Desa VUL18NR, VUL24NR, VUL18PR, VUL36NR, VUL24PR Owner's Operation And Installation Manual

...
UNVENTED (VENT-FREE) GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Remote-Ready Models VUL18/24/30/36(N,P)R
Thermostatically-Controlled Models VUL18/24/30/36(N,P)T
Remote-Ready Models Also Design-Certied As Vented Decorative Appliances
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com
TAbLE OF CONTENTS
Safety .................................................................. 2
Unpacking............................................................ 5
Product Identication ........................................... 5
Local Codes......................................................... 5
Optional Remote Control Accessories ................. 5
Air For Combustion and Ventilation ..................... 6
Product Features ................................................. 6
Installation ........................................................... 9
Operation ........................................................... 20
Inspecting Burners............................................. 26
Cleaning and Maintenance ................................ 27

SAFETy

Wiring Diagram .................................................. 28
Troubleshooting ................................................. 29
Optional Positioning of
Thermostat Sensing Bulb ............................. 33
Specications .................................................... 33
Parts .................................................................. 34
Service Hints ..................................................... 40
Technical Service............................................... 40
Replacement Parts ............................................ 40
Accessories ....................................................... 40
Warranty .............................................. Back Cover
WARNING: Improper
installation, adjustment,
alte ration , serv ice or maintenance can cause
injury or property dam­age. Refer to this manual
for correct installation
and operational proce­dures. For assistance or
additional information
consult a qualified in­staller, service agency or the gas supplier.
WARNING: This ap-
pliance is for installation only in a solid-fuel burning
masonry or UL127 fac-
tory-built replace or in a listed ventless rebox en­closure. It is design-certi­ed for these installations
in accordance with ANSI
Z21.11.2. Exception: Do not install this appliance in a factory-built replace
that includes instructions
stating it has not been test­ed or should not be used with unvented gas logs.
WARNING: This is an
unvented gas-red heat­er. It uses air (oxygen)
from the room in which
it is installed. Provisions for adequate combustion
and ventilation air must
be provided. Refer to Air for Combustion and Ven­tilation section on page 6
of this manual.
This appliance may be in-
stalled in an aftermarket,*
per man ent ly l oca ted , manufactured (mobile) home, where not prohib­ited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
www.desatech.com
122001-01C2
SAFETy
Continued
WARNING: This product con-
tains and/or generates chemicals
known to the state of California
to cause cancer or birth defects or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op­erate or service this replace. Improper use of this replace can cause serious injury or death from burns, re, explo­sion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be
working properly. Get fresh air at once! Have replace serviced. Some people are more af­fected by carbon monoxide than others. These
include pregnant women, people with heart or lung disease or anemia, those under the inu-
ence of alcohol and those at high altitudes. Natural and Propane/LP gases are odorless.
An odor-making agent is added to these gases.
The odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of
this replace.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not use a
blower insert, heat exchanger insert or other accessory not ap­proved for use with this heater.
WARNING: Do not allow fans
to blow directly into the replace. Avoid any drafts that alter burner ame patterns. Ceiling fans can create drafts that alter burner ame patterns. Altered burner patterns can cause sooting.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the heater.
Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater
will remain hot for a time after
shutdown. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with heater. When using the hand-
held remote accessory (Remote-
Ready Models Only), keep selec­tor switch in the OFF position to prevent children from turning on burners with remote.
You must operate this heater with the replace screen and hood in place. Make sure re­place screen and hood are in place before running heater.
Keep the appliance area clear and free from combustible ma­terials, gasoline and other am­mable vapors and liquids.
122001-01C 3
www.desatech.com
SAFETy
Continued
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor ’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier,
call the re department
4. This heater shall not be installed in a bed-
room or bathroom, unless installed as a
vented appliance. See Installing Damper Clamp Accessory for Vented Operation,
page 12 (Remote-Ready Models Only). This gas log set may not be installed as a vented appliance in a bedroom or bathroom in the Commonwealth of Massachusetts.
5. Before installing in a solid fuel burning re­place, the chimney ue and rebox must be cleaned of soot, creosote, ashes and loose paint by a qualied chimney cleaner.
Creosote will ignite if highly heated. A dirty
chimney ue may create and distribute
soot within the house. Inspect chimney
ue for damage. If damaged, repair ue and rebox before operating heater.
6. Do not burn solid-fuel in a masonry or
UL127 factory-built replace in which a
vent-free room heater is installed.
7. If replace has glass doors, never operate
this heater with glass doors closed. If you
operate heater with doors closed, heat buildup inside replace will cause glass to
burst. Make sure there are no obstructions
across openings of replace.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance, page 27.
9. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may
create a white powder residue within burner box or on adjacent walls and furniture.
10. This heater needs fresh, outside air ven­tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air for Combustion and Ventilation,
page 6. If heater keeps shutting off, see Troubleshooting, page 29.
11. Do not run heater
• where ammable liquids or vapors are
used or stored
• under dusty conditions
12. Do not use this heater to cook food or burn paper or other objects.
13. Do not use heater if any part has been ex­posed to or under water. Immediately call
a qualied service technician to inspect
the room heater and to replace any part of the control system and any gas control which has been under water.
14. Do not operate heater if any log is broken. Do not operate heater if a log is chipped
(dime-sized or larger).
15. Turn heater off and let cool before ser-
vicing, installing or repairing. Make sure
the selector switch is in the OFF position (Remote-Ready Models Only). Only a
qualied service person should install,
service or repair heater.
16. Make sure the selector switch is in the OFF position when you are away from home for long periods of time (Remote­Ready Models Only).
17. Remote-ready heaters must not be con­nected to any external electrical source.
18. Operating heater above elevations of
4,500 feet may cause pilot outage.
19. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).
20. Provide adequate clearances around air openings.
www.desatech.com
122001-01C4

