Delta Electronics CTA User Manual

2006-12-08
Tachometer function indicator
MODE
MODE
MODE
MODE
SET1 and
MODE
MODE
MODE
CTA
2
3
4
5
6
1
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
Power signal
Signal On Delay 1
Output signal
Signal On Delay 2
Power signal
Start signal
Pause signal
Clear signal
Signal Off Delay
Power signal
Output signal
Signal On
Output signal
Power On Delay
Output signal
Power On Delay Hold
Output signal
tim er outp ut set as 0
Output signal
timer output not set as 0
Output signal
Repeat Cycle Hold
Timer output set as 0
Output signal
RCYH timer output not set as 0
Output signal
Repeat Cycle 2
Signal Cumulate
Output signal
Output signal
Instruction Sheet
5011646001-CTE1
¾ DANGER! Caution! Electric Shock! ¾ When the power is on, DO NOT touch the AC terminals in case an electric shock may occur. ¾ Make sure the power is disconnected when you check the unit inside.
¾ CTA series is an OPEN-TYPE device. They are intended for installation completely within an overall panel and are for use
in counting or timing application. If it will cause serious injury to workers or damage on other equipments when used in a dangerous environment, please make sure it is installed in an automatic safety protection device.
1.
Precaution
1. Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, width 7.0mm), hole (diameter
3.2mm). Screw size: M3x6.5 (with 6.8x6.8 square washer). Recommended tightening torque: 0.4 N.m (4kgf.cm). Applicable wire: solid/twisted wire of 2mm
2
, 12AWG to 24 AWG. Please be sure to tighten them properly.
2. Prevent dust or metallic debris from falling into the device and cause malfunctions.
3. DO NOT modify or uninstall the device.
4. DO NOT use empty terminals.
5. Make sure the wires are correctly connected to proper terminals.
6. Keep away from high-voltage and high-frequency environment during installation in case of interference.
7. Prevent using the device in premises which contain: Dust or corrosive gas High humidity High radiation Vibration and shock
8. CTA series is an open-type device. Make sure to install it in an enclosure to prevent dust, humidity in case of an electric
shock.
9. Please make sure the power cables and signal device are installed correctly before switching on the power; otherwise
serious damage may occur.
10. DO NOT touch the terminals or repair the device when the power is on; otherwise an electric shock may occur.
11. Please wait for one minute after the power is switched off to allow the capacitor to discharge and DO NOT touch the
internal wiring within this period.
12. Use dry cloth to clean the device. DO NOT use acid or alkaline liquid to clean the device.
2. Display, Indicators and Keys
Reset 2 indicator
Reset 1 indicator
Key protect 2 indicator
Key protect 1 indicator
Output 2 indicator Output 1 indicator
Special function indicator
Lock key
Reset key
Mode and number shift key
PV(Present Value) display
SV(Set Value) display
Timer function indicator
Counter function indicator
Up/Down key
LCD Display and indicators
RST 1/2 Light on when reset signal is detected BATCH “Batch Counting Mode” in Counter and Tachometer function
K/P 1/2 Light on when key-protected mode is enabled SET 1 2 SV1, SV2 display
OUT 1/2
Light on when output is executing TAC Light on when Tachometer function is executing
H M S
Hour, minute, second, unit of timer, displayed
CNT Light on when Counter function is executing
in Timer function
TOTAL
“Total Counting Mode” in Counter and
TMR Light on when Timer function is executing
Tachometer function
Key Operation
Increase and decrease SV or change parameter settings. Left move 1 digit of the selected digit. The indicator of the selected digit will flash. Save the set parameters or switch among functions.
LOCK
Prevent settings from being changed. Key-protected mode still works after the power is switched off. Press
LOCK to enter key-protected mode. In non-key-protected status, press LOCK to enter Lock 1. In Lock 1, press LOCK again to enter Lock 2. Press
and at the same time to disable key-protected mode. (Lock 1)
disables the functions of all keys. (Lock 2) allows users to change SV and functions of RESET remain.
