Desa B70D, R70D User Manual

Page 1
PORTABLE
FORCED
AIR HEATER
OWNER’S MANUAL
Heater Size: 70,000 Btu/Hr
Models: R70D and B70D
H.S.I. Series
IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
®
ARL LOGO
Page 2
70,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
SAFETY INFORMATION
WARNINGS
IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper­ate, or service this heater. Im­proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning re­semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include preg­nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
• Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Ne ver use gasoline, naphtha, paint thinners, alco­hol, or other highly flammable fuels.
• Fueling a) Personnel involv ed with fueling shall
be qualified and thoroughly familiar with the manufacturer’s instructions and applicable federal, state, and lo­cal regulations regarding the safe fu­eling of heating units.
b) Only the type of fuel specified on the
heater’s data plate shall be used.
c) All flame, including the pilot light, if any,
shall be extinguished and the heater al­lowed to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-
line connections shall be inspected for leaks. An y leaks shall be repaired prior to returning the heater to service.
e) At no time shall more than one day’s
supply of heater fuel be stored inside a building in the vicinity of the heater . Bulk fuel storage shall be outside the structure.
f) All fuel storage shall be located a
minimum of 25 feet from heaters, torches, welding equipment, and simi­lar sources of ignition (exception: the fuel reservoir integral with the heater unit).
g) Whenever possible, fuel storage shall
be confined to areas where floor pen­etrations do not permit fuel to drip onto or be ignited by a fire at lower elevation.
h) Fuel storage shall be in accordance
with the federal, state, or local author­ity having jurisdiction.
• Never use heater where gasoline, paint thinner, or other highly flammable v apors are present.
• Follow all local ordinances and codes when using heater.
• Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet. It is further rec­ommended that these enclosure materi­als be of a fire retardant nature. These enclosure materials shall be securely fas­tened to prevent them from igniting or from upsetting the heater due to wind action.
• Use only in well-vented areas. Before using heater, provide at least a three­square-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monoxide, which is listed by the State of California as a reproductive toxin under Proposition 65.
• Use only in places free of flammable va­pors or high dust content.
• Use only the electrical voltage and fre­quency specified on model plate.
• Use only a three-prong, grounded exten­sion cord.
• Minimum heater clearances from com­bustibles:
Outlet: 8 Ft. Sides: 4 Ft. Top: 4 Ft. Rear: 4 Ft.
• Locate heater on a stable and level sur­face if heater is hot or running or a fire may occur.
• When moving or storing heater, keep heater in a level position or fuel spillage may occur.
• Keep children and animals away from heater.
• Unplug heater when not in use.
• When used with thermostat, heater may start anytime.
• Never use heater in living or sleeping areas.
• Never block air inlet (rear) or air outlet (front) of heater.
• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
• Never attach duct work to front or rear of heater.
• Approved by the New York City Fire Department under certificate of approval #4803, #4860, #4908, or #4909. To be used only at construction sites in accor­dance with applicable New York City Codes, Regulations, Rules, Directives, Permits, etc.
2
103685
Page 3
OWNER’S MANUAL
PRODUCT IDENTIFICATION
Hot Air Outlet
Lower Shell
Fuel Tank
Side Cover
Ignition Control Assembly (assembly on inside of side cover)
Power Cord
Figure 1 - 70,000 Btu/Hr
Handle
THEORY OF OPERATION
The Fuel System: The air pump forces air through the air line. The air is then pushed through the nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
Combustion Chamber
Ignitor
The Ignition System: The ignition con­trol assembly provides power to the ignitor. This ignites the fuel/air mixture in the com­bustion chamber.
The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.
Motor
Fan
Upper Shell
Fan Guard
Air Filter End Cover
Air Pump
Air Intake Filter
UNPACKING
1. Remove all packing items applied to
heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If
heater is damaged, promptly inform dealer where you bought heater.