UNPACkING

CAUTION: Do not remove the
data plates from the grate as­sembly. The data plates contain important warranty and safety information.
1. Remove logs and heater base assembly from carton.

PRODUCT IDENTIFICATION

Note: Do not pick up heater base assem-
bly by burners. This could damage heater. Always handle base assembly by grate.
2. Remove all protective packaging applied to logs and heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged call DESA Heating, LLC
at 1-866-672-6040 for replacement parts before returning to dealer.
Log Set
Ignitor
Remote Control (Optional)
Control Knob
Flame Adjustment Knob
Figure 1 - Product Identication

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Rear Burner
Base Assembly
State of Massachusetts: The installa­tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

OPTIONAL REMOTE CONTROL ACCESSORIES

There are four optional remote controls that can be purchased separately for Remote­Ready Models Only:
• wall switch
hand-held ON/OFF remote
wall thermostat
• hand-held thermostat remote
122001-01C 5
www.desatech.com
See Accessories, page 40. The wall thermostat or hand-held thermostat
may not be used where vented decorative listing is required.

PRODUCT FEATURES

OPERATION
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by
both realistic ames and glowing coals. This
heater is designed for vent-free operation with ue damper closed. It has been tested and ap­proved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative
(ANSI Z21.60) product by opening the ue
damper (Non-Thermostat Models Only).