LOCK only functions in non-key-protected status.
RESET
Clear and reset PV.
Modes: Operation Mode and Configuration Mode
Operation
Configuration
When the power is on, the timer/counter/tachometer is in the operation mode. Press to change SV, or
to make change on a desired digit. The indicator of the selected digit will flash. After the change is made,
press
to save the setting. If SV or parameters are not changed, press
once to switch between
SET2.
Press among parameters. To return to operation mode, press
in operation mode for more than 3 seconds to enter configuration mode. Press
for more than 3 seconds.
once to switch
3. Ordering Information
n Product name CTA: Delta Counter/Timer/Tachometer A series q Preset stage 0: 2 preset stage
o Panel size 4: 48mm x 48mm 1/16DIN r Communication 0: none
p Output 2 0: NPN; 1: Relay s Power supply A: AC 100~240V
4.
Specification
Power input AC 100~240V, 50/60Hz Input voltage range 85% to 110%, rated voltage Power consumption Less than 10VA
External power supply 12Vdc ±10%, 100mA
Display Double-line, 6-digit negative transmissive LCD display
Input signal
Output 1
Output 2
Non-voltage input (NPN): ON impedance 1K ohm max. ON residual voltage: 2V max. Voltage input (PNP): High level: 4.5 to 30Vdc, Low level: 0 to 2Vdc Relay: SPST max.250Vac, 5A (resistance load) Transistor: NPN open collector. When 100mA /30Vdc, residual voltage=1.5Vdc max. Relay: SPDT max.250Vac, 5A (resistance load) Transistor: NPN open collector. When 100mA /30Vdc, residual voltage=1.5Vdc max.
Dielectric strength 2000Vac 50/60 Hz for 1 minute
Vibration resistance Without damage: 10~55Hz, amplitude=0.75mm, 3 axes for 2 hours
Shock resistance Without damage: drop 4 times, 300m/s2, 3 edges, 6 surfaces and 1 corner
Ambient temperature 0 oC to +50 oC
Storage temperature -20 oC to +65 oC
Altitude 2000m or less
Ambient humidity 35% to 85% RH (non-condensing)
Pollution degree Degree 2
5.
Parameters in Configuration Mode
Timer
Select a function
MODE
Setup Timer function, (counting up or down)
MODE
Select output mode of Timer
MODE
Setup the displayed unit of timer
MODE
Setup the pulse width of output 1
MODE
Reset min. pulse width
MODE
Select input type (PNP or NPN)
MODE
Counter
Select a function
MODE
Back to
“select a
function”
Select counting modes
Select input type (PNP or NPN)
Setup input mode of Counter
Reset min.
MODE
pulse width
Setup output mode of Counter (not dual output)
Save data or
MODE
not while switching off power
Setup dual output counting mode (dual
MODE
output)
Setup pre-scale value
Setup counting speed
MODE
Setup the decimal point
Setup the pulse width of output 1
MODE
Setup the pulse width of output 2
Tachometer
Select a function
Back to “select a
function”
MODE
Setup output mode of Tachometer
Select input type (PNP or NPN)
MODE
Setup counting speed
Reset min. pulse width
Setup the decimal point
MODE
Setup the average of input data
Setup pre-scale value
MODE
!
Setup the delay time while switching on power
Timer + Counter Mixed
MODE
Setup output mode of timer
Select a function
MODE
Setup Timer function, (counting up or down)
Select
Back to
“select a
function”
input type (PNP or NPN)
6.
Timer Function
There are counting up/down modes, several counting units and output modes to choose from in timer function.
