PREPARATION
INSTALLATION
INSTALLATION
MV950TIR
IP 5MP Vandal Dome Camera
Quick Setup Guide
The following items are included with the MV950TIR Camera
MV950TIR
Quick Start
IP 5MP Vandal Dome Camera
Guide
L-Wrench
2nd Video
Output Adapter
2x Drying
Agent- Silica
Gel Packet
CD
(Manual &
Software)
Waterproof
Acessories
& Power
Outlet Adaptor
DC Cable
Adapter
Mounting
Template
3x Mounting
Screws and Wall
Anchors
Vandal Dome
Camera
Mounting the Camera
Using the camera base or the mounting
1
template, mark and drill 3 pilot holes and
insert anchors. Use screws to affix the
camera base to the ceiling or wall.
3
3
Adjust the camera lens using tilt &
swivel controls as needed.
Use the Zoom and Focus hadles to
adjust the camera’s lens.
Pull all necessary wires through and use
2
the diagram on page 2 of this QSG to
make all proper cable connections.
4
After adjusting lens, remove a drying
agent pack from one of the silver
packages stored inside the accessories
package*.
Remove the sticker from the drying
agent pack and insert in the front
under the lens as shown in the image*.
BNC 2nd Video Output
The camera can provide video out via BNC cable. The BNC cable provided has a 2 pin
plug. When connecting the BNC cable for SDTV video out, connect the BNC cable to
pin 3 & 4 as shown in the image above.
IR Sync. Function
If using an external IR trigger, then connect the external IR device
to the camera’s 2-pin IR Sync port.
Additional Cabling Connections
1x RJ45 Netowkr Port
1x RJ45 Connector
2x Sensor Input
Audio In/ Out
DC Power
Resetting the Camera
Pressing the reset button on the camera’s control board, while the camera is on, for six (6) seconds will initialize
all environmental variables to factory default. Previous setup for IP default, time, etc. will be reversed to its
factory default values. The following are the default network settings:
IP Mode DHCP
IP Address 192.168.1.2
Subnet Mask 255.255.255.0
Gateway 192.168.1.1
RTP Video Port 6002
HTTP Port 80
RTSP Port 554
Frequent use may cause a System Error
TEL: (866) 446-3595
www.Digital-Watchdog.com / technicalsupport@dwcc.tv
Technical Support Hours: Monday-Friday 9:00AM to 8:00PM EST
!
08 21 20 13
Reset Switch
2
Thank you for purchasing Digital Watchdog’s MEApix IP Vandal Dome Camera.
Before installing the camera, please verify your model and read this guide carefully.
Network Connection
There are two options.*
1
Using a PoE-Enabled Switch
The MEGAPIX Camera is PoE-compliant, allowing transmission of power and data via a single
ethernet cable. Follow the illustrations below to connect the camera to a PoE-enabled switch using
an ethernet cable.
2
Using a Non-PoE Switch
If a PoE-enabled switch is not used, use a power adaptor to connect the MEGAPIX Camera to a
Non-PoE switch.
The drying agent pack should be replaced each time the camera is opened (front or back).
Be sure to complete all work before inserting drying agent pack & replacing the cover.
3 5 7
Drying agent packs will become ineffective if exposed to open air for more than 10 minutes.
Mounting the Camera
Water Resistant Accessories
5
Prepare conduit, and slide necessary cables through tubing. After subsequent
cabling is done, insert tubing into A and screw C on to A.
Wall Mount Bracket
6
Run all necessary cables through the bracket before securing the bracket to the wall.
7
Mount the Wall Mount to the wall using the mounting template or the bracket itself.
8
Secure the camera housing to bracket and secure by tightening the screws;
be sure to pass cabling into hole in the camera housing.
4
!
Camera Specifications
Camera Specifications
IMAGE
Image Sensor 1/2.5” 5MP CMOS Sensor
Total Pixels 2592 (H) X 1920 (V)
Minimum Scene Illumination 0.0 Lux
LENS
Focal Length 3.4~10mm
Lens Type Varifocal/ DC- Iris
IR Distance 50ft Range IR
Angle of View Horizontal: 40 (wide) - 25 (tele)
AUDIO
Compression and Sampling Rate G.711/ G.726/ AAC
Input / Output Built-in Microphone, 1x Line In and 1x Line Out
NETWORK
LAN 802.3af Compliance
Video Compression Type H.264 H.264, MPEG4, MJPEG
Resolution 10fps @ 2560x1920 (5MP) 10fps@2592x1920(5MP) /
20fps@2048x1536(3MP) /
30fps@1920 x1080(2MP)
Frame Rate Up to 10fps Up to 30fps based on Resolution
Streaming Capability Dual-Stream at Different Rates and Resolutions
IP IPv4, IPv6
Protocol TCP/IP, HTTP, DHCP, PPPoE, HTTPS, ICMP, ARP, RTSP,
NTP, UDP, NTP, SMTP, RTP, RTCP, 3GPP, SAMBA (NAS)
Maximum User Access 10 Users
ONVIF Conformance Yes , Profile S
Web Viewer OS: Windows XP / Vista / 7, MAC OS
Browser: I.E. 8 or Higher, Chrome, Firefox, Safari
Video Management Software DW Spectrum
Memory Slot Micro SDHC Card (4GB-32GB) Card Not Included*
ENVIRONMENTAL
Operating Temperature/ Humidity -25
Operating Humidity Less than 80% (Non-Condensing)
Storage Temperature -29oC ~ 55oC (-20oF ~ 131oF)
IP Rating IP66 (Protects against dust and high pressure water)
Other Certifications CE, FCC, RoHS
ELECTRICAL
Power Requirement DC 8~25V, AC 24V, PoE (IEEE802.3af Class 3)
Power Consumption Max 8.9W, 600mA
MECHANICAL
Material Aluminum Housing
Dimensions 152 X 98 mm (5.98 X 3.85 in)
6 8
Weight 2.42 lbs
DW Optimized Firmware Full Firmware Option
o
C ~ 55oC (-13oF ~ 131oF)
MEGAPIX CAMERA SETUP
Installing DWScan
DWScan searches for all the available supported network devices on
your local area network.
