SPECIFICATIONS
GENERAL
elf-contained, wall hung electric refrigerated water cooler.
S
hilling capacity of 50°F drinking water, based upon 80°F inlet
C
ater and 90°F ambient.
w Model EZSTLR8C has self-closing Easy-Touch Controls on
and side. Refrigeration unit not included. Requires electricity to operate switches.
Model EZTLR8C has self-closing Easy-Touch Controls on the front of each unit.
Model EZTLRDDC Cabinet only. Easy-Touch Controls front and side. Refrigeration unit not included. Requires electricity to oper­ate switches.
All models have a hooded stream projector with Easy-Touch Controls that require less than 3 pounds of force to activate. Commercial-grade solenoid based flow control. Valve with built­in flow regulator provide constant stream from 20 to 105 psi water pressure. Bubbler orifice fully protected to meet all sani­tary codes.
NOTE: Minimum 40 psi supply line pressure required in spe­cial circumstances where both sides of bi-level are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units.
This model cooler consists of a refrigerated upper unit which requires a water supply and electrical supply. A drain outlet is required on the lower unit.
ADA COMPLIANT
These Water Coolers comply with the requirements of A.D.A. (Americans with Disabilities Act) when properly installed. Unit is compliant if installed in an alcove and is also compliant when mounted on an exposed wall if a wing wall is located on the right side or if LKAPREZL apron is installed under upper unit. Also meets the guidelines for children’s environments providing the floor to orifice height is 30" or less on the lower unit and proper clear floor space is provided for parallel approach. (Based on Architectural and Transportation Barriers Compliance Board final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined by the Safe Drinking Water Act. Elkay Water Coolers are manu­factured with a waterway system utilizing copper components and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and convenient removal of water­borne particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
**GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
EZSTLR8C 8.0 9.7 8.8 8.0 370 4.0 Yes 89 EZTLR8C 8.0 9.7 8.8 8.0 370 4.0 Yes 89 EZSTLRDDC –– – – –– Yes 66 EZTLRDDC –– – – –– Yes 66
**Based on 80°F inlet water temperature. †Glass filler available at extra cost. Requires factory preparation to receive glass filler. Upper unit only.
Rated watts shown are based on operational (run) time, in compliance with A.R.I. Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Room Temperature °F
Elkay
elkayusa.com
Full Glass† Ship.
Rated Load Filler Wt.
2222 Camden Court Oak Brook, IL 60523
Barrier-Free Access (Adult & Child)
NSF/ANSI 61 Compliant – Models EZTLR8C,
EZSTLR8C, EZSTLRDDC and EZTLRDDC
Model EZSTLR8C
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 115VAC, 60Hz single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug (domestic models).
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is stainless steel. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. requirements for self-extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble-free operation.
Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude require­ments. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports refrigeration system and fastens to wall. Provides increased structural integrity and rigidity to cooler.
Stainless Steel Basin: Type 304, one piece polished to a uniform Elkay bright luster finish. Basin has integral drain grid, embossed bubbler pad. No exposed fasteners.
Exclusive Flexi-Guard
®
Safety Bubbler: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Keyed in location to prevent rotation.
Upper Shroud: Contoured shock-absorbing, provides additional protection against accidental injury. No exposed fasteners.
Lower Shroud: One piece easy to remove and replace. Allows access to internal components from three sides.
Cabinet: Cabinet design allows for flush to wall mounting. No recess space is required.
Color Selection: Unless otherwise specified cabinet is two-tone gray upper shroud with textured gray lower shroud. Stainless Steel lower shrouds available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrigera­tion system of the unit. Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caus ed by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including NSF/ANSI 61-ANNEX G, AB 1953.
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Model EZTLR8C
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 12-25F
INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MINIMUM CLEARANCE FROM CABINET LOUVERS TO WALL.
