Edwards iXH1210H, iXH1210HT, iXH1220H, iXH1220HT, iXH1220HTX Instruction Manual

...
M561-00-880
Issue C Original
Instruction Manual
iXH, iXL and pXH Dry Pumping Systems
iXH and pXH Dry Pumping Systems
Booster Size
Low Voltage
0 = None 1 = 600G 2 = r 3 = 1200 4 = 1800 5 = 3000 6 = 4500 7 = 6000
Dry Pump
Standard
0 = None (pXH) 1 = 100 2 = 200 3 = 300 4 = r 5 = r 6 = r 7 = r
TMS System
0 = Standard 1 = T-Variant 2 = T-Variant + heated booster 3 = r 4 = r 5 = r
Gas Module
0 = None (pXH) 6 = Single Mode + 1 = Loadlock (44 slm flow) (4 slm flow) 2 = Single Mode 7 = Single Mode + (44 slm flow) (96 slm flow) 3 = Single Mode 8 = Single Mode + (96 slm flow) (133 slm flow) 4 = Single Mode 9 = Single Mode + (133 slm flow) (204 slm flow) 5 = Single Mode A = Multi Mode (204 slm flow) (44 slm flow)
B = Multi Mode (96 slm flow) C = Multi Mode (133 slm flow) D = Multi Mode
(204 slm flow)
Exhaust
0 = r 1 = Standard without check valve. 2 = r 3 = Standard with check valve.
Seals
0 = r 1 = r 2 =Standard
Pump Motor
0 = None 1 = 4.5 kW 2 = 7.5 kW 3 = 11 kW
Booster Motor
0 = None 1 = 1.9 kW 2 = 4.5 kW 3 = 7.5 kW 4 = r
High Voltage
A = None B = 600G C = r D = 1200 E = 1800 F = 3000 G = 4500 H = 6000
Harsh
A = 100 B = 200 C = 300 D = 450 E = 500
Where r = reserved for future use
Special Features
0 = None 1 = Application Specific 2 = Application Specific 3 = Application Specific 4 = Application Specific 5 = Application Specific 6 = Application Specific 7 = Application Specific 8 = Application Specific 9 = Application Specific
iXL Dry Pumping Systems
ASXXXXXXXX00
Where r = reserved for future use
Booster Size
Low Voltage 0 = None
1 = r 2 = r 3 = r 4 = 1800 5 = 3000
High Voltage A = None
B = r C = r D = r E = 1800 F = 3000
TMS System
0 = Standard 1 = r
Exhaust
0 = r
1 = Standard
without
check valve.
2 = r
3 = r
Seals
0 = r 1 = r 2 = Standard 3 = EES
Pump Motor
0 = None 1 = 4.5 kW 2 = 7.5 kW 3 = 11 kW
Booster Motor
0 = None 1 = r 2= 4.5 kW 3 = 7.5 kW 4 = r
Gas Module 0 = None
1 = Loadlock (4 slm flow) 2 = r 3 = r 4 = r
Dry Pump 0 = None
1 = r 2 = r 3 = 250 4 = r 5 = 500 6 = 750
P200-02-320 Issue J
Declaration of Conformity
We, Edwards Limited, Crawley Business Quarter, Manor Royal, Crawley, West Sussex RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
Low Volt Systems High Volt Systems (200 - 230V) (380 - 460V)
iXH100 AC010xy21000 ACA10xy21000 iXH200H AC0B0xy22000 ACAB0xy22000 iXH610 AC110xy21100 ACB10xy21100 iXH1210 AC310xy21200 ACD10xy21200 iXH1210H AC3A0xy22200 ACDA0xy22200 iXH1210HT AC3A1xy22200 ACDA1xy22200 iXH1220H AC3B0xy22200 ACDB0xy22200 iXH1220HT AC3B1xy22200 ACDB1xy22200 iXH1220HTX AC3B2xy22200 ACDB2xy22200 iXH1820 AC420xy22200 ACE20xy22200 iXH1820H AC4B0xy22200 ACEB0xy22200 iXH1820T AC421xy22200 ACE21xy22200
Where x = 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C or D depending on gas module type Where y=1 means 'no check valve' and y=3 means 'check valve supplied'
to which this declarat ion relates is in conformity with the following standard(s) or other normative document(s):
EN1012-2: 1997 Compressor and Vacuum Pumps Safety Requirements; Part 2 - Vacuum Pumps. EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement, Control and
Laboratory Use; Part 1 – General Requirements.
EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory use -
EMC requirements (Industrial Location Immunity – Class A Emissions)
EN50581:2012 Technical Documentation for the Assessment of Electrical and Electronic Products
with respect to the Restriction of Hazardous Substances
ANSI/UL 61010-1 and CAN/CSA-C22.2 No. 61010-1, 2
nd
Edition July 12, 2004, including revision July 22, 2005 ­Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General Requirements
SEMI S2-0709 - Environmental, Health, and Safety Guideline for Semiconductor Manufacturing Equipment
when installed in accordance with the instruction manual supplied with the pump, following the provisions of:
2006/95/EC Low Voltage Directive. 2004/108/EC Electromagnetic Compatibility Directive. 2006/42/EC Machinery Safety Directive.
2011/65/EU* Restriction of Certain Hazardous Substances (RoHS) Directive
* i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive) . The RoHS Directive does not legally apply to industrial vacuum equipment until July 2019 (July 2017 for instruments).
Note: This declaration covers all product serial numbers from the date this Declaration was signed
onwards.
