WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or
property damage. Refer to
this manual for correct installation and operational
procedures. For assistance
or additional information
consult a qualified installer,
service agency, or the gas
supplier.
— Installation and service
must be performed by a
qualified installer, service
agency, or the gas supplier.
Save this manual for future reference.
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can
cause serious injury or death from
burns, fire, explosions, electrical
shock, and carbon monoxide
poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
This fireplace is a vented product. This
fireplace will not produce any gas leakage
into your home if properly installed. This
fireplace must be properly installed by a
qualified service person. The glass door
must be properly seated and sealed. If this
unit is not properly installed by a qualified
service person with glass door properly
seated and sealed, gas leakage can occur.
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning resemble
the flu, with headaches, dizziness, or nausea.
If you have these signs, the fireplace may not
have been installed properly. Get fresh airat once! Have fireplace inspected and serviced by a qualified service person. Some
people are more affected by carbon monoxide than others. These include pregnant
women, people with heart or lung disease or
anemia, those under the influence of alcohol,
and those at high altitudes.
Propane gas and natural gas are both odorless. An odor-making agent is added to each
of these gases. The odor helps you detect a
gas leak. However, the odor added to these
gases can fade. Gas may be present even
though no odor exists.
Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this fireplace.
WARNING: Any change to
this fireplace or its controls can
be dangerous.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit
is used.
2.For propane fireplace, do not place propane/LP supply tank(s) inside any
structure. Locate propane/LP supply
tank(s) outdoors. To prevent performance problems, do not use propane
fuel tank of less than 100 lbs. capacity .
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. F ollow the
gas supplier’s instructions
• if you cannot reach you gas supplier ,
call the fire department.
4.Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42" from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
5.This fireplace reaches high temperatures. Keep children and adults away
from hot surfaces to avoid b urns or clothing ignition. Fireplace will remain hot
for a time after shut-down. Allow surfaces to cool before touching.
6.Carefully supervise young children
when they are in the room with fireplace.
7.Do not modify this fireplace under any
circumstances. Any parts removed for
servicing must be replaced prior to operating fireplace.
8.Turn fireplace off and let cool before
servicing, installing, or repairing. Only
a qualified service person should install, service, or repair this fireplace.
Have fireplace inspected annually by a
qualified service person.
9.You must keep control compartments,
burners, and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, pet
hair, etc. Turn off the gas valv e and pilot light before cleaning fireplace.
10. Have venting system inspected annually by a qualified service person. If
needed, have venting system cleaned
or repaired. See Cleaning and Mainte-nance, page 26.
11. Keep the area around your fireplace
clear of combustible materials, gasoline, and other flammable vapor and
liquids. Do not run fireplace where
these are used or stored. Do not place
items such as clothing or decorations
on or around fireplace.
12. Do not use this fireplace to cook food
or burn paper or other objects.
13. Do not use any solid fuels (wood, coal,
paper, cardboard, etc.) in this fireplace.
Use only the gas type indicated on fireplace nameplate.
14. This appliance, when installed, must be
electrically grounded in accordance
with local codes or, in the absence of
local codes, with the National Electri-
cal Code, ANS/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
15. Do not obstruct the flow of combustion and ventilation air in any way . Provide adequate clearances around air
openings into the combustion chamber
along with adequate accessibility clearance for servicing and proper operation.
16. Do not install fireplace directly on carpeting, vinyl tile, or any combustible
material other than wood. The fireplace
must set on a metal or wood panel extending the full width and depth of the
fireplace.
17. Do not use fireplace if any part has been
exposed to or under water . Immediately
call a qualified service person to arrange for replacement of the unit.
18. Do not operate fireplace if any log is
broken.
19. Do not use a blower insert, heat exchanger insert, or other accessory not
approved for use with this fireplace.
20. Do not operate fireplace with glass door
removed, cracked, or broken. Do not operate fireplace without screen in place.
2
105453
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
Top Louver
Panel
Nailing
Flange
Glass Door
Assembly
Lower Louver
Panel
Piezo Ignitor
Valve
Glowing Embers
Blower Adjustment
(Optional Installation)
Figure 1 - Vanguard Direct-Vent Fireplace BDV Series
Vent Opening
Stand-off
Log Set
Pilot Assembly
Burner
Grate Assembly
Lava Rock
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas CodeANS Z223.1, also known as NFPA 54* (USA)
or the current CAN/CGA-B149[.1 or .2]Installation Codes (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT
FEATURES
OPERATION
This direct-vent fireplace is clean burning
and vents easily through outside walls or
vertically using outside air for combustion.
Heat is generated by both realistic flames
and glowing embers. When used without
the blower accessory, the fireplace requires
no electricity making it ideal for emergency
backup heat.
PIEZO IGNITOR
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other
sources to light fireplace.
GLOSSARY OF
TERMS
Chase - A box-like enclosure to protect
venting from the elements when the venting
run is on the outside of a structure.
Mastic - A pliable sealent for use around
the vent terminal.
Snorkel Termination - A box that raises
the horizontal termination above ground
level clearances.
Vent Terminal - Mounted on an outside
wall or roof to separate the inlet and outlet of
the vent system and protect it from weather.
Vinyl Siding Standoff - A metal box that
separates the vent cap from vinyl siding.
Wall Thimble/Firestop - A metal plate
used to secure the vent pipe when it passes
through a wall or ceiling.
105453
3
®
20"
34
3
/
4
"
5/8" for drywall facing
Must maintain a minimum
1" clearance to combustibles
D
RW
FW
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
PRE-INSTALLATION
PREPARATION
LOCATION AND SPACE
REQUIREMENTS
Determine the safest and most efficient location for your Vanguard direct-vent fireplace.
Make sure that rafters and wall studs are not
in the way of the venting system. Choose a
location where the heat output is not affected
by drafts, air conditioning ducts, windows or
doors. Figure 2 shows some common locations. Read all venting information in this
manual. Be aware of all restrictions and
precautions before deciding the exact location for your fireplace.
When deciding the location of your fireplace, follow these rules:
1.Do not connect this fireplace to a chimney flue serving a separate solid-fuel
burning fireplace or appliance.
2.Due to high temperatures, do not locate this fireplace in high traffic areas
or near furniture or draperies.
3.Proper clearances must be maintained.
4.If your fireplace is to be installed directly on carpeting, vinyl tile, or any
combustible material other than wood,
it must be installed on a metal or wood
panel extending the full width and
depth of the fireplace. See Figure 3.
CLEARANCES
Minimum clearances to combustibles for
the fireplace are as follows:
Back, and sides0"/mm
Perpendicular walls6" (152mm)
Floor0"/mm
Ceiling to louver opening42" (1067mm)
Front36" (914mm)
Top of Standoffs0"/mm
See General Venting on pages 5 and 6 for
specific venting clearances.
FRAMING AND FINISHING
Figures 4 and 5 show typical framing of this
fireplace. Figure 6 on page 5 shows framing
for corner installation. All minimum clearances must be met. Do not install fireplace
directly on carpeting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel
extending the full width and depth of the
fireplace.
See Accessories on pages 32 and 33 for
mantel kits available for this fireplace. If you
are using a separate combustible mantel piece,
refer to Figure 7 on page 5 for proper installation height. You can install noncombustible
mantels at any height above the fireplace.
Figure 5 - Framing Clearances for Typical
Fireplace Installation
Figure 4 - Framing Clearances for Installation Against an Exterior Wall
4
105453
OWNER’S MANUAL
PRE-INSTALLA TION
PREPARA TION
Continued
13"
29"
5
/8"
12
34
58"
Figure 6 - Framing Clearances for Corner Installation
A
B
C
1
9
/4"
1
/4"
3
/4"
34
D
E
F
G
GENERAL VENTING
These models are approved for use with
Simpson Dura-Vent 6 5/8" direct-vent pipe
components and terminations as well as both
flex and rigid Vanguard vent components.
Your fireplace is approved to be vented either
41"
Nailing Tabs
1
2
3
4
5
6
7
Wall
through the side wall, or vertically using the
following guidelines:
• Only use Vanguard or Simpson DuraV ent GS venting components or kits specifically approved for this fireplace.
