Dometic RM460, RM1300, RM760, RM360, RM660 User Manual

SERVI
INSTALLATION
United States
SALES OFFICES DOMETIC SALES CORP.
2320 Industrial Pkwy.
Elkhart, IN 46515 Phone 219-295-5226
DOMETIC SALES CORP. 14441 Bonelli
City of Industry, CA 91746
Phone 616-966-9431
DOMETIC SALES CORP. 1625-A Rock Mountain Blvd.
Stone Mountain, GA 30083 Phone
DOMETIC SALES CORP. 7695 S.W. Hunziker Rd.
Portland, OR 97223 Phone 503-620-9510
DOMETIC SALES CORP. 2920 Avenue
Arlington, TX 76011 Phone 617-277-7211
DOMETIC SALES CORP. East Oak Ridge Dr.
Rt.
9, Box 17 A Hagerstown. MD 21740 Phone
St.
404-493-6214
“E”
301-797-0826
East
Canada
AND
OPERATING INSTRUCTIONS
REFRIGERATOR FOR LP-GAS
AND
ELECTRIC OPERATION.
REFRIGERATOR
RM360 RM460 RM660 RM760 RM1300
Euroclean Canada Inc.
Dometic Recreation Division 666 Langs Drive Cambridge, Ontario N3H
2N7 Canada
(519)
653-8880
FOR YOUR SAFETY If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
Installation Instructions for use Gas equipment Electric equipment Maintenance Fault tracing Door panel
Page
9-10
10
10-11
11
11 12
DSC# 303
REFRIGERATORS WlTH PIEZ0
IGNITER
Fig. la
E
2
DCB A
Fig. 4a
REFRIGERATORS AUTOMATIC IGNITION
WlTH
E
CB A
Fig. 4b.
3
Fig. 2
Clear blue
colour
Fig. 5
of flame
Fig. 3
-
Gas equipment parts
1.
Burner tube
2.
Burner housing
3.
Burner jet
4. Feeler point (thermocouple)
5. Flame failure safety device
6.
Bypass screw
7.
Gas/Electric thermostat
6. Pressure test gage connection
9. Capillary tube for thermostat
10.
Shut-off valve
11. Piezo igniter (lighter)
12.
Firing tip
24.Hexagon nut
Electric equipment parts
13.
Flexible cord
14.
Change-over switch
15.5Terminal block, 12 V
16.
Reigniter
17.
Relay
22.
Cover
DC
23. Terminal block, 12 V DC, on certain models only 4
Fig. 6
INSTALLATION
GENERAL INSTRUCTIONS
The refrigerators outlined hereon have been design certified under ANS i! 21.19 Refrigerators by the American Gas Asso-
ciation for installation in a mobile home or recreational vehicle
and are approved by the Canadian Gas Association.
The certifications are, however, contingent on the installation
being made in accordance with the following instructions as
applicable.
The installation must in the USA conform with:
1.
National Fuel Gas Code 2223.1-l 974
2. Mobile Homes Al 19.1-l 975
3. Recreational Vehicles Al 19 2-l 975 The unit must be electrically grounded in accordance with the
National Electric Code ANSI, Cl- 1978 when installed if an external alternating current electrical source is utilized.
4. Any applicable local code
In Canada
1. Standard CGA 10.1 housing and recreational vehicles
2. Sandard CSA 2240.61 electrical requirements for mobile housing
3. Standard CSA ments for recreational vehicles.
Ventilation
The installation shall be made in such a manner as to separa­te the combustion system from the living space of the mobile home or recreational vehicle. Openings for air supply or for venting of combustion products shall have a minimum dimen­sion of not less than
Proper installation requires one lower fresh air intake and one upper exhaust vent. The ventilation kits shown in this instruc­tion booklet have been certified for use with the refrigerator models listen in the tables. Certified vent system kits, see separate list. The ventilation kits must be installed and used without midification. An opening towards the outside at floor level in the refrigerator compartment must be provided for ventilation of heavier-than-air fuel gases. The lower vent of the recommended kits is provided with proper size openings. The flow of combustion and ventilating air must not be obstructed. For ready serviceability of the burner and control manifold parts of the refrigerator the lower side vent is fitted with a iiftout planel
which provides an adequate access opening.