Select counting up or counting down
Setup the counting unit of the timer.
sec 0.01~9999.99 sec 0.1~99999.9 sec 1~999999 min,sec 0.01~9959.99 min,sec 0.1~99959.9 min 0.1~99999.9 min 1~999999 hr,min,sec 1~995959 hr,min 1~999959 hr 1~999999
MODE
Setup the displayed unit of timer
Reset min. pulse width
MODE
Setup input mode of Counter
MODE
Save data or not while switching off power
Setup output mode of Counter (not dual output)
MODE
Setup pre-scale value
Setup counting speed
Setup the decimal point
Setup the output time of timer, from 0 to 99.99 secs. 0= Hold output Setup output modes
A unit = 10ms. Max. counting = 9999.99 secs. A unit = 0.1sec. Max. counting = 99999.9 secs. A unit = 1 sec. Max. counting = 999999 secs. A unit = 0.01 sec. Max. counting = 5999.99 secs. A unit = 0.1 sec. Max. counting = 59999.9 secs. A unit = 0.1 min. Max. counting = 99999.9 mins. A unit = 1 min. Max. counting = 999999 mins. A unit = 1 sec. Max. counting = 359999 secs (100hr) A unit = 1 min. Max. counting = 35999999 secs (10000hr) A unit = 1 hr. Max. counting = 999999 hrs
MODE
Back to
“select a
function”
MODE
MODE
Setup the pulse width of output 1
MODE
Setup the pulse width of output 2
Start signal
Pause signal
Clear signal
Output signal
Down
Output signal
Up
Down
Power signal
Start signal
Pause signal
Clear signal
Up
Down
Power signal
Start signal
Pause signal
Clear signal
SV
Up
SV
Down
Power signal
Start signal
Pause signal
Clear signal
Up
Down
Power signal
Start signal
Pause signal
Clear signal
SV1
SV2
Up
SV1
Down
SV2
Power signal
Start signal
Pause signal
Clear signal
SV1
SV2
Up
0
SV1
Down
SV2
0
Power signal
Start signal
Pause signal
Clear signal
t
SV
Up
0
SV
0
t
Up
Down
tt
SV
0
SV
0
Start signal
Pause signal
Clear signal
SV
0
SV
0
t
tt
SV
0
SV
0
0
0
Repeat Cycle
SV
0
SV
0
0
0
Up
Down
Power signal
Start signal
Pause signal
Clear signal
Up
Down
Power signal
Start signal
Pause signal
Clear signal
SV
Up
SV
Down
Power signal
Start signal
Pause signal
Clear signal
Up
Down
Power signal
Start signal
Pause signal
Clear signal
Output signal
Up
Down
SV
0
SV
0
tt t
SV
0
SV
0
tt t
Repeat Cycle
tt
SV
0
SV
0
SV
0
SV
0
t
t
Signal Twin ON-Start
Power signal
Start signal
Pause signal
Clear signal
SV1 SV2
Up
SV1
Down
SV2
0
0
Signal Twin OFF-Start
CP1: Counter input prohibited CP2: Counter input
Note : has to be l arger than width of min. Input signal
Prohibit
A
A
n
n-2
n-1
n-4
n-3
CP1
CP2
Present
Valu e
CP1: Counter input CP2: Counter input prohibited
Note : has to be l arger than width of min. Input signal
A
A
Prohibit
A
n
n-1
n-2
n-3
n-4
n-5
CP1
CP20Present
Valu e
CP1: Counter input prohibited CP2 : Count er inpu t
Note : has to be l arger than width of min. Input signal
A
Note : has to be l arger t han width of 1/2 min. input signal.
0
utput 2
utput 2 (pulse) executes
T
T
TTTTT
T
999999
TTTTT
T
T
T
TTTTTTTTTTTTTTTTTTTTT
T
Input mode
Up/Down A, B, C
999999
Output
setting
Input mode
Up/Down A, B, C
RESET
RESET
RESET
setting
Up/Down A, B, C
Measurement value
Measurement value
OUT1 set value : OUT1 ON
OUT2 set v alue : O UT2 ON
OUT 2 set va lue
Measurement value
Measurement value
OUT1 set value : OUT1 ON
Measurement value
OUT2 set v alue : O UT2 ON
download the most updated version at
http://www.delta.com.tw/industrialautomation
7.
Counter Function
Counter functions include 1-stage counting, 2-stage counting, batch counting, total counting and dual counting.