Fuel Cap
Clean Heated Air Out
Fuel Tank
Figure 2 - Cross Section Operational View
103685
Nozzle
Air For Fuel System
Fuel Filter
Air Line To Burner
Air For Combustion And Heating
Cool Air In
Air Output Filter
Ignition Control Assembly
Fuel
3
Page 4
70,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
FUELS
WARNING: Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gaso­line, naphtha, paint thinners, al­cohol, or other highly flammable fuels.
Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in a clogged fuel filter and/or nozzle.
IMPORTANT:
storage container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the ignition control assembly to shut down the heater. Foreign matter may also require you to clean fuel system often.
Use a KEROSENE ONLY
VENTILATION
Follow the minimum fresh, outside air ventilation require­ments. If proper fresh, outside air ventilation is not provided, car­bon monoxide poisoning can occur. Provide proper fresh, out­side air ventilation before run­ning heater.
Provide at least a three-square-foot opening of fresh, outside air for each 100,000 Btu/Hr rating. Provide extra fresh air if more heat­ers are being used.
Example:
one of the following:
• a two-car garage door (16 feet wide open­ing) raised two inches
• a single-car garage door (9 feet wide opening) raised three inches
• two windows (30 inches wide opening) raised six inches
A 70,000 Btu/Hr heater requires
OPERATION
WARNING: Review and un-
derstand the warnings in the
Safety Information
2. They are needed to safely op­erate this heater. Follow all local codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety infor ­mation.
2. Fill fuel tank with kerosene or No. 1 fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into three­prong, grounded extension cord. Exten­sion cord must be at least six feet long.
Extension Cord Wire Size Re­quirements
• 6 to 10 feet long, use 18 AWG rated
cord
• 11 to 100 feet long, use 16 AWG
rated cord
• 101 to 200 feet long, use 14 AWG
rated cord
5. Plug extension cord into standard 120 volt/ 60 hertz, three-hole, grounded outlet.
Note: Ignitor will preheat for five sec­onds then heater will start.
section, page
TO STOP HEATER
Unplug extension cord from outlet.
TO RESET HEATER
1. Unplug extension cord from outlet and wait 10 seconds (two minutes if heater has been running).
2. Plug extension cord into standard 120 volt/ 60 hertz, three-hole, grounded outlet.
Note:
Ignitor will preheat for five sec-
onds then heater will start.
4
103685
Page 5
OWNER’S MANUAL
STORING, TRANSPORTING, OR SHIPPING
Note:
If shipping, transport companies re-
quire fuel tanks to be empty.
1. Drain fuel tank. Drain fuel through fuel cap opening. Be sure all fuel is re­moved.
2. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur­ing future use.
3. Replace fuel cap. Properly dispose of old and dirty fuel. Check with local auto­motive service stations that recycle oil.
4. If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.
IMPORTANT:
summer months for use during next heating season. Using old fuel could damage heater.
Do not store kerosene over
PREVENTATIVE MAINTENANCE SCHEDULE
WARNING: Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
Item
Fuel tank
Air output and lint filters
Air intake filter
Fuel filter
Ignitor
Fan blades
Motor
How Often
Flush every 150-200 hours of opera­tion or as needed.
Replace every 500 hours of operation or once a year.
Wash and dry with soap and water every 500 hours of operation or re­place as needed.
Clean twice a heating season or re­place as needed.
No maintenance required.
Clean each season or as needed.
Not required/permanently lubricated
How To
See Storing, Transporting, or Shipping
See Air Output, Air Intake, and Lint Filters, page 7
See Air Output, Air Intake, and Lint Filters, page 7
See Fuel Filter, page 8
See Fan, page 7
103685
5
Page 6
70,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s technical service web site at www.desatech.com.
FAULT CONDITION
Motor does not start five seconds after heater is plugged in
Motor starts and runs but heater does not ignite
WARNING: Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
POSSIBLE CAUSE
1. No power to heater
WARNING: High voltage!