/CSA
2240.4, gas equipped mobile
Z240.6.2/C22.2
1/4
inch.
No 148 electrical require-
ged
directly
into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this p!ug The cord should be routed to burner cover. flue cover or other hot components
Refrigerator models
avoid
coming In contact with the
requiring
12 V DC
supply
On units provided with interior light or automatic reigniter or both there is one additional terminal block marked “Tri-Power” units with interior light or automatic reigniter or
both there are two additional blocks. The refrigerator must be connected to the battery circuit with two wires of adequate capacity to avoid voltage drop. The wire gage should be chosen with consideration to the wire length in accordance with table below. The 12 V circuit must be fused. Maximum circuit fuse size: 15 Amps. for the models RM 360 and RM 460.20 Amps. for RM 660.30 Amps. for RM 760 and RM 1300. Do not use the body or chassis of the vehicle as a substitute for either of the two conductors. No other electrical equipment or lighting should be connected to the refrigerator refrigerator will draw from 10 to 23 Amps at 12 Volt depending on model. The interior light and the reigniter must be connected to a separate battery circuit and will draw about 1 Amp.
Maximum two conductor wire length in feet
RM360 RM460 RM660 RM760 RM1300
AWG
125W 135w 175w 250W
14 10 9 7 5 4 17 12 17 15 12 8 7 35 10 27 25 19 13 12 55
8 43 40 31 22 19 85 6 69 64 49 34 31 135 4 110 102 79 55 50 220
light only
275W
"
12 V”. On
circuit
The
Interior
10W
CAUTION Do
not operate the refrigerator on 12 Volt when the vehicle IS parked. You will run out of battery in a rather short time. If possible the installation of a 12 Volt operated refngerator should be completed with a relay mounted either in the recreational vehicle (see Fig below automatically stopped
cut out the
refrigerator
when the car motor is
)
This
in
the car or
relay
will
GAS CONNECTION
Hook-up to the gas supply line is accomplished at the manual gas valve, which is furnished with a male flare connection. All completed connections should be
checked for leaks with soapy water. The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11 inches water gage.
In case detailed instructions on the installation and connection to the gas supply are required, contact your dealer or distribu­tor.
3/8”
SAE (UNF
5/8”-
18)
ELECTRICAL CONNECTION
120 Volts A C The refrigerator is equipped with a three prong (grounded)
plug for protection against shock hazards and should be plug-
Fig. 7
SPECIAL HINTS
The refrigerator must be installed in a substantial enclosure and must be level. A spirit level is supplied with each refrigera-
tor and by placing it in the freezer compartment one can level the refrigerator both ways front to back and side to side. When installing the refrigerator in the enclosure care should be taken to ensure a complete sealing between the front frame of the refrigerator and the top, sides and bottom of the enclosure. For this purpose a length of sealing strip is applied to the rear surfaces of the front frame. A sealing strip should also be applied to the foremost floor of the enclosure as shown in fig 8. The sealing should provide a complete isolation of the appli­ance combustion system from the vehicle interior. Be careful not to damage the sealing strip applied to the floor of the enclosure when the refrigerator is put in place. In the front frame and in the base at the rear of the refrigerator there are holes for screws for fixing the refrigerator in the enclosure. (Fig. 13). Any space between counter or storage area and the top of the refrigerator must be blocked. The heat produced at the rear of the refrigerator will otherwise become trapped in this space making the top of the refrigerator hot and reducing the effi­ciency of the refrigerator.
Do not install so that an adjacent heat producing appliance will
affect the construction or performance of the refrigerator.
