Dometic DTM04, DTM12, DTM08 Installation And Operational Manual

Page 1
TANK MONITOR SYSTEMS
DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR
INSTALLATION AND OPERATION MANUAL
1
Page 2
TANK MONITOR SYSTEMS
ENGLISH
Safety Instructions 2
Features 2 - 3
Specications 3
Installation 4 - 5
Wiring Diagrams 6 - 7
Warranty 8
FEATURES
SAFETY INSTRUCTIONS
WARNING: When using this device, always exercise basic safety precautions, including the following:
• Read all instructions before installation or use.
• Never connect this device to any electrical circuit with other than 12 or 24 volt Direct Current or exceed the amperage draw listed below.
• Never install the indicator panel in an atmosphere with potentially ammable or explosive vapors.
• Never install the probe cap with oat switches into a tank that contains anything other than fresh, gray or black water.
CAUTION: Dropping or rough handling of oat switches may result in damage.
Probe
Cap
Adjustable
DTM04 DTM08 DTM12
Tank Monitor Systems
Dometic Tank Monitor Systems permit remote sensing of liquid levels in black or gray waste water, or potable freshwater tanks. Three oat switches, which activate a set of four lights, are installed in the desired tank. One oat activates a “Full” light when the liquid is within 2 inches (51 mm) of the top inside surface of the tank. The other oat switches are mounted on adjustable stems and can be positioned to within 2 inches of the tank bottom. The stems are semi-exible and ex with the sloshing of the tank contents. One oat can be positioned to sense when the tank is empty and the others to sense when the tank is 1/4 or 1/2 full, depending on the application.
Tank Monitor Application Chart
DTM04 DTM08 DTM12
Blackwater waste
Freshwater supply
Graywater waste
Stems
Float Switches
Page 3
FEATURES (continued)
• Four lighted level indicators for each tank application. One light is always “on” to indicate system power.
• Flexible probe design eliminates false readings from fouled oat switches.
• Available probe lengths t tanks up to 22 inches (559 mm) or 45 inches (1143 mm) in depth.
• Panel complements bathroom decor. International symbology eliminates confusion.
• Installs in any rigid tank with optional 3-inch NPT mounting ange.
• Each system operates on either 12 or 24 VDC.
• Probe cap provides clean-out tting for easy access to tank interior.
• Vent hose connection in probe cap (if applicable) permits connection of 5/8-inch (16 mm) vent hose.
• Optional shut-down relay plugs into circuit board to shut down toilet system when gray or black water waste tank is full (DTM04 model only).
• Only one level light on at a time to eliminate confusion and save battery power.
• CE approved for electromagnetic compatibility.
SPECIFICATIONS
Electrical Current Draw
12 VD C DTM04 DTM08 DTM12
Without shut-down relay 0.008 A 0.016 A 0.024 A
With shut-down relay 0.14 5 A N/A N/A
24 VDC DTM04 DTM08 DTM12
Without shut-down relay 0.004 A 0.008 A 0.012 A
With shut-down relay 0.090 A N/A N/A
Dimensions
* Max length for 45-inch probes is 43 3/4-in. (1111mm).
Page 4
TANK MONITOR SYSTEMS
INSTALLATION
Adjustable Tank Probe Cap
1. The tank probe cap is designed for a 3-inch FPT opening. Order part number 230272 if tank is made of rigid material and is not a SeaLand holding tank.
2. Loosen compression nuts on adjustable probes and install the cap into the tank. Slide the #1 probe down until the oat touches the bottom of the tank. Tighten #1 compression nut and mark the probe at the top of the nut with a pen or pencil. Do not cut the probe’s tubing at this mark. Loosen the compression nut, slide the probe up, and carefully cut the #1 probe’s tubing 1-5/8 inch (41.3mm) below the mark without damaging the switch wires. Pull the wires through the black wire cover and push the probe down into the compression nut until the black wire cover touches the compression nut.
