Thermostat Sensor
Lead Panel Rework
5/16" Wrench
|
|
BACK |
1. |
Disconnect power to the unit. |
3. Remove the side louvered panel, using a 5/16" |
wrench; remove the two screws at the back (customer |
||
2. |
Remove front (operator side) louvered panel. |
side) of the unit. |
Mark |
ange |
Thermostat |
Probe Lead |
4. Inspect the thermostat probe lead for damage. |
|
5. Mark the bottom inside flange of the side panel at 2" |
If damaged replace with part number 226837. |
|
and 4" from the front (operator side). |
|
|
|
|
|
|
6.Using a pliers, bend the area between the marks up approximately 45°.
7.Replace the side panel.
8.Replace front panel and reconnect power.
229102A