2. Bad electrical connection between mo­tor and ignition control assembly or ig­nition control assembly and power cord
3. Blown fuse on ignition control assembly
4. Binding pump rotor
5. Defective ignition control assembly
6. Defective motor
1. No fuel in tank
2. Pump pressure incorrect
3. Dirty fuel filter
4. Obstruction in nozzle
5. Water in fuel tank
REMEDY
1. Check circuit breaker in electrical panel
2. Check all electrical connections. See Wiring Diag ram, page 11
3. See Ignition Control Assembly, page 8
4. If fan does not turn freely, see Pump Rotor, page 10
5. Replace ignition control assembly
6. Replace motor
1. Fill tank with kerosene
2. See Pump Pressure Adjustment, page 7
3. See Fuel Filter, page 8
4. See Nozzle Assembly, page 9
5. Drain and flush fuel tank with clean kerosene. See Storing, T ransporting , or Shipping, page 5
Heater ignites but ignition control assembly shuts heater off after a short period of time
WARNING: High voltage!
6. Bad electrical connection between igni­tor and ignition control assembly
7. Defective ignitor
8. Defective ignition control assembly
1. Pump pressure incorrect
2. Dirty air intake, air output, and/or lint filter
3. Dirty fuel filter
4. Obstruction in nozzle
5. Photocell assembly not properly in­stalled (not seeing the flame)
WARNING: High voltage!
6. Dirty photocell lens
7. Bad electrical connection between pho­tocell and ignition control assembly
8. Defective photocell
9. Defective ignition control assembly
www.desatech.com
6. Check electrical connections. See Wir­ing Diagram, page 11
7. Replace ignitor, see page 8
8. Replace ignition control assembly
1. See Pump Pressure Adjustment, page 7
2. See Air Output, Air Intake, and Lint F il- ters, page 7
3. See Fuel Filter, page 8
4. See Nozzle Assembly, page 9
5. Make sure photocell boot is properly seated in bracket
6. Clean photocell lens
7. Check electrical connections. See Wir- ing Diagram, page 11
8. Replace photocell
9. Replace ignition control assembly
6
103685
Page 7
OWNER’S MANUAL
SERVICE PROCEDURES
WARNING: Never service heater while it is plugged in, op­erating, or hot. Severe burns and electrical shock can occur.
UPPER SHELL REMOVAL
1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together.
2. Lift upper shell off.
3. Remove fan guard.
Upper Shell
Fan Guard
Figure 3 - Upper Shell Removal
FAN
IMPORTANT:
before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.
Remove fan from motor shaft
Fan
Motor
Flush
Motor Shaft
Setscrew
Figure 4 - Fan Cross Section
AIR OUTPUT, AIR INTAKE, AND LINT FILTERS
1. Remove upper shell (see Upper Shell Removal).
2. Remove filter end cover screws using 5/16" nut-driver.
3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 5).
6. Replace filter end cover.
7. Replace fan guard and upper shell.
IMPORTANT:
Do not oil filters.
Air Intake Filter
Filter End Cover
Fan Guard
PUMP PRESSURE ADJUSTMENT
1. Remove pressure gauge plug from filter end cover.
2. Install accessory pressure gauge (part number HA1180).
3. Start heater (see Operation, page 4). Allow motor to reach full speed.
4. Using a flat blade screwdriver, adjust pressure. Turn relief valve to right to increase the pressure. T urn relief valve to left to decrease the pressure. Set pump pressure at 4.7 PSI.
5. Stop heater (see Operation, page 4).
6. Remove pressure gauge. Replace pres­sure gauge plug in filter end cover.
Pressure Gauge Plug
Figure 6 - Pressure Gauge Plug Removal
Pressure Gauge
Relief Valve
1. Remove upper shell (see Upper Shell Removal).
2. Use 1/8" Allen wrench to loosen set­screw which holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 4).
7. Place setscrew on flat of shaft. T ighten setscrew firmly (40-50 inch-pounds).
8. Replace fan guard and upper shell.
103685
Lint Filter
Air Output Filter
Figure 5 - Air Output, Air Intake, and Lint Filters
7
Figure 7 - Adjusting Pump Pressure
Continued
Page 8
70,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
SERVICE PROCEDURES
Continued
WARNING: Never service heater while it is plugged in, op­erating, or hot. Severe burns and electrical shock can occur.