1-stage Only 1 SV is allowed. See “output modes of counter”. 2-stage 2 SVs, 2 PVs are allowed. See “output modes of counter”.
Batch Apart from the counting of PV and SV, when PV=SV, the batch counting adds 1 and clear PV as 0 for
recounting till the batch counting equals batch SV.
Total Total counting adds up all the counting values till they reach SV for output. Dual CP1 and CP2 can be independent counters, but the counting speed can only reach 5kHz. CP1 and CP2
can execute addition
or subtraction .
Command counting up/down UD_A
Input modes of counter
Counting up
Counting down
Individual Quadrature
Command
Individual counting up/down
Counting up
CP1: Counter input CP2: Counter input prohibited
H
CP1
L
H
CP2
L
Present Valu e
0
A
Note : has to be l arger than width of min. Input signal
H
CP1
L
H
CP2
L
Present Valu e
0
A
A
1
0
1
0
Prohibit
2
A
Prohibit
2
A
4
3
A
4
3
Counting down
5
H L
H L
0
H L
H L
UD_B
Quadrature input UD_C
CP1
CP2
Present Valu e
H L
B B B B
H L
3
2
11
0
0
B
2
Output modes of counter :
The output of SV can be 1-stage or 2-stage. When the output is set as 1-stage, Output 2 will be the same as the Output 1. The output modes include: F, N, C, R, K, P, Q, A, S, T, D
F When PV reaches SV, output is enabled but counting continues. Recounting starts after reset signal is over.
Output 2 remains.
N When PV reaches SV, output is enabled but counting stops. Recounting starts after reset signal is over. Output 2
remains.
C When PV reaches SV, recounting executes automatically. Output 2 is pulse output. Output 1 remains till O
is over.
R When PV reaches SV, counting stops till Output 2 (pulse) is over for recounting. Output 1 remains till Output 2 is
over.
K When PV reaches SV, output is enabled but counting continues. Recounting starts after reset signal is over.
P When PV reaches SV, output is enabled and recounting is automatically executed. But display of counting
remains till Output 2 (pulse) is over.
Q When PV reaches SV, output is enabled but the counting continues. Recounting starts after Output 2 (pulse) is
over.
A When PV reaches SV, output is enabled but the counting stops. Recounting starts and O
after reset signal is over.
S When PV SV1, Output 1 is enabled. When PV SV2, Output 2 is enabled
T When PV SV1, Output 1 is enabled. When PV SV2, Output 2 is enabled.
D When SV=PV, output is enabled but counting continues. Addition and subtraction modes are valid.
The time of Output 1 and Output 2 (pulse) can be setup separately, ranging from 0.01 to 99.99 secs. Recounting refers to counting up or addition/subtraction counting starting from 0 and counting down starting from SV. The counting range: -99999~999999. The counting will restart from 0 if the counting exceeds the range.
Output mode setting
Up Down
F
RESET
999999
SV2
SV1
0
TT
OUT1
OUT2
RESET
N
999999
SV2
SV1
0
TT
OUT1
OUT2
RESET
C
999999
SV2
SV1
0
OUT1
OUT2
R
RESET
SV2
SV1
0
OUT1
OUT2
mode
Up
K
RESET
999999
SV2
SV1
0
TT
OUT1
OUT2
P
RESET
999999
SV2
SV1
0
TT TT
OUT1
OUT2
Q
RESET
999999
SV2
SV1
0
TT TT TTTTTT
OUT1
OUT2
A
RESET
SV2
SV1
0
TT
OUT1
OUT2
Down
TT
T
T
TT
TTTT
T
T
T
TT
TTT
T
TTT
Input mode
S
Output mode
999999
SV2
SV1
0
OUT1
OUT2
T
999999
SV2
SV1
0
OUT1
OUT2
D
999999
SV2
SV1
0
OUT1
OUT2
Save the data before power off : When is set, the current PV will be saved. When is displayed, the
PV will be cleared.
Pre-scale function : When conducting unit conversion, PV = PV x PreScale value, ranging from 0.001 to 99.999.