AIR FOR COMbUSTION AND VENTILATION

WARNING: This heater shall
not be installed in a room or space unless the required vol­ume of indoor combustion air is provided by the method de­scribed in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or
applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation
and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
During heating months, home owners want
their homes as airtight as possible. While it is good to make your home energy
efcient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation.
Exhaust fans, replaces, clothes dryers and
fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
www.desatech.com
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
ELECTRONIC IGNITION SYSTEM
This heater has an electronic ignitor to light heater fuel supply.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space
The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion
and ventilation. However, in buildings of un­usually tight construction, you must provide
additional fresh air.
Unusually tight construction is dened as
construction where:
a. walls and ceilings exposed to the out-
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10 less with openings gasketed or sealed
and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between sole plates and oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.
-11
kg per pa-sec-m2) or
122001-01C6
AIR FOR COMbUSTION AND VENTILATION
Continued
If your home meets all of the three criteria
above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the
three criteria above, proceed to Determin- ing Fresh-Air Flow For Heater Location, below.
Conned and Unconned Space
The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 denes a conned space as a space
whose volume is less than 50 cubic feet per
1,000 Btu/hr (4.8 m3 per kw) of the aggregate
input rating of all appliances installed in that
space and an unconned space as a space
whose volume is not less than 50 cubic feet
per 1,000 Btu/hr (4.8 m3 per kw) of the ag-
gregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are
installed*, through openings not furnished with doors, are considered a part of the un­conned space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Conned or Unconned Space
Use this work sheet to determine if you have
a conned or unconned space.
Space: Includes the room in which you will install
replace plus any adjoining rooms with door­less passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room
is supplied with grills or openings, add the
volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20
= 51,200 (maximum Btu/Hr the space can
support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free replace __________ Btu/Hr Gas water heater* __________ Btu/Hr Gas furnace __________ Btu/Hr Vented gas heater __________ Btu/Hr Gas replace logs __________ Btu/Hr Other gas appliances* + _________Btu/Hr Total = _________Btu/Hr * Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example: Gas water heater __________ Btu/Hr Vent-free replace + _________Btu/Hr Total = _________Btu/Hr
4.
Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_______ Btu/Hr (maximum can support) _______ Btu/Hr (actual amount used) Example: 51,200 Btu/Hr (maximum the
73,000 Btu/Hr (actual amount of
The space in the above example is a conned
space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can sup­port. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconned space, remove door to adjoin­ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 8.
B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors, page 8.
C. Install a lower Btu/Hr replace, if lower Btu/Hr
size makes room unconned.
If the actual Btu/Hr used is less than the maxi-
mum Btu/Hr the space can support, the space is an unconned space. You will need no additional
fresh air ventilation.
space can support)
Btu/Hr used)
40,000 33,000 73,000
122001-01C 7
www.desatech.com
AIR FOR COMbUSTION AND VENTILATION
Outlet Air
Ve ntilated Attic
Outlet A
ir
Inlet Air
Inlet Air
Ve ntilated
Crawl Space
T o
Crawl
Space
T o Attic
Or
Remove Door into Adjoining
Room, Option
3
Ve ntilation Grills
Into Adjoining Room,
Option 2
Ve ntilation
Grills Into Adjoining
Room,
Option 1
12"
12"
Continued
WARNING: If the area in which
the heater may be operated does
not meet the required volume for
indoor combustion air, combus-
tion and ventilation air shall be
provided by one of the methods
described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54,
the International Fuel Gas Code,
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining
unconned space. When ventilating to an adjoining unconned space, you must provide
two permanent openings: one within 12" of the
ceiling and one within 12" of the oor on the
wall connecting the two spaces (see options
1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation
grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma­nent openings: one within 12" of the ceiling
and one within 12" of the oor. Connect these
items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size
of ventilation grills or ducts. IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo­stat-controlled power vent. Heated air entering the attic will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
Figure 2 - Ventilation Air from Inside Building
www.desatech.com
122001-01C8

INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualied ser-
vice person must install heater.
Follow all local codes.
NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented conguration.
Check your state or local codes.
WARNING: Make sure the
selector switch is in the OFF
position before installing heater
(Remote-Ready Models Only).
WARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creo­sote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney ue may create and distribute soot within the house. Inspect chimney and rebox ue for damage. If dam­aged, repair ue and rebox before operating heater.
WARNING: Seal any fresh
air vents or ash clean-out doors
located on oor or wall of re­place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney ue damper.
WARNING: Never install the
heater
• in a bedroom or bathroom
unless installed as a vented appliance, see page 12 (Re­mote-Ready Models Only)
• in a recreational vehicle
• where curtains, furniture, clothing or other ammable objects are less than 36" from the front and 42" from top
heater, For side clearances
see Figure 4 page 10
• in high trafc areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning u­ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is benecial, installing
heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventila-
tion, page 6.
122001-01C 9
www.desatech.com
INSTALLATION
Continued
CHECK GAS TYPE
Use the correct type of gas (natural or propane/ LP). If your gas supply is not the correct gas
type, do not install heater. Call dealer where
you bought heater for proper type heater.
WARNING: This appliance is equipped for either natural gas or propane/LP gas but not both. Gas type is indicated on the rat­ing plate. Field conversion is not permitted.
INSTALLATION AND CLEARANCES FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you can, provide greater clearances from oor, ceiling and adjoining wall.
Minimum Fireplace Clearance to
Combustible Materials
Side Wall 16", Ceiling 42", Floor 5",
Front 36"
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and protrudes 3 1/2" from the wall. This com­bustible material must be 4" from the side
of the replace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured rebox, follow rebox
manufacturer’s instructions for minimum clearances to combustible materials.
B. Clearances from the top of the replace
opening to the ceiling should not be less than 42".
NOTICE: Manual control heaters
may be used as a vented product.
If so, you must always run heater
with chimney ue damper open. If running heater with damper open, noncombustible material above replace opening is not needed. Go to Installing Damper
Clamp Accessory for Vented Operation, page 12.
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Log
Height Depth
Size
18" 17" 14" 20" 14" 24" 17" 14" 26" 18" 30" 21" 14" 32" 22" 36" 21" 14" 38" 27 1/2"
*Measured at 14" depth
Carefully follow these instructions. This will
ens ur e safe inst al lation into a masonry, UL127-listed manufactured replace or listed vent-free rebox.
Minimum Clearances For Side
Combustible Material, Side Wall and Ceiling
A. Clearances from the side of the replace
cabinet to any combustible material and wall should follow diagram in Figure 4.
Front
Width
Rear
Width*
www.desatech.com
Example
*
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
Combustible to Wall
122001-01C10
INSTALLATION
Heat Resistant Material
(A)
Minimum Noncombustible Material
Minimum Noncombustible Material Height
Distances to Underside of Mantel
Top of Fireplace Opening
Underside of Mantel Shelf
12"
8"
(A)
18"
14"
20"
17"
22"
19"
24"
20"
All minimum distances are in inches
Log Set 24"/30"/36" Models 18" Model
2 1/2"
6"
8"
10"
Mantel Shelf
Continued
MINIMUM NONCOMbUSTIbLE MATERIAL CLEARANCES
If Not Using Mantel
Note: If using a mantel proceed to If Using Mantel. If not using a mantel, follow the infor­mation on this page.
You must have noncombustible material(s)
above the replace opening. Noncombus­tible materials (such as slate, marble, tile,
etc.) must be at least 1/2" thick. With sheet metal, you must have noncombustible ma­terial behind it. Noncombustible material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you must install the replace hood accessory
(24" and 30" Models Only). See Figure 5 for minimum clearances.
Noncombustible
Material
Distance (A)
1
2" or more Noncombustible mate-
Between 8" and 12"
Less than 8"
Requirements for Safe
Installation
rial OK.
24", 30" or 36" Models: Install replace hood accessory (GA6050,
GA6052 or GA6053 see
Accessories, page 40).
18" Model: Noncom­bustible material OK. Noncombustible mate­rial must be extended to at least 8". See
Between 8" and 12",
above. If you cannot ex-
tend material, you must operate heater with ue
damper open.
If Using Mantel
You must have noncombustible material(s)
above the replace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal,
you must have noncombustible material be­hind it. Noncombustible material must extend at least 8" up (for all models). If noncombus-
tible material is less than 12", you must install the replace hood accessory (24" and 30"
Models Only). Even if noncombustible mate-
rial is more than 12", you may need the hood accessory to deect heat away from your
mantel shelf. See Figures 5 and 6 and Figure
7, page 9, for minimum clearances.
IMPORTANT: If you cannot meet these mini-
mum clearances, you must operate heater with chimney ue damper open. Go to Install-
ing Damper Clamp Accessory for Vented Operation, page 12.
MANTEL CLEARANCES
In addition to meeting noncombustible mate-
rial clearances, you must also meet required clearances between replace opening and
mantel shelf. If you do not meet the clearances
listed below, you will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between
mantel shelf and top of replace opening, a
hood is not required (see Figure 6).
Figure 5 - Heat Resistant Material (Slate,
122001-01C 11
www.desatech.com
