DELTA DORE Tybox 137 User Manual

Page 1
~1,50 m
Mini 20 cm
A
B
2
2
3
4
5
B
1
A
1
4
5
TYBOX 1x7
PROG
PROG
PROG
5 + 2
TYBOX 2x7
A
B
A B
TYBOX 137 - 237 - 337
TYBOX 337
2 x 1,5V LR03 - AAA Alkaline
230V~, 50 Hz +/- 10%
0,5 VA
Lithium 3,6 V - 2,6Ah
(10 years autonomy)
R6 / AA
868 MHz (EN 300 220)
100 m
8 max.
/ 5 A max., 230V~ (Type 1.C) /
°C -5°C / +40°C -10°C / +70°C
80 x 103 x 25 mm 54 x 102 x 20 mm 78 x 92 x 42 mm
IP 30 IP 45
R&TTE 1999/5/CE
www.deltadore.com
Important product information (➋➍)
ON
12
ON
12
ON
1
2
3
N
S
W
E
Install the outdoor sensor (TYBOX 337 only)
Press t ime
Association
Slow flashing
LED off
Room temperature
Set-point temperature
Daily programming
2 daily programs (week + week-end
Weekly programming
PROG
x1
PROG
x7
PROG
5+2
> 5s
... ... ...
OFF
- it must be installed vertically as shown on the diagram opposite.
- The recommended position is on a wall facing north
or north-west, so that it is not directly exposed to adverse weather conditions, and away from heat sources such as chimneys,
air vents and thermal bridges.
Getting started
• Unscrew the 3 screws on the front of the sensor, then lift the cover.
• Set the 2 switches to ON to activate the sensor
The outdoor sensor must be attached using screws and plugs (not provided) suitable for the surface you are attaching it to:
Operate the switch to select
the type of programming
Page 2
or
>10s
... ... ...
NO
NC
Thermostat input
Blue
Brown
Black
Gray
Installing the receiver
Replacing the batteries
1
3
4
2
1
31
1
12
0
23
0
59
2012 ...
EXIT
1
2
3
4
5
8
9
10
11
12
6
7
Time setting
1,5V - LR03/AAA
(Alkaline)
NO : Normally Open
NC : Normally Closed
Circulator control for the
boiler
Input control for boiler
thermostat
Mounting with screws
Attach to the wall using the screws and plugs provided.
Mounting using double-sided adhesive
Before affixing the adhesive, make sure the surface you are affixing it to is clean
The receiver must be positioned near the heating control (burner or thermostat input of the boiler). So as not to disturb the radio transmission, the antenna must be positioned away from all metallic parts.
You can change the direction of operation of the relay
When there is an "on" command, the relay closes. When there is an "off" command, the relay opens. You can change the direction of operation of the relay by pressing the corresponding button on the receiver for 10 seconds.
Turn the selector dial to .
The days flash.
Press + or - to select the day, then press OK to confirm and move on to the next setting.
Repeat the process to set the hours and minutes.
To exit the "time setting" mode, turn the selector dial.
You have approximately 30 seconds to change the batteries before the time setting is reset (if this happens, reprogramme the date and time).
When the batteries symbol appears. you have approximately 1 month to change the batteries (2 1.5 V LR03 or AAA alkaline batteries).
Page 3
>5s
0
2
0
1
0
1
EXIT
1
2
3
4
5
6
7
8
9
10
MENU 1
Length of a programme stage
Prog
60', 30', 15'
Tybox
137
Tybox
237
Tybox
337
X
60 min.
30 min.
15 min.
Tybox
137
Tybox
237
Tybox
337
X
Comfort regulated by TYBOX
Comfort temperature set on each radiator or convector
Tybox
137
Tybox
237
Tybox
337
X X X
Anti-seizing off
Anti-seizing on (circulator pump ON: 1 minute / 24h)
Press button 1.
To change the different settings, press the + or - buttons, then press the OK button to confirm and move on to the next setting.
Turn the selector dial to , then press the i button for 5 seconds
For electrical or hot-water heating systems with thermostatic valves, the thermostat for each radiator or convector may be adjusted to give a comfortable temperature. In this case, the TYBOX only regulates the Economy and Frost-Protection temperatures.
To exit the mode, turn the selector dial to another mode.
