Desa FVSA24M, VSLR18, VVDA18M, FVDA30M, VDLCR18, VSLR24, FVDA18M, VVDA30M, VDLCR24, VVSA24M, VVSA18M, VDLCR30, VVDA24M, FVSA18M, FVDA24M User Manual
TM
GAS LOG VENTED
DECORATIVE APPLIANCE
OWNER’S OPERATION AND
INSTALLATION MANUAL
Convertible from Natural Gas
to Propane/LP Gas
ANSI Z21.60a-2000
CSA 2.26a-2000
APPROVED
VANGUARD MODELS:
VVSA18M, VVSA24M, VVDA18M, VVDA24M and VVDA30M
FOR USE WITH LOG SETS:
Hanover Round Oak Log Models VSLR18 and VSLR24
Kingston Split Oak Log Models VDLCR18, VDLCR24 (Shown)
and VDLCR30
FMI MODELS:
FVSA18M, FVSA24M, FVDA18M, FVDA24M and FVDA30M
FOR USE WITH LOG SETS:
Arlington Round Oak Log Models FSLR18 and FSLR24
Manchester Split Oak Log Models FDLCR18, FDLCR24 and
FDLCR30
COMFORT GLOW MODELS:
Oxford Oak Log Models CVSA18M and CVSA24M
Berkshire Oak Log Models CVDA18M, CVDA24M and
CVDA30M
Amherst Oak Log Models CPVSA18M and CPVSA24M
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assistance or additional information
consult a qualified installer, service agency, or the gas supplier.
WARNING: This appliance is for
installation only in a solid-fuel
burning masonry or UL127 factorybuilt fireplace, constructed of noncombustible material, and connected to a working flue. (See page
4 for minimum flue opening.)
WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to the
National
Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
Save this manual for future reference.
Save this manual for future reference.
TABLE OF CONTENTS
SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
LOCAL CODES........................................................................... 3
WARNING: This product contains chemicals
known to the State of California to cause cancer or
birth defects, or other reproductive harm.
WARNING: Keep flue open when operating unit.
IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or service this log set. Improper use of this log set can cause
serious injury or death from burns, fire, explosion,
electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the log set may not be working properly. Getfresh air at once! Have log set serviced. Some people are more
affected by carbon monoxide than others. These include pregnant
women, people with heart or lung disease or anemia, those under the
influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is
added to the gas. The odor helps you detect a gas leak. However, the
odor added to the gas can fade. Gas may be present even though no
odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this log set.
WARNING: Any change to this log set or its
controls can be dangerous.
CLEANING AND MAINTENANCE ............................................ 10
OWNER'S REGISTRATION FORM .......................................... 27
WARRANTY INFORMATION ...................................... Back Cover
1.This appliance, as supplied, is only for use with the type of gas
indicated on the rating plate. This appliance is convertible for
use with propane/LP.
2.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in
your building
• immediately call your gas supplier from a neighbor’ s phone.
Follow the gas supplier’s instructions
• if you cannot reach your gas supplier , call the fire department
3.Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable ob-
jects are less than 42 inches from the front, top, or sides of
the log set
• in high traffic areas
• in windy or drafty areas
4.Before installing in a solid fuel burning fireplace, the chimney
flue and firebox must be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.
5.Y ou must operate this log set with fireplace doors or screens in
place and fully closed. Unless provided by other means, fireplace doors or screens shall have openings for introduction of
combustion air.
6.This log set is designed to be smokeless. If logs ever appear to
smoke, turn off appliance and call a qualified service person.
Note:
During initial operation, slight smoking could occur due
to log curing and the burning of manufacturing residues. You
may wish to add more ventilation by opening a window.
7.To reduce the creation of soot, follow the instructions in Clean-ing and Maintenance, page 10.
8.Do not allow fans to blow directly into the fireplace. Avoid
any drafts that alter burner flame patterns. Ceiling fans can
create drafts that alter burner flame patterns. Altered burner
patterns can increase sooting.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
SAFETY INFORMATION
LOCAL CODES
PRODUCT IDENTIFICATION
UNPACKING
PRODUCT FEATURE
3
3
SAFETY INFORMATION
Continued
9.Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this log set.
10. The installation and provisions for combustion and ventilation
air must conform with the National Fuel Gas Codes, ANSI Z233.1/
NFPA 54, Section 5.3, Air for Combustion and Ventilation.
11. Do not run log set
• where flammable liquids or vapors are used or stored
• under dusty conditions
12. Do not burn solid fuel in the fireplace after installing the log
set. Do not use this log set to cook food or burn paper or other
objects.
13. Log set becomes very hot when in use. Keep children and adults
away from hot surface to avoid burns or clothing ignition. Log
set will remain hot for a time after shutdown. Allow surface to
cool before touching.
