MAINS VOLTAGE LED
Deta Electrical Company Ltd
Kingsway House Laporte Way
Luton Bedfordshire LU4 8RJ UK
Tel. 01582 544 544 Technical Helpline 01582 544 548
Installation Instructions
Ensure the power supply is switched off before
fitting, servicing or changing a lamp.
Ensure adequate free air ventilation is allowed
around the light fitting, and their use does not
breach any fire regulations.
Loft insulation can be laid loosely over this light
fitting, but must not be compacted around it.
The light fitting should not be installed near to
any heat sources or in area with an ambient
temperature above 30°C.
The light fitting and lamp can become very hot
during use. Ensure the fitting has cooled before
handling.
The nearest illuminated surface must be at least
0.5m from the front of the fitting.
If replacing the lamp, ideally it would be a GU10
LED lamp. This downlight is rated for GU10
tungsten halogen lamps with aluminised / heat
forward reflectors.
When fitting or replacing the lamp, ensure it is
correctly located.
This light fitting must be installed in accordance
with the current edition of the IEE Wiring
Regulations BS7671.
If in doubt, contact a qualified electrician.
Switch off the electricity at the fuse box by
removing the relevant fuse or switching off the
circuit breaker before proceeding with the
installation.
Cut a hole in the ceiling (see table below for hole
sizes) and ensure adequate minimum ceiling void
without infringing on joists, water pipes or
electrical cables.
All insulating materials should be away from the
light fitting.
Connect the light fitting to the supply cable.
Ensure this light fitting is effectively earthed.
Insert the light fitting into the ceiling.
One piece front bezel
Insulation separator allowing loft insulation to be
placed over the fitting
Loop in / out terminal connector
Part B Fire Rated
Fixed Downlight - Satin Chrome
IP65 Shower Fixed Downlight – White
IP65 Shower Fixed Downlight – Chrome
IP65 Shower Fixed Downlight – Satin Chrome
GU10 LED 240V
Aluminium Reflector, heat forward
lamp only
Depandant on lamp fitted – check
Catalogue N°.
Dimmable lamps need a
compatible dimmer
Rated for 40W 240V aluminised heat
reflector lamps
Electrical
Classification
Class I, this fitting must be earthed
30, 60 & 90 minute protection
FIRE RATED DOWNLIGHTS
To be read in full before installation
and kept for future reference
Instruction leaflet
Range and Cut Out Dimensions
# identifies lamp colour temperature, 3 = 2800k lamp, 4 = 4000K lamp
Specification