22.10.2013, Burgess Hill
Mr Mark Hope, Global Technical Support Manager Date and Place
This product has been manufactured under a quality system certifie
d
to ISO9001:2008
P200-02-720 Issue K
Declaration of Conformity
We, Edwards Limited, Crawley Business Quarter Manor Royal, Crawley, West Sussex RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
Low Volt Systems High Volt Systems
(200-230V) (380-460V)
iXH3030 AC530xy22300 ACF30xy22300 iXH3030T AC531xy22300 ACF31xy22300 iXH3030TX AC532xy22300 ACF32xy22300 iXH3045H AC5D0xy23310 ACFD0xy23310 iXH4545HT AC6D1xy23300 ACGD1xy23300 iXH4545HT - ACGD1B123390 iXH6045H AC7D0xy23300 ACHD0xy23300 iXH6045H AC7D02123310 ACHD02123310 iXH6045HT AC7D1xy23300 ACHD1xy23300 iXH450H AC0D0xy23000 ACAD0xy23000 pXH4500 AC6000120300 ACG000120300 pXH4500 - ACG000120310 pXH6000 AC7000120300 ACH000120300 iXL500Q AS450zy23300 ASE50zy23300 iXL500R AS550zy23300 ASF50zy23300
Where x = 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C or D depending on gas module type Where y = 1 means 'no check valve' and y=3 means 'check valve supplied' Where z = 1, 2, 3, 5, A or B depending on gas module type for iXL
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2: 1997 Compressor and Vacuum Pumps Safety Requirements. Part 2 - Vacuum Pumps EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory
Use. Part 1 – General Requirements. EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory use - EMC requirements (Industrial Location Immunity – Class A Emissions)
EN50581:2012 Technical Documentation for the Assessment of Electrical and Electronic Products
with respect to the Restriction of Hazardous Substances
ANSI/UL 61010-1 and CAN/CSA-C22.2 No. 61010-1, 2
nd
Edition July 12, 2004, including revision July 22, 2005 ­Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General Requirements
SEMI S2-0709 - Environmental, Health, and Safety Guideline for Semiconductor Manufacturing Equipment
when installed in accordance with the instruction manual supplied with the pump, following the provisions of:
2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive 2006/42/EC Machinery Safety Directive 2011/65/EU* Restriction of Certain Hazardous Substances (RoHS) Directive
* i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive). The RoHS Directive does not legally apply to industrial vacuum equipment until July 2019 (July 2017 for instruments).
Note: This declaration covers all product serial numbers from the date this Declaration was signed onwards.
22.10.2013, Burgess Hill
Mr Mark Hope, Global Technical Support Manager Date and Place
This product has been manufactured under a quality system certified to ISO9001:2008
This product has been manufactured under a quality system certified to ISO9001:2008
P200-06-000 Issue C
Declaration of Conformity
We, Edwards Limited, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
Low Volt Systems High Volt Systems (200-230V) (380-460V)
iXH500H AC0E0xy23000 ACAE0xy23000 iXH3050H AC5E0xy23310 ACFE0xy23310 iXH3050HTX AC5E2xy23300 ACFE2xy23300
iXH4550HT AC6E1xy23300 ACGE1xy23300 iXH6050H AC7E0xy23300 ACHE0xy23300 iXH6050HT AC7E1xy23300 ACHE1xy23300
Where x = 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C or D depending on gas module type
Where y = 1 means ‘no check valve’ and y = 3 means ‘check valve supplied’ to which this declaration relates is in conformity with the following standard(s) or other normative document(s) EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements.
Part 2 - Vacuum Pumps. EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use. Part 1 - General Requirements.
EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory
Use - EMC requirements. (Industrial Location Immunity
- Class A Emissions)
EN50581:2012 Technical Documentation for the Assessment of Electrical and Electronic Products
with respect to the Restriction of Hazardous Substances
ANSI/UL 61010-1 and CAN/CSA-C22.2 No. 61010-1, 2nd Edition July 12, 2004, including revision July 22, 2005 – Safety
Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1: General Requirements and fulfils all the relevant provisions of 2006/42/EC Machinery Directive
2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility (EMC) Directive 2011/65/EU* Restriction of Certain Hazardous Substances (RoHS) Directive
* i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive). The RoHS Directive does not legally apply to industrial vacuum equipment until July 2019 (July 2017 for instruments).
Note: This declaration covers all product serial numbers from the date this Declaration was signed onwards.
22.10.2013, Burgess Hill
Mr Mark Hope, Global Technical Support Manager Date and Place
P200-06-620 Issue B
Declaration of Conformity
We, Edwards Limited, Crawley Business Quarter, Manor Royal, Crawley, West Sussex RH10 9LW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s)
Low Volt Systems High Volt Systems
(200-230V) (380-460V)
iXL250Q AS43001x2300 ASE3001x2300 iXL750Q AS46001x4300 ASE6001x4300 iXL750R AS56001x4300 ASF6001x4300
Where x = 2 means 'standard booster oilbox evacuation' and x=3 means 'external booster oilbox evacuation'
to which this declaration relates is in conformity with the following standard(s) or other normative document(s)
EN1012-2: 1997 Compressor and Vacuum Pumps Safety Requirements. Part 2 - Vacuum Pumps EN61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory
Use. Part 1 – General Requirements. EN 61326-1: 2006 Electrical equipment for measurement, control and laboratory use - EMC requirements (Industrial Location Immunity – Class A Emissions)
ANSI/UL 61010-1 and CAN/CSA-C22.2 No. 61010-1, 2
nd
Edition July 12, 2004, including revision July 22, 2005 ­Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General Requirements
when installed in accordance with the instruction manual supplied with the pump, following the provisions of:
2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive 2006/42/EC Machinery Safety Directive
Note: This declaration covers all product serial numbers from the date this Declaration was signed onwards.
