VFD-L Series User Manual
115V 200W-400W 230V 200W-2HP Simple General Purpose AC Drive
SIA ELTA ELECTRONICS, INC.
AOYUAN Plant/
1-1, SHIEN P AN ROAD,
UEI SAN INDUSTRIAL ZONE
AOYUAN 333, TAIWAN, R.O.C
EL: 886-3-362-6301 AX: 886-3-362-7267 ttp://www.deltaww.com/acdrive
ORTH/SOUTH AMERICA ELTA PRODUCTS ORPORATION ales Office/
.O. BOX 12173 101 DAVIS DRIVE
TP, NC 27709 U. S. A.
EL: 1-919-767-3813 AX: 1-919-767-3969 ttp://www.deltaww.com/acdrive
UROPE ELTRONICS (Netherlands) .V. ales Office/
ndustriegebied Venlo Nr. 9031
olumbusweg 20
L-5928 LC Venlo he Netherlands EL: 31-77-342-1930
AX: 31-77-342-1931
1
Preface
Thank you for choosing D ELTA’s VFD - L seri es AC Dr ive. The VFD-L series is manufact ur ed using high-quality compon en ts, m ater ial and incorporating the latest microprocessor technol og y available.
This manual will help in the installation, parameter setti ng, troublesho oting, and daily maint enance o f the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drive. Keep this operating manual handy and distribute to all users for reference.
Important Notes:
DANGER!
T
disconnect wires whi le power i s applied t o the ci rcuit. Only qualified t echnicians sh ould per form maintenance on the VFD-L.
CAUTION!
T
components are espec ially sensit ive to static el ectricity . To avoid damag ing these com ponents, do not touch the circuit boards with metal objects or your bare hands.
DANGER!
T
after the power has been turne d off. To avoid person al injury, d o not remov e the cover o f the AC drive until all “DISPLAY LED” lig hts on the digital key pad are off. Please note that there ar e live components exposed when the AC drive is open,. Be careful to not touch these live parts.
CAUTION!
T
comply with the laws of the country where the AC drive is to be installed.
DANGER!
T
input/output terminals. Never connect the AC drive output terminals U/T1, V/T2, W/T3 directly to the AC main circuit power supply.
AC input power must be disco nnected be fore any m aintenanc e. Do not c onnect or
There are highly sensitive MOS components on the printed circuit boards. These
A charge may still remain in the DC-link capacitor with hazardous voltages even
Ground the VFD-L using the ground terminal. The grounding method must
The AC drive may be destroyed beyond repair if power is misapplied to the
2
Chapter 1 Receiving and Inspection
MODE :VFD007L21A
INPUT :1PH/9.7A 3PH/5.1A 200-240V 50-60Hz
OU T PU T :3 P H 0-240 V 4.2A 1.6kVA 1HP
Freq. Rang e:1.0~40 0Hz
DELTA ELECTRONICS, INC. MADE IN XXX XX
007L21AT101001
AC Drive Model
Input Spec.
Output Spec.
Output Freq. Range
Bar C ode
Serial NO.
VFD 007 L 21 A
version
A standard
B including EMI
Filter
VFD-L series
Inp ut vo ltag e
002:0.2kW
004:0.4kW
007:0.75kW
015:1.5kW
A p plic a ble mo t o r c apacit y
Varia ble Frequency Drive
Production number
Production week
Production year 2003
Production factory
(T: Taoyuan, W: W ujuang)
This VFD-L AC drive has gone through rigorous quality control tests at the factory before shipment. Since many things may happen during shipping, please check for the following after receiving the AC motor drive.
è
Inspect the unit to insure it was not damaged during shipment.
è
Make sure that the part number indicated on the nameplate corresponds with the part number of
your order.
Nameplate Information: Example of 1HP230V
Model Explanation:
Series Number Explanation:
If there is any nameplate information not corresponding to your purchase order or any problem, please contact your distributor.
3
Dimension
RA
RC+10V
AVIM0M1M2M3
GND
STO P
RUN
FWD
REV
MODE
RESET
Do not connect AC power to output
WARNING
Read the user man ual before operation.
Do not inspect comp onents until LEDs
are turned off for at least 1min.
terminals (U,V,W).
MIN.
MAX.
