![](/html/0e/0ef6/0ef61c70c339b4de5549dd31b02fc603d1011527dbb4b3baa32de493645d0de2/bg1.png)
Stock Weigh 14000
Part # Description Qty. Required
400161 Rail Assembly – 44” SW14K
403858 Rail Assembly – 44” SW14K
(Requires J-Box)
(Spliced)
2
2
790 W Rockwell Avenue, Fort Atkinson, WI 53538
Phone: (800) 225-7695 Fax: (920) 563-9721
www.digi-star.com
sales@digi-star.com
techsupport@digi-star.com
![](/html/0e/0ef6/0ef61c70c339b4de5549dd31b02fc603d1011527dbb4b3baa32de493645d0de2/bg2.png)
Installation:
The scale must be installed on a flat, level, and well-drained surface. Concrete is preferred. Shim under the scale
as required. Usually flatness within ±1/8” is required.
The scale is approximately 4” high. Ramps or a shallow pit may be required to facilitate animal access if used as
an animal scale. If a pit is used, adequate drainage is a MUST.
Assemble loadcells and components as shown. The scale will NOT function properly if the upper mounts are not
installed correctly. Note “Bending Direction” decal on end of loadcell for proper installation (arrow should always
point UPWARD).
Position assembled unit as desired on the mounting pad. Mark all holes to be drilled using the parts as a
template. An angle iron bracket may be welded to the chute to provide mounting surfaces for the top mounts.
Mounting hardware is not provided. Grease all hardware with a weather resistant grease to make subsequent
disassembly easier.
The chute should be restrained with a horizontal chain or other flexible means if the scale system is not bolted to
concrete. The scale will not weigh accurately if the restraining method prevents weight from being transferred to
the scale.
Extension tube may be cut down to provide a custom scale width. Simply re-drill the mounting cross-hole after
cutting down the pipe on one end.
Wires and cables must be stowed and secured safely to prevent damage. Secure all cables up off ground and
away from animals with nylon ties or other fasteners.
If mounts are to be welded in place, loadcells must be disconnected from the indicator. Also, the ground should
be located so as to prevent the loadcell from being in the current path.
Maintenance:
There are no moving parts and no lubrication required. The only maintenance required is periodic cleaning of the
mounts and the area below the scale to assure free and unencumbered operation of the scale. Stand over each
of the 4 corners to troubleshoot for problems. Corners should weigh the same within ±2 display counts. Scale
system accuracy is ±1% maximum error.