Page 4
: 5°C --> 30°C
19°C
: 5°C --> 30°C
16°C
>5s
1
0
EXIT
1
2
3
1
0
MENU 2
0,2°C < < 2°C
Hysteresis
0,4°C
Temperature displayed in AUTO mode
0 : Continuous display of the temperature setting. In this case, press the i button to display the room temperature
1 : Continuous display of the room temperature. In this case, press the i button to display the temperature setting.
Tybox
137
Tybox
237
Tybox
337
X
Control time base
If you choose an "on/off" type setting, you can adjust the hysteresis (or differential) via menu 2-11
Tybox
137
Tybox
237
Tybox
337
X X X
Minutes
Minutes
Minutes
Minutes
On/Off
Time display mode 12h-24h
Tybox
137
Tybox
237
Tybox
337
X X X
24h
12h
Measured temperature correction (-5°C à +5°C par pas de 0,1°C).
Example: If the temperature displayed on the device is 19°C and the observed temperature is 20°C, adjust the temperature by +1°C, then confirm by pressing OK.
Tybox
137
Tybox
237
Tybox
237
X X X
- 5°C < < +5°C
Before changing this setting,
the device must have been in
operation for at least 2 hours.
Presence of transmitter
Tybox
137
Tybox
237
Tybox
337
X X
No
Ye s
Temperature settings controlled by the transmitter
Permission to change
Programme and settings
0 : Modifications permitted to programme and settings
1 : Modifications to programme not permitted and adjustment of settings limited. Tybox 137: Comfort setting limited between 16 and 22°C. Tybox 237-337: +/- 3°C either side of the last setting.
Tybox 137
Tybox
237
Tybox
337
X X X
: 5°C < < 30°C
: 5°C < < 16°C
16°C < < 22°C
13°C < < 19°C
5°C < < 11°C
+/- 3°C
PROG
To change the different settings, press
the + or - buttons, then press the OK button
to confirm and move on to the next setting.
Turn the selector dial to , then press the i button for 5 seconds
To exit the mode, turn the selector dial to another mode.
Press button 2.
Page 5
Automatic time change (summer/winter time)
Tybox
137
Tybox
237
Tybox
337
X X X
Time before boiler maintenance (0 to 365 days)
Reprogramme after each maintenance operation
Tybox
137
Tybox
237
Tybox
337
X
X
X
--- (0) to 365 days
Optimisation
Tybox
137
Tybox
237
Tybox
337
X
No
OPTIM.
OPTIM +
OPTIM.
Anticipation to reach the desired temperature at the programmed time (according to the outside temperature).
OPTIM +
Anticipation to reach the desired temperature at the programmed time (according to the outside temperature) + Automatic correction based on history from previous days (auto-adapt). The history from previous days can be deleted via menu 2-16.
Start Prog
Prog
Resetting the history in OPTIM +
Tybox
137
Tybox
237
Tybox
337
X
No
Ye s
Resetting the boiler operating time meter
Tybox
137
Tybox
237
Tybox
337
X X X
No
Ye s
Page 6
>5s >5s
EXIT
OR
OR
OR
OR
1
2
3
4
4
4
3
3
Init
Menu 1
Init
Menu 2
Init RF
Restoring factory settings
OK
2
1
5
4
3
6
8
9
8
... ... ...
OFF
> 3s
>5s
ON
12
ON
12
TYBOX 337
TYBOX 137-237
EXIT
EXIT
OR
1
0
7
No
Ye s
The products are associated when delivered.
To associate a new product or re-associate the products (after a reset) follow the instructions below :
The factory settings may be restored for each of the menus.
Turn the selector dial to , then press the i button for 5 seconds.
Press the button for 5 seconds on the menu you wish to reset.
Press OK to confirm the reset.
To exit the mode, turn the selector dial
Do you have one or more home automation radio products in your system? (e.g. Opening detector)
On the receiver, press the button for 3 seconds until the LED flashes. Release.
On the transmitter,
turn the selector dial to , then press the
i button
for 5 seconds.
Press the R button, then fill in menu R-01 (see below) and/or move on to the next menu by pressing OK
Rad menu
Press the i button If "1" is displayed, the product has been associated.
To exit the mode, turn the selector dial.
To exit the mode, turn the selector dial.
The receiver LED is no longer flashing. The receiver is associated with the transmitter
To associate a sensor,
press the button.
Loading...