Eldes ESIM320, ESIM120 User Manual

4.7 (3)
ELDES GATE
CONTROLLER
ESIM120/ESIM320/ESIM320US
2
2 EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
User Manual v1.1
Valid for ESIM120/ESIM320 v21.05.00 and up
Please read and follow these safety guidelines to safeguard yourself and others:
• Gate controller ESIM120/ESIM320 (later referred to as “the system” or “ the device”) contains a built-in radio transceiver operating in
850/900/1800/1900 MHz (ESIM120 2G); 850/900/1800/1900/2100 MHz (ESIM320 3G/2G EU); 850/1900 MHz (ESIM320US 3G USA)
bands respectively.
• DO NOT use the system where it can cause potential danger and interfere with other devices – such as medical devices.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impact.
• NEVER install or carry out maintenance during stormy weather.
• DO NOT attempt to repair the system yourself – any repairs must be carried out by fully qualied personnel only.
Disconnect the mains power before installing. Never install or carry out maintenance during stormy weather. The electric sock-
et that powers the system must be easily accessible.
Please use the 10-24V 50Hz/60 Hz ~200mA AC or 10-24V 200mA DC power supply unit that meets the EN 60950-
1 standard. Any additional device you connect to the system, such as a computer, must also be powered by an EN 60950-1
approved supply. When connecting the power supply to the system, switching the polarity terminal places does not have any
aect.
External power supply can be connected to AC mains only inside installation room
with automatic 2-pole circuit breaker capable of disconnecting circuit in the event of
short circuit or over-current condition. Open circuit breaker must have a gap between
connections of more than 3mm (0.12in) and the disconnection current 5A.
Phase
AC 230V
50 Hz/60 Hz/DC 24V
USB cable
Null
PE
ESIM120/
ESIM320
AC/DC
To switch the system o, unplug the external electric power supply from or any other linked device that the system is powered
from.
A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (fuse
F1 model – MINISMDC050F 0.5A).
If you use a computer for the device conguration, it must be earthed.
The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that
the product must not be disposed of together with household waste. To prevent possible harm to human health and/or the en-
vironment, the product must be disposed of in an approved and environmentally safe recycling process. For further information
on how to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal
in your area.
3
3EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
CONTENTS
1. GENERAL INFORMATION ...........................................................................................................................................................5
2. TECHNICAL SPECIFICATIONS ....................................................................................................................................................5
2.1. Electrical and Mechanical Characteristics .....................................................................................................................................................5
2.2. Main Unit, LED Indicator and Connector Functionality ...............................................................................................................................6
2.3. Wiring Diagrams ................................................................................................................................................................................................7
3. INSTALLATION ...........................................................................................................................................................................8
4. GENERAL OPERATIONAL DESCRIPTION....................................................................................................................................9
5. CONFIGURATION METHODS ......................................................................................................................................................9
5.1. SMS Text Messages ...........................................................................................................................................................................................9
5.2. ELDES Conguration Tool Software ...............................................................................................................................................................9
5.2.1. Remote Connection ..........................................................................................................................................................................................9
5.2.2. Ending the Remote Connection Session .......................................................................................................................................................9
6. SYSTEM LANGUAGE .................................................................................................................................................................10
7. SMS PASSWORD .......................................................................................................................................................................10
8. ADMINISTRATOR PHONE NUMBERS .......................................................................................................................................11
9. DATE AND TIME........................................................................................................................................................................12
9.1. Automatic Date and Time Synchronization ................................................................................................................................................12
10. USER PHONE NUMBER DATABASE .........................................................................................................................................13
10.1. User Validity and Access Restriction ...........................................................................................................................................................15
11. OUTPUTS ................................................................................................................................................................................17
11.1. Output Names ..................................................................................................................................................................................................17
11.2. Output Control by Free of Charge Phone Call .............................................................................................................................................17
11.3. Output Control by SMS Text Message ..........................................................................................................................................................18
11.4. Output Control Conrmation by Call Back .................................................................................................................................................. 20
11.5. Output Control from any Phone Number....................................................................................................................................................20
