Elmo Rletschle G-BH1 instruction manual

0 (0)
Elmo Rletschle G-BH1 instruction manual

Edition: 12.2009 · 610.44479.40.000

Original operating instructions · English

Extra instruction manual G-BH1

Supplement to instruction manual 610.44434.40.000

Devices in group II, category 3/2GD and 3GD

2BH1 1 2BH1 2 2BH1 3 2BH1 4 2BH1 5 2BH1 6 2BH1 8 2BH1 9

G-Serie

G-Series

Seitenkanal

Side Channel

reg. 1 Safety

Contents

 

 

reg. 1

Safety ...................................................

2

reg. 1.2 General safety instructions...........

2

reg. 1.3

Other risks ....................................

2

reg. 2

Correct Use Of The Equipment............

2

reg. 3

Technical Data .....................................

4

reg. 3.1

Mechanical Data...........................

4

reg. 3.3

Operating conditions ....................

4

reg. 5

Installation ............................................

4

reg. 5.1 Setting up explosion prevention

 

 

 

design ...........................................

4

reg. 5.1 Setting up for biogas uses............

4

reg. 5.2 Electric power connection ............

5

reg. 5.3 Connecting the piping / hoses ......

5

 

reg. 5.3.1 Suction branch......................

5

reg. 1.3 Other risks

WARNING

Danger of possible burns from hot external surface of the unit (up to approx. 125°C [257°F]).

Cover the unit with a suitable protection against contact (e.g. perforated metal cover or wire covering).

reg. 2 Correct Use Of The Equipment

Point 2 “Intended Use” in instruction manual 610.44434.40.000 is replaced by:

reg. 7

Operation .............................................

5

reg. 9

Maintenance.........................................

5

reg. 9.1

Repairs / Troubleshooting ............

6

reg. 9.3

Decontamination and document of

 

 

compliance ...................................

7

13

Ancillaries ..................................................

7

13.1Pressure / vacuum shut-off valves

2BX47.. and 2BX48...........................

7

Declaration of Conformity....................................

8

Form for statement on safety...............................

9

This operating manual

Applies to G-BH1 side channel blower (units) types:

2BH1 1 2BH1 2 2BH1 3 2BH1 4 2BH1 5 2BH1 6 2BH1 8 2BH1 9

in explosion prevention design and

in explosion prevention design for biogas use.

contains instructions for the unit’s transportation, installation, start-up, operation, shut-down, storage, maintenance and disposal.

must be fully read and understood by operating or maintenance personnel before beginning any kind of work on or with the unit.

must be strictly adhered to.

must be at hand where the unit is installed.

reg. 1 Safety

reg. 1.2 General safety instructions

WARNING

Danger of burns from hot surface on the unit and from hot mediums!

The external surface of the unit can reach temperatures of up to about 125ºC [257 ºF]

Cover the unit with a suitable protection against contact (e.g. perforated metal cover or wire covering).

Do not touch when in operation.

Leave to cool down after switching it off.

Operating and maintenance personnel

Operating and maintenance personnel for G-BH1 units must be trained and authorised for the work to be carried out.

Work on electrical installations may only be carried out by a electrics specialist.

An electrics specialist is someone who can evaluate and identify potential risks for the assigned task as a result of their technical training, knowledge and experience as well as knowledge about relevant regulations.

© 2009 Gardner Denver Deutschland GmbH · Industriestraße 26 · 97616 Bad Neustadt · Germany

Replication, distribution and / or editing of this document and the use and distribution of its content is prohibited unless explicitly permitted. Violation obligates compensation for damages.

All rights reserved in case of the issue of a patent, utility patent or design patent.

reg. 2 Correct Use Of The Equipment

G-BH1 units

are equipped with RL 94/9/EG three-phase drive motors. For more detailed information please consult the motor manufacturer’s accompanying operating instructions.

exist in the following formats:

single-impeller

two-impeller, two-stage (for increased pressure difference)

two-impeller, double flow. (for increased conveyance volumes).

are designed for industrial plants.

are designed for continuous operation.

When operating the units, observe the limit values and following scope of application listed in chapter 3, “Technical data” of instruction manual 610.44434.40.000.