TO CHANGE THE DOOR OPENING FROM
LEFT TO RIGHT OR VICE VERSA
Open the door and unscrew the two screws holding the top front cover. The screws are accessible form beneath. Remove
the top hinge pin and lift out the door.
The lower pin for the refrigerator door should be shifted to the
opposite side. The door can then be remounted. Before the top front cover is
refitted check that the door closes easily and that the gasket
seals well on all sides.
Fig. 8
TO REMOVE AND REPLACE THE REFRIGERATOR
Before working on the refrigerator make sure that 120 V A.C.
and optional 12 V D.C. leads are disconnected.
Unscrew the hexagon nut 24 and move the valve on the gas
line out of the bracket. Check that the valve slips out of the clip
connection with the switch shaft.
Loosen the screws fixing the refrigerator to the enclosure and remove the refrigerator. When replacing the refrigerator make sure that the sealing
strips are properly positioned. After reassembly the gas con-
nection should be checked for leaks.
Fig. 13
CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower side vent or as optional one upper vent and one lower side vent. The two alternatives are provided for by using the different kits listed in the Appendix. For further information contact your dealer or distributor.
METHODS OF INSTALLATION
The methods of installation are shown in figures 9 and 10. It is essential that all maximum or minimum dimensions are strictly maintained as the performance of the refrigerator is dependent on an adequate flow of air over the rear of the refrigerator.
VENTILATION HEIGHTS
Refrigerator
Minimum ventilation heights in inches
41
RM360 RM460 RM660 RM760
RM1300
Fig.
Condenser
9
Duct cross section area
5"x18"
Condenser
Fig. 10
7
CLEARANCES
Minimum clearances in inches to combustible G: Top 0
K: Side 0 L: Bottom 0
M: Rear 1
materials
are
Clearance M between the the wall behind the refrigerator Clearance N on top of the condenser is related to the minimum’ventilation height See Fig 11 and examples below
rearmost
part of the
refngerator
and
Fig. 11
Refrigerator model
RM360 30 3/8 21 11/166 22 RM460 32 15/16623 24 11/16632 1/8 21 9/16 22 3/4 32 5/16 21 13/16 23 3/4 1 1/4
RM660 40 13/16623 24 RM760 52 23 24 11/166 51 3/16 21 9/16 22 3/4 51 3/8 21 13/16 23 3/4 1/8
RM1300 57 15/166 24 15/166 24 11/16 57 1/8 23 7/16 22 3/4 57 1/2 23 13/16 23 3/4 1/8
Overall
dimensions
Height A
Width B
Depth C
1/16 29 9/16 20 1/4 20 3/16 29 3/4 20 1/22 21 3/16 1 1/4
11/166 40 21 9/16 22 3/4 40 3/16 21 13/16 23 3/4 1 1/4
Installation dimensions
Height h
Width
W
Recess dimensions
Depth Height Width d
H
W
Depth D
Distance between top of condenser to top of refrigerator
e
EXAMPLES
The clearance N for the RM360 model IS derived at in the
following way
Installation with upper and lower side vents N=Minimum ventilation height 37 minus installation height 29
9/1
6 plus distance between condenser top and
rator
top 1 1/4
N=37-29 9/16+1 1/4=8 11/16
with
Installation
N=Minimum 29
9/1
6 plus distance between condenser top and refrigerat­or top 1 1/4 plus distance between roof surface and roof vent cap 5 1/4
roof vent and lower side vent
ventilation height 31 minus installation height
N=31-29 9/16+1 1/4+5 1/4=7 15/16
refrige-
Fig. 12
8
INSTRUCTIONS FOR USE
HOW TO START THE REFRIGERATOR Leveling
In the boiler ammonia vapor is distilled from an ammonia-wa­ter mixture and carried to the finned condenser, where it liquifies. The liquid flows to the evaporator, where it creates cold by evaporating into a circulating flow of hydrogen gas. If the evaporator coil is not level the liquid readily accumulates,
forming pockets which can impair the gas circulation or even
block it, in which case, of course, the cooling will stop.