11.6. Automatic Output Control ..............................................................................................................................................................................21
12. SCHEDULERS ..........................................................................................................................................................................22
13. EVENT LOG ............................................................................................................................................................................. 24
14. INPUTS ....................................................................................................................................................................................25
14.1. Input Names and Alarm Notications ..........................................................................................................................................................25
14.2. Disabling and Enabling Inputs ...................................................................................................................................................................... 26
15. SYSTEM INFORMATION. INFO SMS .........................................................................................................................................27
15.1. Periodic Info SMS .............................................................................................................................................................................................27
16. SYSTEM NOTIFICATIONS ....................................................................................................................................................... 28
16.1. SMS Text Message Delivery Restrictions ................................................................................................................................................... 28
16.2. SMSC (Short Message Service Center) Phone Number ............................................................................................................................ 28
17. GPRS NETWORK SETTINGS ................................................................................................................................................... 29
18. INCOMING PHONE NUMBER VERIFICATION SETTINGS ........................................................................................................ 30
19. REMOTE SYSTEM RESTART ................................................................................................................................................... 30
20. TECHNICAL SUPPORT ............................................................................................................................................................31
20.1. Troubleshooting ..............................................................................................................................................................................................31
20.2. Restoring Default Parameters ......................................................................................................................................................................31
20.3. Updating the Firmware via USB Cable .........................................................................................................................................................31
21. ELDES CLOUD SERVICES .........................................................................................................................................................32
22. RELATED PRODUCTS ..............................................................................................................................................................33
4
4 EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
TERMS OF USE
The following terms and conditions govern use of the ELDES GATE CONTROLLER device and contains important information on limitations
regarding the product’s use and function, as well as information on the limitations of the manufacturer’s liability. Please carefully read
these terms and conditions. For more information on your product, please visit eldesalarms.com
TECHNICAL SUPPORT
In order to ensure continuous and proper operation of the ELDES Gate Controller device and uninterrupted service, it is the responsibility
of the User to make sure that: (I) the product is properly installed, and (II) there is constant electrical supply. If you experience diculty
during the installation or subsequent use of the system, you may contact “ELDES, UAB” distributor or dealer in your country/region. For
more information, visit eldesalarms.com
WARRANTY PROCEDURES
Warranty and out of warranty service should be obtained by contacting the system integrator/dealer/retailer/e-tailer or distributor where
the customer purchased the product. When requesting for service, the proof of purchase and the product serial number must be provided.
The return of the defective product should be strictly through the original route of purchase, and the customers shall pack the product
appropriately to prevent the returned product from suering in the transportation.
MANUFACTURER WARRANTY
“ELDES, UAB” provides a limited warranty for its products only to the person or entity that originally purchased the product from “ELDES,
UAB” or its authorized distributor or retailer and materials under normal use of the system for a period of twenty four (24) months from the
date of shipment by the “ELDES, UAB” (Warranty Period). Warranty obligations do not cover expandable materials (power elements and/or
batteries), holders and enclosures. The warranty remains valid only if the system is used as intended, following all guidelines outlined in
this manual and in accordance with the operating conditions specied. The warranty is void if the system has been exposed to mechanical
impact, chemicals, high humidity, uids, corrosive and hazardous environments or force majeure factors. If a hardware defect arises and a
valid claim is received within the Warranty Period, at its own discretion, “ELDES, UAB” will either (a) repair a hardware defect at no charge,
using new or refurbished replacement parts, or (b) exchange the product with a product that is new or which has been manufactured from
new or serviceable used parts and is at least functionally equivalent to the original product, or (c) refund the purchase price of the product.
LIMITED LIABILITY
The buyer must agree that the system will reduce the risk theft, burglary or other dangers but does not provide guarantee against such
events. “ELDES, UAB” will not assume any responsibility regarding personal or property, or revenue loss while using the system. “ELDES,
UAB” shall also assume no liability due to direct or indirect damage or loss, as well as unreceived income when using the system, including
cases, when the damages arise due to the above mentioned risks, when due to breakdown or malfunction the user is not informed in a
timely manner about a risk which has arisen. In any case, the liability of “ELDES, UAB”, as much as it is allowed by the laws in force, shall not
exceed the price of acquisition of the product.
