Elation Professional EVC MH User Manual

EVC MH LED
EVC MH LED General Information
Unpacking: Thank you for purchasing the EVC MH LED by Elation
Professional®. Every EVC MH LED has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping.
If the carton appears to be damaged, carefully inspect your xture for
any damage and be sure all equipment necessary to operate the unit has arrived intact. In the event damage has been found or parts are missing, please contact our toll free customer support number for fur­ther instructions. Please do not return this unit to your dealer without
contacting customer support rst.
Introduction: The EVC MH LED by Elation Professional® is a unique
twelve channel DMX controllable moving head video camera, designed to spotlight almost anything and project it onto a video wall or TV. An array of 48 total Cool and Warm White LED’s allow you to customize
to dierent skin tones and ambient light in a room so that the EVC MH
LED always projects the best images. The EVC MH LED is compact and light weight so that it is very discreet and easy to transport and mount. The EVC MH LED is ideal for use at corporate events, wedding receptions, nightclubs, school dances, or anywhere that you wish to put someone in the spotlight.
3/12
User Instructions
tomer support line, to provide help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.americandj.com for any com­ments or suggestions. Service Hours are Monday through Friday 8:00
a.m. to 4:30 p.m. Pacic Standard Time.
Voice: (323) 582-3322
Fax: (323) 832-9142
E-mail: support@elationlighting.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
Elation Professional - www.elationlighting.com - EVC MH LED Instruction Manual Page 2
EVC MH LED General Instructions
EVC MH LED Safety Precautions
To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
EVC MH LED Features
• LED Moving Head Video Camera
• DMX-512 Protocol Compatible (12 DMX Channels)
• Digital Display for Address and Function Setting
EVC MH LED Warranty Registration
The EVC MH LED carries a two year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. num­ber must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All pack­ages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
EVC MH LED Handling Precautions
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact Elation Professional®.
During operation the housing may become extremely hot. Avoid touching the unit with bare hands while in use.
ized modication to this unit.
Elation Professional - www.elationlighting.com - EVC MH LED Instruction Manual Page 3
For Your Own Personal Safety, Please Read and Understand This
Manual Completely Before You Attempt To Install Or Operate
This Unit!
• To reduce the risk of electrical shock or re, do not expose this unit
rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt-
age for your unit.
• Do not attempt to operate this unit if the power cord has been
frayed or broken.
• Do not attempt to remove or break o the ground prong from
the electrical cord. This prong is used to reduce the risk of electrical
shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user
serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out-
doors voids all warranties.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep-
tacles, and the point where they exit from the appliance.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 15 for cleaning details.
• Heat -This fixture should be situated away from heat sources such
as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. Objects have fallen, or liquid has been spilled into the appliance.
B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits
a marked change in performance.
Elation Professional - www.elationlighting.com - EVC MH LED Instruction Manual Page 4
EVC MH LED Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
EVC MH LED Set Up
Power Supply: The Elation Professional® EVC MH LED contains a
automatic voltage switch, which will auto sense the voltage when it is plugged into a power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. A DMX
DMX Linking: DMX is a language allowing all makes and models
of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the first fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): The EVC MH LED is a 12 channel DMX unit. The DMX
address is set electronically using the controls on the front panel of the unit. Your unit and your DMX controller require
a approved DMX-512 110 Ohm Data cable for data input and data output (Figure 1). We recommend
Accu-Cable DMX cables. If you are making your
own cables, be sure to use standard 110-120 Ohm
shielded cable (This cable may be purchased at almost all professional sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Elation Professional - www.elationlighting.com - EVC MH LED Instruction Manual Page 5
Figure 1
Notice: Be sure to follow gures two and three when making your own
COMMON
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
Figure 4
XLR Male Socket
1 Ground
DMX512 OUT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
DMX +
DMX -
1 Ground
3 Hot
Figure 3
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-)
Elation Professional - www.elationlighting.com - EVC MH LED Instruction Manual Page 6
and PIN 3 (DMX +) of the last fixture.