![](/html/17/173c/173c2f0290655c3d55bcff9e7ea6bb9902e43dd802e2fc79bb657853d7c45c02/bg1.png)
CHAPTER 4 DIGITAL KEYPAD (VFD-PU05) OPERATION
4.1 Description of the Digital Keypad VFD-PU05
LED Display
Display frequency, current, voltage
and error, etc.
Part Number
Status Display
Display the driver's current status
When "PU" lights, RUN/STOP is
controlled by PU05. When "PU" is
dark, RUN/STOP is set by 00-21.
When "EXT" lights, frequency
command and torque command
is set by 00-20. When "EXT" is dark,
it is controlled by PU05.
Right key
Moves the cursor right
MODE Selection key
Press this key to view different
operating values
Left key
moves cursor to the left
F
H
U
JOG
VFD-PU05
EXT PU
PU
VFD-V Series
4
FWD/REV Direction key
RUN
RUN key
4.2 Explanations of Display Messages
Messages Displayed Descriptions
Master frequency of the drive
ctual operation frequency output to the motor from
the drive
User-selected content (the side DC-BUS voltage)
STOP
RESET
STOP/RESET
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-1
![](/html/17/173c/173c2f0290655c3d55bcff9e7ea6bb9902e43dd802e2fc79bb657853d7c45c02/bg2.png)
VFD-V Series
Messages Displayed Descriptions
Output current
Parameter duplication function: press
PROG/DATA and hold still for about 2~3 seconds,
it will start blinking and will duplicate the parameter
to PU-05.
Press the “Up” or “Down” key to switch to the
“SAVE” function
Parameter duplication function: press
PROG/DATA and hold still for about 2~3 seconds,
it will start blinking and will write the parameter into
the drive.
Press the “Up” or “Down” key to switch to the
“READ” function
The specified parameter item
Value of the parameter content
If the “End” message is displayed (as shown in the
figure), for about 1 second, it is an indication that
the data has been accepted and saved to the
internal memory automatically.
Displayed when the preset data is not accepted or
that the value goes over the limit
4-2