1
Install DWScan to find the MB950TIR Cameras on the local network. The
DWScan software can be found on the included CD. Run DWScan and install onto your
PC.
2
When setup is complete, launch the DWScan software.
3
To find your MB950TIR cameras, click the Scan button.
4
You can use the DWScan software to adjust the camera’s IP Address and Network Settings
5
To change the camera’s Network Settings, press the Change Settings button.
Accessing the Camera
Web Viewer Interface
Video Display Size
Video Controllers
Alarm Indicators
Video Resolution & FPS Information
Audio Controllers
Lens Controllers
PTZ Virtual Controller
Stream Selection
9
Live/ Setup/ Client Setup Access
11 13
Relay Input and Alarm Output Control
Remote Video Monitoring
Use the camera’s control bar and status
indicators to manage the camera’s relay and
alarm inputs and outputs.
- Digital IN Alert will blink to notify you when a
relay connected to the camera is triggered.
- Use the Digital Out button to start/ stop any
alarm output connected to the camera.
Refer to the full manual for more information
on how to setup relay input and output control
in the camera.
Instant Recording
Instantly record live video to your local drive.
User1
To Setup Instant Recording
Make sure the directory path is setup. To do so go to Client Settings at the top right-hand corner of
the screen and press ‘Select Path’
To Start and Stop Instant Recording
To Start, press the icon on the control menu bar. A window will appear to notify you instant recording has begun.
The button will blink red indicating you are currently recording video.
To Stop, press the button again. The video file will appear in the designated directory path.
15
Accessing the Camera Using its Web Browser
For advanced setup and camera view, access the camera using its
built-in web server.
When accessing an IP camera using the web interface for the first time (or when the IP
address changes), some configuration for ActiveX controls are required.
1. Open an IE browser
2. Type in the IP address in the URL: http://<IP ADDRESS> (e.g. http://10.1.21.53).
3. Default Username and Password: root/ pass.
4. Pop-up windows and messages for download/run Active X controls (examples below)
will likely be displayed. Select Install or Run
to all such messages. Click on the add-on
message and choose Run Add-on.
5. Repeat the above until all ActiveX
controls have been initiated. Once the
process is complete, the Live View will be
displayed in IE.
6. When all Active X files have been
properly installed, the web viewer will
display the camera’s live video and control
center.
The web viewer can also be accessed via Firefox
and Google Chrome if QuickTime player is installed.
Webviewer Specifications
Minimum Requirements for PC
CPU
RAM
HDD
OS
Resolution
TEL: (866) 446-3595
www.Digital-Watchdog.com / technicalsupport@dwcc.tv
Technical Support Hours: Monday-Friday 9:00AM to 8:00PM EST
Intel P4 2.0GHz Dual Core
More than 1GB
200GB Required for Saving Clip Image
Microsoft Windows XP or Higher
Higher than 1024X768
10
Export Image
Not available in the DW Optimized Firmware
User1
!
1. Make sure the directory path has been setup. To do so:
a. Go to Client Settings at the top right-hand corner of the screen.
b. Press ‘Select Path’ to select the directory where all exported images will be saved to.
Settings will be saved automatically.
2
c. Click on the ‘Live View’ link at the top right-hand corner of the screen to return to the camera’s
live display.
2. To export an image of the camera’s current live view, press the button at the top control bar.
An image with time stamp will automatically be saved as a JPEG file.
12
Stream Setup and Selection
The MB950TIR supports multiple simultaneous streams (up to 4 different profiles). The
Streams can be switched from the camera’s web viewer by selecting the corresponding
stream from the drop down menu in the Stream Control option.
The stream’s current resolution and framerate information will be displayed in the
information section.
To setup the different streams:
a. Go to ‘Setup’ at the top right-hand corner of the screen. The setup menu will appear.
b. Go to Video/Audio > Video Settings
c. Select the number of profiles you would like to assign the camera.
d. All selected profiles will appear under the Quality Setting Section. Here you can modify
each streams’ resolution, codec, bitrate, and max framerate.
e. Press ‘Save’ to save all settings.
14
SD Card Installation & Setup
The MB950TIR supports local storage recording as well as remote
FTP and NAS recording. All recording settings can be done by pressing
‘Setup’ in the upper right-hand corner of the screen.
16