Mr Mark Hope, Global Technical Support Manager Date and Place
This product has been manufactured under a quality system certified to ISO9001:2008
22.10.2013, Burgess Hill
P601-01-100
Issue C Original
The Chinese regulatory requirement on the Control of Pollution Caused by Electronic Information Products No. 39 (also known as ‘China RoHS’) mandates that manufacturers of certain categories of electronic products sold in China after 1st March 2007 –
Mark the product and packagingDefine the Product’s Environment Protection Use Period (EPUP)Provide a Materials Content Declaration.
Product Labels
Packaging information
Environment Protection Use Period (EPUP)
This is the period in years during which the toxic or hazardous substances or elements contained in this product will not leak or mutate under normal operating conditions so that the use of such electronic information products will not result in any severe environmental pollution, any bodily injury or damage to any assets.
The Environmental Protection Use Period is 20 years for this product. For the purposes of EPUP, normal operating conditions are considered to be use in accordance with the product’s
instruction manual.
Materials Content Declaration for all iXH, iXL & pXH models
Product Product Label Meaning
All iXH, iXL500 and
pXH models
Indicates toxic or hazardous substance contained in at least
one of the homogeneous materials used for this part is
above the limit requirement in SJ/T11363-2006.
Environmental Protection Use Period is 20 years.
Pallet Overshipper Protection Pieces Support Braces
Recyclable Natural Wood Recyclable Cardboard Recyclable Polypropylene Recyclable Mild Steel
Part name
Toxic or Hazardous Substances and Elements
Lead (Pb) Mercury (Hg) Cadmium (Cd)
Hexavalent
Chromium (Cr (VI))
Poly brominated
biphenyls (PBB)
Poly bromi nat ed
diphenyl ethers (PBDE)
Motor (Mechanical Booster)
OO O O O O
Motor (pump) O O O O O O Pump & Booster O O O O O O Electronics and Controls O O X O O O Cooling System O O O O O O Purge System O O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in
SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006.
2020
NWNW
DJD 24/03/10
© Edwards Limited 2012. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
M561-00-880 Issue C
Contents
Section Page
1 Introduction .......................................................................................1
1.1 Scope and definitions ................................................................................................... 1
1.2 Applications ............................................................................................................... 2
1.3 Description ................................................................................................................ 2
1.4 Priority of control ........................................................................................................ 2
1.5 Active utility control .................................................................................................... 3
2 Technical data ....................................................................................5
2.1 General technical data .................................................................................................. 5
2.2 Performance data ........................................................................................................ 7
2.3 Loading data .............................................................................................................. 8
2.4 Nitrogen purge data ..................................................................................................... 9
2.5 Electrical data ...........................................................................................................11
2.6 Cooling-water data .....................................................................................................17
2.7 T variants ................................................................................................................20
2.8 Trac er gas analysis .....................................................................................................20
3 Installation ......................................................... .............................. 23
3.1 Locate the dry pumping system ......................................................................................24
3.2 Lubrication ...............................................................................................................25
3.3 Connect the dry pumping system to your vacuum/exhaust system .............................................25
3.4 Connect to your factory extraction system (optional) ............................................................27
3.5 Connect the nitrogen supply ..........................................................................................28
3.5.1 Flammable/pyrophoric materials ....................................................................................28
3.5.2 Gas purges ...............................................................................................................29
3.6 Leak-test the system ...................................................................................................29
3.7 Electrical supply ........................................................................................................29
3.7.1 Mains supply cable connection .......................................................................................31
3.8 Connect an additional RF earth (ground) (optional) ..............................................................35
3.9 Connect to your emergency stop circuit ............................................................................35
3.10 Connect and set up the cooling-water ..............................................................................36
3.11 Accessories ............................................................................................................... 37
3.12 Commission the system ................................................................................................37
3.13 Install additional safety equipment ..................................................................................38
4 Operation ........................................................................................ 39
4.1 Start-up ..................................................................................................................39
4.1.1 MicroTIM operation .....................................................................................................40
4.1.2 PDT operation ...........................................................................................................40
4.1.3 Front panel control operation ........................................................................................40
4.2 Status indicators ........................................................................................................40
4.3 Manual shut-down ......................................................................................................41
4.3.1 Shut-down modes .......................................................................................................41
4.3.2 MicroTIM operation .....................................................................................................41
4.3.3 PDT operation ...........................................................................................................41
4.3.4 Front panel control operation ........................................................................................41
4.4 Automatic shut-down ..................................................................................................42
4.5 Unplanned shut-down and alarms ....................................................................................43
4.6 Emergency stop .........................................................................................................44
4.7 Restart the pump after an emergency stop or automatic shut-down ..........................................44
4.8 Advanced control and monitoring ....................................................................................44
gea/0179/01/12
M561-00-880 Issue C
Page ii © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
5 Maintenance ..................................................................................... 45
5.1 Safety and maintenance frequency ..................................................................................45
5.2 Relocate the system for maintenance ...............................................................................46
5.3 Draining the cooling water ............................................................................................47
5.4 General maintenance ..................................................................................................48
5.5 Inspect the connections, pipelines, cables and fittings ..........................................................48
5.6 Gas module configuration .............................................................................................49
5.6.1 iXH single mode and single mode+ ...................................................................................49
5.6.2 Multi mode ...............................................................................................................49
5.6.3 iXL variants ..............................................................................................................50
5.7 System operating temperature configuration ......................................................................50
6 Transportation, storage and disposal ........................................................ 51
6.1 Transportation ..........................................................................................................51
6.2 Storage ...................................................................................................................51
6.3 Disposal ...................................................................................................................51
7 Service, spares and accessories .............................................................. 53
7.1 Introduction .............................................................................................................53
7.2 Service ....................................................................................................................53
7.3 Ordering accessories ...................................................................................................54
Appendix A1 Pump display terminal .................................................................. 57
A1.1 LEDs .......................................................................................................................57
A1.2 Pump start / stop and control ........................................................................................57
A1.3 Warning / Alarm display and acknowledgement ...................................................................58
A1.4 Menus ..................................................................................................................... 58
A1.4.1 Normal menu ............................................................................................................58
A1.4.2 Status menu .............................................................................................................59
A1.4.3 SETUP menu .............................................................................................................60
A1.4.4 COMMANDS menu .......................................................................................................61
A1.4.5 INV FAULT HIST (Display Inverter Fault History) menu ...........................................................61
A1.4.6 SOFTWARE VERSION Display menu ...................................................................................62
A1.4.7 FIT ACCESSORY menu ..................................................................................................62
A1.4.8 IP Configuration menu .................................................................................................62
A1.4.9 Display attributes menu ...............................................................................................63
Appendix A2 Troubleshooting .......................................................................... 65
A2.1 Warnings .................................................................................................................65
A2.1.1 LED warning indicators ................................................................................................. 65
A2.1.2 PDT warnings ............................................................................................................65
A2.2 Alarms ....................................................................................................................68
A2.2.1 LED alarm indicators ...................................................................................................68
A2.2.2 PDT alarms ...............................................................................................................68
A2.3 Inverter warnings and alarms .........................................................................................70
A2.4 Other problems .........................................................................................................75
A2.4.1 Pump controller communications ....................................................................................75
For return of equipment, complete the HS Forms at the end of this manual.
