(1) General precautions
Thank you for purchasing this product. This instruction sheet provides information about the DOP-100
series HMI. Before using this product, please read through this instruction sheet carefully to ensure the
correct use of the product. Please keep this sheet handy for quick reference whenever needed. Before
finishing reading this sheet, please follow the instructions below:
Install the product in an indoor location, which is free of vapor, corrosive and inflammable gas and
liquids.
Please refer to the wiring diagram when connecting the wires.
Ensure your HMI is correctly grounded. The grounding method must comply with the national
electrical standard (please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble the HMI or change the wiring when power is on.
Do not touch the power supply when power is on, or it may cause electric shock.
When the HMI displays a low power notification and requires a battery change, please contact
your local distributor or Delta Customer Service Center for the replacement. Do not change the
batteries by yourself.
This product can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
Cleaning method: please use a dry cloth to clean the product.
This product must be used at an altitude below 2,000 m.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
For repair and maintenance, please contact Delta Electronics, Inc. Address: No.18, Xinglong Rd.,
Taoyuan City, Taiwan. TEL: +886-3-3626301.
If you have any inquiry during operation, please contact our local distributors or Delta sales
representatives. The content of this instruction sheet may be revised without prior notice. Please consult
our distributors or download the latest version at Delta’s website (http://www.delta.com.tw/ia).
(2) Communication port pin assignment
DOP-107EG COM1 port
COM Port Pin
DOP-107EG COM2 port
COM Port Pin
Note: mark “-” means connection is not required.
1 - - D+ - - TXD+
2 RXD - - - RXD 3 TXD - - - TXD 4 - D+ - D+ - RXD+
5 GND GND GND
6 - - D- - - TXD7 RTS - - - RTS 8 CTS - - - CTS 9 - D- - D- - RXD-
COM2 COM3 COM2 COM3 COM2 COM3
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422
1 2 RXD
3 TXD
4 5 GND
6 7 RTS
8 CTS
9 -
MODE1 MODE2 MODE3
MODE1
RS-232
(3) Description of each part
DOP-107EG (front view)
DOP-107EG (rear view)
A USB Host B USB Slave
Power input terminal
C
(24 AWG wire min.)
E COM1 F
(4) Mounting dimensions
DOP-107EG
Operation temperature: 0oC to 50oC (32oF to 122oF)
Storage temperature: -20
A Operation / display area
D COM2 / COM3
Network Port(LAN)
o
C to +60oC (-4oF to 140oF)
Unit: mm (inch)
(5) Installation and wiring
Precautions:
Incorrect installation may result in malfunction.
To ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the
adjacent objects or walls.
This product should be used on a case / platform which conforms to enclosure Type 4X standard (for
indoor use only).
The maximum panel thickness for mounting must be no greater than 5 mm.
Installation steps:
Step 1:
Put the waterproof gasket into the HMI and
then insert the HMI into the panel cutout.
Step 3:
Tighten the screws with the torque less than
0.5 N-M / 0.7 N-M to avoid damage to the
plastic case.
DOP-107BG torque: 6.17 lb-inch (0.7N-M)
Wiring:
Type
Solid
Stranded
Please refer to the following diagram when wiring the power connector. The temperature
rating of the cable must be greater than 75
Wire gauge (AWG) Stripped length To r q ue
24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
Step 2:
Place the fasteners into the slots and tighten
the screws until reaching the panel cutouts.
Step 4:
For heat dissipation, please keep a minimum
clearance of 60 mm on the rear of the HMI.
o
C (167oF).

(6) Hardware specifications
Model
Panel type
Resolution
Display range
CPU
RAM
Backlight
Brightness
LED backlight (half-life under room temperature 25oC > 20,000 hours)
Display
Flash ROM 256 Mbytes
DOP-107EG
7" TFT LCD (65535 colors)
800 x 600 pixels
141.00 x 105.75 mm
450 cd/m² (Typ.)
ARM Cortex-A8 (800 MHz)
256 Mbytes
*1
Touchscreen
Buzzer
Network interface
4-wire resistive touchscreen > 10,000,000 operated
Multi-tone frequency (2 K – 4 KHz) / 80 dB
10/100 Mbps Auto sensing (with built-in isolated power circuit)
USB 1 USB slave Ver 2.0; 1 USB host Ver 2.0
SD SD * 1
COM1 RS-232 (supporting flow control) *2
Serial
communication
port
COM2 RS-232 (supporting flow control) / RS-485*2
COM3 RS-422 / RS-485*2
Auxiliary function key N/A
Calendar Built-in
Cooling method Natural cooling
Approvals
CE / UL (please use shielding network cable and magnetic ring with the
filter of 300 ohm / 100 MHz)
Panel waterproof level IP65 / NEMA4
DC +24 V (-15% to +15%) (please use an isolated power supply)
Operation voltage*2
Supplied by Class 2 or SELV circuit (isolated from MAINS
by double insulation)
Leakage current
500 VAC for 1 minute (between DC24V terminal and FG terminal)
Power consumption*2 8.4 W (Max)*3
*2
Backup battery 3V lithium battery CR2032 × 1
Backup battery life
(subject to operation temperature and condition)
About 3 years or more at 25oC
Operation temperature 0oC to 50oC (32oF to 122oF)
Storage temperature -20oC to +60oC (-4oF to 140oF)
Operating environment
Vibration resistance
Shock resistance
Dimension
(W) x (H) x (D) mm
Mounting dimension
(W) x (H) mm
10% to 90% RH [0oC to 40oC], 10% to 55% RH [41oC to 50oC];
pollution degree: 2
Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with amplitude
3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G
Conforms to IEC60068-2-27: 11 ms, 15 G Peak,
in X, Y, Z directions each for 6 times
184 x 144 x 50
172.4 x 132.4
Weight Approx. 800 g
Note:
1. The half-life of the back light is defined as the maximum luminance being reduced by 50% when the
maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the
room temperature of 25
2. The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute.
3. The HMI power consumption is the power consumed when the HMI is not connecting with other
peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power
supply is 1.5 to 2 times of the specified power consumption.
4. Isolated power supply is recommended.
5. For DOPSoft programming software for DOP-100 series and the user manual, you can download them
at http://www.delta.com.tw/ia.
6. DOP-100 series can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
o
C with ambient humidity.