VFD-L
RS-485
230V IPHASE
0.75KW
RUN STO P
PRO G DATA
8
+
4
Chapter 2 Wiring
RS-485
61
RARC120VAC/28VDC 3A
010VDC
VR 3K 5K
AV I
GND
+10V 10mA(MAX )
321
VR
RJ-11
1:+EV
2:GND
3:SG-
4:SG+
+18V
+18V
+18V
M0M1M2
GND
+18V
4.7K
M3
4.7K
4.7K
4.7K
Factory default settings
Forward/Stop
Reverse/Stop
Reset
Multi-step 1
Comm on Signal
P owe r sup ply for Po ten tiom e te r
Master Freq. setting
Analog voltage
Analog current
Motor
Multi-function in dication
output contacts
Factory default:
Fault Indication
Main circuit (power)
term inals
Co ntrol circ uit term inals
S h ie lde d leads
*
If the AC Drive m odel is VFD002L11A/B, VFD004L11A/B, VFD002L21B, VFD004L21B
or V FD 007 L21B , please use power terminals R/L1 and S/L2.
*If the AC Drive model is VFD00 2L21A , VFD 00 4L21A or VF D00 7L21A , 3 phase pow er
may be used on R/L1, S/ L2, T/L3.
*If the AC Drive model is VFD 015L23A , single phase pow er is not allow ed.
NO T E: Do not plug in a Mo dem or telephone line to the RS-485 com m unication port,
per m ane nt da m age m ay r esul t . Ter m i n als 1 & 2 a re t he pow er s ource f or t he
opti o na l c op y keypad and s ho uld not be used wh i l e u si ng RS -485
com m uni cati on.
Main Circuit Power
Communication
p ort
+10V
Basic Wiring Diagram
Users must connect wiri ng accordi ng to the ci rc uit diag ram show n below . Pl ease follow all National and State wiring codes, when wiring the VFD-L.

5/
5/
87
6/
7/
6/
7/
è
è
è
è
97
,0
a
:7
'
è
5
Main circuit wiring
Si ng l e phas e m odel s i nput f r om R / L1, S/L2
A C line in p u t terminals
grounding
UP/DOWN
Function
Display key
Data
Confirmation key
RUN/STOP
RS485
communication
port
Grounding
Motor connections U/T1, V/T2, W/T3
M o to r cap a city
and input power
Frequency
setting kno b
LED display
The signal selection
f or A VI t o i nput
DC0~+10V
or 4~20 m A
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3
RA
RC
+10V
AV I
M0
M1
M2
M3
GND
Relay
Wire Gauge:22-24AWG
Torque: 4Kgf-cm
Control circuit wiring
A
f
r
n
e
a
q
l
M
o
(
1
u
u
2
t
l
p
0
t
i
u
V
-
f
t
A
u
c
C
n
o
c
/
n
D
t
t
i
a
o
C
c
n
2
t
i
8
n
V
d
i
3
c
A
a
)
t
i
o
n
u
o
e
g
n c
y c
o
m m a
n
d
V o l
t
a g
e ,
c
u
r
r
e
n t
P o
w e
r f
o r
s
p
e e
d s
e t
t
i
n
g
M u
l
t
i
-
f
u n
c
t
i
o
n a
s
s
i
s
t
a
n t
t
e
r
m i
n a
l
M u
l
t
i
-
f
u
n c
t
i
o n
i
n p
u t
s
e
l
e
c
t
i
o n
1
M u
l
t
i
-
f
u
n c
t
i
o n
i
n p
u t
s
e
l
e
c
t
i
o n
2
M u
l
t
i
-
f
u
n c
t
i
o n
i
n p
u t
s
e
l
e
c
t
i
o n
3
C o
m m o
n s
i
g
n a
l
6
Wiring Notes: PLEASE READ PRIOR TO INSTALLATION.
Forward
1.
CAUTION: Do not connect the AC input to any of the U/T1, V/T2, W/T3 terminals, as it will
damage the AC drive.
2.
WARNING: Ensure all screws are tightened to the proper torque rating.
3. During installation, follow all national and local electrical, construction, and safety codes for the country the drive is to be installed in.
4. Ensure the appropriate protective devices (circuit breaker or fuses) are connected between the power supply and AC drive.
5. Make sure that the leads are con nected corre ctly and the AC driv e is properly grounded. (Gr ound resistance should not exceed 0.1Ö.)