CONSUMER PROTECTION LAWS
FOR CONSUMERS WHO ARE COVERED BY CONSUMER PROTECTION LAWS OR REGULATIONS IN THEIR COUNTRY OF PURCHASE OR, IF
DIFFERENT, THEIR COUNTRY OF RESIDENCE, THE BENEFITS CONFERRED BY THIS WARRANTY ARE IN ADDITION TO ALL RIGHTS
AND REMEDIES CONVEYED BY SUCH CONSUMER PROTECTION LAWS AND REGULATIONS. This warranty grants upon you specic
legal rights, and you may also have other rights that vary by country, state or province.
Dear Customer,
Thank you for choosing to purchase ELDES GATE CONTROLLER ESIM120/ESIM320. Your thoughtful decision will ensure reliable solution
for many years as all ELDES products are manufactured to meet the highest standards.
We are condent that you will be completely satised with your product. However, in the unlikely event that you do experience a
problem, please contact the dealer from whom you made your purchase.
ELDES, UAB
eldesalarms.com
Contents of Pack
Item Quantity
1. ESIM120/ESIM320 .................................1
2. User manual ............................................1
3. Antenna ...................................................1
Not included:
• SIM card – we recommend you get a contract SIM, not Pay As You Go.
• mini-USB cable – can be obtained from your local distributor.
Copyright © “ELDES, UAB”, 2018. All rights reserved.
It is strictly forbidden to copy and distribute the information contained in this document or to pass thereof to
a third party without an a priori written authorization obtained from “ELDES, UAB”. “ELDES, UAB” reserves the
right to update or modify this document and/or related products without an a priori warning. “ELDES, UAB”
hereby declares that ELDES gate controller is in compliance with the essential requirements and other rele-
vant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at eldesalarms.com.
5
5EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
1. GENERAL INFORMATION
ELDES GATE CONTROLLER ESIM120/ESIM320 is a micro-controller based device intended to provide access control for gate automatics,
road barriers or to remotely turn ON/OFF any electrical appliance via the GSM/3G network.
Examples of using the system:
• Access control.
• Parking lot control of residential houses or oces.
• Gate control of private houses.
• Any electrical appliance control: lighting, watering, heating etc.
• Remote reboot of the “frozen” systems, such as computer network or a server.
Main features
• Manual output control by free of charge phone call.
• Automatic output control in accordance with the scheduled time.
• Congurable output pulse duration.
• Automatic date and time synchronization.
• Up to 5 administrators for system conguration by SMS text messages, acceptance of input alarm SMS text messages, output control
by SMS text message and free of charge phone call.
• User database capacity – up to 2000 users for output control by free of charge phone call.
• User phone number validity limitation in accordance with a set deadline (date/time) or number of rings to the system.
• Output control restriction for users in accordance with the specied weekdays and time.
• Event log of 1000 events containing date and time as well as administrator/user phone number and user name who controlled the
output.
• 3 inputs with customizable alarm texts for notication on gate state or in case it gets jammed.
• Periodic self-test notication by SMS text message to administrator phone number.