FUEL FILTER
1. Remove 4 side cover screws using 5/16" nut-driver.
2. Remove side cover.
3. Pull upper fuel line off fuel filter neck.
4. Carefully pry bushing and fuel filter out of fuel tank.
5. W ash fuel filter with clean fuel and re­place in tank.
6. Attach upper fuel line to fuel filter neck.
7. Replace side cover.
Fuel Filter
Side Cover Upper Fuel Line
Figure 8 - Fuel Filter Removal
IGNITOR
1. Remove upper shell and fan guard (see page 7).
2. Remove fan (see page 7).
3. Remove 4 side cover screws with a 5/16" nut driver. Remove side cover (see Figure 8).
4. Disconnect ignitor wires (yellow) from ignition control assembly (see Figure
9). Pull the ignitor wires up through the hole in the lower shell.
5. Disconnect fuel line hose and air line hose. Remove photocell from photocell bracket (see Figure 9).
6. Remove combustion chamber. Stand combustion chamber on end with nozzle adapter bracket on top (see Fig­ure 10).
7. Remove ignitor screw with a 1/4" nut driver. Carefully remove ignitor from nozzle adapter bracket.
CAUTION: Do not bend or strike
ignitor element. Handle with care.
8. Carefully remove replacement ignitor from styrofoam packing.
9. Carefully guide ignitor into opening in nozzle adapter bracket. Do not strike ig­nitor element. Attach ignitor to nozzle adapter bracket with screw using a 1/4" nut driver (see Figure 10). T orque 8 to 15 in. lbs. Do not over torque.
10. Replace combustion chamber.
11. Route the ignitor wires back down through the hole in the lower shell. Connect wires to the ignition control assembly.
12. Replace side cover (see Figure 8).
13. Connect and route fuel line hose and air line hose to nozzle adapter (see Figure 9).
14. Replace photocell in photocell bracket. Route wires as shown in Figure 12, page 9.
15. Replace fan (see page 7).
16. Replace fan guard and upper shell (see page 7).
Combustion Chamber
Air Line Hose
Fuel Line Hose
Photocell Bracket
Photocell Assembly
Side Cover
Figure 9 - Disconnecting Ignitor Wires from Ignition Control Assembly
Nozzle Adapter Bracket
Ignitor
Ignitor Wires
Ignition Control Assembly
Ignitor Screw/ Washer Assembly
Ignitor
Ignitor
Photocell Bracket
Combustion Chamber
Figure 10 - Ignitor Replacement
Element
Nozzle Adapter Bracket
Nozzle Adapter Bracket Opening
IGNITION CONTROL ASSEMBLY
(Procedure for Replacing Fuse)
WARNING: High Voltage
1. Unplug heater
2. Remove side cover screws (4) using 5/16" nut-driver to expose ignition con­trol assembly.
3. Remove fuse cover.
4. Remove fuse from fuse clips.
5. Replace fuse with fuse of the same type and rating (GMA-10). Do not substi­tute a fuse with a higher current rating.
6. Replace fuse cover.
7. Replace side cover.
Fuse Clips
Figure 11 - Replacing Fuse
Fuse Cover
Fuse
8
103685
Page 9
OWNER’S MANUAL
SERVICE PROCEDURES
Continued
NOZZLE ASSEMBLY
1. Remove upper shell (see page 7).
2. Remove fan (see page 7).
3. Remove fuel and air line hoses from nozzle assembly (see Figure 12).
4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove (see Figure 13).
5. Place plastic hex-body into vise and lightly tighten.
6. Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench (see Figure 14).
