MP03 XX 440 Series
1/10
Symbol
Parameter
Max. Units
390
A
Conditions
T
case
= 75oC
T
heatsink
= 75oC
T
heatsink
= 85oC
T
case
= 85oC
T
case
= 75oC
I
F(RMS)
RMS value
300
A
690
Mean forward current
Halfwave, resistive load
Code
Circuit
HB
G
GN
Repetitive
Peak
Voltages
V
RRM
Type
Number
Conditions
MP03/440 - 21
MP03/440 - 20
MP03/440 - 18
MP03/440 - 16
Lower voltage grades available. For full description of part
number see "Ordering Instructions" on page 3.
2100
2000
1800
1600
Tvj = 150oC
IRM = 30mA
V
RSM
= V
RRM
+ 100V
respectively
Module outline type code: MP03.
See Package Details for further information.
440 A
A340
A
I
F(AV)
FEATURES
■ Dual Device Module
■ Electrically Isolated Package
■ Pressure Contact Construction
■ International Standard Footprint
■ Alumina (non-toxic) Isolation Medium
APPLICATIONS
■ Rectifier Bridges
■ DC Power Supplies
■ Plating Rectifiers
■ Traction Systems
VOLTAGE RATINGS
CURRENT RATINGS - PER ARM
PACKAGE OUTLINE
CIRCUIT OPTIONS
KEY PARAMETERS
V
RRM
2100V
I
FSM
11250A
I
F(AV)
(per arm) 440A
V
isol
2500V
MP03 XX 440 Series
Dual Diode Modules
Replaces December 1998 version, DS5106-2.0 DS5106-3.0 January 2000
MP03 XX 440 Series
2/10
Symbol
Parameter
Conditions Max.
Units
AVR = 0
VR = 50% V
RRM
VR = 0
VR = 50% V
RRM
A2s
A2s
A
11250
405000
10ms half sine;
Tj = 150oC
10ms half sine;
Tj = 150oC
Surge (non-repetitive) on-state current
I
FSM
I2t for fusing
I2t
Symbol
Parameter
Conditions
o
C/W
Units
o
C/W
o
C/W
Thermal resistance - case to heatsink
per Diode
Thermal resistance - junction to case
per Diode
R
th(j-c)
Virtual junction temperatureT
vj
o
C
o
CT
sto
Storage temperature range
Mounting torque = 5Nm
with mounting compound
3 phase
halfwave
dc
Commoned terminals to base plate
AC RMS, 1min, 50Hz
Max.
R
th(c-hs)
Isolation voltage
V
isol
Symbol
Parameter
Conditions
1.29
mA
Forward voltage
30
V
FM
I
RM
Peak reverse current At V
RRM
, Tj = 150oC
At 1000A , T
case
= 25oC
V
TO
Threshold voltage
V0.94
mΩ0.32
At Tvj = 150oC
At Tvj = 150oC
r
T
On-state slope resistance
-40 to 150
0.12
0.13
0.14
o
C/W0.05
150
kV2.5
UnitsMax.
V
630000
9000
SURGE RATINGS - PER ARM
THERMAL & MECHANICAL RATINGS
CHARACTERISTICS
MP03 XX 440 Series
3/10
Adequate heatsinking is required to maintain the base
temperature at 75oC if full rated current is to be achieved.
Power dissipation may be calculated by use of VTOand r
T
information in accordance with standard formulae. We can
provide assistance with calculations or choice of heatsink
if required.
The heatsink surface must be smooth and flat; a surface
finish of N6 (32µin) and a flatness within 0.05mm (0.002")
are recommended.
Immediately prior to mounting, the heatsink surface should
be lightly scrubbed with fine emery, Scotch Brite or a mild
chemical etchant and then cleaned with a solvent to
remove oxide build up and foreign material. care should be
taken to ensure no foreign particles remain.
An even coating of thermal compound (eg. Unial) should be
applied to both the heatsink and module mounting surfaces.
This should ideally be 0.05mm (0.002") per surface to
ensure optimum thermal performance.
After application of thermal compound, place the module
squarely over the mounting holes, (or 'T' slots) in the
heatsink. Using a torque wrench, slowly tighten the
recommended fixing bolts at each end, rotating each in turn
no more than 1/4 of a revolution at a time. Continue until the
required torque of 5Nm (44lb.ins) is reached at both ends.
It is not acceptable to fully tighten one fixing bolt before
starting to tighten the others. Such action may DAMAGE the
module.
ORDERING INSTRUCTIONS
Part number is made up as follows:
MP03 HB 440 - 18
MP = Pressure contact module
03 = Outline type
HB = Circuit configuration code (see "circuit options" - front page)
440 = Nominal average current rating at T
case
= 75oC
18 = V
RRM
/100
Examples:
MP03HB440 - 21
MP03G440 - 16
MP03GN440 - 18
Note: Prefered type is HB configuration. G and GN types are available for specific applications, only
when requested.