Important
Check both electrostatic
filters whenever the bin
is emptied and replace
at least every 3 months.
3
High efficiency H-level filters
Please note that if the filters are not checked regularly and
changed as required, the motor may overheat, which will
cause the thermal cut-out to operate.
NOTE: Vacuuming builder’s dust and some carpet
fresheners may cause the filters to require changing
more frequently. (Dyson does not recommend the use
of carpet fresheners).
Replacement filters are available from your local retailer
or direct from Dyson. Call or fax the Helpline for orders.
IMPORTANT: Use only genuine Dyson filters, which
have been tested and approved for this cleaner.
The Dyson DC02 has a built-in thermal cut-out to protect your vacuum
NOTE
cleaner in the event of a restriction to the airflow.
Your Dyson has a built-in thermal cut-out to protect it in the
IMPORTANT: Always unplug the vacuum cleaner from the wall
event of a restriction to the airflow and may suddenly stop
socket before inspecting it.
working temporarily if you do not change the filters at the
If the vacuum cleaner suddenly stops working (ie. the motor makes no sound
stated time, or if blockages are not cleared immediately.
when switched on) then please check your DC02 for blockages as detailed
If the vacuum cleaner suddenly stops working (ie. the motor makes no
in this operating manual. (Remember also to check the fuse in the plug).
sound when switched on) then please check your cleaner for blockages as
IMPORTANT
ALWAYS UNPLUG THE VACUUM CLEANER FROM THE WALL SOCKET BEFORE INSPECTING IT
Having established that there are no blockages and that the filters have
been replaced within the stated time, leave your vacuum cleaner
detailed in this operating manual. (Remember also to check the fuse in the
unplugged for 60 minutes and then try using it again.
plug). Having established that there are no blockages and that the filters
have been replaced within the stated time, leave your vacuum cleaner
unplugged for 60 minutes and then try using it again.
If the vacuum cleaner still does not work, please call Dyson
If the vacuum cleaner still does not work, please call Dyson
Customer Care (Tel: 01666 827272.)
Customer Care (Tel: 01666 827272).
Always replace both filters at least
every 3 months
Standard S-level filter
Always replace filter at least
every 3 months
Operating manual
Please read carefully before
assembling or using your
DCO2 vacuum cleaner.
Important safety instructions – please read before use
WHEN USING THE DYSON DCO2 VACUUM CLEANER PLEASE ADHERE TO THESE SIMPLE PRECAUTIONS.
BY DOING SO YOU WILL REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY.
Check that your supply corresponds to that shown on the rating plate. The appliance must
only be used as rated, it should be fitted with an ASTA approved fuse to BS1362.
European conformity information A sample of this product has been tested and found
to be in conformity with the following European Directives: 73/23/EEC Low voltage (safety)
Directive, 93/68/EEC CE Marketing Directive and 89/336/EEC EMC Directive.
For your convenience this appliance is supplied with a plug which is fitted with a 13amp
fuse of the appropriate rating.
Never put the plug into the socket outlet without the fuse cover fitted. Replacement fuse
covers are available from Dyson Customer Care. If the plug supplied is not suitable for
your socket outlet, it should be cut off and destroyed/safely disposed of. Warning: Under
no circumstances should the severed plug be inserted into a 13A socket, serious
danger of electric shock would result from the exposed wires.
The mains lead can then be shortened to the minimum required length, suitably prepared
and the correct style of plug to suit your household wiring system should be fitted. The
following wiring instructions should be followed. If in doubt, consult a qualified
electrician.
Unwanted products and the environment Should you find that your product needs
replacing one day, or is of no further use to you, think of protecting the environment. Dyson
will accept your old products and recycle them in an environmentally friendly way.
Helpline 01666 827272
Facsimile 01666 827298
Contact for all service assistance
IMPORTANTNOTE
The wires in the mains lead are coloured in accordance with the following codes.
Brown – Live
Blue – Neutral
As the colours of the wires in the mains lead may not correspond with the colours or
markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured Blue must be connected to the terminal which is marked with
the letter N or coloured Black.
The wire that is coloured Brown must be connected to the terminal which is marked with
the letter L or coloured Red.
Neither wire should be connected to the earth terminal of a three pin plug which is marked
with the letter E or or coloured Green or Green and Yellow.
Always ensure that the cable clamp is fitted and that it clamps the cable outer and NOT
the coloured wires.
If the supply cord of the appliance is damaged, disconnect the appliance from the socket
outlet immediately. The supply cord must be replaced and only by Dyson Appliances Ltd.
or their appointed agent as special purpose tools and service techniques are required.
DYSON CUSTOMER CARE
TETBURY HILL
MALMESBURY
WILTSHIRE
ENGLAND
SN16 ORP
1. Do not leave your Dyson cleaner with the plug connected to a mains outlet
– unplug when not in use. Turn the cleaner off with the switch button before
removing from the mains outlet.
2. Always remove the plug from a mains outlet before carrying out any
maintenance. Do not carry out any maintenance work on the cleaner other
than that outlined in this manual, especially where electrical components
are concerned.
3. Do not use without the clear bin assembly fitted correctly and both filters in
place.
4. Do not fit anything other than Dyson spare parts (available on the Helpline
on 01666 827272). Use of non-Dyson parts could invalidate your
guarantee.
5. Do not continue to use the cleaner if any part appears to be faulty, missing
or damaged. In these cases, contact the Dyson Helpline on 01666 827272.
6. Do not put any part of the body, clothes or any object near or into the
openings or moving parts of the machine. Do not use the machine with any
of the openings blocked with any object that may restrict the airflow.
7. Do not pull on the supply cord, run over it or pull it around sharp edges or
Helpline 01666 827272
Facsimile 01666 827298
Contact for all service assistance
near/over hot surfaces. If damaged, call the Dyson Helpline. Do not handle
the cleaner or plug with wet hands.
8. Do not use the cleaner if the cord or plug are damaged or if the cleaner has
been damaged, dropped or has come into contact with water or any other
liquid. In these cases, contact the Helpline.
9. Do not use the cleaner to pick up water or any other liquid. Electrical shocks
could occur if used outdoors or on wet surfaces.
10. Do not use the cleaner to pick up flammable or combustible substances or
hot ashes or burning objects of any kind. Do not use near such substances.
11. Do not work below the cleaner on the stairs.
12. Do not immerse the whole cleaner in water for cleaning. The clear bin alone
may be washed out after emptying. Ensure this is completely dry before
using the cleaner again.
13. Static charge can occur in many ways and, when vacuuming, certain carpets
may generate small static charges in the clear bin. These are entirely
harmless and are not associated with the mains supply. To minimise any
effect from this, do not put your hand or insert any object into the clear bin
unless you have first emptied and rinsed out the clear bin with water.
DYSON CUSTOMER CARE
TETBURY HILL
MALMESBURY
WILTSHIRE
ENGLAND
SN16 ORP
03-28-208 05-28-055 14/02/97 REV 1
1
2
Your DCO2 is fitted with two high area H-level electrostatic
cartridge filters. Alternatively a standard S-level filter may be
purchased.
1
Insert top filter ensuring that it fits snugly against the black
rubber seal on the machine.
2
Slide rear filter into the grooves and push it down fully.
Fitting instructions for the standard S-level filters are printed
on the filter itself.
2 H-level
OR
1 S-level
Clear bin full mark
Note: Do not fill above this line.
Changing filters
IMPORTANT
Use only genuine Dyson filters.
Sits securely
on the stairs
However, always
work above the
machine on stairs for
your own safety.
1
1. Hose & wand
click
2
Telescopic wand
3
Press yellow button and
slide wand down to
adjust length.
Automatic suction control trigger
Hold the yellow trigger down to reduce suction for
upholstery and curtains.
To maintain reduced suction, press the trigger down
hard until it clicks. To unlock and resume full suction,
press down the opposite end of the trigger.
Blockage procedure
Please note: Any ‘Blockage only’ repairs will incur a
charge of £35.00*. Please check your machine carefully.
Check filters, replace if older than 3 months, or if filters
are heavily coated with dust.
*Price correct at time
of printing.
1. Check entry swivel ∂ by
pressing yellow buttons &
pulling out hose.
Clear any debris.
1
1
1
To empty clear bin, pull back release catch under carr ying handle
and raise top of machine.
2 3
Lift clear bin out of machine.
Remove cyclone top (lid).
2. Clear bin removal
The plug is situated
underneath the tool
cover on the right
hand side.
On/off switch
Press left switch.
Cord rewind
Press right switch for cord rewind.
assembly
Assemble hose and wand by fitting
together at joints∂, ∑, and ∏. Push
yellow cuffs in until both buttons ‘click’
into place.
Press buttons and pull hose to release
Tool storage
Press yellow release catch to open the tool
storage cover and insert required tool into
end of wand or wand handle. Please
note that tools may feel warm when
machine has been running; this is
perfectly normal.
WARNING! For your own safety please
remember to unplug the machine when not in
use and before carrying out maintenance.
2
1 3
.
Wand
handle
Wand
Self adjusting
Floor tool
Fit floor tool by pushing
firmly into end of wand.
Height adjustment
Use selector to adjust to hard floor
or carpet. Forward for carpets and
back for smooth floors.
2
3. Check wand joint
by pulling wand
and wand handle
apart. Clear any blockage
with rod or wire.
2. Check wand handle swivel
by pressing yellow buttons and
pulling hose from wand. Clear
any debris.
3
4
4. Remove floor tool from
5. Check air intake hole and check ramp.
4
wand πand check for
blockage.
2
4 5
Wrap a plastic bag
tightly around the rim
of the clear bin.
3
6 7
Wipe shroud holes
free of all dust/debris.
click
Invert clear bin and wait at least
10 seconds before releasing.
OPTIONAL
Do not use strong
detergents and ensure
clear bin is fully dry before
replacing in machine.
Note: The yellow bin inner
should not be removed from
the bin when it is cleaned.
Replace clear bin and cyclone
8
top and close machine.
Ensure release catch
‘clicks’ into position before
using the vacuum cleaner or
lifting the machine by the
carrying handle.