© Edwards Limited 2012. All rights reserved. Page iii Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
M561-00-880 Issue C
Illustrations
Figure Page
1 Applications ............................................................................................................... 2
2 The front panel controls ................................................................................................ 3
3 Front view of pumping system ......................................................................................... 3
4 The controls/connectors on the rear of the pump ................................................................. 4
5 Centre of gravity and levelling foot loads ........................................................................... 9
6 Reduce the effective system footprint ..............................................................................25
7 Connecting the pump inlet ............................................................................................27
8 The Harting Han
®
K 4/4 cable-mounted connector ...............................................................32
9 The Harting 100A axial screw module cable-mounted connector ...............................................33
10 Customer connection kit - combination low volts iXL750 ........................................................34
11 Electrical connector locking mechanism ............................................................................35
A1 Pump display terminal .................................................................................................57
Tables
Table Page
1 General technical data .................................................................................................. 5
2 General technical data .................................................................................................. 6
3 Performance data ........................................................................................................ 7
4 Loading data (refer to Figure 5) ....................................................................................... 8
5 Nitrogen purge data for iXH and iXL systems ........................................................................ 9
6 Gas module types and flows ..........................................................................................10
7 Electrical data iXH100 to iXH1820/H/T .............................................................................11
8 General electrical data ................................................................................................14
9 Electrical connections ..................................................................................................15
10 Wire assembly according to VDE 0295 ...............................................................................16
11 Water cooling system data ............................................................................................17
12 Cooling water supply temperature ...................................................................................18
13 Water consumption data ...............................................................................................19
14 Heater data ..............................................................................................................20
15 Tracer gas test parameters ...........................................................................................20
16 Tracer gas test system parameters ..................................................................................20
17 Worst case test results .................................................................................................21
18 Extraction rates required by system variant .......................................................................22
19 Alarm actions ............................................................................................................42
20 Pump protection sensors ..............................................................................................43
21 Dry pump and booster temperature settings .......................................................................50
22 Accessories ...............................................................................................................54
23 Seismic bracket kits ....................................................................................................55
24 Exhaust check valve kits ...............................................................................................55
A1 Pump start control ......................................................................................................57
A2 Pump stop and control .................................................................................................58
A3 Normal menu ............................................................................................................58
A4 Normal menu ............................................................................................................59
A5 Status menu .............................................................................................................59
A6 SETUP menu .............................................................................................................60
A7 COMMANDS menu .......................................................................................................61
A8 GAS VALVES menu ......................................................................................................61
A9 INV FAULT HIST (Display Inverter Fault History) menu ...........................................................61
A10 FIT ACCESSORY menu ..................................................................................................62
M561-00-880 Issue C
Page iv © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
A11 IP Configuration menu .................................................................................................62
A12 Display attributes menu ...............................................................................................63
A13 SELECT LINE (Normal display selection menu) .....................................................................63
A14 UNITS (Units to display) ................................................................................................63
A15 Warnings .................................................................................................................65
A16 Alarms ....................................................................................................................68
A17 Hexadecimal to digital conversion ...................................................................................70
A18 Inverter alarm codes ...................................................................................................71
A19 Inverter warnings codes ...............................................................................................72
A20 Inverter diagnostic display text ......................................................................................73
Associated publications
Publication title Publication number
Vacuum Pump and Vacuum System Safety P400-40-100 Semiconductor Pumping Application Guide P411-00-090
Trademark Credits
Han® is a registered trademark of Harting Electric GmbH EtherCon® is a registered trademark of Neutrik® AG Fomblin® is a registered trademark of Solvay Solexis SpA
© Edwards Limited 2012. All rights reserved. Page 1 Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
M561-00-880 Issue C
1Introduction
1.1 Scope and definitions
This manual provides installation, operation and maintenance instructions for the Edwards iXH, iXL and pXH dry pumping systems. You must use your pumping system as specified i n th is man ual othe rwis e the p rotection provid ed by the equipment may be impaired.
Read this manual before you install and operate your pump. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below.
CAUTION
Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment and/or process.
The units throughout this manual conform to the SI international system of units of measurement. The following warning labels are on the pump:
WARNING
Warnings are given where failure to observe the instruction could result in injury or death to people.
Warning - Refer to accompanying documentation.
Warning - Maximum angle between paired slings
Warning - Risk of electric shock. Warning - Heavy object.
Warning - Hot surfaces. Protective earth (ground).
Warning - Moving parts present.
Warning - use protective equipment. RF earth (ground).