7. Blow compressed air through face of nozzle. This will free any dirt in nozzle area.
8. Inspect nozzle seal for damage.
9. Replace nozzle into nozzle adapter un­til nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench (40-45 inch­pounds).
10. Attach nozzle assembly to burner strap.
11. Attach and route fuel and airline hoses to nozzle assembly as shown (see Fig­ure 12). Route photo cell wires as shown in Figure 12.
12. Replace fan (see page 7).
13. Replace fan guard and upper shell.
Combustion Chamber
Nozzle/ Adapter Assembly
Figure 13 - Removing Nozzle/Adapter Assembly
Nozzle Face
Nozzle Seal
Nozzle
Nozzle Adapter
Air Line Fitting
Figure 14 - Nozzle and Nozzle Adapter
Fuel Line Fitting
FUEL AND AIR LINE REPLACEMENT AND PROPER ROUTING
1. Remove upper shell (see Upper Shell Removal, page 7).
2. Remove side cover scr ews using 5/16" nut driver (see Figure 8, page 8).
3. Remove side cover.
4. Inspect fuel and air line hoses for cracks and/or holes. If fuel line hose is damaged, disconnect from nozzle adapter (see Fig­ure 12) and from fuel filter (see Fuel F il- ter, page 8). If air line hose is damaged, disconnect from nozzle adapter (see Fig­ure 12) and from barb fitting on pump end cover (see Figure 15).
5. Install new air and/or fuel line. Attach one end of air line hose to barb fitting on pump end cover (see Figure 15) and the other end to nozzle adapter (see Figure 12). Attach one end of fuel line hose to fuel filter (see Fuel Filter, pa ge
8) and the other end to nozzle adapter (see Figure 12). Route air and fuel line approximately as shown in Figure 12.
Note:
Route hoses as shown in Figure
12. Hoses are not to touch photocell bracket.
6. Replace side cover.
7. Replace upper shell and fan guard (see Upper Shell Removal, page 7).
Pump End Cover
Combustion Chamber
Burner Strap
Nozzle/ Adapter Assembly
Fuel Line
Air Line Hose
Figure 12 - Removing Air and Fuel Line Hoses
103685
Hose Photocell
Wires
Barb Fitting
Air Hose
Figure 15 - Air Hose to Barb FItting
Continued
9
Page 10
70,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
SERVICE PROCEDURES
Continued
PUMP ROTOR
(Procedure if Rotor is Binding)
1. Remove upper shell (see page 7).
2. Remove filter end cover screws using 5/16" nut-driver.
3. Remove filter end cover and air filters.
4. Remove pump plate screws using 5/16" nut-driver .
5. Remove pump plate.
6. Remove rotor, insert, and blades.
7. Check for debris in pump. If debris is found, blow out with compressed air.
8. Install insert and rotor.
9. Check gap on rotor. Adjust to .003"/ .004" if needed (see Figure 17).
Note:
Rotate rotor one full turn to in­sure the gap is .003"/.004" at tightest position. Adjust if needed.
10. Install blades, pump plate, air filters, and filter end cover.
11. Replace fan guard and upper shell.
12. Adjust pump pressure (see page 7).
Note:
If rotor is still binding, proceed
as follows.
13. Perform steps 1 through 6 above.
14. Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “figure 8” motion four times (see Fig­ure 18).
15. Reinstall insert and rotor.
16. Perform steps 10 through 12 above.
Blade
Pump Plate
Air Intake Filter
Filter End Cover
Insert
Rotor
Air Output
OR
Figure 16 - Rotor Location
Gap Adjusting Screw
Blade
Gap Adjusting Screw
Figure 17 - Gap Adjusting Screw Locations
Filter
PFA/P 056
Fan Guard
.003"/.004" Gap Measured With Feeler Gauge
Rotor
Sandpaper
REPLACEMENT PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni­cal Service Dept. at 1-800-323-5190.