6. Use ground leads that comply with AWG/MCM standards and keep them as short as possible.
7. Multiple VFD- L uni ts can be installed in on e location. All the units should be grounded directly to a common ground terminal. The VFD-L ground terminals may also be connected in parallel, as shown in the figure below. Ensure there are no ground loops.
When the AC dr ive outp u t t erm in a ls U/T 1 , V /T 2 , an d W /T3 ar e conn e ct ed to t he m oto r te rmin a l s
9/
running
U, V, and W, respectively, the motor will rotate counterclockwise (as viewed f rom the shaf t ends of the motor) when a forward operation command is received. To reverse the direction of motor rotation, switch over any of the two motor leads.
9. Make sure that the power is capable of supplying the correct voltage and required current to the AC drive.
10. Do not attach or remove wiring when power is applied to the AC drive.
11. Do not monitor the signals on the circuit board while the AC drive is in operation.
12. Route the power and control wires separately, or orthogonal to each other.
13. If a filter is required for reducing EMI (Electro-Magnetic Interference), install it as close as possible to AC drive. EMI can also be reduced by lowering the Carrier Frequency.
14. If the AC drive is installed in the place where a load reactor is needed, install the filter close to U/T1, V/T2, W/T3 side of AC driv e. Do not use a Capaci tor or L-C Filt er (Inductance-C apacitance) or R-C Filter (Resistance-Capacitance).
15. When using a GFCI (Ground Fault Circuit Interrupt), select current sensor with minimum current 200mA, and minimum detec ti on time 0. 1-second to avoid nuisance tripping.
7
Chapter 3 Summary of Parameters
s
y
K
s
y
Group 0: User Parameters
=
The parameter may be set during operation.
Parameter
=
=
=
Group 1: Basic Parameters
0-00
0-01
0-02 Parameter reset 10: Reset Parameters to Factory Setting 0 0-03 Start-up display of AC
0-04 User-defined Unit
0-05 User-defined coefficient 0-06 Software version Read only #.# 0-07 Password input 0 ~ 999 0 0-08 Password configuration 0 ~ 999 0
Identity code of drive (Read only)
Rated current display (Read only)
drive
Functions Settings
1: 40W 2: 100W 3: 200W 4: 400W 5: 750W 6: 1.5KW
40W: 0.4A 100W: 0.8A 200W: 1.6A 400W: 2.5A 750W: 4.2A
1.5K: 7.0A
0: F (Frequency command) 1: H (output frequency) 2: U (user-defined un it) 3: A (output current)
0: Display User-Defined Unit (u ) 1: Display Counter Value (C) 2: Display Process Operation (1=tt) 3: Display DC-BUS voltage (U) 4: Display output voltage (E)
0.1 ~ 160
Factor
Setting
0
0
1.0
Parameter
= = =
1-00 Maximum operation Freq. 50.0 ~ 400Hz 60.0 1-01 Maximum setting Freq. 10.0 ~ 400Hz 60.0
1-02 Maximum output voltage 2.0 ~ 255V 220 1-03 Mid-point freq. 1.0 ~ 400Hz 1.0 1-04 Mid-point voltage 2.0 ~ 255V 12.0 1-05 Minimum output freq. 1.0 ~ 60.0Hz 1.0 1-06 Minimum output voltage 2.0 ~ 255V 12.0 1-07 Upper bound of freq. 1 ~ 110% 100 1-08 Lower bound of freq. 0 ~ 100% 0.0 1-09 Accel time 1 (Tacc1) 0.1 ~ 600 Sec 10.0 1-10 Decel time 1 (Tdec1) 0.1 ~ 600 Sec 10.0 1-11 Accel time 2 0.1 ~ 600 Sec 10.0
Functions Settings
Factor
Setting
8
Parameter s
y
n
P
rs
y
= = = =
1-12 Decel time 2 0.1 ~ 600 Sec 10.0 1-13 JOG Accel time 0.1 ~ 600 Sec 10.0 1-14 JOG Decel time 0.0 ~ 600 Sec 10.0 1-15 JOG frequency 1.0Hz~400Hz 6.0 1-16 Auto-accel/decel
Functions Settings
0: Linear Accel/Decel
Factor
Setting
0 1: Auto accel, linear decel 2: Linear accel, auto decel, 3: Auto Accel/Decel 4: Linear accel. Auto decel, stall preventio
during deceleration
5: Auto accel. Auto decel, stall prevention
during deceleration
1-17 1-18
S-curve setting in acceleration S-curve setting in deceleration
0 ~ 7 0 0 ~ 7 0
Group 2: Operation Method Parameters
aramete
