Edwards Acoustic Enclosure, NRD797000, NRY5C0000, NRD318000, NRD317000 Instruction Manual

NRD317880
Issue A
Original Instructions
Instruction Manual
Acoustic Enclosure for nXDS/XDS Scroll Pumps and EM/RV Rotary Vane
Pumps
Description Electrical Supply Item Number
nXDS/XDS Acoustic Enclosure 110-120 V 50/60 Hz NRY5C0000
RV/EM Acoustic Enclosure 200-240 V 50/60 Hz NRD318000
RV/EM Acoustic Enclosure 110-120 V 50/60 Hz NRD317000
This product has been manufactured under a quality system registered to ISO9001
Declaration of Conformity
We, Edwards, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
nXDS/XDS Acoustic Enclosure 200-240 V 50/60 Hz NRD797000 nXDS/XDS Acoustic Enclosure 110-120 V 50/60 Hz NRY5C0000 RV/EM Acoustic Enclosure 200-240 V 50/60 Hz NRD318000 RV/EM Acoustic Enclosure 110-120 V 50/60 Hz NRD317000
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use. General Requirements
EN12100:2010 Safety of machinery. General principles for design. Risk
assessment and risk reduction. EN50581:2012 Technical Documentation for the Assessment of Electrical and Electronic Products with respect to the Restriction of Hazardous
Substances and fulfils all the relevant provisions of 2006/95/EC Low Voltage Directive
2012/19/EU Waste from Electrical and Electronic Equipment (WEEE) Directive 2011/65/EU* Restriction of Certain Hazardous Substances (RoHS) Directive
* i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive). The RoHS Directive does not legally apply to industrial vacuum equipment until July 2019 (July 2017 for instruments).
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
20.11.2014, Burgess Hill
Peter Meares –Technical Support Manager Date and Place
P200-08-880 Issue A
© Edwards Limited 2014. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
NRD317880 Issue A
Contents
Section Page
1 Introduction ....................................................................................... 1
1.1 Scope and definitions ................................................................................................... 1
2 Technical data .................................................................................... 2
2.1 Specifications ............................................................................................................. 2
3 Installation ......................................................................................... 3
3.1 Safety ......................................................................................................................3
3.2 Installing the XDS Acoustic Enclosure ................................................................................. 4
3.3 Installing RV EM Acoustic Enclosure ................................................................................... 5
4 Operation .......................................................................................... 8
4.1 Safety ......................................................................................................................8
4.2 Over temperature alarm ................................................................................................ 8
4.3 Buzzer test ................................................................................................................ 8
4.4 Pump Monitoring ......................................................................................................... 8
5 Maintenance ....................................................................................... 9
5.1 General .................................................................................................................... 9
5.2 Servicing .................................................................................................................. 10
5.3 Cleaning ..................................................................................................................10
6 Disposal .......................................................................................... 11
For return of equipment, complete the HS Forms at the end of this manual.
Illustrations
Figure Page
1 Specifications of XDS and RV/EM pumps ............................................................................. 2
2 Inserting XDS pump into Acoustic Enclosure ......................................................................... 4
3 Locating left hand panel on side of pump ........................................................................... 4
4 Fitting second cover to right hand side of pump ................................................................... 4
5 Attaching inlet and exhaust fittings .................................................................................. 5
6 Locating first panel on left hand side of pump ..................................................................... 6
7 Fitting second cover to right hand side of pump ................................................................... 6
8 Fitting end cover ......................................................................................................... 6
9 Removing front panel to view sight glass ............................................................................ 9
10 Removing panel to gain access to filler cap ......................................................................... 9
gp/0260/11/14
NRD317880 Issue A
Page ii © Edwards Limited 2014. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
Tables
Table Page
1 Pump noise levels ........................................................................................................ 2
Associated publications
Publication title Publication number
Vacuum pump and vacuum system safety P400-40-100
© Edwards Limited 2014. All rights reserved. Page 1 Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
NRD317880 Issue A
1Introduction
1.1 Scope and definitions
The Acoustic Enclosure is designed to be used in an industrial or laboratory environment. All Edwards XDS and nXDS scroll pumps will fit the nXDS/XDS Acoustic Enclosure and all RV and EM pumps up to E2M28 will fit the RV/EM Acoustic Enclosure.
The enclosure is designed to slot together without removable fixings and so requires no tooling to assemble or dismantle it. It is powered by a power cable fitting into an IEC 320 socket.
Note: The power cable for the pump is connected to its own supply. This supply should have an external means of
isolation and not rely upon the on/off switch located on the pump.
Read this manual before installing and operating the Acoustic Enclosure. Important safety information is highlighted as WARNING and CAUTION instructions; these instructions must be obeyed. The use of WARNINGS and CAUTIONS is defined below.
CAUTION
Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment and process.
The following warning labels appear on the Acoustic Enclosure:
WARNING
Warnings are given where failure to observe the instruction could result in injury or death to people.
Warning - refer to accompanying documentation.
Warning - risk of electric shock.
Loading...