• Minimum clearance between vent pipes
and combustible materials is 1" (25 mm),
except where stated otherwise.
• Combustible material may be flush with
the top front of fireplace with a maximum thickness of 3/4".
• Do not recess venting terminals into a
wall or siding.
• Install horizontal venting with a 1/4" rise
for every 12" of run to war d the termination.
• You may paint the vent terminal with
450ºF (232ºC) heat-resistant paint to coordinate with the exterior finish.
• There must not be any obstruction such
as bushes, garden sheds, fences, decks,
or utility buildings within 24" from the
front of the termination cap.
• Do not locate termination cap where excessive snow or ice build up may occur.
Be sure to clear vent termination area after snow falls to prev ent accidental blockage of venting system. When using sno w
blowers, do not direct snow to wards vent
termination area.
When locating vent termination, it is important to observe the minimum clearances
shown in Figure 8, page 6. You will avoid
extra framing by positioning your fireplace
against an already existing framing member. The sides of the fireplace may be positioned directly against combustible walls.
*Check with local codes or with the current
CAN/CGA B149[.1 or .2] Installation Codes
for Canada or the USA Installations follow
the current National Fuel Gas Code, ANSZ223.1, also known as NFPA 54.
5
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
GENERAL VENTING
D
E
V
B
L
V
A = clearance above grade, veranda, porch, deck, or balcony
[*12 inches (305mm) minimum]
B = clearance to window or door that may be opened
[12 inches (305mm) minimum]
C = clearance to permanently closed window [minimum 12 inches
(305mm) recommended to prevent condensation on window]
D = vertical clearance to ventilated soffit located above the terminal
within a horizontal distance of 24 inches (610mm) from the
center-line of the terminal [18 inches (457mm) minimum]
E = clearance to unventilated soffit [12 inches (305mm) minimum]
F = clearance to outside corner (see below)
G = clearance to inside corner (see below)
H = *not to be installed above a meter/regulator assembly within
36 inches (914mm) horizontally from the center-line of the regulator
† vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings*
‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow
the current
Note: Local codes or regulations may require different clearances
C
F
V
B
TERMINATION CAP
National Fuel Gas Code, ANS Z223.1
Continued
Fixed
Closed
Openable
V
Openable
B
AIR SUPPLY INLET
X
B
Fixed
Closed
J
V
A
X
I = clearance to service regulator vent outlet [*72 inches (1829mm)
minimum]
J = clearance to non-mechanical air supply inlet to building or the
combustion air inlet to any other fireplace [*12 inches (305mm)
minimum]
K = clearance to a mechanical air supply inlet [*72 inches (1829mm)
minimum]
L = † clearance above paved side-walk or a paved driveway located on
public property [*84 inches (2133mm) minimum]
M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡]
N = clearance above a roof shall extend a minimum of 24 inches (610mm)
above the highest point when it passes through the roof surface and
any other obstruction within a horizontal distance of 18 inches (457mm)
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
WARNING: Read all instructions completely and thoroughly
before attempting installation.
Failure to do so could result in
serious injury, property damage
or loss of life. Operation of improperly installed and maintained
venting system could result in
serious injury, property damage
or loss of life.
WARNING: Seal all of the connections with high temperature
silicone (600°F/316° C) every time
a vent connection is made. Before joining elbows and pipes,
apply a bead of high temperature
silicone sealant (GE RTV 106/
Loctite RTV 81585) to the end of
the elbow or pipe. High temperature silicone must also be used to
re-seal any connections after
maintenance to venting system.
NOTICE: Failure to follow these
instructions will void the warranty.
INSTALLATION
PRECAUTIONS
Consult local building codes before beginning
the installation. The installer must make sure
to select the proper vent system for installation. Before installing vent kit, the installer
must read this fireplace manual and vent kit
instructions.
Only a qualified service person should install venting system. The installer must follow these safety rules:
• Wear gloves and safety glasses for
protection
• Use extreme caution when using ladders
or when on roof tops
• Be aware of electrical wiring locations
in walls and ceilings
The following actions will void the warranty on your venting system:
• Installation of any damaged venting
component
• Unauthorized modification of the venting system
• Installation of any component part not
manufactured or approved by DESA
International
• Installation other than as instructed by
these instructions
WARNING: This gas fireplace
and vent assembly must be
vented directly to the outside.
The venting system must NEVER
be attached to a chimney serving
a separate solid fuel burning appliance. Each gas appliance must
use a separate vent system. Do
not use common vent systems.
WARNING: Horizontal sections of this vent system require
a minimum clearance of 2" from
the top of the pipe and 1" minimum to the sides and bottom.
Vertical sections of this system
require a minimum of 1" clearance to combustible materials on
all sides of the pipe.
INSTALLATION PLANNING
There are two basic types of direct-vent
installation:
• Horizontal T er mination
• Vertical Termination
It is important to select the proper length of
vent pipe for the type of termination you
choose. It is also important to note the wall
thickness.
For Horizontal Termination: Select the
amount of vertical rise desired. The horizontal run of venting must have 1/4" rise for
every 12" of run towards the termination.
WARNING: Never run the vent
downward as this may cause excessive temperatures which
could cause a fire.
You may use one or two 90° elbows in this
vent configuration. See Horizontal Termina-tion Configurations on pages 10 and 11.
For Vertical Termination: Measure the
distance from the fireplace flue outlet to the
ceiling. Add the ceiling thickness, the vertical rise in an attic or second story, and allow
for sufficient vent height above the roofline.
You may use one or two 90° elbows in this
vent configuration. See Vertical TerminationConfigurations on pages 13 through 15.
Note:
You may use two 45° elbows in place
of a 90° elbow. You must follow rise to run
ratios when using 45° elbows.
For two-story applications, firestops are required at each floor level. If an offset is
needed in the attic, additional pipe and elbows will be required.
You may use a chase with a vent termination
with exposed pipe on the exterior of the
house. See Installing Vent System in a Chase,
below.
Your Vanguard direct-vent fireplace has
been tested for a minimum 3' rise with a
maximum 10" wall thickness. The maximum horizontal run is 20' with 8' vertical
rise (see Installation for Horizontal Termi-nation, page 8). The maximum vertical run
is 30' (see Installation for Vertical Termina-tion, page 12).
It is very important that the venting system
maintain its balance between the combustion air intake and the flue gas exhaust.
Certain limitations apply to vent configurations and must be strictly followed.
Installing Vent System in a Chase
A chase is a vertical box-like structure built
to enclose venting that runs along the outside of a building. A chase is not required for
such venting.
NOTICE: Treatment of firestops
and construction of the chase may
vary from building type to building type. These instructions are
not substitutes for the requirements of local building codes. You
must follow all local building
codes.
Note:
When installing in a chase, you should
insulate the chase as you would the outside
walls of your home. This is especially important in cold climates. Minimum clearance between vent pipes and combustible
materials such as insulation is 1".
After framing the chase (see Framing andFinishing on page 4) install the vent system
by following the installation instructions.
Continued
105453
7
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
VENTING
INSTALLATION
Continued
INSTALLATION FOR
HORIZONTAL TERMINATION
1.Determine the route your horizontal
venting will take.
of the horizontal vent termination on
the exterior wall must meet all local and
national building codes and must not
be easily blocked or obstructed.
WARNING: Do not recess vent
terminal into a wall or siding.
Snorkel terminations are available for
terminations requiring a vertical rise on
the exterior of the building (see Figures
9 and 10). Snorkel kit SVK is also available (see page 15). Follow the same installation procedures used for standard
horizontal terminations. If installing the
snorkel termination below grade (basement applications), you must provide
proper drainage to prevent water from
entering the snorkel termination (see
Figure 10). Do not back fill around the
snorkel termination.
2.Rigid vent pipes and fittings have special twist-lock connections. Assemble
the desired combination of pipe and elbows to the appliance adaptor with pipe
seams oriented towards the wall or floor .
Twist-lock Procedure: The female
ends of the pipes and fittings have four
locking lugs (indentations). These lugs
will slide straight into matching slots on
the male ends of adjacent pipes and fittings. (All connections must be sealed
with high temperature silicone sealant
as specified in the second warning statement on page 7.) Push the pipe sections
together and twist one section clockwise
approximately one-quarter turn until the
sections are fully locked. See Figure 11,
page 9.
must be supported every three feet. Use
wall straps for this purpose.