2-00 Source of frequency
command
Functions Settings
0: Digital keypad 1: 0 ~ 10V from AVI
Factor
Setting
0
2: 4 ~ 20mA from AVI 3: Controlled by V.R on drive 4: RS-485 communication interface
2-01 Source of operation
command
0: By digital keypad 1: By external terminals, keypad STOP
0
enable
2: By external terminals, keypad STOP
disable
3: By RS-485 communication interface, keypad
STOP enable
4: By RS-485 communication interface, keypad
2-02 Stop method
STOP disable
0: Ramp stop
0
1: Coast stop 2-03 Carrier freq. 2-04 Reverse operation inhibit
3 ~10K Hz
0: Enable reverse
1: Disable reverse
10
0
2: Disable forward 2-05 ACI (4 ~ 20mA)
input loss detection
2-06 Line Start Lockout
0: Decel to 0Hz
1: Stop immediately, display EF
2: Run with the last freq.
0: Enable
1: Disable
0
0
9
Group 3: Output Function Parameters
s
F
ry
g
1 T P
e
0 M o
0 1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1
y
e
n
Parameter
3-00 3-01 3-02 3-03
esired freq. attained erminal count value 0 ~ 999 0 reliminary count valu
utput)
Functions Settings
.0 ~ 400 Hz 1.0 ~ 999 0
ulti-function (relay
: not used : AC drive operational
acto
Settin
8
: Max. Output Freq. Attained : Zero Speed : Over Torque : Base-Block (B.B.) : Low Voltage Detection : AC Drive Operation Mode : Fault Indication : Desired Freq. Attained 0: PLC Program Running 1: PLC Program Step Complete 2: PLC Program Complete 3: PLC Program Operation Pause 4: Terminal Count Value Attained 5: Preliminary Count Value Attained 6: Ready State Indicator
Group 4: Input Function Parameters
Parameters Functions Settings
=
4-00
=
4-01
=
4-02 Potentiometer freq. gain 4-03 Potentiometer 0: not used
Potentiometer bias freq. Potentiometer bias
polarity
0.0
350Hz
0: positive bias 1: negative bias 0 1200&
reverse motion 1: reverse motion enable enable 2: forward motion only
4-04
4-05 4-06
Multi-function input terminal1 (M1) (d 0d 20)
Multi-function input terminal 2(M2) Multi-function input terminal 3(M3) (d 0, d 4d 20)
0: not used 1: M0: FWD/STOP, M1: REV/STOP 2: M0: RUN/STOP, M1: FWD/REV
3: M0, M1, M2: 3-wir e operation control mod 4: External fault, normally open (N.O.)
5: External fault, normally closed (N.C.) 6: RESET 7: multi-step speed command 1 8: multi-step speed command 2 9: jog operation 10: accel/decel speed inhibit 11: first or second accel/decel time selectio 12: base-block (B.B.),normally open (N.O.) 13: base-block (B.B.),normally closed (N.C)
Factor
setting
0.0
100
0
1
6 7
10
Parameters Functions Settings
y
s
F
ry
g
p
y
e
0
s
F
ry
g
d d
re
e
4-06 Multi-function input 7
terminal 3(M3)
(d 0, d 4d 20)
14: increase master freq. 15: decrease master freq. 16: run PLC program 17: pause PLC 18: counter trigger signal 19: counter reset 20: select ACI/deselect AVI
Group 5: Multi-step Speed and PLC Parameters
Factor
setting
acto
Settin
0
Parameter
5-00 1st step speed freq. 0.0 ~ 400Hz 0.0 5-01
2nd step speed freq. 0.0 ~ 400Hz 0.0 5-02 3rd step speed freq. 0.0 ~ 400Hz 0.0 5-03 PLC mode 0: Disable PLC operation
Functions Settings
1: Execute one program cycle 2: Continuously execute program cycles 3: Execute one program cycle step by ste
(separate by STOP)
4: Continuously ex ecut e o ne pr og r am cycle step b
step (separate by STOP)
5-04 PLC forward/revers
motion
5-05 Time duration step
Group 6: Protection Parameters
Parameter
6-00
5-06 Time duration step 1 0 ~ 65500 Sec 0 5-07 Time duration step 2 0 ~ 65500 Sec 0 5-08 Time duration step 3 0 ~ 65500 Sec 0
Functions Settings
Over-Voltage Prevention Level
6-01 Over-current
Prevention Level
6-02 Over-torque
detection
0 ~ 15 (0: Forward 1: Reverse) 0 0 ~ 65500 Sec 0
0:disable
350~410V
0: disable
20~200% 0:disable
1:enable during constant speed operation an
continues until the continuous limit is reached.