2. TECHNICAL SPECIFICATIONS
2.1. Electrical and Mechanical Characteristics
Supply voltage ...............................................................10-24V 50Hz/60Hz ~ 200mA max / 10-24V 200mA max
Current used in idle state .............................................up to 50mA
Modem frequency .........................................................ESIM120 2G - 850/900/1800/1900MHz; ESIM320 3G/2G EU - 900/1800/2100MHz;
ESIM320US 3G USA - 850/1900MHz
Number of outputs .......................................................2
Output type....................................................................Relay; NO (normally-open) or NC (normally-closed) - congurable
Maximum commuting output values .........................24V 50Hz/60Hz ~ 0,5A / 24V 1A
Number of low-level (negative) inputs .....................2
Number of high-level (positive) inputs .....................1
Low-level (negative) input value range ....................0... 16V -0.8... -0.4mA
High-level (positive) input value range.....................5... 50V 0.17 .... 1.7mA
Default inputs connection type .................................NO (normally-open)
Degree of protection ....................................................Complies with IP 20
Dimensions ....................................................................87x107x29mm (3.43x4.21x1.14in)
Operating temperature range ....................................-20…+55 °C (-4... +131°F )
Humidity .........................................................................0-90% RH @ 0... +40°C (0-90% RH @ +32... +104°F) (non-condensing)
6
6 EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
2.2. Main Unit, LED Indicator and Connector Functionality
1
AC/DC RELAY1RELAY2 COM Z5 Z4 Z3 Z2 Z1
ANT
MIC
USB
F1
SIM CARD
MO D E M
SIM STAT
NETW
DEF
Main Unit Functionality
ANT Antenna SMA type connector
USB Mini USB port
SIM CARD SIM card slot / holder
MODEM ESIM120 -850/900/1800/1900 MHz modem; ESIM320 -
850/900/1800/1900/2100 MHz modem
MIC N/A
SIM STAT Red LED, indicating SIM card status
NETW Green LED, indicating signal strength
DEF Pins for restoring default settings
F1 0.5A fuse
Connector Functionality
AC/DC Power supply terminals
RELAY1 Output C1 terminal
RELAY2 Output C2 terminal
COM Common terminal
Z5 N/A
Z4 N/A
Z3 Low-level (negative) input terminal
Z2 High-level (positive) input terminal
Z1 Low-level (negative) input terminal
7
7EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
LED Indicator Functionality
SIM STAT indication SIM card status
OFF No mains power / Successfully connected to GSM/3G network
Steady ON SIM card is attempting to connect to the GSM/3G network / SIM card is not present / PIN code
enabled
NETW indication Signal strength
OFF No GSM/3G signal
Flashing every 1 sec. Poor
Flashing several times per sec. Medium
Steady ON Excellent
2.3. Wiring Diagrams
General wiring
ESIM120/ESIM320
AC/DC
Power
supply
GATE
AUTOMATION
DEVICE
RELAY2RELAY1 COM Z3 Z2 Z1
+
-
2
Example of ESIM120/ESIM320 system wiring to gate automation device
FO Fault output; open
collector type
+24V Power supply
output for powering
aux. equipment
Pulse input
GND Common terminal
ESIM120/ESIM320 GATE AUTOMATION DEVICE
AC/DC RELAY1RELAY2 COM Z5 Z4 Z3 Z2 Z1 F0 +24vGND
3
8
8 EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
3. INSTALLATION
The system should be installed indoors, in stationary environment ONLY.
For the connection of input/output terminals, use 0.50 mm
2
(0.02in
2
) thread unshielded cable of up to 100m (328.08ft) length.
1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for more details).
2. Connect the antenna. Based on the type of antenna supplied with ESIM120/ESIM320 unit, follow the recommendations for the anten-
na installation:
Antenna
4
Never install in the following
locations:
inside the metal cabinet
closer than 20cm (7.87in) from
the power lines
3. Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps.
4. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM120/ESIM320 system.
5
6
5. Power up the system and wait until indicator SIM STAT lights up indicating SIM card status.
6. Once the indicator SIM STAT lights OFF, the illuminated indicator NETW lights up indicating that the system has successfully connected
to GSM/3G network. To nd the strongest signal, position the antenna and follow the indications provided by NETW indicator (see 2.2.
Main Unit, LED Indicator and Connector Functionality for more details).
7. Change the system language if necessary (see 6. SYSTEM LANGUAGE for more details).
8. Change the default SMS password (see 7. SMS PASSWORD for more details).
9. Set the phone number for Admin 1 (see 8. ADMINISTRATOR PHONE NUMBERS for more details).
10. Set system date and time (see 9. DATE AND TIME for more details).
11. Once the system is fully congured, it is ready for use. However, if you fail to receive a reply by SMS text message from the system,
please check the SMSC (Short Message Service Center) phone number. For more details regarding the SMS center phone number,
please refer to 16.2. SMSC (Short Message Service Center) Phone Number.
ATTENTION: ESIM120 is NOT compatible with pure 3G SIM cards. Only 2G SIM cards and 3G SIM cards with 2G/GSM prole enabled are
supported. Meanwhile, ESIM320 is compatible with any SIM card and supports both 2G and 3G connections. For more details, please
contact your operator.
ATTENTION: We also recommend you to disable call forwarding, voice mail/text message reports on missed/busy calls and
similar services that might cause incorrect system operation. Please contact your operator for more details on these services and how
to disable them.
