Elation Professional DMX-512 User Manual

0 (0)

USER INSTRUCTIONS

 

 

MIDI

 

DMX-512

 

 

CAPABLE

 

 

 

 

©Elation Professional®

 

 

4295 Charter Street

rev. 4/04

Los Angeles Ca. 90058

www.elationlighting.com

 

 

 

TABLE OF CONTENTS

 

FLOW CHART...........................................................................................

1

CONTROLS & FUNCTIONS.......................................................................

2

REAR CONTROLS.........................................................................................

4

DMX-512 ADDRESSING..............................................................................

4

PROGRAMMING SCENES........................................................................

8

PROGRAMMING SCENES REVIEW:.......................................................

9

SCENE

COPY:.......................................................................................

10

SCENE

EDITING:...................................................................................

10

DELETE SCENE :.................................................................................

10

RESET ALL SCENES:............................................................................

10

COPY BANK OF SCENES:.................................................................

11

DELETE BANK OF SCENES:................................................................

11

PROGRAMMING CHASES.....................................................................

12

EDITING CHASES....................................................................................

12

INSERT A STEP:....................................................................................

12

DELETE A STEP:....................................................................................

13

DELETE A COMPLETE CHASE:...........................................................

13

DELETE ALL CHASES:..........................................................................

13

PLAYBACK SCENES & CHASES...............................................................

14

MANUAL RUN SCENES:....................................................................

14

MANUAL RUN CHASES:....................................................................

14

AUTO RUN SCENES:..........................................................................

14

AUTO RUN CHASES:.........................................................................

15

MUSIC

RUN SCENES:........................................................................

15

MUSIC RUN CHASES:..........................................................................

15

MIDI OPERATION.......................................................................................

16

TROUBLE SHOOTING.................................................................................

18

CABLE TERMINATION................................................................................

18

DIP SWITCH DMX ADDRESS CHARTS........................................................

20

 

Specifications are subject to change without notice!

 

Elation Professional DMX-512 User Manual

FLOW CHART

 

 

 

6

7

8 9

 

10

This is the order you program the DMX Operator.

5

 

Chase1

Chase2

Chase3

 

Chase4

 

Chase5

Chase6

BLACKOUT

 

 

4

 

BANK

Program

Midi Rec

Auto

Del

Music Bank-copy

Tapsync Display

FADETIME

12 11

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

ADDRESS

 

 

8

PageA

PageB

 

Page Select

 

 

 

SPEED

1314

 

FIXTURES

 

 

 

 

 

 

 

 

 

 

 

 

pg 4 to 7

 

 

 

8

16

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

PROGRAM SCENES

 

 

 

7

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(up to 240)

 

 

6

 

 

 

 

 

 

 

 

 

 

pg 8 & 9

 

 

 

6

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLAYBACK SCENES

PROGRAM CHASES

2

SCENES

5

5

13

 

 

 

 

 

 

15

 

 

4

 

 

 

 

 

 

 

 

 

8 AT A TIME

up to 6 of 240 scenes

 

 

 

12

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

30 BANKS OF 8

pg 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pg 14

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

11

 

 

 

 

 

 

 

 

PLAYBACK CHASES

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

2

10

 

 

 

 

 

 

 

 

up to 240

 

 

 

 

 

 

 

 

 

 

 

 

 

pg 14

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 9

 

 

 

 

 

 

 

 

 

 

SCANNERS

1 7

8

3 9

 

4 10

 

5 11

 

6 12

 

 

 

1

2

 

 

 

 

Elation Professional®

- DMX OPERATOR User Manual page 1

CONTROLS & FUNCTIONS

1. SCANNER BUTTONS - Used to Select any or all of 12 fixtures This is what selects which DMX channels go to the fixtures.

Scanner 1 controls Channel 1 to 16 Scanner 2 controls Channel 17 to 32

See addressing of fixtures on page 7 for more information

2. SCENE BUTTONS - Used to store Scenes in program mode or playback your scenes in playback mode

3. LCD DISPLAY - Displays values and settings depending on the chosen function.

4. BANK BUTTONS ( OR)- Selects which Bank you want to use. (there are 30 selectable banks total.)

5.CHASE - Used to select chases (1-6).

6.PROGRAM - Used to activate program mode Display blinks when activated.

7.MIDI / REC - Used to control MIDI operation or to Record each step for Scene and Chases.

8.AUTO/DELSelect AUTO speed in chase mode or Deletes Scenes and or chases .