When calling DESA International, have ready:
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. Parts Centrals are listed in the Authorized Service Center booklet supplied with heater.
When calling DESA International, have ready:
• model number of your heater
• the replacement part number
TECHNICAL
Figure 18 - Sanding Rotor
10
SERVICE
You may have further questions about op­eration or troubleshooting. If so, contact DESA International’s Technical Service Dept. at 1-800-323-5190.
You can also visit DESA International’s technical services web site at www.desatech.com.
103685
Page 11
OWNER’S MANUAL
SPECIFICATIONS
Output Rating (Btu/Hr) 70,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gal.) 5.0 Fuel Consumption (Gal. Per Hr.) .52 Electric Requirements 120 V/60 Hz Amperage (Normal Run) 2.8 Hot Air Output (CFM) 360 Motor RPM 3440 Motor HP 1/8 Shipping Weight
(Approximate Pounds) 36
Heater Weight without Fuel
(Approximate Pounds) 31
ACCESSORIES
Purchase accessories and parts from your nearest dealer or service center. If they can not supply these accessories or parts, either contact your nearest Parts Central or DESA International for referral information. Parts Centrals are listed in the Authorized Service Center booklet supplied with heater.
DESA International P.O. Box 90004 Bowling Green, KY 42102-9004 1-800-972-7879 Parts Department
WIRING DIAGRAM
Ignitor
Yellow
Power Plug
120V/60Hz
Green
Figure 19 - Wiring Diagram
Black
White
Photocell
A 008
IGNITION CONTROL ASSEMBLY/PHOTOCELL TESTER - HA1170
Special tool used to test the ignition control assembly and photocell.
Yellow Red
Motor
Ignitor Motor
Green
Ignition Control
Assembly
AC Hot (L1) AC Neutral (L2)
White
Blue Blue
STANDARD WHEELS AND HANDLE KIT - HA1206
Makes heater even more portable and con­venient. Easy to assemble.
Motor Return Ignitor
Photocell Photocell
AIR GAUGE KIT - HA1180
Special tool to check pump pressure.
103685
HEAVY DUTY WHEELS AND HANDLE KIT - HA1202
For heavy duty applications. Makes your heater even more portable and convenient.
11
THERMOSTAT KIT - HA1210
Keeps your building at the temperature you select day and night. Helps economize on fuel.
Page 12
70,000 Btu/Hr H.S.I. Series
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
9-2
9-1
9-3
9-4
9-5
17
18
19
20
21
22
23
24
25
26
27
28
29
30
34
35
36
32
33
31
PORTABLE FORCED AIR HEATERS
ILLUSTRATED PARTS BREAKDOWN
R70D B70D
12-18
Motor and Pump Assembly
12-1
12-2
12-17
12-16
12-4
12-5
12-6
12-13
12-3
12-15
12-14
12-12
12-7
12-8
12-9
12-10
12-11
12
103685
Page 13
OWNER’S MANUAL
PARTS LIST
R70D
This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
B70D
KEY PART NO. NUMBER DESCRIPTION QTY.
1 M51104-01 Handle 1 2 098511-36 Upper Shell (R70D) 1
098511-54 Upper Shell (B70D) 1 3 M11084-29 Screw, #10-16 x 3/4" 2 4 100647-01 Screw, #10-16 x 1/2" 6 5 098512-51 Combustion Chamber 1 6 M10908-2 Screw, #6-32 x 3/8" 2 7 103154-03 Photocell Bracket 1 8 M16656-23 Photocell Assembly 1 9 Burner Head Assembly 1 9-1 100735-18 Nozzle Assembly 1 9-2 102548-03 Ignitor Kit 1 9-3 104056-01 Nozzle Adapter 1 9-4 102336-01 Nozzle Adapter Bracket 1 9-5 104023-01 Screw/Washer Assembly 1 10 M11084-26 Screw, #10-16 x 3/8" 2 11 M29678 Fan 1 12 Motor and Pump Assembly 1 12-1 102001-20 Motor 1 12-2 079975-02 Pump Body 1 12-3 M22009** Insert 1 12-4 M22456-1** Rotor 1 12-5 M29608 Pump End Cover 1 12-6 M29632 Lint Filter 1 12-7 M29633 Intake Filter 1 12-8 M29609 Filter End Cover 1 12-9 M12461-31 Screw, #10-32 x 1" 3 12-10 M27694 Adjusting Screw 1 12-11 M10993-1 Pressure Relief Spring 1 12-12 M22997 Plug 1 12-13 M8940 Steel Ball, 1/4" Diameter 1 12-14 M29612-01 Output Filter 1 12-15 M12461-31 Screw, #10-32 x 1" 6 12-16 103676-01 Nylon Elbow, 90° 1
KEY PART NO. NUMBER DESCRIPTION QTY.
