The Critical Role of Yacht Air ConditioningThe Three Biggest Challenges When Choosing the Right Company
In any yacht design, especially in the design of
a super yacht, air conditioning plays a critical
role. No matter how elegant the surroundings,
they won’t feel luxurious if the temperature
of the living area is less than comfortable. It is
wise, therefore, to engineer the air conditioning
system for the unique characteristics of
each yacht, and address climate control
with as much attention and expertise as
you give to the design of the yacht itself.
Capacity From 16,000 to 2.52 Million BTUs
For Yacht Lengths of 20m to over 90m
Dometic’s chillers range in capacity
from 16,000 to 2.52 million BTUs. To
meet many unique needs, systems
are available in a variety of styles, such
as compact units, modular staged
units, and mammoth tube-andshell systems for very large yachts.
Custom chillers can also be designed
to meet special needs.
Key Benefits
■
Largest equipment selection.
■
Global service network.
■
Installation supervision.
■
Proper system sizing.
■
Equipment reliability.
Mid-Range Capacity
Single Stage
Cruisair’s reverse-cycle
TWC Compact is
available in 24K-36K
BTU/hr models.
The Marine Air MCW Low Prole delivers
36K to 72k BTU/hr in a
height-saving package.
Mid-Range Capacity
Multi Stage
Cruisair’s new
environmentally-safe
MTD provides up to
120K BTU/hr.
The Marine Air
MCW can deliver
up to 180K BTU/hr
in a single unit.
Occasionally, naval architects, builders, and
owners do not have the experience and
specialized knowledge it takes to assess realworld air conditioning requirements. Look to
Dometic for the resources and
expertise you need. Our
senior engineers can
design your yacht’s air
conditioning system
or review your design
and specifications to
make sure everything
is correct.
Large-Capacity
Tube-and-Shell
Designed for pleasure yachts
and commercial vessels, the
25-ton MTS tube-and-shell
chiller provides high-capacity
cooling in modular form.
Custom-engineered
tube-and-shell units are
congured to meet the
customer’s capacity and
feature requirements,
while adhering to their
unique space limitations.
Do you know the three biggest challenges to
consider when choosing the right air conditioning
company for your yacht?
Complete engineering support: Proper
1
system sizing, specifications, installation
supervision, and system training.
Since 1959, Dometic Cruisair and Marine Air have
been providing the most proven and innovative
marine air conditioning systems in the world.
Dometic’s expert and experienced engineering
team will review your drawings and specifications to
ensure all measurements and load calculations are
correct. Or, you can have them layout your system,
Broad selection: A wide variety of chilled
2
water systems, air handlers, and control
systems to suit the needs of different yachts
and different usage profiles.
Equipment reliability: Quality, dependable
3
equipment backed up by a certified worldwide
service network.
size all the appropriate capacities, and provide
you with the world’s broadest range of equipment
and accessories. We also support installation and
startup supervision, reliable documentation, and
system training.
Dometic engineers and builds the most
dependable air conditioning systems in the
Custom Engineering Solutions
Dometic Eliminates Your Sizing Guess Work
Dometic’s engineering team will work with you
to develop a chiller system that meets your BTU
capacity and fits the spatial limitations of your yacht’s
Load Calculation Table
CabinLengthWidth
Pilot House14'20'28015042,000
Sky Lounge40'20'80012096,000
Chart Room10'10'100909,000
Capt. Cabin14'10'1409012,600
Capt. Head8'8'64905,760
Foyer/Head12'7'84907,560
Area
(sq. ft.)
Load
Factor
Capacity
(BTU/hr)
architecture. Our engineers are with you from start
to finish with system design, installation supervision,
system start-up, documentation, and training.
FOYER/HEAD:
SINGLE ATV AIR HANDLER
world, and keeps them running with a global
network of trained sales and service personnel,
available 24/7, 365 days a year.