M561-00-880 Issue C
Page 2 © Edwards Limited 2 012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
The following warnings only appear in this manual:
Material Safety Data Sheets for chemicals supplied by Edwards can be obtained by contacting Edwards, or on www.edwardsvacuum.com.
1.2 Applications
iXH, iXL and pXH pumping systems are intended for use on the Semiconductor, Solar and FPD processes shown in
Figure 1.
Figure 1 - Applications
The iXL systems are intended for use on clean duty applications. If you use the system on an application for which it is not suitable, you may invalidate your warranties. If in doubt,
contact Edwards who will advise you as to the suitability of the system for any particular application.
1.3 Description
The iXH dry pump range has been developed to mee t t he demanding requirements for process pumping solutions in the Semiconductor, Flat Panel and Solar industries. The range sets new standards for harsh proces s capability, reliability and reduced cost of ownership in low footprint packages.
The iXL pump range has been developed to meet cyclic loadlock duty applications used in the flat panel and sola r industries.
The pXH booster systems are not intended for use as stand-alone units. Each system must be backed using a suitable Edwards dry pump selected to match process and performance specifications.
1.4 Priority of control
The pumping system can be controlled by a number of modules: the front control panel (refer to Figure 2), a Pump Display Terminal (PDT), the Edwards System Controller or by the tool through the MicroTIM or one of the serial interfaces. Only one of these can have control of the system at any one time. That is, once one of these has control of the system, control requests from the others are denied.
In addition to the control modules listed above, the pXH proximity booster can control or be controlled by the Edwards backing pump. Con tact Edwards for more information on how to control a pXH using an iXH or other Edwards pumping system.
The PDT indicates who is in control. LEDs are also provided on the rear panel, front panel or PDT, which illuminate to indicate 'in control'.
Warning - Risk of explosion. Warning - pressurised.
iXH, iXL and pXH applications
ALD Metal Etch RTP
HDP-CVD Metrology SACVD
Implant Source Oxide etch Silicon Etch
Lithography PECVD Strip/Ashing
Load lock PVD Pre-Clean Transfer
LPCVD PVD Process
MOCVD RTA
© Edwards Limited 2012. All rights reserved. Page 3 Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
M561-00-880 Issue C
1.5 Active utility control
The Active Utility Control (Green Mode) function reduces utility consumption of the system while on stand-by. The Green Mode functionality is controlled by the on/off process signal from the Tool Interface Module. Contact Edwards for advice on application and activation.
Figure 2 - The front panel controls
Figure 3 - Front view of pumping system
Note: iXH 100, iXH 200H and iXH 610 variants have only two eyebolts provided for lifting.
Item
Control/connector identification
1EMS button 2 Running LED (green) 3 Start button 4Stop button 5 Local control button 6 Local control LED (green) 7 Power LED (green) 8 Warning LED (amber)
9Alarm LED (red) 10 Green Mode LED (green) 11 PDT (Pump Display Terminal)
connection
Item
Control/connector identification
1 Front panel control 2 Levelling feet (4 off) 3Castors (4 off) 4 Seismic bracket (4 off if
fitted) 5 Pumped gas inlet connection 6 RF Earth (ground) cable 7Extraction port 8 Lifting eyebolts (4 off)
M561-00-880 Issue C
Page 4 © Edwards Limited 2 012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
Figure 4 - The controls/connectors on the rear of the pump
Item Control/connector identification
1 Ethernet LAN LED (green) 2 Ethernet link LED (yellow) 3 Ethernet connection 4Power LED (green) 5System interface 6 Warning LED (yellow) 7 Running and Alarm LEDs (2 colours,
either green or red) 8 Accessory interface 9 MicroTIM in control LED (green)
10 EMS interface
11 Micro TIM connection (if fitted) 12 Electrical supply connection 13 Electrical connector locking
mechanism 14 Nitrogen purge connection 15 Cooling water supply connection 16 Protective earth (ground) stud 17 Exhaust gas outlet connection 18 Cooling water return connection 19 RF earth (ground) stud
Item Control/connector identification
© Edwards Limited 2012. All rights reserved. Page 5
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
2Technical data
2.1 General technical data
Table 1 - General technical data
Pump
Characteristics
Body dimensions
Length x Width x
Height
(excludes exhaust
enclosure)
*
Mass (excluding packaging)
Noise level
(at ultimate)
Typical
vibration
level at inlet
Initial force to push the
pump
Sustained
force to push
the pump
Pump inlet
flange
(bolted)
Exhaust gas
outlet
Extraction
port
diameter
Units mm kg dB(A) mm/s kg force kg force mm
iXH100 784 x 390 x 526 260 < 70 < 1.5 < 20 < 4 ISO63 NW40 105 iXH200H 901 x 390 x 526 287 < 70 < 1.5 < 20 < 4 ISO63 NW40 105 iXH450H 1000 x 517 x 650 455 < 70 < 1.5 < 20 < 10 ISO63 NW40 105 iXH500H 1000 x 517 x 650 490 < 70 < 1.5 < 20 < 10 ISO63 NW40 105