When the recreational vehicle is stationary it must be leveled to be comfortable to live in. If the refrigerator is properly installed. e e the freezer shelf parallel to the floor, the refrige­rator will then also perform well. A bubble level should be placed on the freezer shelf. When the vehicle is on tow, the continuous rolling and pitching movement will not affect the ment passes either side of level, but when the trailer is tempo­rarily parked this sensitivity of the refrigerator should be re­membered. So, once more, before you start the refrigera-
tor make sure it is level.
refrigerator as
long as the move-
Gas Operation (Fig. 4a) with piezo igniter
To start the refrigerator turn the knob A to position “GAS” Turn the thenostat knob B to setting 4
Push the button C to stop and push the button
piezo igniter. The pushing has to be repeated until the gas is lit at the burner. This can be observed through the reflector E After the gas is lit keep the button C pushed for 10 se-
conds. Release the button and check through the reflector that the burner flame stays burning. If not repeat the ligh­ting procedure. To shut off the refrigerator turn the knob A to off position.
D
of the
Flame Blow Out
If trouble is encountered with the flame blowing out under specially windy conditions, try to avoid the wind blowing aga­inst the wall where vent outlets are located. If the trouble persists, set the thermostat to MAX. This later measure can off course only be temporary such as when the vehicle is on tow, for after a day or so at this setting the foodstuffs in the cabinet will freeze.
Electric Operation (Fig. 4)
1. Check that the attachment plug is correctly connected to the mains supply. When the refrigerator is equipped also for 12 Volts D C operation the low voltage connection is made at the marked terminals at the rear of the refrigerator
2. Turn the knob A to desired position for electric operation
3. Turn the thermostat knob B to setting 4
To shut off the refrigerator turn the knob A to off position.
HOW TO USE THE REFRIGERATOR Food Storage Compartment
The food storage compartment is completely closed and un­ventilated, which is necessary to maintain the required low temperature for food storage. Consequently foods having a strong odor or liable to absorb odors should be covered. Vegetables, salads etc should be covered to retain their crisp­ness. The coldest positions in the refrigerator are underneath the cooling evaporator and at the bottom of the refrigerator, and the least cold positions are on the upper door shelves. This should be considered when different types of food are placed in the refrigerator.
NOTE: As soon as the necessary cold temperature in insi-
de the cabinet has been reached, adjust the ther­mostat knob to required setting.
Gas operation (Fig. 4b) with automatic reigniter
To start the refrigerator turn the knob A to position gas
1. Lamp E comes on.
Turn the gas thermostat knob B to setting 4.
2. Press the button C to stop and keep it depressed. When
3. lamp E goes out wait 15 sec. and release button C. If the lamp comes on again, repeat the procedure. If flame blow out reignition will take place automatically.
To shut off the refrigerator turn the knob A to off position.
NOTE:After a replacement of the gas container or a long
shut off period the gas line is likely to be filled with air. In such a case the lighting procedure has to be repeated until the air is pushed out of the line and the gas has reached the burner.
Defrosting
Some refrigerator models are equipped with an automatic defrosting device incorporated with the cooling unit. This devi­ce makes a quick defrost of the finned evaporator section about once a day without affecting the frozen food storage compartment or the frozen foods contained in it. When the frozen food storage compartment is covered with frost the refrigerator must be shut down temporarily till the frost is melted. Before the refrigerator is restarted the compartment should be dried, the ice trays washed and refilled with fresh water. When the frost on the finned evaporator section has melted water will be collected in the drip tray. The drip tray should be
emptied at regular intervals. Some refrigerators without the automatic defrosting device
should be defrosted regularly by turning off the refrigerator.