3. Remove cap from tank and adjust the #2 probe for 1/2 full level for gray and black water tanks or 1/4 full level for freshwater tanks. Tighten the compression nut and cut the probe’s tubing off 3/8-inch (9.5mm) above the compression nut without damaging the switch wires. Slip the black wire cover onto the top of the stem.
4. To make the #1 oat switch activate the “Empty” light, the oat must be positioned with the recessed shoulder, white band, or the letters “NO” at the bottom. Remove the C-clip from the switch body, ip the oat 180 degrees, and replace the C-clip. (See Diagram #1.)
5. The #2 oat switch can activate the “Mid” light on black and gray water tanks and activate the “Low” light on freshwater tanks. The recessed shoulder, white band, or the letters “NO” should be facing up for black and gray water tanks and down for freshwater tanks. (See Diagram #2.)
6. Route 18-gauge stranded copper wire from the indicator panel to the level indicator cap. Use quick-discon­nect terminals on oat switch wires to prevent twisting wires when removing the cap. With cap removed from the tank, connect the wires according to the wiring diagram and test the oats by moving them up and down. Disconnect the wires and install the cap with the O-ring into the tank, then reconnect the wires.
7. For caps with vents, route 5/8-inch vent hose from the through-hull tting to the vent connection on the level indicator cap. Use stainless steel hose clamps to secure the vent hose connection.
Monitor Panel
1. Select a mounting location away from direct contact with water and oil. Dry locations in the bathroom, salon or galley are most desirable.
2. Conrm clearances for the panel and wire connections behind walls, hull liner or bulkhead.
3. Cut out mounting holes (see template for panel and fastener hole locations.)
4. Do not mount the circuit panel until wiring is routed and properly connected.
5. Route wires following the appropriate wiring diagram for black, gray or fresh water applications.
6. Include wires for optional electrical accessories that may be part of the installation and shown in separate wiring diagrams.
7. Install the circuit panel with the four #6 fasteners provided. Make sure to install with the “UP” arrow pointing in the proper direction.
8. Push the panel cover onto the circuit panel until it snaps into place.
Page 5
INSTALLATION (continued)
Universal Tank Flange Kit (optional)
1. Find and mark the top center of the tank.
2. Cut a 4 1/16-inch diameter hole in the top center of the tank.
3. Slip the ange into the hole and mark the location of the ve mounting holes.
4. Drill the ve mounting holes with a 1/4-inch drill bit.
5. Remove the ange, clean all oils, grease and dirt from the mounting surface and allow to dry.
6. Apply liberal amounts of silicone rubber adhesive to the mounting surface and the underside of the ange.
7. Insert the gasket into the ange and align with the ve mounting holes.
8. Secure the ange with the screws, nuts and washers provided.
9. Install the probe cap and, if applicable, secure the 5/8-inch vent hose to the vent tting with a stainless steel hose clamp.
Shut-down Relay (optional – applies to DTM04 only)
CAUTION: VERIFY THAT RELAY IS CORRECT VOLTAGE FOR SYSTEM (12VDC requires P/N 600341292 and 24VDC requires P/N 600342490).
1. Insert a small screwdriver behind the top or bottom slot of the panel cover and pry it outward. Remove panel cover from circuit panel.
2. Remove the four mounting fasteners and pull the circuit panel out of the wall or hull liner, exposing the
wiring connections.
3. Insert the shut-down relay into the socket on the back of the circuit panel.
4. Reinstall the circuit panel to the wall.
5. Route the additional wires (use 12 or 14 gauge stranded copper) to wires 10 and 11 on pigtail to interrupt power for the toilet system. (See shut-down relay wiring diagram for application details.)
6. Turn on power and test circuit.
7. Complete installation to wall.
Flange Kit Assembly
Tan k
surface
Page 6
WIRING DIAGRAMS
DTM04 Tank Monitor System for Blackwater Waste Tank
TANK MONITOR SYSTEMS
USE 18GA. OR LARGER STRANDED COPPER WIRE.