14. Carefully supervise young children when they are in the room
with log set.
15. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
16. To help prevent breakage, new logs must be broken-in (see
Curing Logs page 9).
17. Turn log set off and let cool before servicing, installing, or
repairing. Only a qualified service person should install, service, or repair log set.
18. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
19. Provide adequate clearances around air openings.
LOCAL CODES
Install and use log set with care. Follow all local codes. In the absence
of local codes, use the latest edition of The National Fuel Gas CodeANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT IDENTIFICATION
Grate Steps
Grate
Burner
Pan
Figure 1 - Product Identification (VVDA24 Shown)
Burner
Clamp
Burner
Manifold
Hearth Kit Model ________________________
Serial Number __________________________
Log Set Model __________________________
UNPACKING
CAUTION: Do not remove the metal data plates
from the burner pan. The data plates contain important warranty and safety information.
1.Remove logs, hearth kit, pan materials, and hardware from
carton.
2.Remove all protective packaging applied to logs and base for
shipment.
3.Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought the product.
PRODUCT FEATURE
ON/OFF SAFETY VALVE/PILOT
Unit is tested and approved to ANSI Z21.60a-2000 and CSA 2.26a2000 as a vented decorative appliance. It is supplied with the parts and
instructions to convert to propane/LP gas use.
901268-01D
For more information, visit www.desatech.com
For more information, visit www.desatech.com
INSTALLATION
4
Flue Opening Specifications
Check Gas Type
Venting Specifications for Installation
INSTALLATION
WARNING: The Massachusetts State Board requires all installations be performed by a Licensed
Plumber or Gas Fitter. Massachusetts state code requires all vent dampers be welded open or removed.
CAUTION: Do not remove the data plates attached
to the burner pan. The data plates contain important
warranty and safety information.
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue may create and
distribute soot within the house. Inspect chimney
flue for damage.
NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced
with this type of gas appliance. Only factory authorized components listed in these instructions may be
used in accordance with the manufacturer’s instructions and all codes and requirements of the authority
having jurisdiction. Any modifications to this kit, or
use of unauthorized components or accessory items
will void the manufacturer’s warranty, and may result
in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note:
This vented appliance must be installed only in a solid-fuel
burning fireplace with a working flue and constructed of noncombustible material.
The charts in Figure 2 indicate technical information regarding the
installation of your gas log set. Please make sure that all of the
specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with
the minimum openings shown in the Figure 2.
Btu Input
Natural
DESCRIPTION
18" Single Burner50,00040,000.11632.08146
24" Single Burner60,00050,000.12031.08245
18" Dual Burner55,00045,000.11632.08245
24" Dual Burner65,00055,000.13829.08644
30" Dual Burner70,00060,000.1405 28.08943
Gas
Btu Input
Propane/LP
Gas
Burner Orifice
Natural
In.Num. In.Num.
Propane/LP
MINIMUM FIREBOX SIZES
LOG FRONT BACKMINIMUM
SIZE WIDTH WIDTH* DEPTH HEIGHT FLUE SIZE
Use only natural gas. If your gas supply is not natural gas, you must
convert the appliance to propane/LP. Follow the instructions on
pages 6 and 7.
If the fireplace does not have a gas supply shut-off valve, one must
be installed.
VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be drafting properly. To
check the vent for proper drafting: Light a tightly rolled newspaper
on one end and place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room, extinguish the flame
and remove any obstruction until proper venting is achieved.
The chimney flue damper must be fixed open to provide a minimum
of 81 sq. in. of free air opening during operation of this log set. A
multipurpose damper clamp is provided to fix the damper in position.
The minimum flue sizes shown in Figure 2 are based on a 6' chimney
height using round pipe. Your minimum flue size will vary based on
input rate and chimney height. Refer to the National Fuel Gas CodeANSI Z223.1/NFPA 54, Section 6.6, for details.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
INSTALLATION
Continued
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to the leading edge of the
damper as shown in Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp or permanent stop
must be installed, or the damper blade must be cut or removed.
Damper Clamp
Damper
Damper
INSTALLATION
Installing Damper Clamp
5
5
Installation must include an equipment shutoff valve with "T" style
handle, gas union and, for propane/LP gas only, a plugged 1/8" NPT
tap. Locate NPT tap within reach for test gauge hook up. NPT tap
must be upstream from log set (see Figure 4).
IMPORTANT:
Install equipment shutoff valve in an accessible
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in a clogged burner injector.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
Masonry Fireplace
Damper
Clamp
Figure 3 - Attaching Damper Clamp
Manufactured
Fireplace
Damper
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must con-
nect log set to gas supply. Follow all local codes.
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
We recommend that you install sediment trap in supply line as
shown in Figure 4. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into log set controls. If sediment trap is not installed or
is installed wrong, log set may not run properly.
