2.2 Control of the thermostat input of the boiler
or heat pump (HP) no-reversible 5
3/ Mounting 7
4/ Installation 9
5/ Wireless association 10
6/ Conguration 13
7/ Troubleshooting 15
7.1 Signals and possible faults on the wireless
room thermostat TYBOX 5000 15
7.2 Signals and possible faults on the TYDOM 1.0 16
EN
8/ Technical characteristics 18
3
Page 4
1/ LOCATION
Since the temperature measurement sensor is inside the box, you must install the
thermostat ush-mounting box:
- on an accessible wall at a height of 1.50 m
- away from heat sources (replaces, sunlight) and draughts (windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact with the outdoors
or with an unheated room (e.g. garage, etc.) The sleeve output in the ush-
mounting box must be blanked off (with mastic) in order to avoid unwanted air
movements that could bias the sensor reading.
4
Page 5
2/ CONNECTION
2A max. / 230V~
2A max. / 230V~
2A max. / 230V~
The diagrams provided are simplied for greater clarity. Protections and other
accessories required by standards are not illustrated. - Standard NF C15-100
and good practice must be complied with. Connected or nearby units must not
generate excessive interference (directive 89/336/EEC).
2.1 Circulator control
EN
NL
2A max. / 230V~
TYBOX 5000
Circulator
2.2 Control of the thermostat input of the boiler or heat pump (HP) no-reversible
Boiler
Thermostat
input
Thermostat
input
HP
2A max. / 230V~
2A max. / 230V~
5
Page 6
2/ CONNECTION
❶ Remove the terminal, on the back of the device, using a screwdriver.
❷ Connect the terminal to the control wire (circulator, boiler or heat pump
thermostat input).
❸ Fit the terminal back into its position.
12
3
6
Page 7
3/ MOUNTING
2 x 1,5V - AAA LR03
❶ Remove the thermostat cover by pushing the pin using a screwdriver.
❷ Attach the base by using suitable xings for mounting. Fit the cover back onto
the thermostat.
❸ Insert the batteries, with the right polarity
2
EN
1
3
Click
4
Click
7
Page 8
4/ INSTALLATION
A. Home automation gateway
for the smartphone and tablet
TYDOM application
B. System status view LED
C. Mains power supply
D. Ethernet cable
E. Ethernet port
F. Not used
G. Mains adaptor socket
H. Conguration/Information button
I. Connected TYBOX 5000
Connect your TYDOM 1.0 depending on your installation.
TYDOM 1.0 must be installed near your ADSL box line.
❶ Connect TYDOM 1.0 to the box with the Ethernet cable.
❷ Connect TYDOM 1.0 to the mains power supply.
A
B
C
D
EFGH
I
❸ Download the TYDOM application
- Depending on your unit: Login to Google play or App Store
- Search for and download the free 'TYDOM' application
❹ Congure the TYDOM application
- Note down the last 6 characters of the MAC address of your TYDOM 1.0.
- Open the TYDOM application ensuring you are connected to the local network
via WIFI, then follow the on-screen instructions.
You are now connected.