IF OPTIONAL “TANK FULL” SHUT-DOWN RELAY IS INSTALLED, PINS 10 AND 11 REQUIRE 14GA. OR LARGER STRANDED COPPER WIRE.
BLACKWATER TANK NOTE: RECESSED SHOULDER, THE WHITE BAND, OR THE LETTERS "N-O" OF THE “EMPTY” FLOAT ARE DOWNWARD.
DTM08 Tank Monitor System for Blackwater and Freshwater Tanks
DTM04 TANK
MONITOR
USE 18GA. OR LARGER STRANDED COPPER WIRE.
BLACKWATER TANK NOTE: RECESSED SHOULDER, THE WHITE BAND, OR THE LETTERS "N-O" OF THE “EMPTY” FLOAT ARE DOWNWARD.
FRESHWATER TANK NOTE: RECESSED SHOULDER, THE WHITE BAND, OR THE LETTERS "N-O" OF THE “EMPTY” AND “MID” FLOAT ARE DOWNWARD.
DTM08 TANK
MONITOR
Page 7
DTM12 Tank Monitor System for Blackwater and Graywater Tanks, and Freshwater Tank
USE 18GA. OR LARGER STRANDED COPPER WIRE.
BLACKWATER AND GRAYWATER TANK NOTE: RECESSED SHOULDER, THE WHITE BAND, OR THE LETTERS "N-O" OF THE “EMPTY” FLOAT ARE DOWNWARD.
DTM12 TANK
MONITOR
FRESHWATER TANK NOTE: RECESSED SHOULDER, THE WHITE BAND, OR THE LETTERS "N-O" OF THE “EMPTY” AND “MID” FLOAT ARE DOWNWARD.
Shut-down Relay with DTM04 Tank Monitor System
USE 12 OR 14 GAUGE STRANDED COPPER WIRE ON PINS 10 AND 11.
WITH RELAY INSTALLED AND DTM04 MODEL WIRED FOR A BLACKWATER TANK, THE “FULL” FLOAT SWITCH WILL SHUT OFF ELECTRICAL POWER TO THE TOILET SYSTEM.
DTM04 TANK
MONITOR
with
shut-down relay
Consult toilet system specications for proper fusing or circuit breaker size. Do not exceed 30 amps.
7
Page 8
TANK MONITOR SYSTEMS
MANUFACTURER’S ONE-YEAR LIMITED WARRANTY
Dometic Corporation warrants, to the original purchaser only, that this product, if used for personal, family or household purposes, is free from defects in material and workmanship for a period of one year from the date of purchase.
If this Dometic product is placed in commercial or business use, it will be warranted, to the original purchaser only, to be free of defects in material and workmanship for a period of ninety (90) days from the date of purchase.
Dometic reserves the right to replace or repair any part of this product that proves, upon inspection by Dometic, to be defective in material or workmanship. All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser-user.
EXCLUSIONS
IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, FOR DAMAGES RESULTING FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED BY NEGLECT, ABUSE, ALTERATION OR USE OF UNAUTHORIZED COMPONENTS. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF ONE YEAR FROM DATE OF PURCHASE.
IMPLIED WARRANTIES
No person is authorized to change, add to, or create any warranty or obligation other than that set forth herein.
Implied warranties, including those of merchantability and tness for a particular purpose, are limited to one (1) year from the date of purchase for products used for personal, family or household purposes, and ninety (90) days from the date of purchase for products placed in commercial or business use.
OTHER RIGHTS
Some states do not allow limitations on the duration of an implied warranty and some states do not allow exclusions or limitations regarding incidental or consequential damages; so, the above limitations may not apply to you. This warranty gives you specic legal rights, and you may have other rights which vary from state to state.
To obtain warranty service, rst contact your local dealer from whom you purchased this product.
REVISION A
Form No. 600345620 6/17 ©2017 Dometic Corporation
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
Page 9
INSTALLATION TEMPLATE – MONITOR PANEL
Use this template with Dometic Monitor Panel installation instructions on page 4.