Empty the refrigerator leaving the drip tray under the finned
evaporator and the cabinet and freezer doors open. If desired, defrosting may be speeded up by filling the ice tray with hot water and placing it in the freezer. When all frost is melted, empty the drip tray and dry the
interior of the refrigerator with a clean cloth.
Replace the drip tray and ice tray, replace all food stuffs and
set the thermostat to MAX for a few hours. Then reset the
thermostat knob to its normal position.
9
Frozen Food Storage Compartment
The ice trays should be placed in direct contact with the freezer shelf for fastest ice making. Quick frozen soft fruits and ice cream should be placed in the coldest partment which is at the bottom of the aluminum liner or, in models with a shelf, on this or just below it. Frozen vegetables, on the other hand, may be stored in any part of the compart­ment. The compartment is not designed for the deep or quick fre­ezing of foodstuffs. Meat or fish foods, whether raw or prepa­red, and provided they are however, also be stored in the frozen food storage compart­ment. They can then be stored about three times as long as in the fresh food storage compartment. To prevent drying out, keep food in aluminum foil.
coverd
precooled
dishes, in plastic bags or wrapped in
part
of the com-
in the refrigerator, can
The Flame Failure Safety Device (Fig. 3)
The feeler of the the burner. To replace the
Remove the plastic cover 22 (Fig. 5).
1. Unscrew plug 20 and pull thermo-couple straight out.
2. Remove spring 21.
3. Pull out thermo-couple sideways from burner housing.
4. Bend the new thermo-couple to the same shape as the old
5. one. Reassemble in reverse order. Check that feeler has been
6. correctly refitted in relation to burner. See Fig. 3. Mount plug 20, taking care not to damage the threaded
7. hole in the aluminum cap of the housing. The plug must be properly tightened to the valve housing to ensure good contact between the thermo-couple and the magnetic coil within the housing.
thermo
couple shall reach in over two slots of
thermo
couple proceed as follows:
Ice Making
Ice cubes can be made in the ice trays which should be filled with water to within ice cubes seize the tray with both hands and twist the tray as shown in fig 0. Cubes not required should preferably be replaced in the tray. Refill the tray with water and replace the tray on the freezer shelf. Ice making is accelerated if the thermostat knob is turned to setting “MAX”. It is a good idea to do this a few hours before an anticipated need for ice but be sure to turn the knob back to normal setting when the ice is formed or the foodstuffs in the cabinet may become frozen hard.
1/4"
(5 mm) from the top. To release the
To Shut Off the Refrigerator
To shut off the refrigerator turn the knob A to off position. If the cabinet is not in operation over a period of weeks, it should be
emptied and cleaned and the door left ajar. Some models are provided with interior light, which comes on when the door is opened. To avoid running out of battery the light should be
shut off with the knob underneath the lamp housing. The ice trays should also be dried and kept outside the cabinet.
Cleaning
To clean the interior lining of the refrigerator use lukewarm weak soda solution. The evaporator, ice trays and shelves must, however, be cleaned with warm water only. Never use strong chemicals or abrasives to clean these parts or the protective surface will be spoiled. It is important always to keep the refrigerator clean.
The Thermostat
The refrigerator is equipped with a thermostat which is regula­ted by turning the knob to different settings in order to obtain the desired controlled cabinet temperature.
At OFF
At MAX
Between these two extremes is a numbered protion of the dial over which various controlled temperatures can be obtained, the higher the number, the lower the temperature. As soon as the required cold temperature inside the cabinet is reached, the thermostat cuts the burner main flame leaving the by-pass flame to keep the safety valve open.
Under normal operating conditions the thermostat valve remains closed and the burner is running con­tinuously at the by-pass rate, just enough to keep the burner lit.
The thermostat valve remains open and the burner is running continuously at full gas rate. Lowest cabi­net and freezer temperatures are obtained at this setting.
The Igniter
The refrigerator is fitted either with a piezo igniter (see fig. 4a)
or an automatic reigniter (see fig. 4b). which does not normally need any maintenance. If the igniter does not work properly
contact an authorized service point.
