To enable you to use your appliance effectively and safely, please read this instruction book carefully before using
the appliance and retain for future reference. If you require guidance in the use of the appliance or require further
information on Electrolux Products, please contact our Customer Care Department. For general enquiries
concerning your Electrolux appliance or for further information, visit our website at http:\\www.electrolux.co.uk
Customer Care Department
Electrolux
55 - 77 High Street
Slough
Berkshire
SL1 1DZTel:08705 950 950
To register ownership, please ensure you complete and return the guarantee card supplied with the
appliance.
For the User
Important Safety Information
Your Appliance
Operating Instructions
Cooker Hood Controls
To Operate
Extraction
Recirculation
Maintenance and Cleaning
External Cleaning
Charcoal Filters
To Remove the Charcoal Filter
Synthetic Grease Filter
To Replace the Paper Grease Filter
Changing the Light Bulb
Something Not Working
Service and Spare Parts
Guarantee Conditions
For the Installer
Installation Instructions
Technical Information
Electrical Connections
Electrical Requirements
Electrical Connection
Installing the Cooker Hood
Installation Requirements
Ducting
Clearance Height
Unpacking
Fixing the Cooker Hood into the Housing/Canopy
Positioning the Cooker Hood
Venting
Recirculation
Insert the Charcoal Filters
Extraction
Ducting
Service Force Centres
Guide to use the instruction book
The following Symbols will be found in the text to guide you through the instruction book
Safety instructions Step by step instructions
2
IMPORTANT SAFETY INFORMATION
These warnings are provided in the interests of your safety. Ensure that you understand them all before
installing or using this appliance. Your safety is of paramount importance. If you are unsure about any of
the meanings of these warnings contact the Customer Care Department.
Installation
• Any installation work must be undertaken by a
qualified electrician or a competent person.
• This hood must be installed in accordance with the
installation instructions and all measurements must
be adhered to.
• If the cooker hood is installed for use above a gas
appliance then the provision for ventilation must be
in accordance with the Gas Safety Codes of
Practice BS.6172, BS.5440 and BS.6891 (Natural
Gas) and BS.5482 (LP Gas) 1994, the Gas Safety
(Installation & Use) Regulations, the Building
Regulations issued by the Department of the
Environment, the Building standards (Scotland)
(Consolidated) Regulations issued by the Scottish
Development Department.
• The fan motor of this cooker hood incorporates a
cut-out device which will operate if the cooker hood
is installed below the minimum height
recommended under section ‘Clearance Height’, or
if the motor becomes overheated. If the cut-out
device is activated, switch off the fan motor and
allow the cooker hood to cool. The cut-out device
will reset itself when the fan motor has cooled
significantly.
• It is dangerous to alter the specifications or modify
this product in any way.
• When installed between adjoining wall cabinets the
wall cabinets must not overhang the hob.
• If the room where the hood is to be used contains a
fuel burning appliance such as a central heating
boiler then its flue must be of the room sealed or
balanced flue type.
• Do not install above a cooker with a high level grill.
Child Safety
• This appliance is designed to be operated by
adults. Children should not be allowed to tamper
with the controls or play with the appliance.
During Use
• This product is for domestic use only.
• Never leave frying pans unattended during use as
over-heated fats and oils might catch fire.
• Never do flambé cooking under this cooker hood.
• Do not leave naked flames under the hood.
Maintenance and Service
• This appliance can be a hazard if the synthetic
paper and charcoal filters are not replaced as
recommended.
• Under no circumstances should you attempt to
repair the appliance yourself. Repairs carried out
by inexperienced persons may cause injury or
more serious malfunction. Refer to your local
Electrolux Service Force Centre. Always insist on
genuine spare parts.
• If other types of flue or appliances are fitted ensure
that there is an adequate supply of air to the room.
• The ducting system for this appliance must not be
connected to any existing ventilation system which
is being used for any other purpose.
3
YOUR APPLIANCE
OPERATING INSTRUCTIONS
The cooker hood is designed to extract unpleasant
odours from the kitchen, it will not extract steam.
To obtain the best performance it is advisable to
switch on the hood a few minutes before you start
cooking and leave it running for approximately 15
minutes after finishing.
Cooker Hood Controls
The cooker hood functions are controlled by slide
switches, located centrally in the front edge of the
metal grille panel.
EFG 525
L. Light ON/OFF control
0 - Off
1 - On
V. Fan Speed Control
Position 0 - Off
Position 1 - Low
Position 2 - Normal
Position 3 - Boost
EFG 530
L. Light ON/OFF control
0 - Off
1 - On
EFG 525
EFG 530
4
M. Motor ON/OFF control
0 - Off
1 - On
V. Fan Speed Control
Position 1 - Low
Position 2 - Normal
Position 3 - Boost
To Operate
Select the required functions.
The appliance can be installed to recirculate or extract
contaminated air. The cooker hood is more effective
when used in the extraction mode.
Extraction
In the extraction mode the contaminated air enters the
cooker hood, passes through the grease filter and out
through the ducting to the atmosphere.
Recirculation
In the recirculation mode contaminated air is passed
through the charcoal filters to be purified and
recirculated into the kitchen through a recirculation
grille. Ensure the charcoal filters are in position.
When the ducting mode is selected the
charcoal filters are not required.
Never do flambé cooking under this cooker
hood.
Never leave frying pans unattended during use
as over-heated fats and oils can catch fire.
Do not leave naked flames under the cooker
hood.
Ensure heating areas on your hob are covered
with pots and pans when using the hob and
cooker hood simultaneously.
5
MAINTENANCE AND CLEANING
Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
The cooker hood must be kept clean, as a
build up of grease or fat can be a fire hazard.
The external surfaces of the hood should be
cleaned regularly. Wipe the cooker hood
frequently with warm soapy water using a mild
detergent. Dry thoroughly after cleaning.
Always wear protective gloves when cleaning
the hood.
Never use scouring pads or abrasive cleaners.
Never use excessive amounts of water when
cleaning particularly around the control panel.
Charcoal Filter
The charcoal filters absorb the odours from cooking.
They will slowly become saturated and gradually less
effective.
The charcoal filters cannot be cleaned, we
recommend they are replaced every 3-6 months or
more often if the hood is used for more than 3 hours
per day.
To Remove/Replace the Charcoal
Filters
1.Remove the lower grille, supporting the grille
with one hand and draw down on the two grey
handles (located on each side of the grille).
2.The charcoal filters are left and right handed
and should be fitted one at a time.
3.Insert one end of the filter into the slots in the
fan housing then lower the other end until the
tab engages the slot in the casing.
Synthetic Grease Filter - EFG 525
The synthetic grease filter cannot be cleaned.
It cannot be washed.
To Replace the Synthetic Grease
Filter
1.Remove the lower grille.
2.Push the wire retaining clips to the side and
remove.
3.Clean the metal grille and clips before
6