iXH610 784 x 390 x 780 355 < 70 < 1.5 < 20 < 4 ISO100 NW40 105
iXH1210/H 784 x 390 x 780 413 - 430 < 70 < 1.5 < 20 < 4 ISO100 NW40 105
iXH1220H/T 901 x 390 x 780 455 - 460 < 70 < 1.5 < 20 < 4 ISO100 NW40 105
iXH1820/H/T 901 x 390 x 780 471 - 487 < 70 < 1.5 < 20 < 4 ISO160 NW40 105
iXH3030/T 915 x 517 x 966 619 - 624 < 70 < 1.5 < 20 < 10 ISO160 NW40 105
iXH3045H 1000 x 517 x 966 776 70 < 1.5 < 20 < 10 ISO160 NW40 105
iXH3050H 1000 x 517 x 966 811 70 < 1.5 < 20 < 10 ISO160 NW40 105 iXH4545HT 1000 x 517 x 966 814 70 < 1.5 < 20 < 10 ISO200 NW40 105 iXH4550HT 1000 x 517 x 966 849 70 < 1.5 < 20 < 10 ISO200 NW40 105
iXH6045H/T 1080 x 517 x 966 860 - 865 74 < 1.5 < 20 < 10 ISO250 NW40 105 iXH6050H/T 1080 x 517 x 966 899 70 < 1.5 < 20 < 10 ISO250 NW40 105
pXH4500 1086 x 517 x 531 400 < 70 < 1.5 < 20 < 10 ISO200 ISO160 - pXH6000 1086 x 517 x 531 435 < 70 < 1.5 < 20 < 10 ISO250 ISO160 -
iXL250Q 1092 x 390 x 830 515 <64 <1.5 <20 <10 ISO160 NW40 105 iXL500Q 1186 x 517 x 966 860 < 70 < 1.5 < 20 < 10 ISO160 NW50 105 iXL500R 1186 x 517 x 966 874 < 70 < 1.5 < 20 < 10 ISO160 NW50 105
M561-00-880 Issue C
Page 6 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
iXL750Q 1622 x 517 x 1031 918 <70 <1.5 22 <10 ISO160 NW50 105 iXL750R 1622 x 517 x 1031 976 <70 <1.5 22 <10 ISO160 NW50 105
*
Contact Edwards for installation drawings
Measured in laboratory on level concrete surface
Table 2 - General technical data
Item Description Rating Units
Operating conditions
Intended use Indoor Ambient temperature range:
Operating 5 to 40 °C Storage -45 to 55 °C
Maximum relative humidity: 80% for temperatures up to 31 °C decreasing linearly to 50% relative
humidity at 40 °C Maximum operating altitude 2000 m Pollution degree 2 (IEC 61010)
Materials in contact with process gas
Pump, shaft and rotors Cast Iron, Steel Seals PTFE and fluoroelastomer Gas system Stainless steel, aluminium, brass, PTFE and fluoroelastomer
Degree of protection provided by enclosure
Enclosure protection when installed IP21D (IEC60529)
Table 1 - General technical data (continued)
Pump
Characteristics
Body dimensions
Length x Width x
Height
(excludes exhaust
enclosure)
*
Mass (excluding packaging)
Noise level
(at ultimate)
Typical
vibration
level at inlet
Initial force to push the
pump
Sustained
force to push
the pump
Pump inlet
flange
(bolted)
Exhaust gas
outlet
Extraction
port
diameter
Units mm kg dB(A) mm/s kg force kg force mm
© Edwards Limited 2012. All rights reserved. Page 7
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
2.2 Performance data
Table 3 - Performance data
Pump
Characteristics
Typical peak pumping speed
Ultimate
(shaft seal purge only)
Maximum continuous inlet pressure
Units m
3
/h mbar mbar
iXH100 100 < 3 x 10
-2
1000
iXH200H 215 < 3 x 10
-2
1000
iXH450H 500 < 3 x 10
-2
1000
*
*
Speed may be limited
iXH500H 500 < 3 x 10
-2
1000
*
iXH610 665 < 5 x 10
-3
1000
iXH1210/H 1025 - 1065 < 5 x 10
-3
1000
iXH1220H/T 1200 - 1250 < 5 x 10
-3
1000
iXH1820/H/T 1700 - 1900 < 5 x 10
-3
1000
iXH3030/T 2750 - 2900 < 5 x 10
-3
1000
*
iXH3045H 3225 < 5 x 10
-3
1000
*
iXH3050H 3200 < 5 x 10
-3
1000
*
iXH4545HT 4450 < 5 x 10
-3
1000
*
iXH4550HT 4220 < 5 x 10
-3
1000
*
iXH6045H/T 5000 - 5200 < 5 x 10
-3
1000
*
iXH6050H/T 5000 - 5200 < 5 x 10
-3
1000
*
pXH4500 N/A < 5 x 10
-3†
Ultimate achieved when pXH used in conjunction with an appropriate backing pump. Please contact Edwards to discuss your application. The pXH does not have a shaft seal purge.
1000
*
pXH6000 N/A < 5 x 10
-3†
1000
*
iXL250Q 1900 < 1 x 10
-3
1000
*
iXL500Q 2150 < 5 x 10
-3
1000
*
iXL500R 3100 < 5 x 10
-3
1000
*
iXL750Q 2300 < 1 x 10
-3
1000
*
iXL750R 3450 < 1 x 10
-3
1000
*
M561-00-880 Issue C
Page 8 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2.3 Loading data
Table 4 - Loading data (refer to Figure 5)
Pump
Dimension to centre of gravity Load at levelling foot position
ABCDE1234
Unitsmmmmmmmmmm kg kg kg kg
iXH100 697 295 165.5 311 280 80 59 51 70 iXH200H 814 403 165.5 311 261 77 76 66 68 iXH450H 924 443 220 427 323 122 112 106 115 iXH500H 924 422 220 427 324 137 115 109 129
iXH610 697 329 165.5 311 374 100 89 78 88
iXH1210/H 697 330 165.5 311 430 122 106 94 108
iXH1220H/T 814 457 165.5 311 430 107 136 120 94
iXH1820/H/T 814 400 165.5 311 433 134 127 112 118
iXH3030/T 829 395 230 436 545 183 147 131 164
iXH3045H 924 422 220.5 427 534 218 183 171 203
iXH3050H 924 409 220 427 524 233 185 174 219 iXH4545HT 924 422 220.5 427 539 228 192 180 214 iXH4550HT 924 411 220.5 427 529 243 195 183 228
iXH6045H/T 1004 398 220.5 427 549 269 177 166 252 iXH6050H/T 1004 388 220.5 427 539 285 179 168 267
pXH4500 990 460.5 225 438 325 110 96 90 104 pXH6000 990 422 224.5 438 326 128 95 90 122
iXL250Q 1038 421 130.5 261 463 154 103 103 154 iXL500Q 1110 497 219 427 468 212 172 164 202 iXL500R 1110 497 219 427 468 241 195 185 229 iXL750Q 1547 730.9 169 338 512.2 215 244 244 215 iXL750R 1547 722.1 169 338 534.6 229 259 259 229
© Edwards Limited 2012. All rights reserved. Page 9
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
Figure 5 - Centre of gravity and levelling foot loads
2.4 Nitrogen purge data
Note: pXH systems do not have a nitrogen purge facility.