CAUTION
Do not store explosive substances in the refrigerator, such
as cigarette lighter gas, petrol, ether or the like.
GAS EQUIPMENT Flue Top and Baffle
The flue baffle is suspended from the top and must be in position in the central tube of the cooling unit.
The Burner and the Burner Jet (Fig. 2)
The slots of the burner must be centrally located under the
boiler tube.
See “Periodic maintenance”.
10
ELECTRIC EQUIPMENT Cartridge heater
The refrigerator is equipped also for electric operation. Most models are equipped for both 120 Volts A C and 12 Volts D C operation. The heat necessary for the operation of an absorption type cooling unit is supplied by an electric cartridge heater mounted in a pocket of the boiler system.
To replace the heater first of course check that the wall plug is disconnected. If the refrigerator is equipped also for 12 Volts D C operation make sure that the 12 V leads are disconnec­ted. Then proceed as follows:
1. Remove the plastic cover (22) of the main control structure by loosening the two screws
2. Disconnect the heater leads
3. Pull off the metal hose
4.5.With a pair of pliers unfold the lug holding the lid of the boiler casing and open the lid Remove some insulation wool so that the heater is acces­sible. Turn and lift the heater out of its pocket
6. Fit the new heater into the pocket and pull on the hose
7. around the leads
8..
Connect the leads and put on the plastic cover Reset the insulation and close the lid of the boiler casing
9.
The Switch
The electric control also comprises an on-off switch operated by the selector knob at the front panel. The switch has two “on’‘-positions, one for 120 Volts A C (ELEC.) and one for 12 Volts D C operation.
WARNING
If the refrigerator is used intermittently it should be checked at least once a year.
It is important to keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquides. Check the venting system. The flow of
combustion and ventilating air must not be obstructed.
Check the flue baffle that it is clean and reasonably free
from soot. Heavy soot formation indicates improper func-
tioning of the burner. Clean baffle and flue. Further, clean cooling unit and floor under refrigerator.
The entire gas installation should be checked for leaks at
intervals. Test all pipe connections with soapy water, not
with an open flame.
NOTE. Any service of the gas controls, with exeption
for the above mentioned replacement, maintenance
and cleaning operations must be performed by an au-
thorized service center only.
FAULTTRACING
The Thermostat
The electric thermostat is combined with the gas thermostat and is thus operated by the knob B at the front panel. The temperature in the refrigerator can be regulated by turning the thermostat knob to higher or lower numbers. Although the exact setting is not critical choose a setting at which the frost which gradually forms on the cooling evaporator is just mainta­ined in dry condition.
It will be necessary to set the thermostat knob one or two
numbers higher when the ambient temperature becomes hig-
her or the load unusually heavy. If less cooling is required a lower setting should be chosen.
PERIODIC MAINTENANCE
NOTE.Before working on the refrigerator make sure that 120 V A.C. and optional 12 VD.C. leads are disconnected.
The Burner and the Burner Jet (Fig. 2)
The
colour
of the flame shall be clear blue over the slots of the burner (Fig. 3). Once or twice a year depending on use, it is necessary to clean and adjust the burner assembly. Proceed as follows:
1. Loosen screw and remove cover plate for burner housing.
2. Disconnect lighter cable from the electrode.
3. Loosen burner fixing screw and withdraw burner.
4. Clean burner tube
5.
Screw off jet and clean with alcohol. Blow with compressed air. Never use a needle or similar.
6. Reassemble.
with
a brush. Blow with compressed air.
The Electrode
For a proper ignition function it is necessary to keep the
electrode insulation dry and free from dirt The gap between
burner tube and electrode shall be max. 1/8" (3 mm).
3/16"
(5 mm) and min.