Flexible vent pipe must be installed with
spacer springs every 12". See Figure 11,
page 9. All connections must be clamped
tightly and sealed with high temperature
silicone sealant as specified in the second warning statement on page 7.
Note:
Note:
The location
Horizontal runs of vent
Snorkel
12" Minimum
To Ground Level
Figure 9 - Snorkel Termination
Snorkel
12" Minimum
To Ground Level
Adequate drainage
Figure 10 - Snorkel Termination with Drainage Pipe
8
105453
OWNER’S MANUAL
VENTING
INSTALLATION
Continued
3.Attach vent pipe assembly to the fireplace. Set fireplace in front of it’ s permanent location to insure minimum
clearances. Mark the wall for a 10"
square hole (for noncombustible material such as masonry block or concrete, a 7 1/2" diameter hole is acceptable). See Figure 12. The center of the
hole should line up with the centerline of the horizontal rigid vent pipe.
Cut a 10"x10" (254mm x 254mm)
square hole through combustible exterior wall (7 1/2" [190mm] diameter
hole if noncombustible). Frame as necessary (see Figure 12).
4" Clamp
Female
Locking
Lugs
Male
Slots
7" Clamp
Spacer
Spring
4" Flex
Pipe
7" Flex
Pipe
4.Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7 1/2" or 10" hole on the exterior
wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. Attach the vent cap with four wood screws
supplied (see Figure 13).
Note
: Replace the wood screws with appropriate fasteners for stucco, brick, concrete,
or other types of siding.
WARNING: Do not recess vent
termination in to any wall. This
will cause a fire hazard.
For vinyl siding, stucco, or wood exterior use vinyl siding standoffs between
vent cap and exterior wall. The vinyl siding standoff prevents e xcessive heat from
melting the vinyl siding material. Bolt the
vent cap to the standoff. Apply non-hardening mastic around outside edge of the
standoff instead of the vent cap assembly. Use w ood screws pro vided to attach
the standoff. See Figure 14.
5.Slide the wall thimble over the vent
pipe before connecting the horizontal
run to the vent cap (see Figure 15).
6.Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should
be a minimum of 1 1/4". Apply silicone
to the connection. Fasten all vent connections with screws provided. Refer
to Fir eplace Installation on page 16 for
instructions on securing unit to framing or floor.
7.Slide the wall thimble against the interior wall surface and attach with screws
provided (see Figure 15).
Cut Vinyl Siding
Away to Fit
Standoff
Wood Screw
Standoff
UP
Nut
Apply Mastic
to All Four Sides
Figure 14 - Installing Vinyl Siding Standoff
Vent Cap
Bolt
Rigid Vent Pipe Flexible Vent Pipe
Figure 11 - Vent Pipe Connections
Vent Opening
Combustible Wall
10"
(254mm)
10"
(254mm)
(Framing
Vent Opening
Noncombustible Wall
7 1/2"
(190mm)
Figure 12 - Vent Opening Requirements
105453
Detail)
Apply Mastic
to All Four
Sides
UP
Wood
Screw
Vent Cap
Figure 13 - Installing Horizontal Vent Cap
9
Interior Wall
Surface
Wall
Thimble
Vent Cap
(Horizontal
Termination)
Figure 15 - Connecting Vent Cap with
Horizontal Vent Pipe
Screw
Horizontal
Vent Pipe
Continued
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
VENTING
INSTALLATION
Continued
Horizontal Termination
Configurations
Figures 16 through 20 show different configurations for venting with horizontal termination. Each figure includes a chart with
vertical minimum/maximum and horizontal maximum dimensions which must be
met. All connections must be sealed with
high temperature silicone sealant as specified in the second warning statement on
page 7. All horizontal terminations require
1/4" rise per 12" of horizontal run.
(30° and 90° only, no vertical pipe)
(30° elbow, 1' vertical pipe, 90° elbow)
Note:
corner installation.
Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One
Figure 20 - Horizontal Termination Configuration for Rigid Venting Using Two 90
°
Elbows with Termination at 90° with Fireplace
105453
Continued
11
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
VENTING
INSTALLATION
Continued
INSTALLATION FOR
VERTICAL TERMINATION
1.Determine the route your vertical venting will take. If ceiling joists, roof rafters,
or other framing will obstruct the venting system, consider an offset (see Figure 21) to avoid cutting loadbearing
members.
these installation instructions for required clearances (air space) to combustibles when passing through ceilings,
walls, roofs, enclosures, attic rafters, etc.
Do not pack air spaces with insulation.
Also note maximum vertical rise of the
venting system and any maximum horizontal offset limitations. Offsets must
fall within the parameters shown in
Figure 8 on page 6.
2.Set the fireplace in desired location.
Drop a plumb line down from the ceiling to the position of the fireplace exit
flue. Mark the center point where the
vent will penetrate the ceiling. Drill a
small locating hole at this point.
Drop a plumb line from the inside of
the roof to the locating hole in the ceiling. Mark the center point where the
vent will penetrate the roof. Drill a
small locating hole at this point.
Wall Strap
Note:
Pay special attention to
Roof
Flashing
Flat Ceiling Installation
1.Cut a 10" square hole in the ceiling using the locating hole as a center point.
The opening should be framed to
10"x10" (254mm x 254mm) inside dimensions, as shown in Figure 12 on
page 9 using framing lumber the same
size as the ceiling joists. If the area
above the ceiling is an insulated ceiling or a room, nail firestop from the
top side. This prevents loose insulation
from falling into the required clearance
space. Otherwise, install firestop below
the framed hole. The firestop should be
installed with no less than three nails
per side (see Figure 22).
2.Assemble the desired lengths of pipe
and elbows necessary to reach from the
fireplace flue up through the firestop.
All connections must be sealed with
high temperature silicone sealant as
specified in the second warning statement on page 7. Be sure all pipe and
elbow connections are fully twistlocked (see Figure 11, page 9).
3.Cut a hole in the roof using the locating
hole as a center point. (Cover any exposed open vent pipes before cutting
hole in roof.) The 10"x10" hole must
be measured on the horizontal; actual
length may be larger depending on the
pitch of the roof. There must be a 1"
clearance from the vent pipe to combustible materials. Frame the opening as
shown in Figure 12 on page 9.
If area above is a room, install firestop
above framed hole.
4.Connect a section of pipe and extend
up through the hole.
Note:
If an offset is needed to avoid
obstructions, you must support the vent
pipe every 3 feet. Use wall straps for
this purpose (see Figure 21). Whenev er
possible, use 45° elbows instead of 90°
elbows. The 45° elbow offers less restriction to the flow of the flue gases
and intake air.
5. Place the flashing over the pipe
section(s) extending through the roof.
Secure the base of the flashing to the
roof and framing with roofing nails. Be
sure roofing material overlaps the top
edge of the flashing as shown in Figure
21. There must be a 1" clearance from
the vent pipe to combustible materials.
6.Continue to add pipe sections until the
height of the vent cap meets the minimum building code requirements described in Figure 8 on page 6.
must increase vent height for steep roof
pitches. Nearby trees, adjoining rooflines,
steep pitched roofs, and other similar factors may cause poor draft or down-drafting in high winds. Increasing the vent
height may solve this problem.
7.Twist-lock the vent cap onto the last
section of vent pipe and seal with high
temperature silicone sealant as specified in the second warning statement
on page 7.
Note:
If the vent pipe passes through any
occupied areas above the first floor, including
storage spaces and closets, you must enclose
pipe. You may frame and sheetrock the enclosure with standard construction material. Make
sure and meet the minimum allowable clearances to combustibles. Do not fill any of the
required air spaces with insulation.
Note
: Y ou
45° Elbow
Ceiling Firestop
Figure 21 - Offset with Wall Strap and 45
Elbows
If area above is not a room, install
firestop below framed hole.
°
Figure 22 - Installing Firestop
12
Cathedral Ceiling Installation
1.Remove shingles or other roof cover-
ing as necessary to cut the rectangular
hole for the support box. Mark the outline of the cathedral ceiling support box
on the roof sheathing using the locating hole as a center point.