8
Page 9
❸
EN
2
1
1
❹
Tydom
MAC : 001A25 xxxxxx
9
Page 10
5/ WIRELESS ASSOCIATION
Heating
Lighting
Garage
Electric
Hydraulic
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
Add
100%9:41 AMCarrier
ON
Chauffage
Éclairage
Garage
Portail
Alarme
Consommation
Caméra
Autres
Volets
SÉLECTIONNEZ UN ÉQUIPEMENT
Ajouter
100%9:41 AMCarrier
ON
Mode expert
Chauffage
Éclairage
Garage
Électrique
Hydraulique
Portail
Alarme
Consommation
Caméra
Autres
Volets
SÉLECTIONNEZ UN ÉQUIPEMENT
Ajouter
ON
Volet cuisine
Volet chambre
Volet salon
Ajouter un équipement
VOLETS
Lumière cuisine
Lumière chambre
Lumière salon
ÉCLAIRAGES
Mes équipements
100%9:41 AMCarrier
Heating
Lighting
Garage
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
Add
100%9:41 AMCarrier
ON
Expert mode
Heating
Lighting
Garage
Electric
Hydraulic
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
ON
Shutters kitchen
Shutters bedroom
Shutters living room
Add a device
SHUTTERS
Lighting kitchen
Lighting bedroom
Lighting living room
LIGHTING
My devices
100%9:41 AMCarrier
Mes domiciles
Mes équipements
INSTALLATION
Photos
Scénarios
PERSONNALISATION
GÉNÉRAL
RÉGLAGES
Alerte
À propos
Aide
Site Internet
SUPPORT
Groupes
100%19:41
Chauffage
Éclairage
Garage
Portail
Alarme
Consommation
Caméra
Autres
Volets
SÉLECTIONNEZ UN ÉQUIPEMENT
Ajouter
ON
Mode expert
Volet cuisine
Volet chambre
Volet salon
Ajouter un équipement
VOLETS
Lumière cuisine
Lumière chambre
Lumière salon
ÉCLAIRAGES
Mes équipements
100%9:41 AMCarrier
My homes
My devices
INSTALLATION
Photos
Scenarios
PERSONALISATION
GENERAL
SETTINGS
Alerts
About
Help
Website
SUPPORT
Groups
100%19:41
Heating
Lighting
Garage
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
Add
ON
Expert mode
Shutters kitchen
Shutters bedroom
Shutters living room
Add a device
SHUTTERS
Lighting kitchen
Lighting bedroom
Lighting living room
LIGHTING
My devices
100%9:41 AMCarrier
Chauffage
Éclairage
Garage
Portail
Alarme
Consommation
Caméra
Autres
Volets
SÉLECTIONNEZ UN ÉQUIPEMENT
Ajouter
100%9:41 AMCarrier
ON
Mode expert
Chauffage
Éclairage
Garage
Électrique
Hydraulique
Portail
Alarme
Consommation
Caméra
Autres
Volets
SÉLECTIONNEZ UN ÉQUIPEMENT
Ajouter
100%9:41 AMCarrier
ON
Heating
Lighting
Garage
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
Add
100%9:41 AMCarrier
ON
Expert mode
Heating
Lighting
Garage
Electric
Hydraulic
Gate
Alarm
Consommation
Cameras
Others
Shutters
SELECT A DEVICE
Add
100%9:41 AMCarrier
ON
Associate the TYDOM application with the connected TYBOX 5000
100%9:41 AMCarrier
100%9:41 AMCarrier
RÉGLAGES
TYDOM
TYDOM
VOLETS
SHUTTERS
ouverts
open
6
6
CHAUFFAGE
HEATING
.5 °Couvert
.5 °Copen
19
19
ALARME
ALARM
ON
ON
en surveillanceactive
Photos
Accueil
Reception
Photos
ÉCLAIRAGES
LIGHTING
allumés
on
4
4
PORTAIL
GATE
CAMÉRA
CAMERAS
activated
Prog.Scénario
Prog.Scenario
INSTALLATION
INSTALLATION
PERSONNALISATION
PERSONALISATION
GÉNÉRAL
GENERAL
Alerte
Alerts
À propos
About
SUPPORT
SUPPORT
Help
Aide
Website
Site Internet
SETTINGS
Mes équipements
My devices
Mes domiciles
My homes
Scénarios
Scenarios
Photos
Photos
Groupes
Groups
100%19:41
100%19:41
❶ Select the 'SETTINGS' icon on the
❷ Select 'My devices'
home screen.
