consult a qualified installer, service agency or
the gas supplier.
This appliance may be in-
stalled in an aftermarket,*
permanently located,
manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for
use with the type of gas
indicated on the rating
plate. This appliance is
not convertible for use
with other gases.
* Aftermarket: Completion of sale, not for
purpose of resale, from the manufacturer
WARNING: This product
con tains a nd/o r g ener ates
chemicals known to the state
of California to cause cancer or
birth defects or other reproductive harm.
IMPORTANT: Read this owner’s
manual carefully and completely
be fore trying to a ssemble,
operate or service this heater.
Improper use of this replace
can cause serious injury or
death from burns, re, explosion, electrical shock and carbon
monoxide poisoning.
WARNING: Any change to
this rebox or its controls can
be dangerous.
WARNING: Do not allow fans
to blow directly into the rebox.
Avoid any drafts that alter burner
ame patterns. Ceiling fans can
create drafts that alter burner
ame patterns. Altered burner
patterns can cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert
or other accessory not approved
for use with this rebox.
www.desatech.com
116208-01G2
SAFETy
Continued
Firebox front and screen become
very hot when running heater.
Keep children and adults away
from hot surface to avoid burns
or clothing ignition. Firebox
will remain hot for a time after
shutdown. Allow surface to cool
before touching.
Do not place clothing or other
ammable material on or near
the appliance. Never place any
objects in the rebox or on
logs.
Carefully supervise young chil-
dren when they are in the room
with rebox.
You must operate this replace
with the provided fireplace
screen, hood if provided, in
place. Make sure these parts
are in place and screens are
closed before running rebox.
The supplied hood may not be
replaced with a hood which may
be provided with a log heater.
LOCAL CODES
Install and use with care. Follow all local
codes. In the absence of local codes, use
the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Keep the replace area clear and
free from combustible materials,
gasoline and other ammable
vapors and liquids.
1. Do not use this rebox as a wood-burning
replace. Use only decorative unvented
room heaters (log sets).
2. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting.
3. Use only provided hood or appropriate
hood accessory. See Accessories on
page 15.
4. Vent-free gas log heaters installed in
these reboxes require fresh air ventilation to run properly. See Air for Combus-tion and Ventilation, page 7.
5. Do not run heater in rebox
• where ammable liquids or vapors are
used or stored
• under dusty conditions
6. Do not use heater in this rebox to cook
food or burn paper or other objects.
7. Turn installed heater off and let cool
before servicing rebox. Only a qualied
service person should service and repair
rebox.
8. Do not use the rebox if it has been under water due to the shock hazard that
could result with the blower accessary (if
installed) in place.
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
116208-01G3
www.desatech.com
PRODUCT FEATURES
OPERATION
This rebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum rebox requirements supplied
with log heater.) It requires no outside venting
or chimney making installation easy and in-
expensive. When used without blower, heater
installed in rebox requires no electricity mak-
ing it ideal for emergency backup heat.
LOCATINg FIREBOX
PLANNING
Plan where you will install the rebox. This will
save time and money later when you install
the rebox. Before installation, consider the
following:
1. Where rebox will be located: Allow for
wall and ceiling clearances (see Installa-
tion Clearances, page 10).
2. Everything needed to complete replace
installation.
REFRACTORY BRICK LINER
Your rebox may feature a concrete refractory
brick liner. As with all concrete liners, this liner
may develop slight cracks when exposed to
heat. These cracks will not affect performance
of replace or vent-free gas logs.
OUTSIDE AIR KIT ACCESSORY
An optional AK4 air kit provides additional out-
door air to improve burner efciency and reduce
build-up of condensation in the living space.
Follow instructions included with air kit.
3. These models CANNOT be installed in
a bedroom unless maximum Btu rating
of installed vent-free log set is less than
10,000 Btu/hr.
4. Proper air for combustion and ventilation
(page 7).
www.desatech.com
116208-01G4
3 9/16"
3
7
/16"
8
1
/8"
8
1
/8"
10
1
/2"
9
3
/4"
291/2"
2315/16"
39/16"
17
3
/8"
251/8"
29
1
/2"
34
7
/16"
36
3
/8"
Standoffs
221/2"
4"
321/4"
361/2"
1415/16"
65/16"
3
3
/8"
3
9
/16"
8
1
/8"
41/4"
31/2"
Built-In
Side
Nailing
Flanges
5/8"
32" MODELS
291/2"
23
15
/16"
251/8"
29
1
/2"
34
7
/16"
36
3
/8"
Standoffs
221/2"
4"
321/4"
361/2"
1415/16"
65/16"
3
3
/8"
815/16"
93/4"
121/4"
191/2"
1611/16"
19/16"
3
9
/16"
8
1
/8"
213/16"
85/8"
41/4"
31/2"
Built-InSideNailingFlanges
Square
Gas Line
Access
Holes
5/8"
Left Side
View with
Air Kit
Outside Air
Kit Location
(Optional)
PRODUCT SPECIFICATIONS
Firebox Top View
Top View
Right Side View
Back View
Front View
116208-01G5
Figure 1 - Firebox Dimensions (32" Models)
www.desatech.com
201/2"
(36" Models)
24
1
/8"
(42" Models)
29/16"
26" (36" Models)
29
1
/2" (42" Models)
35" (36" Models)
42" (42" Models)
Full Length Nailing Flanges, Top and Sides
8"
8"
8"
8"
2"
40
1
/
4
" (36" Models)
44
1
/
4
" (42" Models)
43"(36" Models)•50"(42" Models)
35" (36" Models)
42" (42" Models)
29
1
/16" (36" Models)
36
1
/8" (42" Models)
41
1
/8"(36" Models)•481/8"(42" Models)
5/8"
4"
293/8" (36" Models)
36
1
/2" (42" Models)
36" (36" Models)
40" (42" Models)
PRODUCT SPECIFICATIONS
13 11/16" (36" Models)
12
3
/8" (42" Models)
7 1/4" (36" Models)
9" (42" Models)
2 9/16"
10
1
/2"
(36" Models)
12
1
/2"
(42" Models)
1311/16" (36" Models)
15
9
/16" (42" Models)
2
9
/16"
3
13
/16"
26" (36" Models)
29
1
/2" (42" Models)
35" (36" Models)42" (42" Models)
Full Length Nailing Flanges, Top and Sides
8"
8"
8"
8"
2"
40
1
/
4
" (36" Models)
44
1
/
4
" (42" Models)
43"(36" Models)•50"(42" Models)
35" (36" Models)42" (42" Models)
29
1
/16" (36" Models)
36
1
/8" (42" Models)
24
15
/16" (36" Models)
26
7
/8" (42" Models)
9
9
/16"
(36" Models)
10
11
/16"
(42" Models)
21
1
/8" ( 36" Mod els)
23
1
/16" (4 2" Mode ls)
41
1
/8"(36" Models)•481/8"(42" Models)
5/8"
4"
293/8" (36" Models)36
1
/2" (42" Models)
36" (36" Models)
40" (42" Models)
Continued
36" AND 42" MODELS
Note: If only one dimension is shown, dimension is the same for both 36" and 42" models.
Left Side
View with
Air Kit
Outside Air
Kit Location
(Optional)
Firebox Top View
Top View
Right
Side
View
Front View
Figure 2 - Firebox Dimensions (36" and 42" Models)