for installing, commissioning and maintenance

The operator will ensure that any installation, commissioning and maintenance work is carried out by authorised, qualified specialists who have gained sufficient information by an in-depth study of the operating instructions.

Only work on the machine when it is idle and cannot be switched on again

Ensure that you follow the procedure for decommissioning the machine described in the operating instructions.

Fit or start up safety and protective devices again immediately after finishing work.

Conversion work or modifications to the machine are only permissible with the manufacturer’s consent.

Only use original parts or parts approved by the manufacturer. The use of other parts may invalidate liability for any consequences arising.

Keep unauthorised people away from the machine

2.9Guarantee conditions

The manufacturer’s guarantee or warranty will no longer apply in the following cases:

• Improper use

• Not complying with these instructions

• Operation by insufficiently qualified staff

• Using spare parts that have not been approved by Gardner Denver Schopfheim GmbH

• Unauthorised modifications to the machine or the accessories supplied by Gardner Denver Schopfheim GmbH

 

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |

9

 

 

Transport, storage and disposal

3Transport, storage and disposal

3.1Transportation

3.1.1

Unpack and check the delivery conditionn

 

 

 

 

 

a) Unpack the machine on receipt and check for

 

 

 

 

 

transport damage.

 

 

 

 

 

b) Notify the manufacturer of transport damage im-

 

 

 

 

 

mediately.

 

 

 

 

 

c) Dispose of the packaging in accordance with the

 

 

 

 

 

local regulations in force.

3.1.2

Lifting and transporting

 

 

 

 

 

 

 

 

 

 

 

WARNUNG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tod oder Quetschen von Gliedmaßen durch

 

 

 

 

 

herabfallendes oder kippendes Transportgut!

 

 

 

 

 

 

 

 

 

 

 

When transporting with the lifting device remem-

 

 

 

 

 

ber:

 

 

 

 

 

a) Select the lifting device suitable for the total

 

 

 

 

 

weight to be transported.

 

 

 

 

 

b) Ensure that the machine cannot tip and fall

.

 

 

 

 

c) Do not stop under a suspended load.

 

 

 

 

 

d) Put the goods to be conveyed on a horizontal

 

 

 

 

 

base.

 

 

 

 

 

Lifting device/ Transporting with a crane

 

 

 

 

 

 

 

 

 

 

 

WARNUNG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bodily injury resulting from improper operation

 

 

 

 

 

a) Loads crosswise to the ring level are not per-

 

 

 

 

 

mitted.

 

 

 

 

 

b) Avoid impact stress.

2

1

 

 

 

 

 

a) Tighten the eyebolt firmly.

 

 

 

 

 

 

 

 

 

 

b) To lift and transport the machine it must be sus-

 

 

 

 

 

 

 

 

 

 

pended on the pump housing eyebolt (Fig. 1/1)

 

 

 

 

 

and the motor housing eyebolt (Fig. 1/2). If the

 

 

 

 

 

eyebolt is missing the motor must be lifted with

 

 

 

 

 

a rope sling.

 

 

 

 

 

 

Fig. 1 Lifting and transporting

1Eyebolt

2Eyebolt

10

| www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

 

 

 

 

Transport, storage and disposal

3.2

Storage

 

 

 

 

 

 

 

 

NOTICE

 

 

 

 

 

 

 

 

 

 

 

Material damage caused by improper storage.

 

 

 

 

 

 

 

 

Ensure that the storage area meets the following

 

 

 

conditions:

 

 

a)

dust free

 

 

b)

vibration free

 

3.2.1

Ambient conditions for storage

 

 

 

 

 

 

 

 

Ambient conditions

Value

 

 

 

 

 

 

Relative humidity

0% to 80%

 

 

 

 

 

 

Storage temperature

-10°C to +60°C

 

 

 

 

 

For long-term storage (more than 3 months), it is useful to use a preservation oil rather than operating oil.

See Info “Machine storage guidelines” I 150

3.3Disposal

WARNING

Danger from inflammable, corrosive or poisonous substances.

Machines that come into contact with hazardous substances must be decontaminated before disposal.

When disposing ensure the following:

a) Collect oils and grease separately and dispose of in accordance with the local regulations in force.

b) Do not mix solvents, limescale removers and paint residues

c) Remove components and dispose of them in accordance with the local regulations in force.

d) Dispose of the machine in accordance with the national and local regulations in force.

e) Parts subject to wear and tear (marked as such in the spare parts list) are special waste and must be disposed of in accordance with the national and local waste laws.

 

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |