Dynon Avionics AOA-Pitot Probe User Manual

AOA/Pitot Probe
P/N 100141-000
Heated AOA/Pitot Probe
P/N 100667-000
Installation Guide
This product is not TSO’d and cannot be installed into traditional
FAA Part 23 and similarly type-certificated aircraft
Document 100740-001, Revision C
October, 2014
Copyright © 2007-2014 by Dynon Avionics, Inc.
Permission to print this manual is granted to third parties.
Contact Information
Dynon Avionics, Inc. 19825 141st Place NE Woodinville, WA 98072 Phone: (425) 402-0433 - 8:00 AM – 5:00 PM (Pacific Time) Monday – Friday Dynon Avionics Technical Support available 7:00 AM–4:00 PM (Pacific Time) Monday – Friday Email: support@dynonavionics.com Fax: (425) 984-1751
Dynon Avionics offers online sales, extensive support, and frequently updated information on its products via its Internet sites:
www.dynonavionics.com –Dynon Avionics primary web site; including: http://docs.dynonavionics.com – Current and archival documentation. http://downloads.dynonavionics.com – Software downloads. http://support.dynonavionics.com – Support resources. http://store.dynonavionics.com – Dynon’s secure online store for purchasing all Dynon products 24 hours a day. http://wiki.dynonavionics.com – Dynon’s Documentation Wiki provides additional technical information on Dynon
products.
http://forum.dynonavionics.comDynon’s Internet forum where Dynon customers can interact with each other
and Dynon Avionics. A key feature of the forum is that it allows the exchange of diagrams, photos, and other types of files.
http://newsletter.dynonavionics.com – Dynon’s email newsletter. http://blog.dynonavionics.com – Dynon’s blog where you can find new and interesting Dynon-related content. http://register.dynonavionics.com – Register your Dynon Avionics product. http://license.dynonavionics.com – Redeem certificates for navigation mapping software, synthetic vision, and
other features for license codes that add new functionality to your SkyView system.
Copyright
2007-2014 Dynon Avionics, Inc. All rights reserved. No part of this manual may be reproduced, copied, transmitted, disseminated or stored in any storage medium, for any purpose without the express written permission of Dynon Avionics. Dynon Avionics hereby grants permission to download a single copy of this manual and of any revision to this manual onto a hard drive or other electronic storage medium to be viewed for personal use, provided that such electronic or printed copy of this manual or revision must contain the complete text of this copyright notice and provided further that any unauthorized commercial distribution of this manual or any revision hereto is strictly prohibited.
Information in this document is subject to change without notice. Dynon Avionics reserves the right to change or improve its products and to make changes in the content without obligation to notify any person or organization of such changes. Visit the Dynon Avionics website (www.dynonavionics.com) for current updates and supplemental information concerning the use and operation of this and other Dynon Avionics products.
Limited Warranty
Dynon Avionics warrants this product to be free from defects in materials and workmanship for three years from date of shipment. Dynon Avionics will, at its sole option, repair or replace any components that fail in normal use. Such repairs or replacement will be made at no charge to the customer for parts or labor performed by Dynon Avionics. The customer is, however, responsible for any transportation cost and any costs that are incurred while removing, reinstalling, or troubleshooting the product. This warranty does not cover failures due to abuse, misuse, accident, improper installation or unauthorized alteration or repairs.
THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE, AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY LIABILITY ARISING UNDER WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE AND IN COUNTRIES OTHER THAN THE USA.
iii AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C
IN NO EVENT SHALL DYNON AVIONICS BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER
Revision
Revision Date
Description
A
February 2007
Initial release
P/N 100740-000
B
February 2007
Changed references to the tube being sealable to note the likelihood of a leak.
Document number remains 100740-000
C
October 2014
Combined AOA/Pitot Probe Installation Manual and Heated AOA/Pitot Probe Installation Manual.
Extensively updated concurrent with release of redesigned Heated AOA/Pitot Probe.
Document number changed to 100740-001.
RESULTING FROM THE USE, MISUSE OR INABILITY TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. SOME STATES AND COUNTRIES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
Dynon Avionics retains the exclusive right to repair or replace the instrument or firmware or offer a full refund of the purchase price at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY.
These instruments are not intended for use in type certificated aircraft at this time. Dynon Avionics makes no claim as to the suitability of its products in connection with FAR 91.205.
Dynon Avionics’ products incorporate a variety of precise, sensitive electronics. SkyView products do not contain any field/user-serviceable parts. Units found to have been taken apart may not be eligible for repair under warranty. Additionally, once a Dynon Avionics unit is opened up, it is not considered airworthy and must be serviced at the factory.
Dynon Avionics Returns and Warranty web page can be found at http://support.dynonavionics.com.
Revision History
iv AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C
Table of Contents
Contact Information .....................................................................................................................................................iii
Copyright ......................................................................................................................................................................iii
Limited Warranty ..........................................................................................................................................................iii
Revision History ............................................................................................................................................................ iv
1. Introduction 1-1
AOA Calculation: Principles of Operation .................................................................................................................1-4
What is Angle of Attack, why is it important, and who uses it? .........................................................................1-4
Dynon Avionics' AOA/Pitot Probe .....................................................................................................................1-4
Airflow: Principles of Operation ........................................................................................................................1-5
Easy Installation and Calibration ........................................................................................................................1-5
Presentation ........................................................................................................................................................1-5
Heating: Principles of Operation ................................................................................................................................1-6
Failure Warning ..................................................................................................................................................1-6
Further Reading on Angle of Attack................................................................................................ ...................1-6
2. Technical Service Bulletin for Heated AOA/Pitot Probe 2-1
Unaffected Products ...........................................................................................................................................2-1
Affected Products ...............................................................................................................................................2-1
3. Heater Controller Mounting and Wiring 3-1
Tools and Materials Required .....................................................................................................................................3-1
Mounting the Controller .............................................................................................................................................3-2
Wiring the Controller ..................................................................................................................................................3-2
Wiring System Overview ...................................................................................................................................3-3
Probe to Controller Wiring .................................................................................................................................3-5
Controller Power and Pitot Heat Status Indicator Wiring ...................................................................................3-5
Pitot Heat Status .................................................................................................................................................3-5
4. Mounting and Plumbing 4-1
Tools and Materials Required .....................................................................................................................................4-1
Mounting ....................................................................................................................................................................4-1
Mounting Location .............................................................................................................................................4-1
Mounting Instructions .........................................................................................................................................4-2
Dimensions ................................................................ ................................ ................................................................ .4-3
Plumbing.....................................................................................................................................................................4-4
Moisture Drainage ..............................................................................................................................................4-4
Pressure Check ...................................................................................................................................................4-5
Heated AOA/Pitot Probe – Heater Check ...........................................................................................................4-5
Heated AOA/Pitot Probe – Pitot Heat Status Indicator Check (If Installed) ......................................................4-5
5. Angle of Attack Configuration and Calibration 5-1
6. Specifications 6-1
AOA/Pitot Probe P/N 100141-000 .............................................................................................................................6-1
Heated AOA/Pitot Probe P/N 100667-000 .................................................................................................................6-1
Heated AOA/Pitot Probe Controller ...........................................................................................................................6-1
AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C v
The symbol to the left indicates information which merits special attention.
The symbol to the left indicates a handy installation tip.
AOA/Pitot Probes and AOA products from Advanced Flight Systems, Inc. (AFS) The Dynon Avionics (DA) AOA/Pitot Probe is functionally equivalent to the AFS AF­Pilot AOA Pitot Probe. The DA Heated AOA/Pitot Probe is functionally equivalent to the AFS AF-Pitot Heated. Instructions for installation of AOA/Pitot Probe and Heated AOA/Pitot Probe with AFS products are in the AFS product manuals at
http://advanced-flight-systems.com.
1. INTRODUCTION
Thank you for your purchase of the AOA/Pitot Probe (Dynon Avionics P/N 100141-000) or the Heated AOA/Pitot Probe (Dynon Avionics P/N 100667-000). This guide provides some background on the concept of angle of attack and explains the steps to install both units in your aircraft.
This manual does not address installation of the Dynon Avionics AOA/Pitot Boom Probe, P/N 100532-000.
The two probes are compatible with the following Dynon Avionics products:
EFIS-D6 EFIS-D60 EFIS-D10A EFIS-D100 FlightDEK-D180 SkyView system
(Hereafter, the EFIS-x and FlightDEK-D180 are referred to as “EFIS unit.)
After physical installation is complete, the AOA/Pitot Probe must be calibrated for your airplane and your system. Instructions for AOA/Pitot Probe calibration are contained in the Installation manual for each compatible Dynon Avionics system. Installation manuals for these products can be found at: http://docs.dynonavionics.com.
The pitot function of the Dynon AOA pitot probe measures pitot pressure. This allows it to work with any standard airspeed indicator. However, the AOA functionality is designed specifically to work with Dynon Avionics and Advanced Flight Systems products. Do not expect a Dynon Avionics AOA/Pitot Probe or Heated AOA/Pitot Probe to work properly with any AOA system other than those of Dynon Avionics or Advanced Flight Systems.
AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C 1-1
Introduction
To display angle of attack on a Dynon Avionics EFIS unit or SkyView System, only a Dynon Avionics AOA/Pitot Probe or Heated AOA/Pitot Probe is supported. Using
another manufacturer’s or homemade AOA/Pitot probe may not produce accurate AOA information.
To ensure accuracy, it is very important that you install the probe correctly and perform the specified calibration steps. We recommend that you read and understand this entire manual and the corresponding calibration procedure in your EFIS unit’s Installation Manual or SkyView System Installation Guide before proceeding with installation.
The exterior of Dynon Avionics’ AOA/Pitot Probes and Heated AOA/Pitot Probes exterior are plated. Do not polish the probe – doing so could abrade the finish.
Block diagram of major steps for installation of AOA/Pitot Probe
1-2 AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C
Introduction
Block diagram of major steps for installation of Heated AOA/Pitot Probe
AOA/Pitot Probe and Heated AOA/Pitot Probe Installation Guide Rev. C 1-3
Loading...