2.Cut the hole 1/8" larger than the sup-
port box outline (see Figure 23, page 13).
105453
OWNER’S MANUAL
VENTING
INSTALLATION
Continued
3.Lower the support box through the hole
in the roof until the bottom of the box
extends at least 2" below the ceiling
(see Figure 23). Align the support box
vertically and horizontally using a level.
Temporarily tack the support box in
place through the inside walls and into
the roof sheathing.
4.Using tin snips, cut the support box from
the top corners down to the roofline and
fold the resulting flaps over the roof
sheathing (see Figure 24). Apply a bead
of non-hardening mastic around the top
edges of the support box to make a seal
between the box and the roof. Nail in
place with roofing nails. Remove any
combustible material that might be inside of the support box.
5.Complete the cathedral ceiling installation by following the same procedures outlined in steps 2 through 7 for
Flat Ceiling Installation, page 12
.
Vertical Termination Configurations
Figures 25 through 28 show four different configurations for vertical termination. All
connections must be sealed with high temperature silicone sealant as specified in the second
warning statement on page 7.
Figure 27 - Vertical Rigid Venting Configuration Using Two 90° Elbows
Install
RVF Kit Shown
Vertical V enting
V = 30' max.
Figure 28 - Vertical Rigid Venting
Configuration With No Horizontal Run
14
105453
OWNER’S MANUAL
VENTING
INSTALLATION
Continued
HIGH ALTITUDE
INSTALLATION
Your Vanguard direct-vent fireplace has
been AGA tested and approved for elevations from 0-2000 feet and CGA certified
for elevations from 0-4500 feet.
When installing this fireplace at an elevation
above 2000 feet (in the USA), you may need
to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea
level. Check with your local gas company for
proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check
with local authorities.
Consult your local gas company to help determine the proper orifice for your location.
For assistance with any high altitude installation contact DESA International’s Technical Service Department at 1-800-DESALOG (1-800-337-2564).
PARTS LISTS FOR VENTING
KITS AND COMPONENTS
Vanguard Rigid Venting
Number Description
BGFVK Basic Ground Floor Rigid Vent Kit
Includes: 7" x 60° Elbow, Extended
Adjustable Horizontal Termination,
Wall Thimble and 14 Screws
GFVKGround Floor Rigid Vent Kit
Includes: 7" x 60° Elbow, 7" Adjustable Galvanized Coaxial Pipe (7-12"),
Wall Thimble, Horizontal Termination, RTV Silicone and 16 Screws
BVKBasement Rigid Vent Kit
Includes: 7" x 30° Elbow, 7" x 4'
Galvanized Pipe, 7" x 90° Elbow, 7"
Adjustable Galvanized Pipe (7-12"),
Wall Thimble, Horizontal Termination, RTV Silicone and 20 Screws
CVKCorner Vent Kit
Includes: 7" x 30° Elbow, 7" x 90°
Elbow, 7" Adjustable Galvanized
Pipe (7-12"), 6" Pipe, Wall Thimble,
Horizontal Termination, RTV Silicone and 20 Screws
Vanguard Rigid Venting
(Cont.)
Number Description
SVKSnorkel Rigid Vent Kit
Includes: 7" x 30° Elbow, 7" x 4'
Galvanized Pipe, 7" x 90° Elbow, 7"
Adjustable Galvanized Pipe (7-12"),
Wall Thimble, 36" Snorkel Termination, RTV Silicone and 28 Screws
RVFRoof Rigid Vent Kit
Includes: Flue Restrictor, Storm
Collar, 7" x 30° Elbow, 7" x 4'
Galvanized Pipe, 7" x 2' Galvanized Pipe, 7" Adjustable Galvanized Pipe (7-12"), Firestop Support, Roof Flashing, RTV Silicone,
Vertical Termination, and 26 screws
D10007" x 12" Galvanized Coaxial
Pipe(6 pcs.)
D10107" x 24" Galvanized Coaxial
Pipe(6 pcs.)
D10207" x 48" Galvanized Coaxial
Pipe(6 pcs.)
D10307" Adjustable (7-12")
Galvanized Coaxial Pipe
(6 pcs.)
D10507" x 6" Galvanized Coaxial Pipe
(6 pcs.)
D20007" x 90° Elbow (6 pcs.)
D20107" x 45° Elbow (6 pcs.)
D20207" x 30° Elbow (6 pcs.)
D20307" x 60° Elbow (6 pcs.)
D3000Wall Strap/Offset Support
Number Description
Available from DESA International:
SD2040Simpson Dura-Vent GS
30° Elbow (6 pcs.)
SD2050Simpson Dura-Vent GS
60° Elbow (6 pcs.)
Available from Simpson Dura-Vent
Only:
9027" x 48" Pipe
9037" x 36" Pipe
9047" x 24" Pipe
9067" x 12" Pipe
9077" x 9" Pipe
9087" x 6" Pipe
9117" Adjustable (11"-14
940Wall Thimble
941Cathedral Ceiling Support Box
943Roof Flashing 0/12-6/12
943S Roof Flashing 7/12-12/12
9457" x 45° Elbow
950Vinyl Siding Standoff
953Storm Collar
963Ceiling Firestop
98136" Snorkel Termination
984Horizontal Termination Vent Cap
988Wall Strap
9907" x 90° Elbow
991Vertical High Wind Termination
5
/8") Pipe
105453
15
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
FIREPLACE
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your primary heating system. Do not install this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
NOTICE: A qualified service person must install fireplace. Follow
all local codes.
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces
next to fireplace. Installing fireplace next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.
Note:
Your fireplace is designed to be used
in zero clearance installations. Wall or framing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where stand-off
spacers are integrally attached. If stand-off
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing material. See framing details on
page 4.
Place the fireplace into position and shim
with noncombustible material if needed.
Nail the side flanges to the framing to secure
the unit in place. There are two floor brackets included with each unit. Use these as an
alternative method of securing the fireplace.
IMPORTANT:
before securing. If fireplace is not level it
will not work properly.
Make sure fireplace is level
CHECK GAS TYPE
Use proper gas type for the fireplace unit
you are installing. If you have conflicting
gas types, do not install fireplace. See dealer
where you purchased the fireplace for proper
fireplace according to your gas type.
INSTALLING OPTIONAL
BLOWER ACCESSORY
NOTICE: If installing blower in an
existing fireplace with gas connections, shut off gas supply and
disconnect heater from gas supply. Contact a qualified service
person to do this.
Attaching Thermal Switch to
DA3610T Thermostatically
Controlled Blower
When installing the DA3610T thermostatically controlled blower accessory, you must
first secure the thermal switch to the blower.
1.Remove the two hex head screws on the
blower assembly as shown in Figure 29.
2.Place the green wire between the bottom hole on the thermal switch bracket
and the bottom hole on the blower assembly. Insert one of the hex screws
into all three pieces and tighten.
3.Insert the top screw through the thermal switch bracket and into the blower
assembly. Tighten screw.
4.Connect the blue wire on the blower
assembly to the right side of the thermal switch.
5.Connect the black wire to the left side
of the thermal switch.
bly and grate/burner assembly are not shown
in Figures 30 through 33, page 17. They will,
however, be in your fireplace when you are
installing the blower. Also for clarity the
firebox is shown with dotted lines.
1.Open lower louver panel or remove f or
easier access.
2.Place the blower against the lower rear
wall of firebox outer wrapper with the
exhaust port directed upward. Align the
holes in the top mounting tabs of blower
with holes in wall of wrapper (see Figure 30, page 17). Using the two screws
provided, mount blower and tighten
screws securely.
Note:
thermal switch is comfortably under the
back of the firebox as shown in Figure
31, page 17.
3.Be sure to securely attach all wire terminals to terminals on blower motor
(and thermal switch where applicable)
and that the screw retaining the green
ground wire is tight.
4.Remove screws securing the plate containing the ON/OFF switch to the bottom of the firebox and set aside.
5.Place speed control against back of this
plate and push the plastic control shaft
through opening (see Figure 32, page 17).
6.While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise
until tight against the plate. Place control
knob provided onto shaft (see Figure 32,
page 17).
7.Replace plate containing switches and
tighten screws securely.