The refrigerator does not freeze satisfacto­rily Causes and remedies
a) Jet orifice clogged. Unscrew jet and blow clear or wash in
alcohol. Do not use wire or pin to clean orifice. b) Check the leveling of the refrigerator. c) Flame has gone out. Remedy: 1) Gas in bottle is used up
refill. 2) Feeler point of the flame failure safety device is not
heated enough by flame
3) Clogged by-pass screw
d) Air circulation around cooling unit is restricted. Be sure that
refrigerator is property ventilated. e) The evaporator is heavily coated with frost. Defrost. f) Flue baffle not inserted into the central tube of the cooling
unit.
g) The thermostat is incorrectly used. See paragraph on
thermostat. In hot weather the setting should be one or two
numbers “colder” than usual. h) Gauze in burner head clogged. Clean. i) Burner damaged. Replace. j) Burner may be dislocated. Relocate. k) Wrong gas pressure at the burner. Have pressure checked
at burner and at gas bottle. Pressure at burner must not fall below 11
"
W.G. when thermostat is set on MAX.
-
check against fig. 2 or 3.
-
clean or exchange it.
ODOR FROM FUMES Causes and remedies
a. The flame touches side of the boiler due to dislocation of
the burner. Relocate. Burner dislocation may also cause
smoke and discoloring of walls and ceiling. b. Burner damaged. Replace. c. The flame touches flue baffle. Remedy: 1) Burner dama-
ged. Replace. 2) Flue baffle too low. Correct the position of
the baffle.
d. The flue tube is dirty. Clean flue as follows: Cover burner
and jet. Remove flue top and baffle. Clean flue with special
flue brush. Clean baffle before putting back in place. All the above instructions are to be followed closely. The
refrigerator is quality-guaranteed. However, we are not re­sponsible for any failures caused by improper adjustments and unfavorable installation conditions. Contact service point or distributor service dept. for assistance.
Replacement Parts Suppliers: See cover.
-
11
INSTRUCTIONS
FOR MOUNTING THE DOOR PANEL
The refrigerator is normally delivered without door panel(s).
Before starting the mounting work check that the panel di­mensions are in compliance with those given in the table and read the instructions through. When mounting the panel, pro­ceed as follows.
A.
Remove the top decoration strip (2) with its two screws (1).
B.
Insert one of the vertical edges of the panel into the
groove of the door frame (3).
C.
Bend the panel gently so that the free side of the panel can be slipped into the corresponding groove of the door frame (4).
D.
Push the panel downwards so that the lower horizontal edge of the panel is fitted into the bottom groove (5).
E.
Between the upper edge of the panel and the door frame there is now a gap which should be covered by the de­coration strip.
F.
Put the strip across the door so that the gap is covered and push it upwards (6). The tabs on the inside of the strip should fit in behind the flange of the door frame. Secure the
decoratlon
strip
by means of the two screws (1).
Panel dimensions
Thickness max. 5/32”
T
TYPE
RM 360
RM 460
RM 660
RM 760 upper
RM 760
lower RM 1300 upper
RM 1300 lower
HEIGHT
L
MAX.
636 25”
679 26 23/32
879 34 5/8
288 11 11/32
801 798 31 17/32 31 13/32 360 357
14 3/16 14 1/16
879 34 5/8
633
24 7/8
676 26 19/32
876 34 1/2
285 11 7/32
876 34 1/2
MIN.
1
MAX.
516.5 20 11/32
550.5 21 11/16
550.5 21 11/16
550.5 21 11/16
550,5 21 11/16
598.5 23 9/16
598.5 23 9/1 6
WIDTH
1
MIN.
513.5 mm 20 7/32 inch
547.5 mm 21 9/16 inch
547.5 mm
21 9/16 inch
547.5 mm
21 9/16 inch
547.5 mm 21 9/16 inch
595.5 mm 23 7/1 6 inch
595.5 mm 23 7/1 6 inch
HK-M 7937 820 47 96
FPC 119
RM-3-4-6-7-13
Loading...