Marble, Tile, etc.) Above Fireplace
Figure 6 - Minimum Mantel Clearances
Without Using Hood
14" Min.
Combustible Material
Noncombustible Material
Hearth
5" Min.
Combustible Material
Minimum Noncombustible Material
8" Min.
12" 15" 18"
All minimum distances are in inches
Log Sets 18", 24", 30" & 36" Models
20"
2
1
/2
"
6"
8"
10"
12"
Distances to Underside of Mantel
Hood (GA6050, GA6052, or GA6053)
Top of Fireplace Opening
Underside of Mantel Shelf
Mantel Shelf
INSTALLATION
Continued
Determining Minimum Mantel Clearance When Using a Hood
If minimum clearances in Figure 6, page 11, are not met, you must have a hood. When using
a hood there are still certain minimum mantel clearances required. Follow minimum clear-
ances shown in Figure 7, when using hood.
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all
minimum clearances shown in
this manual.
NOTICE: If your installation does not meet the minimum clear­ances shown, you must do one
of the following:
• operate the logs only with the
ue damper open
• raise the mantel to an accept-
able height
• remove the mantel
Figure 7 - Minimum Mantel Clearances
When Using Hood
www.desatech.com
FLOOR CLEARANCES
A. If installing appliance on the oor level,
you must maintain the minimum distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the replace, you must install appliance at least 5" above the combustible ooring
(see Figure 9).
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION
Note: When used as a vented heater, ap­pliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.
For Massachusetts Residents Only: Instal­lation of this gas log set as a vented appliance in the Commonwealth of Massachusetts re­quires the damper be permanently removed or welded in the fully open position.
If your heater is a manually-controlled model,
you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.
1. The replace does not meet the clearance
to combustibles requirements for vent­free operation.
122001-01C12
INSTALLATION
Continued
2. State or local codes do not permit vent­free operation.
3. You prefer vented operation.
If reasons number 1 or 2 apply to you, you must permanently open chimney ue damper.
You must install the damper clamp accessory
(to order, see Accessories, page 40). This
will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
See chart below for minimum permanent ue
opening you must provide. Attach damper clamp so the minimum permanent ue open­ing will be maintained at all times.
Area of Various Standard Round Flues
Diameter Area
5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches
Chimney Height
6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
Damper Clamp
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
122001-01C 13
Minimum Permanent
Flue Opening
Damper
Damper Clamp
Damper
Manufactured Fireplace
www.desatech.com
INSTALLING HEATER bASE ASSEMbLY
WARNING: You must secure
this heater to replace oor. If
not, heater will move when you
adjust controls. Moving heater may cause a gas leak.
WARNING: If installing in a sunken replace, special care is needed. You must raise the replace oor to allow access to heater control panel. This will insure adequate air ow and guard against sooting and controls being damaged. Raise replace oor with noncombus­tible material. Make sure material is secure.
CAUTION: Do not pick up heater base assembly by burn­ers. This could damage heater. Only handle base assembly by grates.
IMPORTANT: Make sure the heater burners
are level. If heater is not level, heater will not work properly. For thermostat models, avoid
damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until
ready to mount base to oor. See Optional Positioning Of Thermostat Sensing Bulb,
page 33.
Installation Items Needed
• hardware package (provided with heater)
• approved exible gas hose and ttings (not
provided) (if allowed by local codes)
• sealant (resistant to propane/LP gas, not
provided)
• electric drill with 3/16” masonry drill bit
Note: Install optional Receiver and Hand-Held Remote Control Kit (see Accessories, page
40) before installing gas log heater (Remote­Ready Models Only). See installation instruc­tions included with the kit.
INSTALLATION
Continued
1. Apply pipe joint sealant lightly to male threads of gas fitting (provided). For Thermostatically-Controlled Models con-
nect approved exible gas hose to gas
regulator of heater (see Figure 11). For Remote-Ready models connect approved exible gas hose to inlet side of gas con­trol (see Figure 12).
IMPORTANT: Hold gas regulator with
wrench when connecting flexible gas hose (Thermostatically-Controlled Models Only).
2. Po s i t i o n he a t e r base as s e m b l y in fireplace.
3. Mark screw locations through holes in front panel of base (see Figure 13). If
installing in a brick-bottom replace, mark
screw locations in mortar joint of bricks.
4. Remove heater base from replace.
5. Drill holes at marked locations using 3/16" drill bit.
6. Attach base, through holes in front panel of base, to replace oor using masonry
screws provided in hardware package (see Figure 13).
7. Connect to gas supply. See Connecting To Gas Supply.
Heater Gas Regulator
Flexible Gas Hose (if allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose to
Heater Gas Regulator (Thermostatically-
Controlled Models Only)
Gas Control
Masonry
Screw
Figure 13 - Attaching Base to Fireplace
Floor (Remote-Ready Models Only)
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualied ser­vice person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect
propane/LP replace directly to the propane/LP supply. This heater requires an external regu­lator (not supplied). Install the external regulator between the heater and propane/LP supply.
Flexible Gas Hose (if allowed by local codes)
Figure 12 - Attaching Flexible Gas Hose
to Heater Gas Regulator
(Remote-Ready Models Only)
www.desatech.com
WARNING: Never connect
natural gas replace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
122001-01C14