: For clarity, gas valve assem-
For DA3610T, make sure the
Blower Assembly
16
105453
OWNER’S MANUAL
FIREPLACE
INSTALLATION
Continued
8.Plug in blower power cord.
a. If your fir eplace system is installed
as a freestanding unit with an accessory mantel, determine whether
the power cord will exit the left side
or the right side of the firebox. Install one plastic bushing provided
into the 1 1/2" hole in the outer casing through which the power cord
will exit. Install the second plastic
bushing provided into the floor support bracket if exiting through the
right side (see Figure 33). Route
power cord through (both) plastic
bushing(s) and plug the power cord
into a properly grounded 3-prong
wall receptacle near the firebox.
b. If your fireplace system installation
is recessed and/or pre-wired, a
qualified installer must make all electrical connections for the outlet kit
included with the fireplace.
9.Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign objects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclockwise before continuing.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the
supplied wiring diagram decal on the
firebox bottom approximately 3" to the
right of the blower speed control
bracket (see Figure 33).
WARNING: Failure to position
the parts in accordance with supplied diagrams or failure to use
only parts specifically approved
with this heater may result in damage or personal injury.
11. Connect or reconnect gas supply to fireplace per Connecting Fir eplace to GasSupply on page 19 of this manual.
NOTICE: A qualified service person must connect fireplace to
gas supply. Follow all local codes.
Firebox
Bottom
Thermal
Switch
Firebox Back
Firebox Flange
Blower
Lower Rear
Wall of
Firebox
Wrapper
Screws
Blower
Lower Louver
Panel
Exhaust Port
Top
Mounting
Tab
Thermal Switch
Figure 31 - Locating Thermal Switch Against Back of Firebox
Speed
Control
Control
Knob
Locknut
Figure 32 - Attaching Speed Control to Firebox
Wiring
Diagram
Control Shaft
Plastic
Bushing
Side View
Figure 30 - Mounting Blower to Firebox
105453
Blower Speed
Control Bracket
Figure 33 - Installing Plastic Bushing and Wiring Diagram Sticker
17
Continued
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
FIREPLACE
INSTALLATION
Continued
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
NOTICE: A qualified service person must connect fireplace to
gas supply. Follow all local codes.
CAUTION: For propane units,
never connect heater directly to
the propane supply. This heater
requires an external regulator (not
supplied). Install the external
regulator between the heater and
propane supply.
Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff v alve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with g as connector (if allowed by local codes) (not
provided)
* An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the A.G.A. design-certified manual
shutoff valve from your dealer.
For propane connections only, the installer
must supply an external regulator. The external regulator will reduce incoming gas
pressure. You must reduce incoming gas
pressure to between 11 and 14 inches of
water. If you do not reduce incoming gas
pressure, heater regulator damage could
occur. Install external regulator with the
vent pointing down as shown in Figure 34.
Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to fireplace. If
requirements for locating manual shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
pipe is too small, undue loss of
pressure will occur.
CAUTION: Use pipe joint seal-
Check your building codes for any special
Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
ant that is resistant to liquid petroleum (LP) gas.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 35).
Propane
Supply
Tank
External
Regulator
Install sediment trap/drip leg in supply line
as shown in Figure 35. Locate sediment
trap/drip leg where it is within reach for
cleaning. Locate sediment trap/drip leg
where trapped matter is not likely to freeze.
A sediment trap traps moisture and contaminants. This keeps them from going into
fireplace gas controls. If sediment trap/drip
leg is not installed or is installed wrong,
fireplace may not run properly.
Vent
Pointing
Down
Figure 34 - External Regulator with Vent
Pointing Down (Propane Only)
A.G.A. Design-Certified
Manual Shutoff Valve with
1/8" NPT Tap*
Approved Flexible
Gas Line
3" Minimum
Cap Pipe Nipple Tee Joint
Sediment Trap/Drip Leg
Figure 35 - Gas Connection
Natural - From Gas
Meter (5" W.C. to 10.5"
W.C. Pressure )
LP - From External
Regulator (11" W.C. to
14" W.C. Pressure)
* The A.G.A. design-certified manual shutoff valve may be supplied with the appliance
or you can purchase it from your dealer.
18
105453
OWNER’S MANUAL
FIREPLACE
INSTALLATION
Continued
CONNECTING FIREPLACE
TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• sealant (resistant to propane/LP gas, not
provided)
1.Open lower louver door panel by gen-
tly pulling forward.
2.Route flexible gas line (provided by
installer) from manual shutoff valv e to
fireplace. Route flexible gas supply line
through one of the access holes on side
of fireplace.
3.Attach flexible gas line from gas sup-
ply to control valve (see Figure 36).
4.Check all gas connections for leaks. See
Checking Gas Connections.
To Gas Supply
(Natural)
Manual Shutoff Valve
CHECKING GAS
CONNECTIONS
WARNING: Test all gas piping and connections for leaks
after installing or servicing. Correct all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply
commercial leak test solution to
all gas joints. Bubbles forming
show a leak. Correct all leaks at
once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1.
Disconnect fireplace and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2
psig (3.5 kPa) will damage fireplace gas
regulator .
2.Cap off open end of gas pipe where
manual shutoff valve was connected.
3.Pressurize supply piping system by either opening propane supply tank valve
for propane gas fireplace or
main gas valve located on or near gas
meter for natural gas fireplace,
compressed air.
4.Check all joints of gas supply piping
system. Apply commercial leak test
solution to all gas joints. Bubbles forming show a leak. Correct all leaks at
once.
5.Reconnect fireplace and manual shutoff
valve to gas supply . Check reconnected
fittings for leaks.
opening
or using
To External Regulator
(Propane)
Control Valve
Flexible Gas Line from
Manual Shutoff Valve
Provided by Installer
Figure 36 - Attaching Flexible Gas Lines To The Control Valve
Continued
105453
19
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
FIREPLACE
INSTALLATION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1.Close manual shutoff valve (see Figure 37).
2.Pressurize supply piping system by either opening propane supply tank valve
for propane gas fireplace or
main gas valve located on or near gas
meter for natural gas fireplace,
compressed air.
3.Check all joints from propane supply
tank or gas meter to manual shutoff
valve (see Figure 38 for propane or Figure 39 for natural). Apply commercial
leak test solution to all gas joints.
Bubbles forming show a leak. Correct
all leaks at once.
Pressure Testing Fireplace Gas
Connections
1.Open manual shutoff valve (see Figure
37).
2.Open propane supply tank valve for
propane fireplace or main gas valv e located on or near gas meter for natural
gas fireplace.
3.Make sure control knob of fireplace is
in the OFF position.
4.Check all joints from manual shutoff
valve to thermostat gas valve (see Figure 38 for propane or Figure 39 for natural). Apply commercial leak test solution to all gas joints. Bubbles forming
show a leak. Correct all leaks at once.
5.Light fireplace (see Operating Fire-place, pages 24 and 25). Check all other
internal joints for leaks.
6.Turn off f ireplace (see To Turn Off Gasto Appliance, page 24).
opening
or using
INSTALLING OPTIONAL
WALL MOUNT SWITCH
GWMS2
1.Connect one terminal of 25 ft. wire for
the wall switch to the TPTH terminal
on the valve. Connect remaining wire
terminal to the TH terminal on the
valve. Make sure that the wire terminals are in the positions on the unit as
2.Route the 25 ft. wire through openings
provided on the sides of the fireplace
to a convenient location to mount your
switch.
3.Connect one bare wire end to each of
the terminals of the GWMS2 Wall
Switch.
4.Install the wall switch and cover in the
wall.
pictured in Figure 41, page 21. If wires
are not connected as shown the switch
will not work.
Propane Supply Tank
Manual
Shutoff Valve
Gas Valve
Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace
Manual
Gas Meter
Shutoff Valve
ON
Open
Manual
Shutoff
Valve
Figure 37 - Manual Shutoff Valve
POSITION
POSITION
Closed
OFF
Gas Valve
Figure 39 - Checking Gas Joints for Natural Gas Fireplace
20
105453
OWNER’S MANUAL
FIREPLACE
INSTALLATION
Continued
INSTALLING OPTIONAL
WIRELESS HAND-HELD
REMOTE CONTROL
ACCESSORY - GHRC
Installing Remote Receiver
1. Open bottom louver and locate the
switch bracket on the left.