100%9:41 AMCarrier
100%9:41 AMCarrier
Mes équipements
My devices
SELECT A DE VICE
Ajouter un équipement
Add a device
VOLETS
SHUTTERS
Volet salon
Shutter s living room
Volet chambre
Shutters bedroom
Volet cuisine
Shutters kitch en
ÉCLAIRAGES
LIGHTING
Lumière salon
Lighting living room
Lumière chambre
Lighting bedroom
Lumière cuisine
Lighting kitchen
❸ Select 'Add a device'❹ Select 'Heating'
10
Shutters
Lighting
Heating
Garage
Gate
Alarm
ON
Consommation
Cameras
Others
Expert mode
Add
100%9:41 AMCarrier
Page 11
4
on
ON
6
open
HEATING
19
.5 °Copen
GATE
ALARM
activated
CAMERAS
Reception
Photos
Prog.Scenario
My homes
Photos
Scenarios
PERSONALISATION
GENERAL
Alerts
About
Help
Website
SUPPORT
Groups
Heating
Lighting
Garage
Gate
Alarm
Consommation
Cameras
Others
ON
Expert mode
Shutters kitchen
Shutters bedroom
Shutters living room
SHUTTERS
Lighting kitchen
Lighting bedroom
Lighting living room
LIGHTING
DELTA 8000
Add
100%9:41 AMCarrier
Step 1
on 2
Press the RH button on the receiver
for 3 seconds until LED 2 flashes,
then release.
TO ASSOCIATE
Add
100%9:41 AMCarrier
TO ASSOCIATE
Add
100%9:41 AMCarrier
Step 2
on 2
Press the left button briefly twice,
LED 2 should flash 3 times.
Now press "Associate".
Shutters kitchen
Shutters bedroom
Shutters living room
Add a device
SHUTTERS
Lighting kitchen
Lighting bedroom
Lighting living room
LIGHTING
My devices
OK
3 products found.
Finish
TO ASSOCIATE
Add
100%9:41 AMCarrier
Step 1
on 3
Press 3 seconds simultaneously
On the "mode" and "+" keys.
TO ASSOCIATE
Add
100%9:41 AMCarrier
Step 2
on 3
Now press on " TO ASSOCIATE".
TO ASSOCIATE
Add
Step 3
on 3
The equipement is associate.
Briefly press the MODE button
and “+” to exit.
SELECT A DE VICE
ON
❺ Select 'Hydraulic'❻ Swipe your nger over the screen to
Shutters
Lighting
Heating
Electric
Hydraulic
Garage
Gate
Alarm
Consommation
Cameras
Others
100%9:41 AMCarrier
Add
TYBOX 5000
select 'TYBOX 5000'
Add
100%9:41 AMCarrier
EN
Terminé
mode
TO ASSOCIATE
1 équipement trouvé.
OK
> 3s
❼ Next, follow the instructions displayed on the screen.
mode
mode
mode / +mode / +
11
Page 12
6/ CONFIGURATION
This menu is used to determine all the settings adapted to your installation.
❶To enter conguration mode, press the MODE button for 10 seconds until the
screen displays CF01.
❷Press + or - to set.
❸Briey press MODE to go to the next menu.
Press MODE or wait 5 seconds to exit.
CF01 - Correcting the temperature measured
Setting from -5°C to +5°C
Example: If the temperature displayed by the unit is 15°C and the actual
temperature (thermometer) is 16°C, set +1°C.
CF02 - Settings lock
0No locking (default setting)
1Total locking
2Partial locking. Modication of the temperature setting at +/-2°C
The screen will display ‘____’ if it is locked
To unlock (selection 1 and 2), simultaneously press + or - the buttons for 10
seconds.
CF04 - Frost protection mode temperature setting
Setting of 5°C to 15°C. Default value: 10°C.
12
Page 13
CF05 - Type of temperature displayed in AUTO mode
0Temperature setting display (default selection)
1Display of the measured room temperature.
1: Pressing the + or - button once displays and sets the temperature setting (in ON
mode).
The relay contact is normally open. It closes during a heating request. You can
reverse the direction of operation.
0Normally open (default selection)
1Normally closed
CF10 - Return to initial settings
This menu resets all the CF01 to CF09 settings to their default value.
By default CF10 = 0.
To reset, press + to display 1 and conrm by pressing MODE.
Association with a door/window magnetic contact (DO / MDO / DOI TYXAL+)
If a door/window magnetic contact (e.g. window) is associated with the TYBOX
5000, the heating switches to Frost Protection mode when an open window is
detected.
❶ Press the + and MODE buttons simultaneously until the screen shows
for example rF00.