acto
Settin
390 170
0
2:enabled during constant speed operation an
halted after detection.
3:enabled during accel and continues befo
continuous output time limit is reached.
4:enabled during accel and halted after over-torqu
detection.
6-03
Over-torque detection level
30 ~ 200% 150
11
s
F
acto
ry
g
d
nt
P
rs
nt
s
, ,
Settin
0
0
Parameter
6-04 6-05
Over-torque detection time Electronic thermal overload relay
6-06
Electronic thermal characteristic
6-07 Present fault recor 6-08
6-09 6-10 6-11
6-12
Second most rece fault record Third most recent fault record Forth most recent fault record Fifth most recent fault record
Sixth most recent fault record
Functions Settings
0.1 ~ 10.0 Sec 0.1 0: Not used
1: Act with standard motor 2: Act with special motor
30~600 Sec 60 0: No fault occurred
1: oc (over current) 2: ov (over voltage) 3: oH (over heat) 4: oL (over load) 5: oL1 (electronic thermal) 6: EF (external fault) 7: Reserved 8: Reserved 9: ocA (current exceed during acceleration) 10: ocd (current exceed during deceleration) 11: ocn (current exceed during steady state)
Group 7: Motor Parameters
aramete
= =
= =
7-00 Motor rated current 30~120 % 85 7-01 Motor no-load curre
7-02
Torque compensation
7-03 Slip compensation 0.0 ~ 10.0 0.0
Group 8: Special Parameters
Parameter
8-00 DC braking voltage level 0 ~ 30% 0 8-01
8-02
DC braking time during start-up DC braking time during stopping
Functions Settings
0 ~ 90 % 50 0 ~ 10 1
Functions Settings
0.0 ~ 60.0 Sec 0.0
0.0 ~ 60.0 Sec 0.0
Factory
Setting
Factory
Setting
8-03 Start-point for DC braking 0.0 ~ 400.0 Sec 0.0 8-04 Momentary power loss 0: Stop operation after momentary power
loss.
0
1: Continues after momentary power loss
speed search starts with master freq.
2: Continues after momentary power loss
speed search starts with min. output freq.
12
s
s
t
s
y
II e
e
Parameter
8-05
Max. allowable power los time
Functions Settings
0.3 ~ 5.0 Sec 2.0
Factory
Setting
8-06 B.B. time for speed search 0.3~5.0 Sec 0.5 8-07
Max. speed search curren level
30~200% 150
8-08 Skip freq. 1 upper bound 0.0~400 Hz 0.0 8-09 Skip freq. 1 lower bound 0.0~400 Hz 0.0 8-10 Skip freq. 2 upper bound 0.0~400 Hz 0.0 8-11 Skip freq. 2 lower bound 0.0~400 Hz 0.0 8-12 Skip freq. 3 upper bound 0.0~400 Hz 0.0 8-13 Skip freq. 3 lower bound 0.0~400 Hz 0.0 8-14 Auto restart after fault 0~10 0 8-15 AVR function 0: AVR function enable
2
1: AVR function disable
8-16
Group 9: Communication Parameters
8-17
yn a m i c b r a k i n g vo l t a g e 350 ~ 450V 380 C braking lower bound limit 0.0 ~ 400 Hz 0.0
2: AVR function disable when decel
Parameter
= =
9-00 Communication address 1 ~ 247 1 9-01 Transmission speed 0: Baud rate 4800
Functions Settings
1: Baud rate 9600
Factor
Setting
1
2: Baud rate 19200
=
9-02 Transmission fault
treatment
0: Warn and continue running 1: Warn and ramp to stop
0
2: Warn and coasting stop 3: No warn and keep running
Modbus communication
=
9-03
=
9-04 Communication
watchdog timer
protocol
0: Disable 1~20: 1 ~ 20 Sec
0: 7,N,2
1: 7,E,1 ASC mod
2: 7,O,1
3: 8,N,2
4: 8,E,1
0
0
5: 8,O,1
6: 8,N,2
7: 8,E,1
8: 8,O,1
RTU
mod
13
t
e
1 2
.