2. Unscrew the switch bracket. Lean
bracket forward so you are able to access the back of the remote receiver.
3.Locate the battery clip mounted on the
back of the receiver. Slide a 9-volt battery (not included) through the clip.
4.Attach the terminal wires to the battery.
5.Remove the wire that runs from TH to
TPTH from the valve (see Figure 40).
6.Connect wires from reciever to TH and
TPTH on the valve (see Figure 41).
7.Replace the switch bracket.
Receiver
Terminal
Wires
Battery Clip
9-Volt Battery
Figure 42 - Attaching Battery to Receiver
Installing 9-Volt Battery in HandHeld Remote Control Unit
1.Remove battery cover on back of remote control unit.
2. Attach terminal wires to a 9-volt battery (not included). Place battery into
the battery housing.
3.Replace battery cover onto remote control unit.
Battery
Terminal
Wires
9-Volt
Battery
Cover
Remote
Control Unit
3.Grasp door by both sides and ease it
upward off of the lower bracket (see
Figure 45).
4.T o replace glass door, follow the above
instructions in reverse.
Top Louver
Panel
Figure 44 - Removing Top Louver Panel
Figure 40 - Disconnecting TH to TPTH
Wire
To Wall Optional
Remote Accessory
Figure 41 - Control Valve Terminals
Battery
Housing
Figure 43 - Installing Battery in HandHeld Remote Control Unit
REMOVING/REPLACING
GLASS DOOR
You must remove glass door to install optional brick liners, logs, lava rock, and ember material.
CAUTION: Do not operate this
fireplace with a broken glass door
panel or without the glass door
panel securely in place. For replacement part information see
Replacement Parts
1.Remove the upper louver panel by lifting upward and out (see Figure 44).
2.Remove the screws from the three tabs
at the top of the glass door while holding door securely keeping it from falling forward.
, page 30.
Screw
Glass Door
Assembly
Lower Bracket for
Glass Door Assembly
Figure 45 - Removing/Replacing Glass Door
Continued
105453
21
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
FIREPLACE
INSTALLATION
Continued
INSTALLING OPTIONAL
BRICK LINER D8037
WARNING: If fireplace has
been running, turn off and unplug fireplace. Let cool before
installing brick liner.
This brick liner kit is optional. You may
purchase brick liner from your local dealer
or see Accessories, page 32.
CAUTION: Always handle
brick panels with two hands. Do
not force brick panels into place.
Excessive force will break brick
panels.
Left Side
Brick Panel
Figure 46 - Installing Left Side Brick Panel
1.Remove glass door . See Removing/Replacing Glass Door, page 21.
2.If installing brick liner in new fireplace,
go to step 3. If installing brick liner in
an existing fireplace, carefully remov e
logs, lava rock, and ember material.
3.Install left side brick panel first by sliding it between the grate and the side of
the firebox (see Figure 46).
4.Slide the left retainer bracket against
the left side brick panel. Loosely secure the bracket screw . This secures the
left side brick panel.
5.Install the right brick panel using the
same method described in step 3.
6.Slide the right retainer bracket against
the right side brick panel. Loosely secure the bracket screw . This secures the
right side brick panel.
7.Install rear brick panel. Rest bottom
edge of panel on back edge of grate (see
Figure 47).
8.Loosely secure retainer brackets to
grate. Brackets are adjustable left to
right to allow proper placement of panel.
These will hold rear panel in place.
9.Tighten all bracket screws.
10. Follow instructions on page 23 to install
logs, lava rock, and ember material.
11. Replace glass door (see page 21).
Rear Brick Panel
Retaining Brackets
Figure 47 - Installing Rear Brick Panel and Retainer Brackets
22
105453
OWNER’S MANUAL
4
FIREPLACE
INSTALLATION
Continued
INSTALLING LOGS, LAVA
ROCK AND GLOWING
EMBERS
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
Each log is marked with a number. These
numbers will help you identify the log when
installing. It is very important to install
these logs exactly as instructed. Do not
modify logs. Only use logs supplied with
fireplace.
Remove glass door. See Removing/ReplacingGlass Door, page 21. Install logs according to
instructions for fireplace model numbers.
6.Pull ember material apart into pieces
no larger than a dime. Place these
pieces loosely and sparingly directly
onto the exposed section of the front
burner and along the space between the
burner and grate prongs (see Figure 52).
This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by
using too much ember material in one
area. It is not necessary to use all of the
ember material provided.
7.Replace the glass door. See Removing/Replacing Glass Door, page 21.
WARNING: The glass door
must be securely in place before
running this fireplace. Do not run
this fireplace if glass is missing
or broken.
1
3
Figure 50 - Installing Log No. 3
Fireplace Models
BDV34N(A) and BDV34P(A)
1.Place log #1 (back log) on top of grate.
Make sure the notches in the bottom of
the log fit over the grate (see Figure 48).
2.Rest log #2 (large front log) on the pins on
the front part of the grate (see Figure 49).
3.Place log #3 (crossover log) onto the
rear and front logs. Make sure it is seated
properly into the notch on the front log
and over the raised triangular portion of
the rear log as shown in Figure 50.
4.Place log #4 (small log) onto the front
left part of the grate making sure the
notches fit over the prong of the grate.
See Figure 51.
5.Place lava rock along sides and front
of firebox bottom in areas that are visible only. It is not necessary to use all
of the lava rock provided.
NOTICE: Do not put lava rock on
burner or under burner. Placing
lava rock on burner could cause
performance problems.
Figure 51 - Installing Log No. 4
Figure 48 - Installing Log No. 1
Ember Material
2
Figure 52 - Placing Ember Material on
Burner
105453
Figure 49 - Installing Log No. 2
23
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
OPERATING
FIREPLACE
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHA T TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. For ce or
attempted repair may result in a f ire
or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information
in column 1.
2.Open lower louver panel.
3.Disconnect the wire that runs from
TH to TPTH from the valve.
4.Turn off all electric power to the
fireplace.
5.Push in gas control knob slightly and
turn clockwise to “OFF”.
6.Wait f ive (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety information in column one. If you don't
smell gas, go to the next step.
7. The pilot is located by the main
burner and should not require accessing for lighting.
8.Turn knob on gas control counterclockwise to “PILOT”.
9.Push in control knob all the way and
hold. Immediately light the pilot by
repeatedly depressing the piezo
spark ignitor until a flame appears.
Continue to hold for about one (1)
minute after the pilot is lit. Release
knob and it will pop back. Pilot
should remain lit. If it goes out, repeat steps 5 through 8.
•
If knob does not pop up when released, stop and immediately call your
service technician or gas supplier.
• If the pilot will not stay lit after sev-
eral tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.
10. Reconnect the wire that runs from
TH to TPTH from the valve.
Gas Control Knob
Piezo
Ignitor
Variable Control Knob
I
T
O
L
I
O
P
N
F
F
O
H
L
O
11. Turn on all electric power to the
fireplace.
12. Turn gas control counterclockwise
to “ON”.
13. This valve is equipped with a HI/LO
feature. Set fir eplace input as desired.
14. Close lower louver panel.
TO TURN OFF GAS
TO APPLIANCE
1.Open lower louver panel.
2a. If using optional ON/OFF switch,
turn ON/OFF switch to “OFF”.
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to prevent draining battery.
3.Turn off all electrical power to the
appliance if service is to be performed.
4.Push in gas control knob slightly and
turn clockwise to “OFF”.
5.Close lower louver panel.
Shutting Off Burners Only (pilot
stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
1.Turn control knob clockwise
to the PILOT position.
2.Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.Remove glass door (see Removing/
Replacing Glass Door, page 21).
2.Follow steps 1 through 8 under Lighting Instructions.
3.Depress control knob and light pilot
with match.
4.Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 10 through 14, column 2.
5.Replace glass door (see Removing/Replacing Glass Door, page 21).
Figure 53 - Control Valve
24
105453
OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
OPTIONAL REMOTE
OPERATION
Note:
The GHRC receiver and handheld remote control accessory must be
purchased separately (See Accessories on
page 33). Follow instructions included
with the remote control.
