Power Supply
Model XR-38
INTRODUCTION
The Model XR-38 has a regulated output of 13.8 volts @ 3A and capable of handing 5A surges up to 30 minutes. The XR-38 is designed to power automotive equipment such as CB radios, stereo systems, mobile two-way radios, and vehicular alarm systems when removed from the vehicle.
OPERATING PROCEDURE
1.
Check the voltage rating of the equipment to be powered. Care must be taken not to exceed this rating.
2. Turn the power supply OFF.
3. Plug the line cord into a 120V, 60Hz AC outlet.
4. With the power supply turned OFF, connect the load to the output.
IMPORTANT SAFETY INSTRUCTIONS
1.
Save these instructions. This manual contains important safety and operating instructions.
2.
The XR-38 is thermal, short and fuse protected against server overloads or shorting of the output terminals. Refer to the Maintenance section for fuse or thermal protection information.
3. Service repair should be performed by qualified personnel or returned to the factory when service or repair is required. Incorrect reassembly may result in a risk of electrical shock or fire.
4. Do not expose the power supply to rain or snow. Use only indoors with normal temperature and humidity.
Specifications
Input 120VAC, 60Hz
Output 13.8VDC @ 3A, 5A surge
Load Regulation Less than 5%
5. Turn the power supply ON.
MAINTENANCE
Fuse replacement
1. Turn power switch off, remove any load on outputs and unplug the line cord from AC line.
2. Unscrew the fuse holder cap and remove the fuse. Install a new 2A 250V fuse and reattach fuse holder cap.
3. Plug line cord back into 120VAC source and turn the power switch ON. Check the output for correct voltage.
Thermal
A thermal device inside the transformer will open the primary side if the internal temperature gets too hot. There should be no output voltage and the illuminated switch will not light. Follow the steps below if thermal protection activates.
Ripple Less than 10mV rms
Output Protection Thermal and short
Input Protection 2A, 250V fuse
Size 4 5/16” (H) x 6” (W) x 8 3/16”(L)
Weight 5 lbs., 8 oz.
1. Turn the power switch off and allow unit to cool down. This may take up to 30 minutes.
2. After the unit cools down, turn the power switch to ON. Check that the switch lights and the output voltage is 13.8V. The unit is now ready for operation again.