3 4 5
s
1 2
3
.
1 2 3
k
4
s
I
1 2 3 4
W o 1 2
CHAPTER 4 Troubleshooting and Fault Information
The VFD-L AC drive has a comprehensive fault diagnostic system that includes several different alarms and fault messages. Once a fault is detected, the corresponding protective functions will be activated. The following faults are displayed on the AC drive digital keypad. The six most recent faults can be read on the digital keypad display by viewing Pr.6-07 to Pr.6-12. NOTE: faults can be cleared by pressing the Reset key on the keypad or Input Terminal.
Common Problems and Solutions:
Faul
Nam
The AC drive detects an abnormal increase in current.
The AC drive detects that the DC bu voltage has exceeded its maximum allowable value.
The AC drive temperature sensor detects excessive heat.
The AC drive detects that the DC bu voltage has fallen below its minimum value.
nternal electronic overload trip
The external terminal EF-GND goes from OFF to ON. Motor overload. Check the parameter settings ( Pr.6-03 to Pr.6-05)
Fault Descriptions Corrective Actions
. Check whether the motors horsepower
corresponds to the AC drive output power.
. Check the wiring connections between the
AC drive and mot or for pos sible sh ort circuit s
. Increase the Acceleration time (Pr.1-09,
Pr.1-11).
. Check for possible excessive loading
conditions at the motor.
. If there are any abnormal conditions when
operating the AC drive after the short-circuit is removed, the drive should be sent back to manufacturer.
. Check whether the input voltage falls within
the rated AC drive input voltage. . Check for possible voltage transients. . Bus over-vo l ta ge m a y als o be ca used b y
motor regeneration. Increase the decel time . Ensure that the ambient temperature falls
within the specified temperature range. . Make sure that the ventilation holes are not
obstructed. . Remove any foreign objects on the heat sin
and check for possible dirty heat-sink fins. . Provide enou gh spa cin g fo r ade qua te
ventilation.
heck whether the input voltage falls within the
ated AC drive’s input voltage.
. Check for possible motor overload. . Check electronic thermal overload setting. . Increase motor capacity. . Reduce the current level so that the drive
output current does not exceed the value set by the Motor Rated Current Pr.7-00.
hen external terminal EF-GND is closed, the utput will be turned off. (under N.O. . Re duc e th e mo to r lo ad . . Adjust the over-torque detection setting to an
appropriate setting.
()
14
Faul
t
e
1 2 3 4
1 2
. 3 4
a
1 2 3
1 2
3
a
1 2 3
1 2
3
a
1 2
3 1
2 1 2
d 1
2
1
2 T
o
1 2
n
3 4
Nam
Over-current during acceleration:
. Short-circuit at motor output. . Torque boost too high. . Acceleration time too short. . AC drive output capacity is too
small.
Over-current during deceleration:
. Short-circuit at motor output. . Deceleration time too short. . AC drive output capacity is too
small. Over-current during steady state operation:
. Short-circuit at motor output. . Sudden increase in motor loading. . AC drive output capacity is too
small.
Fault Descriptions Corrective Actions
. Che ck fo r po ss ibl e poo r insu la ti on at th e
output line. . Decrease the torque boost setting in Pr.7-02 . Increase the acceleration time. . Replace with the AC drive with one that has
higher output capacity (next HP size). . Che ck fo r po ss ibl e poo r insu la ti on at th e
output line. . Increase the deceleration time. . Replace with the AC drive with one that has
higher output capacity (next HP size). . Che ck fo r po ss ibl e poo r insu la ti on at th e
output line. . Check for possible motor stall. . Replace with the AC drive with one that has
higher output capacity (next HP size). . Switch off power supply.