NOTICE: You must light the pilot
before using the hand-held remote control unit. See
Instructions,
page 24.
1.After lighting, let pilot flame burn for
about one minute. Turn control knob
on the control valve to ON position.
Turn flame adjustment knob anywhere between HI and LO. Turn the
knob to the REMOTE setting.
The burner may light if hand-held remote ON button was on when selector
switch was last turned off. Y ou can now
turn the burners on and off with the
hand-held remote control unit.
IMPORTANT:
Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF button on the hand-held remote control unit for up to 3 seconds
to assure proper operation.
2.Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on
the heater to the OFF position.
Lighting
Note
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening
the lower louver panel on the fireplace.
Blower controls are located on the left
side of the switch bracket to the left just
inside the louver panel.
Both the GA3700 manual blower and the
DA3610T thermostatically controlled
blower have an ON setting and an OFF
setting. The blower will only run when the
switch is in the ON position. In the OFF
position, the blower will not operate.
Note for DA3610T Only:
and blower will not turn on and off at the
same time. The fireplace may run for several minutes before the blower turns on.
After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
:
The blower helps distribute heated air
from the fireplace. Periodically check the
louvers of the firebox and remove any
dust, dirt, or other obstructions that will
hinder the flow of air.
Blower Control Knob
(Optional Accessory)
OFF
ON
REMOTE OFF ON
Remote Control Knob in
Remote Position (Optional
Remote Control)
Figure 54 - Setting the Remote Control
Knob, Valve Control Knob, and Flame
Adjustment Knob for Remote Operation
Your fireplace
Flame
Adjustment
Knob
N
O
T
O
L
I
P
Control Knob
in On Position
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the
proper flame height. Alterations may have
occurred during shipping and handling. Call
a qualified service person to readjust the
pilot if necessary.
The height of the thermopile must be 3/8" to
1/2" above the pilot flame as shown in Figure
55. The thermocouple must be at a height of
about 1/8" above the pilot flame. The flame
from the pilot burner must extend beyond
both the thermocouple and thermopile.
If your pilot assembly does not meet these
requirements:
• turn fireplace off (see To Turn Of f Gas toAppliance, page 24)
• see Troubleshooting, pages 27 through 29
Thermopile
3/8" to 1/2"
Pilot Burner
1/8"
L
O
O
F
F
I
H
Piezo
Ignitor
Figure 55 - Pilot Assembly
Thermocouple
105453
Continued
25
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
INSPECTING
BURNERS
Continued
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or
floating. Flame patterns will be different
from unit to unit and will vary depending on
installation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift or "ghost". This
can be dangerous. Inspect the flames after
installation to ensure proper installation and
performance.
Figure 56 shows a typical flame pattern for
models BDV34N(A) and BDV34P(A).
If burner flame pattern differs from that
described:
• turn fireplace off (see To Turn Off Gas toAppliance, page 24)
• see Troubleshooting, pages 27 through 29
GLASS DOOR
WARNING: Handle glass door
panel with care. Do not strike,
slam or otherwise abuse glass.
Do not operate fireplace with the
glass door removed, cracked, or
broken.
WARNING: Do not use abrasive cleaners as this may damage
glass. Use a nonabrasive household glass cleaner to clean glass.
Do not clean glass when hot.
Glass must be cleaned periodically. During
start-up it is normal for condensation to
form on the inside of the glass causing lint,
dust, and other airborne particles to cling to
the glass surface. During initial start-up a
slight film may form on the glass due to
paint curing. The glass should be cleaned
several times with a non-ammonia, nonabrasive household cleaner and warm water
after the first two weeks of operation. Thereafter, clean the glass two or three times
during each heating season, depending on
the usage and circumstances present. Refer
to Removing/Replacing Glass Door on page
21 of this manual when removing glass door
for cleaning.
Use only the glass door replacement intended for this fireplace (see ReplacementParts, page 30 for detail on ordering). No
substitutions may be made. See Removing/Replacing Glass Door, page 21 for instructions for replacing glass door.
WARNING: Do not operate
fireplace with the glass door removed, cracked, or broken.
PILOT AND BURNERS
• Remove ember material before cleaning
burners and replace when cleaning is
complete.
• Burner and controls should be cleaned with
compressed air to remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to
Installing Logs, Lava Rock, and Glowing
Embers, page 23, to properly replace logs.
• Use a vacuum cleaner to remove an y carbon build up on logs.
• Replace log(s) if broken. See Replace-ment Parts on page 30.
• Replace ember material periodically as
needed. See Replacement P arts on page 30.
Figure 56 - Typical Flame Pattern for
BDV34N(A) and BDV34P(A)
CLEANING AND
MAINTENANCE
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace
clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
WARNING: Only parts supplied by the manufacturer should
be used when replacing broken
or damaged glass door panel (see
Replacement Parts
glass door panel is a complete
unit. No substitute materials may
be used.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep children and pets away from glass.
If glass has been broken, carefully remove
glass door (see Removing/Replacing GlassDoor, page 21). Vacuum all glass pieces
with a shop vac.
CAUTION: Do not vacuum if
pieces are hot.
, page 30). This
26
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1.Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced immediately by a qualified service person.
2.Remove the vent cap and shine a flashlight into the vent. Remove any foreign
material.
3.Check for evidence of excessive condensation. Continuous condensation
can cause corrosion of caps, pipes, and
fittings and can be caused by having
excessive lateral runs, too man y elbows,
or exterior portions of the system being exposed to cold weather.
4.Inspect joints to verify that no pipe section or fitting has been disturbed and
loosened. Check mechanical supports
such as wall straps for rigidity.
105453
OWNER’S MANUAL
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s Technical Service web
site at www.desatech.com.
Note:
All troubleshooting items are listed in
order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at pilot
When ignitor button is pressed, there is
spark at pilot but no ignition
WARNING: Turn off heater
and let cool before servicing. Only
a qualified service person should
service and repair heater.
POSSIBLE CAUSE
1. Ignitor electrode not connected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or manual shutoff
valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. Depleted gas supply (propane models only)
6. Pilot is clogged
7. Gas regulator setting is not correct
CAUTION: Never use a wire,
needle, or similar object to clean
pilot. This can damage pilot unit.
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
3. Tighten nut holding piezo ignitor. Nut
is located behind the mounting bracket.
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open manual
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is
removed
5. Contact local propane gas company
6. Clean pilot (see Cleaning and Maintenance,
page 26) or replace pilot assembly
7. Replace gas control
Pilot lights but flame goes out when control
knob is released
105453
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This problem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged pilot
5. Thermocouple connection loose at control valve
6. Thermocouple damaged
7. Control valve damaged
www.desatech.com
27
1. Press in control knob fully
2. After pilot lights, keep control knob
pressed in 30 seconds
3. Fully open manual shutoff valve
4. A) Contact local gas company
B) Clean pilot (see Cleaning andMaintenance, page 26) or replace pilot
assembly
5. Hand tighten until snug, then tighten
1/4 turn more
6. Replace thermocouple
7. Replace control valve
Continued
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner does not light after pilot is lit
Delayed ignition burner
Burner backfiring during combustion
Slight smoke or odor during initial operation
Heater produces a whistling noise when
burner is lit
POSSIBLE CAUSE
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Thermopile leads disconnected or improperly connected
4. Thermopile is defective
1. Manifold pressure is too low
2. Burner porting or orifice clogged
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Residues from manufacturing processes
and logs curing
1. Turning control knob to HI position
when burner is cold
2. Air in gas line
3. Dirty or partially clogged burner orifice
REMEDY
1. Clean burner (see Cleaning and
Maintenance, page 26) or replace burner
orifice
2. Contact local propane or natural gas
company
3. Reconnect leads (see Wiring Diagram,
page 30)
4. Replace thermopile
1. Contact local propane or natural gas
company
2. Clean burner (see Cleaning and Main-tenance, page 26) or replace burner orifice
1. Clean burner (see Cleaning andMaintenance, page 26) or replace burner
orifice
2. Replace damaged burner
3. Replace gas control
1. Problem will stop after a few hours of
operation
1. Turn control knob to LO position and
let warm up for a minute
2. Operate burner until air is removed from
line. Have gas line checked by local propane gas company
3. Clean burner (see Cleaning andMaintenance, page 26) or replace burner
orifice
Glass soots
Fireplace produces a clicking/ticking noise
just after burners are lit or shut off
1. Flame impingement on logs
2. Debris around burner air mixer
1. Metal expanding while heating or contracting while cooling
www.desatech.com
28
1. Adjust the log set so that the flame does
not excessively impinge on it
2. Inspect the opening at the base of the
burner to see that it is NOT packed with
any type of material
1. This is common. If noise is excessive,
contact qualified service person
105453
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
OWNER’S MANUAL
IMPORTANT:
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Fireplace produces unwanted odors
Fireplace shuts off in use
Operating fireplace where impurities in air exist may create odors. Cleaning supplies,
POSSIBLE CAUSE
1. Gas leak. See Warning statement
above
1. High or gusting winds
2. Low line pressure
3. Pilot is partially clogged
4. Inner vent pipe leaking exhaust gasses
into system.