NOTE: For maximum system reliability we recommend you do NOT use a Pay As You Go SIM card. Otherwise, in the event of insucient
credit balance on the SIM card, the system would fail to make a phone call or send SMS text messages.
NOTE: We advise you to choose the same SIM provider for your system as for your mobile phone. This will ensure the fastest, most
reliable SMS text message delivery service and phone call connection.
NOTE: Even though the installation process of ESIM120/ESIM320 is not too complicated, we still recommend to perform it by a person
with basic knowledge in electrical engineering and electronics to avoid any system damage.
9
9EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
4. GENERAL OPERATIONAL DESCRIPTION
When a phone call is made to the phone number of the SIM card inserted in ESIM120/ESIM320, the system will verify if the caller’s phone
number exists in the device database. If the caller is one of the 5 administrators or the phone number belongs to one of the 2000 database
users, the system will reject the phone call, thus making the phone call free of charge, and open the gate. If the phone number is not recog-
nized, the system will reject the phone call and ignore it. The gate controller can also control your gate automatically in accordance with the
scheduled time or by sending an SMS text message from the administrator’s phone number.
By connecting a sensor to one of the 3 inputs, the administrators can receive SMS text messages regarding the gates that failed to close
during the set time period.
User/Admin
ESIM120/ESIM320
CALL
7
5. CONFIGURATION METHODS
5.1. SMS Text Messages
In this document the underscore character ”_” represents one space character. Every underscore character must be re-
placed with a single space character. There must be no spaces or other unnecessary characters at the beginning and at the
end of the SMS text message.
SMS
In order to congure and control the system by SMS text message, send the text command to the ESIM120/ESIM320 system
phone number from one of the listed administrator phone numbers. The structure of SMS text message consists of 4-digit
SMS password (the default SMS password is 0000 – four zeros), the parameter and value. For some parameters the value
does not apply e. g. STATUS. The variables are indicated in lower-case letters, while a valid parameter value range is indicated
in brackets.
5.2. ELDES Conguration Tool Software
Cong
Tool
Software ELDES Conguration Tool is intended for the gate controller ESIM120/ESIM320 conguration locally via USB port or
remotely via GPRS network connection. This software simplies system conguration process by allowing to use a personal
computer in the process. Before starting to use ELDES Conguration Tool software, please read the user guide provided in the
software’s HELP section.
ELDES Conguration Tool is freeware and can be downloaded from eldesalarms.com
NOTE: ELDES Conguration Tool software is secured with SMS password. The default SMS password is 0000 (see 7. SMS PASSWORD).
5.2.1. Remote Connection
ATTENTION: When remote connection session is initialized (i.e. when you send an SMS text command and receive the answer from the
system), then ELDES Cloud Services feature will NOT work and becomes inaccessible until the remote connection session is over.
ELDES Conguration Tool software provides remote system conguration ability via Internet using one of the following methods:
ELDES proxy server (recommended). The connection can be established on the system via GPRS network.
Running TCP/IP server on ELDES Conguration Tool (advanced). The connection can be established on the system via GPRS network.
In order to start using the remote conguration feature, please run the step-by-step wizard and follow the steps provided in the start page
of ELDES Conguration Tool software. Please, note that it will be necessary to send an SMS text message to the system’s phone number
in order to initiate the remote connection. By following the steps you will be instructed on what text must be sent to the system’s phone
number in such case (see the SMS command below).
Start the connection
SMS text message content:
ssss_STCONFIG
Value: ssss – 4-digit SMS password.
Example: 1111_STCONFIG
5.2.2. Ending the Remote Connection Session
After the system conguration is complete, use one of the following methods to end the conguration process:
• Click Disconnect or Stop button and close ELDES Conguration Tool software;
• The session will automatically expire in 20 minutes. Before the last 5 minutes, the software will oer the user to extend the session
for another 20 minutes.
• Alternatively, the connection with the server can be terminated at any time by sending an SMS text message.
Terminate the
connection
SMS text message content:
ssss_ENDCONFIG
Value: ssss – 4-digit SMS password.
Example: 1111_ENDCONFIG
Once the session is expired or terminated, the system will reply with an SMS text message conrming the end of the session.
