DELTA DORE TYBOX 1010 WT User Manual

Page 1
TYBOX 1010 WT
www.deltadore.com
User guide
Page 2
Contents
1- AUTO mode
1- AUTO mode ................................................................................ 3
2- Technical unit indicator lights ......................................................3
3- Home automation functions ........................................................ 4
4- Date and time settings ................................................................ 4
5- Setting the temperature settings ................................................5
6- Consumption data display .......................................................... 7
7- Programming .............................................................................. 8
8- ‘i’ information button ................................................................ 10
9- Days home ............................................................................... 11
10- Absence .................................................................................11
11- Heating override ..................................................................... 12
12- DHW override ......................................................................... 12
13- AUTO mode ............................................................................ 13
14- Help ........................................................................................ 14
- 2 - - 3 -
TYBOX controls the heating depending on the active programme (P1 to P6) and required temperature (settings).
Control output start
Information button
Override
/ )
(
Day of the week
Time
Temperature measured
Profile of active programme
Consumption data display
Hot water tank override
• Heating and DHW (Domestic Hot Water) overrides possible,
• Access to consumption data (
),
- Access to the system status ('i' button) and to any faults,
• Changeover to standby after a 30 seconds time-out period
2- Technical unit indicator lights
Bus indicator light
Blinks in sync with the data Steady blinking = Bus fault Off = Power supply failure
Electronic meter indicator light
On = Normal operation Blinking = remote-info fault
DHW load control indicator light
On = Load control in progress
DHW (Domestic Hot Water) indicator light
On = ON Off = OFF
"Control output" indicator light
On = ON Off = OFF
TYBOX
Ref. : 4100795
4VA
230V~50Hz
246810
1
3 5 7 9
BUS A
C
Ti1 Ti2 Ti3
BUS
N
L
11
12
3A - 230V
16 17 19 2018
T C
~
Page 3
3- Home automation functions
5- Setting the temperature settings
The home automation functions control the following functions either locally or remotely via a tablet or a smartphone:
- heating control (heat/cool mode, Auto/Off/Absence/override mode),
- display of the consumption data over the current month and the history of previous months (electricity, gas, etc.). To get this service, you have to associate the room unit with the TYDOM home automation gateway.
Example with the TYDOM 2000 home automation gateway
Smartphone
TYDOM 1000
Volets
Eclairages
Chauffage
1
Alarme
Garage
Portail
Autres
Scénarios
Pièces
ADSL BOX
TYDOM 2000
Wireless
OR
Tablet
TYDOM 2000
Volets
Scénarios
1
Eclairages
Chauffage
Alarme
Garage
Portail
Autres
Pièces
Wi (local)
or
Internet (remote)
Ethernet cable
4- Date and time settings
These settings are only available if the control output is used and declared (configuration menu 2-08 > 0, installation instructions). The Heat/Cool option will only be available if the presence of a cooling system has been declared (installer menu, 0-06). Press '+' or '-'. Confirm with OK.
2
3
5 30°C
1
4
6
5
5 16°C
7
EXIT5 30°C
Turn the selector knob to exit the mode
2 4 5
3
JJ/MM/AA HH/MM
1
Enter the date, then the time. Confirm with OK.
Return to the previous setting
EXIT
Turn the selector knob to exit the mode
- 4 - - 5 -
Page 4
6- Consumption data display
From the AUTO,
Press .
or modes.
Gas
Elec.
Cooling
Heating
DHW
Others
Plugs
: Total gas consumption
: Total electric consumption
: Cooling consumption
: Heater consumption
: Domestic Hot Water consumption (DHW)
: Consumption of devices connected to the mains
- To change over to a different consumption, turn the selector knob.
- Depending on the system's configuration, some symbols will not be avail­able.
- To exit the "Consumption data display" mode, press .
• If you own a "hybrid" boiler, the heating and DHW consumption data will be displayed for each type of energy used (gas and electricity).
• The consumption indices and the history can be reset (menu 2-24, installation instructions).
Example: To view the total electric consumption of your system turn the selector knob to select the
History: Press '+' to display the overall consump­tion history from the beginning of the current year, then for the previous year
Displays the con­sumption for the current month
History: Press '-' to display the consumption history for the 12 previous months
symbol.