Table 5 - Nitrogen purge data for iXH and iXL systems
Characteristics Rating Units
Nitrogen supply pressure range 2.5-6.9 bar gauge
36 - 100 psi gauge Nitrogen supply quality To ISO 8573 Nitrogen inlet connection 1/4 inch tube fitting
M561-00-880 Issue C
Page 10 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
Note: If you are not sure which gas module is fitted to your system, find the product code number on the label on the rear of the pump and then refer to the
product configurators at the start of this manual.
Note: H variant pumps fitted with Single Mode+ modules include the innovative Gas Buster
TM
inlet purge for improved powder handling.
For iXL systems:
iXL systems are designed for use on clean applications only.
Table 6 - Gas module types and flows
For iXH systems:
Gas module type
Description
Module
sizes
available
Total flow,
harsh
setting
Total fl ow,
medium
setting
Total flo w with inlet
purge
Total flow
with
exhaust
purge
Total flow with inlet
and exhaust
purge
Units
Loadlock Shaft seal only 4 4 - - - - -
Single mode
Gas ballast purge with harsh/medium manually selected
44 44 28 - - - slm
96 96 56 - - - slm 133 133 88 - - - slm 204 204 133 - - - slm
Single mode +
Gas ballast purge with harsh/medium manually selected + inlet purge
44 44 28 60 - - slm
96 96 56 122 - - slm 133 133 88 173 - - slm 204 204 133 264 - - slm
Multi mode
Gas ballast purge with electronically selected harsh/medium + inlet purge + exhaust purge
44 44 22 60 94 110 slm
96 96 34 122 146 172 slm 133 133 65 173 183 223 slm 204 204
*
*
Contact Edwards
264 254 314 slm
© Edwards Limited 2012. All rights reserved. Page 11
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
2.5 Electrical data
Table 7 - Electrical data iXH100 to iXH1820/H/T
Characteristics iXH100 iXH200H iXH450H iXH500H iXH610 iXH1210 iXH1210H iXH1220H/T iXH1820/H/T Units
Dry pump motor rating 4.5 7.5 11 11 4.5 4.5 7.5 7.5 7.5 kW Mechanical booster
motor rating
----1.94.54.54.54.5kW
Current rating (200 - 230 V systems)
21 38 44 44 28 28 38 38 38 A
Current rating (380 - 460 V systems)
11 20 23 23 14 14 20 20 20 A
Recommended branch circuit fuse UL (200 - 230 V systems)
25 45 55 55 35 35 45 45 45 A
Recommended branch circuit fuse IEC (200 - 230 V systems)
25 40 45 45 30 30 40 40 40 A
Recommended branch circuit fuse UL (380 - 460 V systems)
15 25 30 30 20 20 25 25 25 A
Recommended branch circuit fuse IEC (380 - 460 V systems)
15 20 25 25 15 15 20 20 20 A
Min cable size for 200 ­230 V systems (or corresponding AWG size)
6 (8)
*
10 (6) 10 (6) 10 (6) 6 (8)
*
6 (8)
*
10 (6) 10 (6) 10 (6) mm2 (AWG)
Min cable size for 380 ­460 V systems (or corresponding AWG size)
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)
*
*
The minimum geometric wire gauge for Han® K 4/4 is 6mm2 and minimum A WG size is 8 AWG
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)
*
6 (8)*mm2 (AWG)
Mains connector Han
®
K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 Han® K 4/4 -
M561-00-880 Issue C
Page 12 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
Table 7 - Electrical data iXH3030/T to pXH6000 (continued)
Characteristics iXH3030/T iXH3045H iXH3050H iXH4545HT iXH4550HT iXH6045H/T iXH6050H/T pXH4500 pXH6000 Units
Dry pump motor rating7.5111111111111 - -kW Mechanical booster
motor rating
7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 kW
Current rating (200 - 230 V systems)
44 63 63 63 63 63 63 28 28 A
Current rating (380 - 460 V systems)
23 32 32 32 32 32 32 14 14 A
Recommended branch circuit fuse UL (200 - 230 V systems)
55 80 80 80 80 80 80 35 35 A
Recommended branch circuit fuse IEC (200 - 230 V systems)
45 65 65 65 65 65 65 30 30 A
Recommended branch circuit fuse UL (380 - 460 V systems)
30 40 40 40 40 40 40 20 20 A
Recommended branch circuit fuse IEC (380 - 460 V systems)
25 35 35 35 35 35 35 15 15 A
Min cable size for 200 ­230 V systems (or corresponding AWG size)
10 (6) 25 (4) 25 (4) 25 (4) 25 (4) 25 (4) 25 (4) 6 (8)
*
*
The minimum geometric wire gauge for Han® K 4/4 is 6mm² and minimum AWG size is 8 AWG
6 (8)
*
mm2 (AWG)
Min cable size for 380 ­460 V systems (or corresponding AWG size)
6 (8)
*
10 (6)
The minimum geometric wire gauge for Han® 100A module is 10mm² and minimum AWG size is 6 AWG
10 (6)
10 (6)
10 (6)
10 (6)
10 (6)
6 (8)
*
6 (8)*mm2 (AWG)
Mains connector Han
®
K 4/4 Han® 100 A
module
Han® 100 A
module
Han® 100 A
module
Han® 100 A
module
Han® 100A
module
Han® 100A
module
Han® K 4/4 Han® K 4/4 -
© Edwards Limited 2012. All rights reserved. Page 13
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
The minimum geometric wire gauge for Han® 100A module is 10mm² and minimum AWG size is 6 AWG
