WARNING: Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Refer to
this manual. For assistance or additional
information consult a qualified installer,
service agency or the gas supplier.
FIRE OR EXPLOSION HAZARD
If you smell gas:
1. Open windows.
2. Do not attempt to light appliance.
3. Do not touch electrical switches.
4. Extinguish any open flame.
5. Shut off fuel supply.
6. Evacuate immediately and call emergency
services.
Failure to follow these instructions could result
in fire or explosion, which could cause property
damage, personal injury, or death.
Refrigerator
NORTH AMERICAN ADDRESS INFORMATION
USA & CANADA
Service Office
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
This manual has safety information and instructions to help you eliminate or reduce the risk of accidents
and injuries.
1.1 Recognize safety information
This is the safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
1.2 Understand signal words
A signal word will identify safety messages and property damage messages, and will indicate the degree or level
of hazard seriousness.
indicates a hazardous situation that, if not avoided, could result in death or serious injury.indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.is used to address practices not related to physical injury.
indicates additional information that is not related to physical injury.
I
1.3 Supplemental directives
Read and follow all safety information and instructions to avoid possible injury or death.
Read and understand these instructions before installation of this product.
Incorrect installation of this product can lead to serious injury.
The installation must comply with all applicable local or national codes, including the latest edition of the
following standards:
This appliance is certified under the latest edition of ANSI Z21.19, CSA 1.4 Refrigerators using gas fuel. The
installation must conform with local codes, or in absence of local codes, the following standards as applicable:
U.S.A.
• ANSI/NFPA70, National Electrical Code (NEC)
• ANSI/NFPA 1192, Recreational Vehicles Code
• Title 24 CFR, Part 3280, Manufactured Home
Construction and Safety Standard
• National Fuel Gas Code, ANSI Z223.1/NFPA 54
Canada
• CSA C22.1, Parts l & ll, Canadian Electrical Code
• CSA Z240 RV Series, Recreational Vehicles
• CSA Z240.4, Gas-Equipped Recreational Vehicles
and Mobile Housing
• CSA B149.1, Natural Gas and Propane Installation
Code CERTIFICATION
1.4 General safety messages
Failure to obey the following warnings could result in death or serious injury:
• This product must be installed by a qualified service technician.
• Any modifications or deviations:
– Can lead to carbon monoxide leaking into the living area.
– Can reduce cooling performance and/or result in damage to the refrigerator.
– Will void agency certifications.
– Will void refrigerator warranty.
• ELECTRICAL SHOCK HAZARD. This product is equipped with a three-prong (grounding) plug for protection
against shock hazards. This product should be plugged directly into a three-prong receptacle that provides
grounding in compliance with all applicable electrical codes. Do not cut or remove grounding prong from
plug.
3
EN
Refrigerator
• FIRE OR EXPLOSION HAZARD:
– Before refueling or parking near a gasoline pump, make sure all LP gas appliances (vented to the outside of
RV) are shut off . Otherwise, fumes from gasoline pumps could come into contact with an LP gas appliance
burner flame and ignite.
– Do not store or use gasoline, oil- or gasoline-soaked rags, or other flammable vapors and liquids in the
service area behind the refrigerator or in the vicinity of this or any other gas appliance.
• ABSORPTION-COOLING SYSTEMS: FIRE, BURN, OR INHALATION HAZARD. Do not fracture or puncture
cooling unit. The cooling unit is under pressure and contains ammonia, sodium chromate, and other
chemicals. Repeated or prolonged exposure to sodium chromate could cause organ damage or cancer.
Exposure to a high concentration of ammonia refrigerant could cause pulmonary edema (fluid in lungs);
chemical burns to eyes, lungs, and skin; and could cause a fire (when exposed to open flame).
• COMPRESSOR-COOLING SYSTEMS: FIRE, FROSTBITE, OR INHALATION HAZARD. Do not fracture or
puncture cooling unit. The cooling unit is under pressure and contains tetrafluoro ethane refrigerant, and may
contain other chemi cals. Contact with liquid refrigerant could cause irritation or frostbite to eyes and skin.
Exposure to a high concentration of refrigerant could cause cardiac arrhythmia (irregular heartbeat). A high
concentration of refrigerant could cause a fire (when exposed to open flame).
• FIRE OR INHALATION HAZARD. If the refrigerator stops working and/or it emits an ammonia smell,
immediately turn refrigerator off (if it is safe to do so), leave the vicinity, and contact a qualified Service Center.
• LIFTING HAZARD. Use proper liing technique and control when liing the product.
2 GENERAL INFORMATION
Optional Parts*Reference Number
Innovator Refrigerator Ventilation
System
Z-bracket3103812.xxx
*Available as accessory (not included)
3108705.751, 3108705.744
3 INTENDED USE
The DM and RM refrigerators are designed and intended for use only inside a recreational vehicle (hereinafter
referred to as “RV”) for which it is supplied. Use the instructions to ensure correct installation of the refrigerator.
Dometic Corporation accepts no liability for damage in the following cases:
• Faulty assembly or connection.
• Damage to the product resulting from mechanical influences and excess voltage.
• Alterations to the product without expressed permission from Dometic Corporation.
• Use for purposes other than those described in the operating manual.
Dometic Corporation reserves the right to modify appearances and specifications without notice.