Elkay ER191 Installation Manual

10 1/4 "
260mm
130mm
ER19*1D ER19*2D ER19*3D
Installation Instructions
ER191/ER192/ER193
Refrigeration Packages
NOTICE: This water cooler must be connected to the water
supply using a dielectric coupling.
NOTE: It is important to insure proper ventilation. Allow a
23 "
584mm
8 1/8 "
205mm
4 1/4 "
114mm
minimum clearance of 12 inches (305 mm) in front and 3 inches (76mm) in the rear of the unit. If unit is to be installed in an enclosure, allow the following clearances around unit - 1 inch (25mm) each side, 3 inches (76mm) in the rear, 3 inches (76mm) inches above wall.
This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. The fitting should be replaced if the unit is to be used with more aggressive fluids.
For use with photo processing applications, adjust cold control to warmer settings.
1 9/16 " 40mm
1 1/4 "
32mm
A
TEMPERATURE ADJUSTMENT
C
B
123mm
ELECTRICAL
1 3/4 "
44mm
25 3/4 "
654mm
ALTERNATE ELECTRICAL LOCATION
LEGEND
A = 3/8" O.D. TUBE W A TER OUT
B = 3/8" O.D. TUBE WA TER INLET
C = 3/8" O.D. TUBE T ANK DRAIN
98638C (Rev. B - 10/11)
ITEMIZED PARTS LIST
ITEM
NO.
10 11
*12
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
31 NS NS
1 2 3 4 5 6 7 8 9
PART NO.
23089C 35882C
35895C 36072C 30502C
41991000
70018C 70009C 66628C
32817000
36327C 36320C 36326C 36324C 36325C
32580005
36070C 50196C 66625C 27957C 70772C 27197C 28176C 28180C 23101C 23104C 28178C 66629C 36071C 36080C 70274C 27198C 66204C
DESCRIPTION
Terminal Box Cover Cold Control Cold Control (Freeze Protect) Fan Motor Fan Blade Fan Bracket Fan Nut Motor Mounting Screw Condenser Shroud CSR Box Assy Compressor Service Pak Overload Overload Cover Overload Cover Strap Spring Wire - #16Ga. Black Wire - #16Ga. Black Grommet Evaporator Assy Insulation Box Cover Drain Plug Grill (Front) Base Assy Insulation Box Panel (Rear) End Panel Insulation Box (Front) Terminal Box Heat Exchanger Wire - #16Ga. Black Wire - #16Ga. White Compressor Mounting Sleeve Grill (Rear) Drier
ER19-2D/3D 220V-50/60 HZ
ITEM
PART NO.
NO.
4
36073C
11
36305C
*12
36308C
13
36306C
14
36230C 36229C
*INCLUDES COMPRESSOR, OVERLOAD & CSR BOX ASSEMBL Y. IF UNDER WARRANTY , REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBL Y. NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
DESCRIPTION
Fan Motor CSR Box Assy Compressor Service Pak Overload Overload Cover Overload Bracket
ER19*1D ER19*2D ER19*3D
INSTALLATION
1. Potable water inlet and outlet are 3/8" (9 mm) O.D. tube located on top of unit. Contractor to supply connections as required.
2. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler. If flushing does not remove all particles, a water strainer should be installed in supply line.
3. Connect cooler to building supply line with a shut-off valve and install a union connection between the valve and cooler.
4. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor
directly to the power supply.
START-UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain.
3. Connect to electrical power.
TROUBLESHOOTING & MAINTENANCE
Temperature Control: Factory set for 50° F water under normal
conditions. To adjust water temperature, turn screw on Item No. 2
clockwise for colder, counter clockwise for warmer. Ventilation: Cabinet louvers should be periodically cleaned with brush,
air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector
Lubrication: Motors are lifetime lubricated.
28
20
2
3
24
1, 27
4, 5, 6, 7, 8
Wiring Diagram
BLACK
WHITE
30
98638C (Rev. B - 10/11)
17
GREEN
FAN
RELAY
1
M
START
CAPACITOR
ELKAY MANUF ACTURING COMP ANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
19
9, 10
FREEZE CONTROL
22
BLACK
16
COLD CONTROL THERMOSTAT
11
29
BLACK
BLACK
2
LS
WHITE
COMPRESSOR
S
O/L
C
R
13, 14, 15
25
RED
26
21
REPAIR SER VICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PAR TS, CONT ACT YOUR LOCAL DISTRIBUT OR OR CALL 1.800.323.0620
12
23
18, 31