Table 7 - Electrical data iXL250Q, iXL500Q/R and iXL750Q/R (continued)
Characteristics iXL250Q iXL500Q iXL500R iXL750Q iXL750R Units
Dry pump motor rating 7.5 11 11 22 22 kW Mechanical booster motor rating 4.5 7.5 7.5 7.5 705 kW Current rating (200 - 230 V systems) 38 75 63 140 135 A Current rating (380 - 460 V systems) 20 40 32 78 74 A Recommended branch circuit fuse UL (200 - 230 V
systems)
50 100 80 170 160 A
Recommended branch circuit fuse IEC (200 - 230 V systems)
35 80 65 140 135 A
Recommended branch circuit fuse UL (380 - 460 V systems)
25 50 40 95 90 A
Recommended branch circuit fuse IEC (380 - 460 V systems)
20 50 35 80 75 A
Min cable size for 200 - 230 V systems (or corresponding AWG size)
10 (8) 25 (4) 25 (4) 50 (1/0) 50 (1/0) mm
2
(AWG)
Min cable size for 380 - 460 V systems (or corresponding AWG size)
6 (8)
*
10 (6)
10 (6)
25 (4) 25 (4) mm2 (AWG)
Mains connector for 200 - 230 V systems Han
®
K 4/4 Han® 100 A
module
Han® 100 A
module
Han® 200 A
module
Han® 200 A
module
-
Mains connector for 380 - 460 V systems Han® K 4/4 Han® 100 A
module
Han® 100 A
module
Han® 100 A
module
Han® 100 A
module
-
M561-00-880 Issue C
Page 14 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
Contact Edwards for more information about configuration requirements for earth leakage reduction.
Table 8 - General electrical data
Description Rating Units
Supply voltage 3-phase either 200 - 230 or 380 - 460 (see rating plate) V a.c. Frequency 50/60 Hz Wiring configuration 3 wire plus earth (ground) Branch circuit protection requirement Current rating, refer to Table 7 Fuse Class gG (IEC 60269), UL class T, class J or class RK5, Bussmann type JJS or equivalent
I
2
t characteristic rated to 600 V Voltage tolerance range +/- 10% Installation category II (IEC 60664) Input supply voltage unbalance Should not exceed 2% when assessed over any one minute period Short circuit current rating (when installed with
class T or class J fuses)
200 kA
Second protective earth (ground) conductor Must be fitted with cross-sectional area at least equal to phase conductor size up to 16 mm
2
Maximum permitted overcurrent protection for systems with the Han
®
K 4/4 mains connector
*
*
If you use overcurrent protection above the ratings in Table 7 for systems with the Han® K 4/4, the minimum cable sizes no longer apply and you must ensure that the pump cable size is appropriately rated and in accordance with local legislation and electrical regulations. Ensure that cable size is compatible with the mains connector, refer to Table 9.
for 200 - 230 V systems 60 A for 380 - 460 V systems 35 A
Typical earth leakage
Typical earth leakage values were measured at steady-state conditions. Note that higher leakage currents may occur: i) under transient conditions such as power on or pump acceleration or ii) with abnormal supply configurations such as a missing or earthed phase or unbalanced supply voltages.
For 200 - 230 V systems
- for iXL750Q and iXL750R
- for all other systems
9 <5
mA mA
For 380 - 460 V systems
- for iXL750Q and iXL750R
- for all other systems
18 <10
mA mA
© Edwards Limited 2012. All rights reserved. Page 15
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
M561-00-880 Issue C
Table 9 - Electrical connections
Description Mating Connector description / external supply rating Internal supply rating Mains connection
Refer to installation s ection for wiring diagram
Refer to Tabl e 7 for the mains connector fitted to each variant.
Connector is either:
Harting Han® K 4/4-F finger safe
09 38 008 2703, 6-16 mm
2
fine stranded wire
(VDE 0295 class 5, refer to Table 10), 8.9mm max insulation diameter
Or
Harting Han® Axial Screw module 100A (2 off required), 09 14 002 2753 10-25 mm
2
or 09 14 002 2751, 16-35 mm2 fine stranded wire
(VDE 0295 class 5, refer to Table 10)
Or
Harting Han® Axial Screw module 200A (3 off required), part number of mating
half suitable for 25 - 40 mm
2
wire is 09 14 001 2763 or 09 14 001 2762 for
40 - 70 mm2 wire. Use fine stranded wire (VDE 0295 class 5, refer to Table 10)
PDT Interface (front) XLR type 5-way plug 24 V d.c. 0.2 A System Interface (rear) XLR type 5-way plug 24 V d.c. 0.75 A
*
Ethernet interface
Standard RJ45 type or Neutrik® EtherCon® RJ45 (IEEE802.3i
10 Base T Ethernet)
EMS interface
External emergency stop switch Pin 1 - supply, Pin 2 - return
Note: If there is no external connection a link plug must be fitted to operate the pump.
XLR type 6-way plug
24 V d.c. 100 mA
Internal emergency stop switch Pin 3 - common, Pin 4 - normally open 30 V a.c. 1 A, 60 V d.c. 0.55 A
Comms 24 V supply Pin 5 - supply, Pin 6 - 0 V supply common
24 V d.c. 0.75 A
*
Chassis