World’s Broadest Selection and Variety of Chilled Water Systems and Accessories for SuperYachts
E
N
V
I
R
O
N
M
E
N
T
A
L
L
Y
R
E
S
P
O
N
S
I
B
L
E
E
N
V
I
R
O
N
M
E
N
T
A
L
L
Y
R
E
S
P
O
N
S
I
B
L
E
All Units
Available
With Green
Gas
Single Stage ChillersTube-and-Shell ChillersCustom Multi Stage Chillers
TWC36C
The TWC chiller cools and heats,
and is currently available in 24K,
30K, and 36K BTU/hr sizes.
CapacityVoltage/Cycle/Phase
36,000 BTU/hrAll standard voltages.
MCWLP
ss
The modular MCW Low Profile
is available in 36K to 72K BTU/hr
models in a height-saving design.
CapacityVoltage/Cycle/Phase
72,000 BTU/hrAll standard voltages.
MCW
s
The modular MCW is available in
capacities from 24K BTU/hr to 180K
BTU/hr.
CapacityVoltage/Cycle/Phase
180,000 BTU/hr All standard voltages.
TWC3X2.5HC–CS–TWLC
s
Three 2.5-ton TWC units on a
standard base.
CapacityVoltage/Cycle/Phase
90,000 BTU/hr230/60/1
FMTC55VDC-407
Two 5-ton MTC units on a vertical
frame.
CapacityVoltage/Cycle/Phase
120,000 BTU/hr230/50/3
MCW192
s
Four 4-ton MCW units mounted on a
standard base.
CapacityVoltage/Cycle/Phase
192,000 BTU/hr230/60/3
FMTC4X5.5HECK
Four 5.5-ton units on a standard
base with bolt-on frame.
CapacityVoltage/Cycle/Phase
264,000 BTU/hr230/60/3
All Chillers Available
In 60Hz or 50Hz
FMTC5X5HD-407
s
Five 5-ton MTC units painted
Japanese Coast Guard green.
CapacityVoltage/Cycle/Phase
s
s
300,000 BTU/hr230/60/3
FMTCLP6X5VDC
Six 5-ton MTC low profile modules
on a custom frame.
CapacityVoltage/Cycle/Phase
360,000 BTU/hr230/60/3
MCW480(009)SCL
s
Four 10-ton MCW cool-only units on
a custom vertical frame.
CapacityVoltage/Cycle/Phase
480,000 BTU/hr208/60/3
MCW540(002)SEHN
Three 15-ton MCW cool-only units
on a custom frame.
CapacityVoltage/Cycle/Phase
540,000 BTU/hr460/60/3
s
s
s
MTS480
Two 20-ton MTS
units on standard
base and frame.
CapacityVoltage/Cycle/Phase
480,000 BTU/hr380/50/3
STS540(001)SEH
s
Three 15-ton units with tube-and-shell
condensers on a custom base and frame.
CapacityVoltage/Cycle/Phase
540,000 BTU/hr230/60/3
s
Dometic’s Pump Packages conveniently reduce the
installation time of chilled-water systems by combining
several necessary components in one package.
■
Includes pump, expansion tank, dual-scale (psi/kPa)
45
pressure gauge, and fill assembly.
■
Bladder-style expansion tank relieves water pressure
to prevent leaks.
■
Dual-scale pressure gauge is convenient for US and
international customers.
AT-MU air handlers are designed for use in fresh air
make-up systems where outside air is drawn in by the
air handler, cooled, dehumidified, and reheated to room
temperature, then ducted to various areas.
■
Compact design with vibration isolation mounts.
■
Electric heat with 2-stage electric heat overload.
■
Integrated 3-way bypass valve.
Our Variable Frequency Drive eliminates the large
starting in-rush of current of the compressor by ramping
up voltage and frequency in a controlled time period.
■
208/230V 3-phase output with 1-phase or 3-phase
input.
■
Full 60Hz capacity even at 50Hz input (230V only).
■
400/480V 3-phase models available.
Accessories for improved efficiency of chilled water AC
systems.
■
The Spirovent™ bleeds the entire system of excess air.
■
The Back-flow Preventer protects fresh water from
contamination.
■
The Pressure Regulator protects the loop water
from high-pressure damage.
Page 4
World’s Broadest Selection of Controls and Air Handlers
The Cruisair Chiller Gateway allows
monitoring and control of a Cruisair multi-staged
chiller system from a remote location via a
Modbus TCP/IP connection.