- 6 - - 7 -
Page 5
7- Programming
This menu enables the following functions:
- assigning a daily programme P1 to P6 for each day of the week, and appli­cable in AUTO mode,
- modifications to programme P6 (P1 to P5 are not editable),
- modifications to programme P0 (Days home) applicable in
• Programme P6 can be viewed. Press >> to scroll the programme steps. Modifications to programme P6 are applied to all the days when the programme is assigned.
2
1
+
OU
OK
2
mode.
Non editable P1 to P5
Editable P0
6h 24h0h 21h
6h
P1
P2
6h 8h
6h 8h
13h11h 23h17h
P3
P4
P5
You have to set the start (Start) and (Stop) time for the Comfort period (e.g. 6am to 9pm).
24h0h 23h
24h0h
23h17h
24h0h
24h0h
24h0h
Day 1
Day 2
3
OK
Select the programme to be applied on day 1.
Select with '+' and '-'. Confirm with OK.
Editable P6
OK OK OK
7h 9h 0h0h 23h18h
Example: Comfort mode from 7 to 9am and 6
EXIT
to 11pm
4
OK
5
OK
6
+ +
Select the programme to be applied on day 2.
+ +
OK
Press the following buttons as many times as necessary:
-
to create the economy periods
to create the comfort periods.
-
OK
Repeat the procedure for the other zone, where necessary.
- 8 - - 9 -
Page 6
8- 'i' information button
4
9- Days home
From the AUTO, or modes, you can view the system status ('i' button) and any faults (refer to the "Help" section).
Operating hours meter (boiler).
h (ON)
023
Temperature setting
Time to boiler maintenance
• The operating hours meter is only active if the menu 2-08 (refer to instal­lation instructions) is not 0 or PROG.
• The operating hours meter can be reset (menu 2-17).
• The period before maintenance must be initialised after each mainte­nance operation (menu 2-20).
10- Absence
6h 24h0h 21h
This menu monitors programme P0 (refer to the "Programming" section).
• Heating and DHW overrides possible.
• Access to consumptions
• Switch to stand-by after a 30 seconds time-out period
Example: You are away from Friday 10/02 to Saturday 18/02. The heating is on 'Frost Protection' mode over this period. The DHW system is off (modifiable, installer menu 1-05).
JJ/MM/AA
Set the Frost Protection temperature (except for Cool mode).
Turn the selector knob to then enter the date of return with '+' and '-'. Confirm with OK.
18/02 00:00
Automatic return to AUTO mode on Saturday 18/02 at 00:00h.
- 10 - - 11 -
Page 7
11- Heating override
4
6h 8h
From the AUTO mode.
17h15h30 23h
When you apply a 'Stop' or 'Frost Protection' override from a tablet or smartphone, the and symbols are not displayed on the room unit.
E.g. it is 3.30pm and you want to run the
0h0h
Comfort mode before the set time (5pm) on zone 1.
At 5pm, the programme will resume its normal cycle.
13- Stop mode
In this mode:
- the heating is off.
- the DHW override is possible
- the consumption data is displayed (button
- the system status ('i' button) and any faults (refer to the "Help" section) are displayed.
).
Boiler operating hours meter
hON
023
12- DHW override
From the AUTO, or modes.
Press .
Press the 'i' button several times, to view the system's status
The
symbol blinks. The DHW is restarted for 6 hours.
Restart may be suspended when changing to Off-Peak times or by pressing
again.
- 12 - - 13 -
Number of days to maintenance
Page 8
14- Help
Nothing is displayed on the room unit screen.
There is no power supply.
Check the circuit breaker.
You cannot set the Frost Protection temperature in absence mode.
Cool mode is active.
The Frost Protection mode settings are not available in this mode.
The
symbol does not appear.
The DHW is not managed by the device.
Refer to menu 1-04, installation instructions.
The
Boiler maintenance is due in less than 30 days. OR A system fault has been identified.
From the AUTO, "Fault".
dEF 6:
There is a communication fault between TYBOX and the technical unit (Bus A).
Check the system.
dEF 7:
There is a communication fault with the electronic meter.
Check the connection with the meter.
symbol blinks.
or , modes press the 'i' button to display the type of
- 14 - - 15 -
Page 9
2004/108/EC - 2006/95/EC
EN