Approved Flexible Gas Hose (no longer
than 36" if required by local codes)
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*
From Gas Meter
3" Minimum
Cap
Figure 4 - Gas Connection
Pipe Nipple
Sediment Trap
(5" W.C.** to
10.5" W.C.
Pressure)
Tee Joint
* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 26.
** Minimum inlet pressure for purpose of input adjustment.
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to log set. If
pipe is too small, undue loss of volume will occur.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
INSTALLATION
6
Checking Gas Connections
Hearth Pan Installation
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct all leaks
at once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1.Disconnect log set and its individual equipment shutoff valve
from gas supply piping system.
2.Cap off open end of gas pipe where equipment shutoff valve
was connected.
3.Pressurize supply piping system by either using compressed
air or opening main gas valve located on or near gas meter.
4.Check all joints of gas supply piping system. Apply a noncorrosive
leak detection fluid to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Reconnect log set and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 5).
2.Pressurize supply piping system by either using compressed
air or opening main gas valve located on or near gas meter.
3.Check all joints from gas meter to equipment shutoff valve
(see Figure 5). Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.
4.Correct all leaks at once.
Equipment Shutoff Valve
Gas Meter
HEARTH PAN INSTALLATION
If using propane/LP gas, see Propane/LP Gas Conversion before
installing hearth pan.
1.Place the burner pan assembly in the center of the fireplace
floor. Make sure the front of pan faces forward.
2.Thread the gas supply fitting to the fireplace gas supply pipe.
Adjust to most convenient position.
3.Install the gas connector tube to the gas supply fitting. Carefully
shape tube to attach to inlet fitting. Be careful not to cause
kinks in tube.
4.Test for leaks following instructions under Testing Burner forLeaks, page 8.
5.Retighten and adjust the location of the gas control as necessary.
The gas control should be level, with the control rod to the front.
Gas Control
Valve
Regulator
Gas Connector Tube
Figure 6 - Installing Inlet Fitting and Gas Connector Tube (Valve
Cover Removed for Clarity)
Propane/LP Gas Conversion
To convert to propane/LP gas, the burner inlet fitting and pilot
orifice must be replaced and the regulator pressure must be reset.
The propane/LP burner inlet fitting is supplied with the orifice
installed. The propane/LP pilot orifice for converting the pilot is
supplied and is marked with a red stripe.
1.Remove control rod extension and piezo ignitor by pulling gently.
2.Remove screws that attach pilot assembly to valve cover and
valve cover to burner pan (see Figure 7, page 7).
3.Remove valve cover.
Figure 5 - Checking Gas Joints
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
INSTALLATION
Continued
INSTALLATION
Hearth Pan Installation (Cont.)
7
7
4.Using a wrench, remove gas control valve and burner inlet
fitting by turning counterclockwise (see Figure 8).
5.Remove the burner inlet fitting from the gas control assembly
(see Figure 8). DO NOT remove the orifice from this fitting.
The propane/LP burner inlet fitting is included in the hardware kit (see Figure 9).
6.Be sure to use the correct orifice for your appliance. The orifice kit included with this appliance contains an orifice installed
in an air mixer fitting.
7.Using thread sealant (resistant to the action of propane/LP gas) on
smaller end of fitting, screw the burner inlet fitting into the outlet
side of the gas control (see Figure 8). Tighten using a wrench.
8.Thread gas control valve and burner inlet fitting into burner
manifold (see Figure 8). Use thread sealant on male threads of
burner inlet fitting. Secure with a wrench. Make sure control
rod is facing the front (see Figure 8).
Screw
Control
Knob
Control Rod
Extension
Figure 7 - Removing/Installing Cover, Control Knob, and
Piezo Ignitor
Valve Cover
Piezo Ignitor
Thermocouple
Pilot
Ignitor
9.To adjust regulator pressure, remove the brass hex plug from
regulator (see Figure 10).
10. Remove the plastic pressure button from the brass plug (see
Figure 10).
11. Reverse the plastic pressure button and replace it into the brass
plug (see Figure 10).
12. Replace brass plug into regulator.
13. Using two screws removed in step 2, page 6, replace valve cover.
14. Gently loosen and remove the pilot line connection from the
pilot bracket (see Figure 11).
15. Replace injector with propane/LP injector with red stripe.
16. Replace and tighten pilot line to bracket.
17. Using screws removed in step 2, page 6, reattach pilot bracket
to valve cover.