❷ On the door/window magnetic contact, press the button.
❸ Check that the screen evolved and shows rF01 on TYBOX 5000.
123
mode
mode
mode / +mode / +
> 3s
14
Page 15
7/ TROUBLESHOOTING
7.1 Signals and possible faults on the wireless room thermostat TYBOX 5000
• When you press a button, the screen displays: ____
Access to the settings is locked.
To unlock, press and hold the + and - buttons for 10 seconds.
IMPORTANT:
if you want to lock the device again, refer to the conguration menu (CF02).
>10s
mode
EN
• The screen displays the low battery symbol
The batteries are spent.
. Replace the batteries.
2 x 1,5V - AAA LR03
15
Page 16
7/ TROUBLESHOOTING
7.2 Signals and possible faults on the TYDOM 1.0
LEDSystem status
Green and
ashing
Green on and
steady
Orange and
ashing
Orange and
steady
Red and steadyNo allocated IP address
Diagnostic function
Briey press the button (viewing the LED for 10 seconds)
System accessible locally and remotely, user logged in
System accessible locally and remotely
System accessible locally, user logged in
System accessible locally
Yellow and ashingFixed IP OK
Blue and ashingDHCP OK / Upnp OK
Blue and ashing (2x)
Blue and ashing (3x)
Flashing red
16
DHCP OK / Upnp Error
Check that the Upnp is activated on the BOX
DHCP in progress
Check that the DHCP is activated on the BOX
No network connection
Check the Ethernet connection
Page 17
Advanced functions
Fixed DHCP/IP
Press the button for at least 3 seconds
LEDAction
Magenta and ashing
(slowly)
Release the button (within 15 seconds)
It is advised to use the TYDOM application to access this function.
Delete password
Press the button for at least 15 seconds
LEDAction
Magenta and ashing
(rapidly)
Release the button (within 30 seconds)
RESET
Press the button for at least 30 seconds
LEDAction
Release the button
System status
Use of DHCP
Delete password
Clear associations
EN
17
Page 18
8/ TECHNICAL CHARACTERISTICS
Wireless room thermostat TYBOX 5000
• Contact output 2A (230V)
• Ball test: 125 ° C
• Rated surge voltage: 4000V
• Powered by 2 lithium batteries 1.5V, LR03/AAA (supplied)
• Class III insulation
• Radio frequency 868.7 MHz to 869.2 MHz
• Maximum wireless power: <10 mW
• Wireless remote control device
• Wireless range: 100 to 300 metres outside, variable depending on the associated
equipment (the range can vary depending on the installation conditions and the
electromagnetic environment)
• Dimensions: 80 x 84 x 21 mm
• Degree of protection: IP 20
• Wall mounting
• Installation in an environment with normal pollution levels
• Storage temperature: -10 to +70°C
• Operating temperature: 0 to +55°C
18
Page 19
TYDOM 1.0 home automation box
• Main power supply 100V~/240V~, +/-10%, 50/60 Hz 0,3A,
OUTPUT : 5V
1,0 A
• Radio frequency 868.7 MHz to 869.2 MHz
• Maximum wireless power: <10 mW
• Wireless range: 100 to 300 metres outside, variable depending on the associated
equipment (the range can vary depending on the installation conditions and the
electromagnetic environment)
• Class III insulation
• Dimensions: 100 x 100 x 30 mm
• Degree of protection: IP 30
• Operating temperature: -10 to +40°C
• Storage temperature: -20 to +70°C
• Installation in an environment with normal pollution levels
EN
The connection quality of your product may be affected due to changes on the
IP architecture on which it operates. These changes may involve (the list is not
exhaustive) a change in hardware, software update or conguration operations,
work on your operator's equipment or any other multimedia devices such as tablets,
smartphones, etc.' Android™ and Google play are Google Inc trademarks. IOS™ is
a Cisco Systems Inc trademark. WiFi is a Wireless Ethernet Compatibility Alliance
trademark. Because of changes in standards and equipment, the characteristics
given in the text and the illustrations in this document are not binding unless
conrmed.
19
Page 20
www.deltadore.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.