2007-10-12
5011644101-PDT1
Profibus Communication Module (CME-PD01) Instruction Sheet
Profibus is a registered trademark of Profibus International.
Please thoroughly read and understand the following contents to ensure correct use before operation.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the most updated version at http://www.delta.com.tw/industrialautomation
A. Panel Appearance
NET LEDAddress Switches
SP LED
C. Parameters Setting in VFD-E
Baud Rate 9600 Pr.09.01=1
ADDH
ADDL
SPNET
CME-PD01
RTU 8, N, 2 Pr.09.04=3
Freq. Source Pr.02.00=3
Command Source Pr.02.01=3
D. Power Supply
The power of CME-PD01 is supplied from VFD-E. Please
connect VFD-E to CME-PD01 by using 8 pins RJ-45 cable,
RS-485 (RJ45)
1: Reserv ed
2: EV
3: GND
4: SG-
5: SG+
6: Reserved
7: Reserv ed
8: Reserved
which is packed together with CME-PD01. After connection
is completed, CME-PD01 is powered whenever power is
applied to VFD-E.
E. PROFIBUS Address
VFD-E
Profibus-DP
Interface (DB9)
1. SP LED: Indicating the connection status between
VFD-E and CME-PD01.
2. NET LED: Indicating the connection status between
CME-PD01 and PROFIBUS-DP.
3. Address Switches: Setting the address of
CME-PD01 on PROFIBUS-DP network.
4. RS-485 Interface (RJ45): Connecting to VFD-E, and
supply power to CME-PD01.
5. PROFIBUS-DP Interface (DB9): 9-PIN connector
that connects to PROFIBUS-DP network.
6. Extended Socket: 4-PIN socket that connects to
PROFIBUS-DP network.
B. Dimensions
72.2 [2.84]
]
]
5
4
ADDH ADDL
3
.
1
.
2
[
0
[
7
.
6
.
9
3
5
CME-PB01
]
SPNET
6
2
.
2
[
3
.
7
5
3.5 [0.14]34.8 [1.37]
CME-PD01 has two rotary s select the PROFIBUS address.
The set value via 2 address switches, ADDH and ADDL, is
in HEX format. ADDH sets the upper 4 bits, and ADDL sets
the lower 4 bits of the PROFIBUS address.
Address Meaning
1..0x7D Valid PROFIBUS address
0 or 0x7E..0xFE Invalid PROFIBUS address
NOTE
Please download the GSD file and user manual at
http://www.delta.com.tw/industrialautomation/
Profibus 通訊模組(CME-PD01)說明書
Profibus 為 Profibus international 註冊商標。
請詳細閱讀下列說明後才使用本產品,以確保使用安全。
由於產品精益求精,當內容規格有所修正時,請洽詢代理商或至台達網站
(http://www.delta.com.tw/ch/product/em/em_main.asp)下載最新版本。
A. 面板外觀
NET LEDAddress Switches
SP LED
C. VFD-E 通訊參數的設定
ADDL
ADDH
Profibus-DP
Interface (DB9)
SPNET
CME-PD01
RS-485 (RJ45)
1: Reser ved
2: EV
3: GND
4: SG-
5: SG+
6: Reser ved
7: Reser ved
8: Reser ved
1. SP LED:變頻器與 CME-PD01 連接狀態指示
2. NET LED:CME-PD01 與 PROFIBUS-DP 連接狀態
指示
3. 位址設定鈕:設定 CME-PD01 在 PROFIBUS-DP
網路上的通信位址
4. RS-485 通訊口 (RJ-45):與 VFD-E 系列變頻器連
接並經由此 port 提供電源給 CME-PD01
5. PROFIBUS-DP 介面 (DB9):用於連接
PROFIBUS-DP 網路
6. 並連插座:使用 4-PIN socket 連接 PROFIBUS-DP
網路
VFD-E
Baud Rate 9600 Pr.09.01=1
RTU 8, N, 2 Pr.09.04=3
Freq. Source Pr.02.00=3
Command Source Pr.02.01=3
D. 電源供應
CME-PD01 電源由所連接之變頻器所供給,使用標準通訊傳
輸線(附於包裝盒內,連接 RJ-45,8pins) 連接變頻器和
CME-PD01,當變頻器上電後,電源即可輸入 CME-PD01。
E. 位址設定鈕
CME-PD01 提供兩個可旋轉之位址設定鈕來設定,其在
PROFIBUS-DP 網路上的通信位址。兩個旋鈕包括:ADDH
與 ADDL,ADDH 用來設定高 4 位元的通信位址,ADDL 用
來設定低 4 位元的通信位址,並採用 16 進制。
通信位址 說明
1..0x7D
0 或 0x7E..0xFE 無效的 PROFIBUS 位址
有效的 PROFIBUS 位址
B. 外觀尺寸
ADDH AD DL
3.6 [0.14]
59.7 [2.35]
72.2 [2.84]
CME-PB01
NOTE
請至台達網站下載 GSD 檔案及其使用手冊
http://www.delta.com.tw/ch/product/em/em_main.asp
SPNET
57.3 [2.26]
34.8 [1.37]
UNIT: mm(inch)