■
Puts chiller control on yacht’s
integrated network.
■
High-speed digital interface.
■
Monitors the optional Variable
Frequency Drive.
■
Configuration capable of
monitoring up to six chillers.
■
Monitors temperatures, current,
pressures, input/output status,
system faults/alarms, mode of
operation, and system logs.
Internet
Chiller Gateway Network
Interface with and without
graphical touch screen.
Ship-wide
touchscreen
control system.
Ship-Wide Networkable Controls
Total Control at the Touch of a Button
For complete climate control on board
your yacht, Dometic Cruisair and Marine Air
offer the Q-Logic and Elite™ digital control
SKY LOUNGE
systems. Both are available with optional
CAN-bus network adapters, and a wide
variety of attractive, stylish bezels.
ABLATL
ATVABLATL
FOYER
CAPTAIN’S
CABIN
Cruisair Q-Logic Controls:
■
Dual microprocessor-based.
■
Supports both the Qht and Q3
displays.
■
Optional CAN-bus network adapter provides
ship-wide monitoring and climate control.
ATV
CHART ROOM
AT-DC
AT-DC
PILOT
HOUSE
AT-DC
Marine Air Elite™ Control:
■
Operates with Passport I/O circuit
board.
■
Integrated faceplate air sensor.
■
Optional CAN-bus network adapter provides
ship-wide monitoring and climate control.
Chiller fresh water
loop system
CAN-bus network
Digital climate
control
Gateway network
interface
Dometic’s Environmental Policy
We are committed to minimizing the environmental
impact of our products through regular assessment
of energy and material demands, emissions, waste
generation, and recyclable resources.
For many years we have proudly displayed our
“Environmentally Responsible” logo, which indicates our
commitment to protecting the environment.
Since 1994, with the phase out of R-12 and now R-22,
Dometic leads the industry in the development of globally
compliant marine air conditioning systems.
Chilled Water Air Handlers
Featuring WhisperCool Technology
WhisperCool Technology eliminates the annoying
“motor hum” from traditional air conditioning blowers that
occurs at very low speeds. Incoming alternating current is
converted to drive a high-efficiency, brushless DC fan motor.
The result is a much quieter fan operating across a broad
range of variable speeds, permitting the user to select the
connections, offset coil from drain-pan edge, and a
redesigned bypass valve.
■
Improved coil design for better dehumidification and
cooling.
■
More accessible maintenance points.
ATL and ABL Air Handlers:
■
Height-saving design is ideal for over-head
applications.
■
Suspend from above or support from beneath.
■
Vibration isolation included.
■
Heater elements accessible from underneath.
■
Bypass valve has removable power head for simple
servicing.
■
Valve body is soldered to unit to prevent leaks.
ATV Air Handler:
■
Fits into walls.
■
Unique vertical design.
■
Minimal depth.
■
DC blower provides strong, quiet performance.
■
Blower rotates to vertical or horizontal positions for
ducted applications.
■
Electric heater included.
67
Page 5
Certified Worldwide Sales and Service Network
Largest Global
Service Network
Dometic has the largest global
network of trained sales and
service teams to support you.
No matter where you build or
travel, Dometic has the certified
personnel to support you.
DOMETIC CORPOR ATION, ENVIRONMENTAL DIVISION
2000 N. A ndrews Ave. Ext. l Pompano Beach, FL 33069 USA l 954-973-2477 l Fax 954-979-4414
P.O. Box 15299 l Richmond, VA 23227 USA l 804-746-1313 l Fax 804-746-7248
www.dometic.com
United States & Canada Ser vice O nly:
8:00 AM to 5:00 PM Eastern Time l Marine Air AC Products: 954-973-2477
Cruisair AC Products: 804-746-1313
24/7 AC SERVICE HOTLINE : 5:00PM to 8: 00 AM: 888-440-4494
International Sales & Servic e:
Europe & the Middle East: Call +44 (0 )870-330-6101
For all other areas visit our website to find your nearest distributor.
L–2624 Rev. 20081024 ISO 9001:2000
Environmentally
Responsible
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.