5. Horizontal vent improperly pitched
6. Glass too loose and air tight gasket leaks
in corners after usage
7. Bad thermopile or thermocouple
8. Improper vent cap installation
REMEDY
1. Locate and correct all leaks (see Checking Gas Connections, page 19)
1. Fireplace has been tested for up to
40mph winds. However, extreme conditions may occur. See Lighting Instruc-tions on page 24.
2. Contact local propane or natural gas
company
3. Clean pilot (see Cleaning and Mainte-nance, page 26)
4. Locate and correct all leaks (see Check-ing Gas Connections, page 19)
5. Horizontal vent termination should slope
down only enough to prev ent an y water
from entering the unit. The maximum
downward slope of the vent termination
is 1/4" for any horizontal run.
6. Tighten glass
7. Replace faulty component
8. Check for proper installation and freedom from debris or blockage
Gas odor even when control knob is in OFF
position
Gas odor during combustion
Dark residue on logs or inside of fireplace
105453
1. Gas leak. See Warning statement
above
2. Control valve defective
1. Gas leak. See Warning statement
above
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
www.desatech.com
29
1. Locate and correct all leaks (see Checking Gas Connections, page 19)
2. Replace control valve
1. Locate and correct all leaks (see Check-ing Gas Connections, page 19)
1. Properly locate logs (see Installing Logs,Lava Rock, and Glowing Embers, page 23)
2. Clean out air holes at burner inlets. Periodically repeat as needed
3. Remove blockage or replace burner
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Technical Service Department at 1-800-DESA
LOG (1-800-337-2564).
When calling DESA International, have ready
• your name
• your address
• model number of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the defective part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.
When calling DESA International, have ready
• model number of your fireplace
• the replacement part number
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International’s
Technical Service web site at
www.desatech.com.
WIRING DIAGRAM
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Variable
Fan Switch
1
Off
110/115
V.A.C.
Figure 57 - Blower Wiring Diagram for Thermostat-Controlled Models
Black
White
Green
2
On
Fan Switch
(N.O.)
Red
Black
Red
Black
SERVICE HINTS
When Gas Pressure Is Too Low:
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low
(propane units only)
When Gas Quality Is Bad:
• pilot will not stay lit
• burners will produce flames and soot
• fireplace will backfire when lit
If you feel your gas pressure is too low or gas
quality is bad, contact your local natural or
propane/LP gas supplier.
940 x 1016 x 533mm940 x 1016 x 533mm
Weight, lbs/kg
Fireplace132 lbs/60 kg132 lbs/60 kg
Shipping135 lbs/61 kg135 lbs/61 kg
105453
31
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
ACCESSORIES
Purchase these fireplace accessories from
your local dealer. If they can not supply
these accessories, call DESA International’s
Sales Department at 1-800-432-2382 for
information. You can also write to the address listed on the back page of this manual.
CABINET MANTEL
GM100F Series - Walnut
Finished
GM101U Series - Unfinished
GM106F Series - Oak Finished
with Medium Stain
GM107U Series - Unfinished
GM102W Series - Off White Paint
Shown with optional base and laminate
hearth and mantel trim accessories.
Dimensions (WxHxD): 56 3/4" x 48 3/4" x 22 7/8"
HEARTH BASE TRIM KIT
(Not Shown)
G3003J Series - Jade Marble
Laminate
G3003S Series - Sandstone
Marble Laminate
G3003B Series - Black Onyx
Marble Laminate
HARDWOOD HEARTH BASE
G3000F Series- Walnut Finished
G3001U Series - Unfinished
G3006F Series - Oak Finished
with Medium Stain
G3007U Series - Unfinished Oak
G3004W Series- Off White Paint
The hearth base creates a handsome riser for
the fireplace (cannot be used with corner
mantel).
Dimensions (WxHxD): 58" x 6 1/2" x 28 9/16"
SLIM HEARTH BASE
(Not Shown)
G3005J Series - Jade Marble
Laminate
G3005S Series - Sandstone
Marble Laminate
G3005B Series - Black Onyx
Marble Laminate
The slim hearth base allows you to further
customize your fireplace.
Dimensions (WxHxD): 41 7/8" x 5/8" x 10"
MANTEL TRIM (Not Shown)
G3002J Series - Jade Marble
Laminate
G3002S Series - Sandstone
Marble Laminate
G3002B Series - Black Onyx
Marble Laminate
MANUAL BLOWER KIT
GA3700
Manual-variable control blower accessory for
the BDV Series fireplaces.
THERMOSTATICALLYCONTROLLED BLOWER KIT
DA3610T
Provides better heat distribution. Blower
turns off and on automatically, as needed.
Complete installation and operation instructions included in this manual.
CORNER MANTEL
GM200F Series - Walnut
Finished
GM201U Series - Unfinished
Shown with optional laminate mantel trim
accessory.
Dimensions (WxHxD): 60 7/8" x 48 3/4" x 34 5/8"
BRICK LINER
D8037 (Not Shown)
This brick liner adds a touch of style to your
direct-vent fireplace and comes with easy to
follow instructions for installation.
32
105453
ACCESSORIES
Continued
DUPLEX OUTLET KIT
GA3555 (NOT SHOWN)
For built-in installation when accessory
blowers are used.
BRASS PERIMETER TRIM
KIT - GA6090 (Not Shown)
Optional three sided brass trim kit covers
unfinished edges around fireplace. Provides
a finished appearance with the class of brass.
BRASS LOUVER KIT
D6034 (Not Shown)
These louvers will give your fireplace an
elegant look and allows you to customize
your fireplace. They easily replace the standard black louvers by screwing into place.
DECORATIVE 2-PIECE
BRASS ACCENT TRIM
D7034 (Not Shown)
OWNER’S MANUAL
RECEIVER AND HAND-HELD
REMOTE CONTROL KIT
GHRC SERIES
For all models. Allows the heater to be
turned on and off conveniently.
ON/OFF WALL MOUNT
SWITCH - GWMS2
For all models. Allows the heater to be
manually turned on and off.
These strips have a magnetic backing which
makes installation and removal quick and
easy. They are designed to go at the top and
bottom of the glass door on BDV units.
Note:
Remove the plastic film covering on
strips before installing on fireplace.
FIREPLACE SCREEN
DS34
For all models. This fireplace screen easily
attaches to the front glass panel with included clips.
105453
33
®
DIRECT-VENT FIREPLACE (NATURAL/PROPANE)
ILLUSTRATED
PARTS
BREAKDOWN
BDV34N(A)
37
33
7
2
11 (Included in
Hardware Pack)
1
38
31-4
31-2
31-3
31-1
29
44
6
25
43
42
26
27
40
39
32
9
17
28
34
6
10
35
46
5
4
13
14
15
5
12
8
5
18
6
20
32
7
41
32
19
30
24
36
21
16
28
22
23
45
3
34
105453
OWNER’S MANUAL
PARTS LIST
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions
listed under Replacement Parts on page 30 of this manual.
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions
listed under Replacement Parts on page 30 of this manual.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
DIRECT-VENT FIREPLACE
DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first
purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater
to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST
be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts.
Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance
with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,
labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE;
AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND
DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
105453 01
NOT A UPC
105453-01
55753
Rev. B