12-17 M8643** Blade 4 12-18 FHPF3-5C Screw, #10-32 x 5/8" 2 13 M51105-01 Fan Guard 1 14 098219-31 Power Cord 1 15 M11143-1 Strain Relief Bushing 1 16 NTC-4C Hex Lock Nut, 1/4-20 2 17 M11084-26 Screw, #10-16 x 3/8" 4 18 M50631 Rubber Bumper 2 19 097461-03AA Side Cover 1 20 101205-01 Motor Bracket 1 21 M30865-02 Bushing 2 22 M11271-8 Clip Nut 6 23 M50104-02 Bushing 1 24 M11084-26 Screw, #10-16 x 3/8" 6 25 M10908-14 Screw, #8-32 x 3/8" 1 26 098511-18 Lower Shell (R70D) 1
098511-12 Lower Shell (B70D) 1 27 M50814-06 Rubber Airline 1 28 079973-01 Fuel Line 1 29 M50876-05 Fuel Filter (with bushing) 1 30 M10990-3 Rubber Bushing 1 31 101695-01 Button Plug 1 32 102349-01 PCB Support 5 33 104068-02 Ignition Control Assembly 1 34 097702-01 Fuel Cap (Includes Gasket) 1 35 098513-62 Fuel Tank 1 36 M51108-01 Shell Heat-Shield 1
PARTS AVAILABLE - NOT SHOWN
097204-03 Tradename Decal (R70D) 2
097646-02 Tradename Decal (B70D) 2
098493-01 General Information Decal 1
103814-01 Wire Tie 1
Not available as an assembly ** Included in Rotor Kit (part No. HA3004)
Included in Filter Kit (Part No. HA3014) Included in Pump Adjustment Kit (Part
No. HA3020)
103685
13
Page 14
WARRANTY AND REPAIR SERVICE
LIMITED WARRANTY
DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.
This warranty covers only the cost of parts and labor required to restore the product to proper operating condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.
Warranty service is available only through authorized dealers and service centers. This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear,
alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.
THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUD­ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DESA International assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.
WARRANTY SERVICE
Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without charge.
REPAIR SERVICE
Return the heater to your nearest authorized service center. Each Service Center is independently owned and operated. Repairs not covered by the warranty will be billed at standard prices. When writing for information regarding your heater, be sure to include the model number and serial number as shown on the model plate. We reserve the right to amend these specifications at any time without notice.
Illustrated parts lists can be obtained free of charge. Send a self addressed stamped envelope to the address listed below. List the heater model number and the date located in the lower right corner of this page. A service manual may be purchased from the address listed below. Send a check for $5.00 payable to DESA International.
KEEP THIS WARRANTY
Model No. Serial No. Date of Purchase
(To be filled in by purchaser)
Corporate Headquarters
2701 Industrial Drive P.O. Box 90004
Bowling Green, KY 42102-9004 www.desatech.com
103685 01
NOT A UPC
For information, write: DESA International, P.O. Box 90004
Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department
When writing, always include model number and serial number.
103685-01 Rev. E 02/99
Loading...