9.MUSIC / BANK COPYUsed to trigger sound activation in Chase

mode or to copy a bank of scenes from one to another in Program Mode

10.BLACKOUT - Disables or enables all channel outputs

11.TAP SYNC / DISPLAY - In Auto Chase mode used to change

rate of chase also to change LCD Display in Manual Chase.

12. FADE TIME SLIDER - Used to adjust the FADE TIME. Fade Time is the amount of time it takes the DMX Operator

to completely change from one scene to another. For example; if the fade time slider is set to 0 (zero) a scene change will be instant. If the slider is set to ‘30s’ it will take the DMX Operator 30 seconds to complete the change from one scene to the next.

13. SPEED SLIDER - Used to adjust the rate of chase speed in Auto Mode.

14. PAGE SELECT - Used to select faders between PAGE A (1-8) and PAGE B (9-16) of each Scanner Button

15. FADERS (1-8) - Used to adjust the intensity from 0% to 100% or DMX output level from 0 to 255 of each channel

REAR CONTROLS

16.MIDI INReceives MIDI data.

17.DMX POLARITY SELECTChanges the polarity setting of the DMX

output.

18.DMX OUTUsed to send DMX signal to fixtures or Packs.

19.DC INPUTAccepts a DC 9~12V, 300 mA minimum, power supply.

16

 

17

18

 

19

MIDI IN

DMX POLARITY

DMX OUT

 

DC INPUT

 

 

SELECT

 

 

 

 

1:GND

1:GND

 

-

+

 

2:DATA -

2:DATA +

 

 

 

 

3:DATA +

3:DATA -

 

 

 

 

 

 

+9V-+12V 300mA Min.

 

 

 

 

DMX512 ADDRESSING

WHEN ADDRESSING YOUR FIXTURES FOLLOW THE STARTING ADDRESS IN THIS BOOK NOT THE ADDRESSING FOUND IN YOUR FIXTURE MANUAL

DMX 512 is a type of protocol that sends out up to 512 multiplex channels at once down a common cable. Each channels has a value from 0 to 255. You set the address for each receiver(fixture) by using Dip switches or some type of digital readout

Each Dip switch has an ADDRESS based on binary code.

Dip switch

#1

#2 #3 #4

#5

#6

#7

#8 #9

Value

1

2

4

8

16

32

64

128 256

YOU SELECT THE ADDRESS WANTED BY ADDING THE TOTAL OF DIP SWITCHES ON.

Dip switch #10 is not used with DMX but normally to select some Function ie: Master / Slave, Sound Activation or to receive DMX Control.

Elation Professional® - DMX OPERATOR User Manual page 3

Elation Professional® - DMX OPERATOR User Manual page 4

Most fixtures start receiving on the address selected

EXAMPLE:

Setting ADDRESS at 1 unit starts at CHANNEL 1

Dip switch

# 1 on

 

 

 

 

Setting ADDRESS for

Setting ADDRESS for

17 unit starts at

 

49 unit starts at

 

CHANNEL 17

 

CHANNEL 49

 

Dip switch

# 1 =

1

Dip switch

# 1 =

1

# 5 = +16

5 =

16

 

=

17

6 =

32

 

 

 

 

=

49

DIP SWITCH DMX ADDRESSDIP SWITCH DMX ADDRESS

2

8

32

128

2

8

32

128

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

4

 

 

16

64

256

1

 

4

 

 

16

 

64

256

 

 

Dip switch total = 17

 

Dip switch total = 49

 

unit starts at

 

 

 

 

 

 

unit starts at

 

 

 

 

 

 

 

CHANNEL 17

 

 

 

 

 

 

CHANNEL 49

 

 

 

 

 

 

Some units start receiving one more than the ADDRESS selected. Example: Elation Patend Light, Elation Professional Mighty Scan

EXAMPLE:

Setting ADDRESS at 0 unit starts at CHANNEL 1 all Dip switches OFF

Setting ADDRESS for

Setting ADDRESS for

17

49

Dip switch # 5 = 16

Dip switch # 5 = 16

= 16

6 = 32

 

= 48

unit starts at 17

unit starts at 49

DIP SWITCH DMX ADDRESS DIP SWITCH DMX ADDRESS

2

8

32

 

128

 

 

 

2

8

32

 

128

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8 9 10

1

2 3 4 5 6 7 8 9 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

4

 

 

16

64

256

 

1

 

 

4

 

 

16

 

64

 

256

 

Dip switch total = 16

Dip switch total = 48

unit starts at

unit starts at

CHANNEL 17

CHANNEL 49

Elation Professional® - DMX OPERATOR User Manual page 5

Elation Professional® - DMX OPERATOR User Manual page 6

Loading...
+ 8 hidden pages