Scope of Application.

Inside area of explosion prevention design

G-BH1 units are suitable for conveying gases and dusts where under normal operating conditions a potentially explosive atmosphere is not expected to be present. If it does occur however, then only temporarily.

This specification includes category 3G and 3D for the internal space of the units.

Inside area biogas use

G-BH1 units are suitable for conveying gases with a relative humidity of up to 80% and dusts where under normal operating conditions a potentially explosive atmosphere is not expected to be present. If this should however arise, it will, in all probability, only be temporary.

This specification includes category 3G and 3D for the internal space of the units.

Surrounding area

When rating the device category, both the place where it is installed and its internal space must be taken into consideration.

Installing G-BH1 units for categories 3/2G and 3/2D is allowed for areas where potentially explosive gases and dusts are expected to occur occasionally.

The use of G-BH1 units for category 3G and 3D is allowed in areas where no potentially explosive atmosphere is present. If it does occur however, then only temporarily.

Foreseeable misuse

WARNING

Danger of explosions!

Gases, gas mixtures and dusts which are explosive when air is not present, or may change the machine’s safety-relevant material properties, must not be conveyed.

It is forbidden:

to use the unit for non-industrial facilities unless essential precautions and protection measures are fitted, such as guards to protect children's fingers;

to use the unit for category 3/2GD in areas where explosive gases and dusts occur constantly, frequently, or for long periods of time;

to use the unit for category 3GD in areas where explosive gases and dusts occur constantly, frequently, or for long periods of time;

to evacuate, convey and compress explosive, inflammable, or aggressive mediums;

to operate the unit using limits other then those stipulated in chapter 3 “Technical data”, p.8 and following pages in the standard operating manual;

in biogas uses:

to draw in from explosive areas, or discharge into explosive areas.

Unauthorised modifications to the units are forbidden due to safety reasons.

The operator is not allowed to carry out maintenance, servicing and repair work which require the machine to be dismantled.

© Gardner Denver Deutschland GmbH

3 / 12

610.44479.40.000

reg. 3 Technical Data

reg. 3 Technical Data

reg. 3.1 Mechanical Data Temperature increase

The temperature increase of the air outlet compared with the ambient air temperature stated in the tables in the standard operating manual are not valid for units in accordance with GL/ 94/9/EU

The gas temperature at the pressure side interruptor of the unit must not exceed 125°C [257°F].

reg. 5 Installation

WARNING

Danger of burns from hot surface on the unit and from hot mediums!

The external surface of the unit can reach temperatures of up to about 125ºC [257 ºF]

Install the unit in such a way that accidental contact with its surfaces is not possible.

Cover the unit with a suitable protection against contact (e.g. perforated metal cover or wire covering).

reg. 3.3 Operating conditions

WARNING

Danger of explosion due to the conveyed medium and the unit’s surfaces temperatures exceeding 125°C [257°F].

Operating the unit outside the pressure range indicated on the rating plate is prohibited as this leads to unacceptable temperature increases.

When there is simultaneous limited performance from suctioning and pressure, consult the manufacturer.

Temperature class is complied with.

under operating conditions stated in instruction manual 610.44434.40.000 and

during continuous operation and normal, nonfrequently recurring start-ups (maintaining a rest period of 5 minutes between two start-up procedures)

reg. 5.1 Setting up explosion prevention design

Set-up variations / Position

Extra note for vertical set-up:

If setting up units vertically, ensure that no foreign objects can fall into or block the ventilator of the engine by using a suitable protection device according to RL 94/9/EG.

The protection device may not affect the engine’s cooling function.

reg. 5.1 Setting up for biogas uses

Setting up in zone 2 areas must be carried out in adherence of the respective applicable rules and safety regulations.

Set up the unit in the open air. OR

With obligatory ventilation of the set up space in accordance with the applicable safety rules for biogas plants.

AND/ OR

Monitor air in the set up space in accordance with the applicable safety rules for biogas plants.

Set-up variations / Position

Only set up units for biogas uses in a level position.

610.44479.40.000

4 / 12

© Gardner Denver Deutschland GmbH