10
10 EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
6. SYSTEM LANGUAGE
The system comes equipped with a multiple languages for communication with the administrator by SMS text messages. The default sys-
tem language depends on the rmware, which is based on the customer’s location.
List of currently available system languages:
• English
• Estonian
• German
• Lithuanian
• French
• Slovak
Set system language
SMS
SMS text message content:
LN
Value: LN – language index; range – [EN – English, EE – Estonian, DE – German, LT – Lithua-
nian, FR – French, SK – Slovak].
Example: LT
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
NOTE: To change the language once the system has already been congured, you need to reset the device to the default conguration. For
more details on how to do this, please refer to 20.2. Restoring Default Parameters.
7. SMS PASSWORD
For security reasons, the system uses the following type of password:
SMS password – 4-digit password used for system conguration and control from administrator phone number by SMS text mes-
sages and logging in to ELDES Conguration Tool software . By default, SMS password is 0000, which MUST be changed (device
will not reply to any of SMS messages until SMS password is changed!)!
Set SMS password
SMS
SMS text message content:
wwww_PSW_ssss
Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range –
[0001... 9999].
Example: 0000_PSW_1111
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
NOTE: The system rejects the SMS text messages containing wrong SMS password even from a listed administrator phone number.
11
11EN
ELDES GATE CONTROLLER ESIM120/320 User Manual v.1.1
8. ADMINISTRATOR PHONE NUMBERS
The system supports up to 5 administrator phone numbers identied as Admin 1 through 5. When the phone number is set, the administra-
tor will be able to congure and control the system by SMS text messages as well as by free of charge phone call and receive the input alarm
SMS text messages from the system (see 14.1. Input Names and Alarm Notication). The system allows to assign output C1, output C2
or both outputs (simultaneous control) to a certain administrator.
By default, the system accepts incoming calls and SMS text messages from any phone number. Once the administrator phone number is
listed, the system will ignore any incoming calls and SMS text messages from a non-listed phone number as well as it will reject the SMS
text messages containing wrong SMS password even from a listed administrator phone number. For more details on how to enable output
control from a non-listed phone number, please refer to 11.5. Output Control from any Phone Number.
To set Admin 1 phone number is mandatory (using the device without entered administrator number is forbidden!), while the other 4 are
optional. The supported phone number format is the following:
• International (w/o plus) – The phone numbers must be entered starting with an international country code in the following format:
[international code][area code][local number], example for UK: 44170911XXXX1.
Set administrator
phone number
SMS
SMS text message content:
ssss_NRas:ttteeellnnuumm
Value: ssss – 4-digit SMS password; as – administrator phone number slot, range – [1... 5];
ttteeellnnuumm – up to 15 digits administrator phone number.
Example: 1111_NR1:44170911XXXX1
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
View administrator
phone numbers
SMS
SMS text message content:
ssss_HELPNR
Value: ssss – 4-digit SMS password.
Example: 1111_HELPNR
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Assign output
(-s) to individual
administrator
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Delete administrator
phone number
SMS
SMS text message content:
ssss_NRas:DEL
Value: ssss – 4-digit SMS password; as – administrator phone number slot, range – [2... 5].
Example: 1111_NR2:DEL
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
ATTENTION: NEVER set a phone number of the device’s SIM card as an administrator phone number!
ATTENTION: Once Admin 1 phone number is set, the system will allow only to modify it.
ATTENTION: Multiple administrator phone numbers can be set by a single SMS text message, Example: 1111_NR1:44170911XXXX1_
NR5:44170911XXXX2_NR2:44170911XXXX3_NR3: 44170911XXXX4
NOTE: Multiple administrator phone numbers can be deleted by a single SMS text message, Example: 1111_NR2:DEL_NR4:DEL_
NR3:DEL
NOTE: The administrator can control any output by SMS text message regardless of the output assigned to the administrator phone number
(see 11.3. Output Control by SMS Text Message).
NOTE: By default, the system is restricted to send out up to 25 SMS text messages daily and up to 400 SMS text messages monthly. For
more details on SMS text message delivery restriction management, please refer to 16.1. SMS Text Message Delivery Restrictions
For more details on output control, please refer to 11. OUTPUTS.