IMPORTANT
Read and understand this manual before assembling, starting, or servicing
heater. Improper use of heater can cause serious injury. Keep this manual
for future reference.
Warranty and Repair Service ........................................................ Back Cover
SAFETY
INFORMATION
2
WARNINGS
IMPORTANT: Read this Owner’s Manual carefully and completely
before trying to assemble, operate, or service this heater. Improper
use of this heater can cause serious injury or death from burns, fire,
explosion, electrical shock, and carbon monoxide poisoning.
DANGER
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, and/or nausea. If you have these
signs, the heater may not be working properly. Get fresh air at once! Have
heater serviced. Some people are more affected by carbon monoxide than others.
These include pregnant women, persons with heart or lung disease or anemia,
those under the influence of alcohol, and those at high altitudes.
Make certain you read and understand all Warnings. Keep this manual for
reference. It is your guide to safe and proper operation of this heater.
099176
SAFETY
INFORMATION
Continued
WARNINGS
• Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use
gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
• Fueling
a) Personnel involved with fueling shall be qualified and thoroughly familiar with
the manufacturer's instructions and applicable federal, state, and local regula-
tions regarding the safe fueling of heating units.
b) Only the type of fuel specified on the heater's data plate shall be used.
c) All flame, including the pilot light, if any, shall be extinguished and the heater
allowed to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-line connections shall be inspected for leaks.
Any leaks shall be repaired prior to returning the heater to service.
e) At no time shall more than one day's supply of heater fuel be stored inside a
building in the vicinity of the heater. Bulk fuel storage shall be outside the struc-
ture.
f) All fuel storage shall be located a minimum of 25 feet from heaters, torches,
welding equipment, and similar sources of ignition (exception: the fuel reservoir
integral with the heater unit).
g) Whenever possible, fuel storage shall be confined to areas where floor penetra-
tions do not permit fuel to drip onto or be ignited by a fire at lower elevation.
h) Fuel storage shall be in accordance with the federal, state, or local authority hav-
ing jurisdiction.
• Never use heater where gasoline, paint thinner, or other highly flammable vapors are
present.
• Follow all local ordinances and codes when using heater.
• Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials
shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet. It is further recommended that these enclosure
materials be of a fire retardant nature. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to
wind action.
• Use only in well-vented areas. Before using heater, provide at least a three-squarefoot opening of fresh, outside air for each 100,000 BTU/Hr of rating. This heater
produces carbon monoxide, which is listed by the State of California as a reproductive
toxin under Proposition 65.
• Use only in places free of flammable vapors or high dust content.
• Use only the electrical voltage and frequency specified on model plate.
• Use only a three-prong, grounded extension cord.
• Minimum heater clearances from combustibles:
Outlet: 8 Ft.Sides: 4 Ft.Top: 4 Ft.Rear: 4 Ft.
• Locate heater on a stable and level surface if heater is hot or running or a fire may
occur.
• When moving or storing heater, keep heater in a level position or fuel spillage may
occur.
• Keep children and animals away from heater.
• Unplug heater when not in use.
• When used with thermostat, heater may start anytime.
• Never use heater in living or sleeping areas.
• Never block air inlet (rear) or air outlet (front) of heater.
• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
• Never attach duct work to front or rear of heater.
(Continued)
099176
3
PRODUCT
IDENTIFICATION
Hot Air Outlet
Handle
Upper Shell
Lower Shell
Fuel Tank
Side Cover
Hot Air
Outlet
Lower
Shell
Flame-Out Control
Reset Button
Power Cord
35/50/70,000 BTU/HR DOMESTIC
Figure 1 - 35/50/55/70,000 BTU/Hr Models
Fan Guard
Air Filter
End Cover
Fuel Cap
PFA/PV 042
Upper Shell
Fuel Cap
Side Cover
100,000 BTU/HR DOMESTIC
Figure 2 - 100/110/150,000 BTU/Hr Models
Flame-Out
Control Reset
PFA/PV 043
Button
Fan Guard
Fuel Tank
Power Cord
4
099176
UNPACKING
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If heater is damaged, promptly inform dealer
where you bought heater.
ASSEMBLY
(For 100,000, 110,000, and
150,000 BTU/Hr Models Only)
These models are furnished with wheels and a front handle. Some models are
furnished with a rear handle also. Wheels, handle(s), and the mounting hardware
are found in the shipping carton.
Tools Needed
• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support frame. Install wheels on axle.
IMPORTANT:
wheel support frame (see Figure 3).
2. Place cap nuts on axle ends. Gently tap with hammer to secure.
3. Place heater on wheel support frame. Make sure air inlet end (rear) of heater is
over wheels. Line up holes on fuel tank flange with holes on wheel support
frame.
4. Place front handle (and rear handle if provided) on top of fuel tank flange.
Insert screws through handle(s), fuel tank flange, and wheel support frame.
Attach nut finger tight after each screw is inserted.
5. After all screws are inserted, tighten nuts firmly.
When installing wheels, point extended hub of wheels toward
Front
Handle
Hot Air
Outlet
Fuel
Tank
Flange
Wheel
Support
Frame
Wheel
Cap Nut
Figure 3 - Wheel and Handle Assembly, 100/110/150,000 BTU/Hr Models Only
ASSEMBLY
Screw
Nut
Axle
Rear
Handle
Air
Inlet
Extended
Hub
PFA/PV 018
099176
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.