18. Continue with step 1 under Hearth Pan Installation, page 6.
Regulator
Plastic Pressure
Button Positioned
for Natural Gas
Figure 10 - Adjusting Regulator Pressure for Conversion
Reversed Plastic
Pressure Button
for Propane/LP
Conversion
Brass Plug
Burner Inlet
Fitting for
Natural Gas
Control Rod
Figure 8- Remove Burner Inlet Fitting
Injector for
Natural Gas
NATURAL
GAS FITTING
Figure 9 - Burner Inlet Fittings with Injectors
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
PROPANE/LP
GAS FITTING
Control
Valve
Injector for
Propane/LP
Gas
Pilot Bracket
Pilot Injector
Pilot Adjustment Screw
Figure 11 - Installing Propane/LP Pilot Orifice
INSTALLATION
8
Testing Burner for Leaks
Adding Pan Material
Installing the Grate and Logs
INSTALLATION
Continued
TESTING BURNER FOR LEAKS
1. Generously apply noncorrosive leak detection fluid to all
connections.
WARNING: Never check for gas leaks with open
flame.
2.Light the burner with the shutoff valve no more than half open
and holding a match slightly in front of the pan (see LightingInstructions, page 9).
3.Inspect all connections for bubbles, raw gas odor, or flame
from any area other than the burner (leaks). If leaks are detected, shut off the gas valve immediately. Tighten, or reassemble the loose connection(s) using pipe joint compound until
burner system is leak free.
4.When the burner is tested and leak free, observe the individual
tongues of flame on the burner.
cludes more ports on the outside of the bar. Make sure that all
ports are clear and producing flame evenly across the burner.
If any ports appear blocked, clear them by removing the burner
manifold and reaming the ports with a modified paper clip or
other suitable tool.
5.When finished testing, turn the gas shutoff valve OFF to extinguish all flames.
Note:
The burner design in-
Grate
Figure 12 - Installing Grate (Pan Material Not Shown)
Grate Steps
ADDING PAN MATERIAL
1.Open the bag of ash bed material (vermiculite) and spread it evenly
across the burner pan to the top. You may overflow the front and
sides of the pan to cover the entire pan. Do not cover valve or
inlet fitting.
2.Open the glowing embers and evenly cover the ash bed material (vermiculite) in the burner pan.
INSTALLING THE GRATE AND LOGS
1.Place the grate over the burner pan where the two outer horizontal supports on the grate fit into the two pan positioning
notches in the rear vertical edge of the pan.
2.Slide the two rear log grate steps over the two outer horizontal
supports on the grate as shown in Figure 12.
3.Place the back log on the grate onto the grate steps (see Figure 13).
4.Place the front log(s) on the grate and slide forward against
the front bars on the grate (see Figure 13).
5.Place the smaller top logs onto the bottom logs (see Figure 14).
Leave as much open space between logs as possible to minimize flame impingement and sooting.
they are handled roughly or if hit together while being placed.
Note:
Logs may chip if
Kingston Split Oak Logs
Figure 13 - Installing Front and Back Logs (Number and style of
your logs may vary)
Figure 14 - Placement of Top Logs (Kingston Split Oak Logs
Shown)
Hanover Round Oak Logs
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
OPERATING APPLIANCE
OPERATING APPLIANCE
For Your Safety Read Before Lighting
Curing Logs
Lighting Instructions
To Turn Off Gas To Appliance
9
9
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: Keep flue open when operating unit.
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
do not use any phone in
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information, column one.
2.Make sure equipment shutoff valve is fully open.
3.Press in and turn control knob clockwise
OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for
gas around log set and near floor. If you smell gas, STOP!
See Safety Informa tion, page 2. If you don’t smell gas, go to
the next step.
5. T ur n control knob counterclockwise
position and press in. Keep control knob pr essed in for f ive
(5) seconds.
Note:
You may be running this log set for the first time
after hooking up to gas supply . If so, the control knob may
need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
• If contr ol knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
6.With control knob pressed in, push do wn and release ignitor button. This will light pilot. Visually locate the pilot on
the control valve cover by the edge of the burner pan to
look for flame. If needed, keep pressing ignitor b utton until pilot lights.
Note:
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service technician or gas supplier.
7.Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
8.Turn control knob counterclockwise to the ON
position. Burner should light. If burner does not light, call
a qualified service person.
to the
to the PILOT
CURING LOGS
During the 2-3 hour appliance break-in period, you may detect
an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a
normal and temporary situation that is not cause for alarm.
However, you may want to provide extra ventilation to the room
during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1 hour.
• Burn the logs in consecutive 1 hour periods raising the flame
an additional 2" to full flame height for a total of three hours.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901268-01D
Control Knob
Ignitor
On
ONOFF
Figure 15 - Ignitor and Control Knob
Pilot
Burner
Figure 16 - Thermocouple and Pilot
Pilot
ON
OFF
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
PULL PUSH
SLIGHT PUSH TO
PULL PUSH
TURN OFF
TURN OFF
PULL PUSH
SLIGHT PUSH TO
FROM "PILOT" POSITION
Thermocouple
Off
ON
FROM "PILOT" POSITION
OFF
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.