Internal memory IC can not be programmed.
Internal memory IC can not be read.
Drive’s internal circuitry abnormal.
Hardware protection failure Software protection failure
Auto accel/decel failure
Communication Error
Externa l Ba se B lo c k. AC drive output is turned off.
he AC drive detects excessive drive
utput current.
. Check whether the input voltage falls within
the rated AC drive input voltage. . Switch the AC drive back on. . Check the connections between the main
control board and th e powe r boa rd. . Reset drive to factory defaults. . Switch off power supply. . Check whether the input voltage falls within
the rated AC drive input voltage. Switch on
the AC drive.
eturn to the factory. eturn to the factory.
on’t use the function of auto acceleration/ eceleration. . Check the connection between the AC drive
and computer for loose wires.
. Check if the communication protocol is
properly set.
. When the externa l input te rmina l (B.B ) is
active, the AC drive output will be turned off.
. Disable this connection and the AC drive will
begin to work again. . Check whether the motor is overloaded. . Reduce torqu e compensatio n setti ng as se t i
Pr.7-02. . Increase the AC drive’s output capacity. .
Note:
of the rated current for a maximum of 60
The AC drive can withstand up to 150%
seconds.
15
V M
A R
)
R
M
s
R R
I
F C O
T
I
at
O A V S K
y
E
P
ut i c
K
E
communication port
M
h,
l
O
n,
Standard Specifications
oltage Class 115V 230V
odel Number VFD-
pplicable Motor Output (kW) 0.2 0.4 0.2 0.4 0.7 1.5
ated Output Capacity (KVA ated Output Current (A) 1.6 2.5 1.6 2.5 4.2 7.0
ax. Output Voltage (V)
Output Rating
ated Frequency (Hz) 1.0~400Hz ated Input Current (A) 6 9 4.9/1.9 6.5/2.7 9.7/5.1
nput voltage Tolerance
Power
Control
Operating Characteristics
requency tolerance
ontrol system SVPWM (Sinusoidal Pulse Width Modulation, carried frequency 3kHz~10kHz) utput Frequency Resolution
orque Characteristics
verload Endurance 150% of rated current for 1 minute
ccel/Decel Time 0.1~600Sec. (can be set individually)
Characteristics
/F pattern V/F pattern adjustable tall Prevention Level 20~200%, setting of Rated Current
Frequenc
Setting
Operation
Setting
Signal
Multi-function Input Signal
Multi-function Output Signa
Other Function
Protection
Installation Location Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust
L
eypad
xternal Signal
eypad Setting by RUN//STOP keys
xternal Signal
Other Including EMI Filter
Cooling Forced air-cooling
A/B 002 004 002 004 007 015
0.6 1.0 0.6 1.0 1.6 2.7
3-phase correspond
to double input
voltage
Single phase
90~132V 50/60Hz
ncluding the auto-torque, auto-slip compensation, starting torque can be 150%
otentiometer-5KΩ/0.5W, DC 0 ~ +10V (input impedance 47KΩ), 4~20mA (outp
mpedance 250Ω), multi-function inputs1 to 3 (3steps, JOG, UP/DOWN
ommand), communication setting
M0,M1,M2,M3 can be combined to offer various modes of operation, RS-485
ulti-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/decel switc
counter, PLC Operation, external Base Block (NC,NO) selection
AC Drive Operating, Frequency Attained, Non-zero speed, Base Block, Fault
Indication, Local/Remote indication, PLC Operation indication.
AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records,
Adjustable Carried Frequency, Starting Frequency Setting of DC Braking ,
ver-Current Stall Prevention, Momentary Power Loss restart, Reverse Inhibitio
Frequency Limits, Parameter Lock/Reset
Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal,
Three-phase corresponds to input voltage
Single / 3-phase
180~264V 50/60Hz
±
5%
0.1Hz
5 Hz
Setting by
Overheating, Self-t esting

keys or V.R
3-phase
180~264V
50/60Hz
Ì
/9
Ambient Temperature
Storage Temperature
Environment
Ambient Humidity Below 90%RH (non-condensing)
Vibration 9.80665m/s2(1G) less than 20Hz, 5.88m/s2 (0.6Gat) 20 to 50Hz
-10¬-40¬ (Non-Condensing and not frozen)
-20¬ to 60¬