8.
Tachometer Function
Measuring Rotation speed: Measuring pulse width and determining current frequency Output methods: Lo-Lo, Lo-Hi, Hi-Lo, Hi-Hi
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
Measurement value
OUT2 set value
Measurement value
OUT1 set value
OUT1
OUT2
Measurement value OUT1 set val ue : OU T1 ON Measurement value
OUT1 set value : OUT1 ON OUT2 set value : OUT2 ON
OUT2 set valu e : OUT 2 ON
(LO-LO)
(HI-LO)
OUT2 set value
OUT1 set value
OUT1
OUT2
Measurement value
OUT 1 set va lue
OUT1
OUT2
Delay time after switching on the power : The tachometer will start to run when the set delay time is due after the
power is switched on. (Range of delay time: 0.1~99.9 secs.)
Setup average value of input filter
: Range for obtaining average (n = 0 ~ 3). This parameter obtains the average of 2
input data for more stable output value.
9.
Timer + Counter Mixed Function
In Timer + Counter function, SV1, PV1 and Output 1 are for Timer; SV2, PV2 and Output2 are for Counter. DIP switch is disabled. All timer and counter functions remain except
RCY2, SCON, STON, STOFF in output mode of Timer function Command up/down, Individual up/down, quadrature counting in input mode, S, T, D in output mode of Counter function
Only 1-stage counting in Counter function is available.
10.
Easy DIP Switch Setup
Users can use DIP switch to setup parameters. When DIP is switched to ON, the corresponding parameters can only be read, not changed.
SW
Reset pulse width
8
ON: 1ms, OFF: 20ms Input type
7
ON: PNP OFF: NPN N/A Unit of Timer
6
Counting speed
5
ON: 10K CPS OFF: 30 CPS Output mode of counter
4
See Table 2
Output mode of counter
3
See Table 2 Input mode of counter
2
ON: counting down OFF: counting up ON: Enable DIP
1
OFF: Disable DIP
Counter Timer Tachometer
Reset pulse width ON: 1ms, OFF: 20ms Unit of Timer
See Table 1
Reset pulse width ON: 1ms, OFF: 20ms Input type ON: PNP OFF: NPN
N/A See Table 1 Unit of Timer See Table 1 Output mode of Timer
See Table 2
Output mode of Timer
See Table 2
Time counting up/down
Counting speed
ON: 10KHz OFF: 30Hz
Output mode of Tachometer
See Table 2
Output mode of Tachometer
See Table 2
N/A ON: down OFF: up ON: Enable DIP OFF: Disable DIP
ON: Enable DIP
OFF: Disable DIP
(LO-HI)
(HI-HI)
SW5 SW6 SW7 Displayed unit
OFF OFF OFF 0.01 sec
ON OFF OFF 0.1 sec
OFF ON OFF 1 sec
ON ON OFF min, 0.01 sec
OFF OFF ON min, 0.1 sec
ON OFF ON 0.1 min
OFF ON ON Min
ON ON ON hr, min, sec
SW3 SW4
Counter
OFF OFF F Signal ON Delay 1 Lo-Lo
ON OFF N Signal ON Delay 2 Lo-Hi
OFF ON C Signal OFF Delay Hi-Lo
ON ON R Signal ON Hi-Hi
Tab le 2
Output Mode Configuration
Timer Tac hometer
Tab le 1
11.
Terminal Definition
Input connections
CTA4 series
Multi-function input pin
Counter Timer Tachometer Timer + Counter
CP1 CP1 CP1
CP2 Gate Gate Reset1 Reset1 Reset1 Reset1 Reset2 Start Start
12.
Dimension & Panel Cutout
CTA4 series
n
13.
How to Mount
Step-1. Insert the controller through the panel cutout. Step-2.
Insert the mounting bracket into the mounting groove at the top and bottom of the controller and push the mounting bracket forward until the bracket stops at panel wall.
Step-3.
Insert and tighten screws on bracket to secure the controller in place.