C
L
C
L
B
A (ALT. LOCATION)
D (ALT. LOCATION)
3 7/8"
99mm
21 7/8"
556mm
17 7/16"
443mm
19"
483mm
REFRIGERATED UNIT
DUMMY UNIT
D (PREFERED LOCATION)
F
F
22 15/16"
583mm
24 1/2"
623mm
28 13/16"
732mm
34 5/16"
872mm
13/16"
21mm
2"
51mm
7"
178mm7"178mm
2"
51mm
5 3/4"
146mm
19 7/16"
494mm
2"
51mm
2
"
51mm
18 3/8"
467mm
6 3/8"
162mm 6 3/8"
162mm
6 3/8"
162mm 6 3/8"
162mm
1
8 3/8"
467mm
O
9/32"
7mm
31 5/16"
796mm
5 7/8"
150mm
19"
484mm
8 1/16"
205mm
RIM HEIGHT
ADA Requirement
C
HANGER
BRACKET
12 1/2"
318mm
38 3/8"
975mm
O
RIFICE
HEIGHT
*
*
*
*
27"
686mm 3"
76mm
*
*
*
*
*
*
*
*
*
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER.
A (PREFERRED LOCATION)
13 15/16"
354mm
*
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT-OFF (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE.
3" (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET TO ACCOMODATE 1-1/2" NOMINAL DRAIN. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/2 TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
REFRIGERATED UNITNON-REFRIGERATED UNIT
INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MINIMUM CLEARANCE FROM CABINET LOUVERS TO WALL.
C
L
C
L
B
A (ALT. LOCATION)
D (ALT. LOCATION)
3 7/8" 99mm
21 7/8" 556mm
17 7/16"
443mm
19"
483mm
REFRIGERATE D UNIT
DUMMY UNIT
D (PREFERED L OCATION)
F
F
22 15/16" 583mm
24 1/2" 623mm
28 13/16" 732mm
34 5/16" 872mm
13/16" 21mm
2" 51mm
7" 178mm
7" 178mm
2" 51mm
5 3/4" 146mm
19 7/16" 494mm
2" 51mm
2
"
51mm
18 3/8" 467mm
6 3/8" 162mm
6 3/8" 162mm
6 3/8" 162mm
6 3/8" 162mm
1
8 3/8"
467mm
O
9/32" 7mm
31 5/16"
796mm
5 7/8"
150mm
19"
484mm
8 1/16" 205mm
RIM HEIGHT
ADA Requirement
C
HANGER BRACKET
12 1/2" 318mm
38 3/8" 975mm
O
RIFICE
HEIGHT
*
*
*
*
27"
686mm
3"
76mm
*
*
*
*
*
*
*
*
*
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER.
A (PREFERRED LOCATION)
13 15/16" 354mm
*
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT-OFF (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE. 3" (76mm) MAXIMUM OUT FROM WALL B = RECOMMENDED LOCATION FOR WASTE OUTLET TO ACCOMODATE 1-1/2" NOMINAL DRAIN. DRAIN STUB 2 IN. OUT FROM WALL C = 1-1/2 TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
REFRIGERATED UNITNON-REFRIGERATED UNIT
Two Station Wall Mount Water Coolers (Reversed)
®
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE
C
ONNECT
C
OLD WATER
S
UPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE
C
ONNECT
C
OLD WATER
S
UPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
Barrier-Free Access (Adult & Child) NSF/ANSI61 Compliant – Models EZTLR8C, EZSTLR8C, EZSTLRDDC and EZTLRDDC
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
he grounding of electrical equipment such as telephone, computers, etc., to water
T
ines is a common procedure. This grounding may be in the building but may also
l
ccur away from the building. This grounding can cause electrical feedback into a
o
ater cooler creating an electrolysis which creates a metallic taste or causes an
w
ncrease in the metal content of the water. This condition is avoidable by installing the
i
ooler using the proper materials as shown below.
c
his water cooler must be connected to the water supply using a dielectric coupling.
T
he cooler is furnished with a non-metallic strainer which meets this requirement.
T The drain trap which is provided by the installer should also be plastic to completely
isolate the cooler from the building plumbing system.
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
OTICE
N
Elkay
12-25F (Rev. 4/11)
RATED FOR INDOOR APPLICATIONS ONLY
FRONT VIEW
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2011 Elkay
Loading...