English- 3
General Specifications
Control System SPWM(Sinusoidal Pulse Width Modulation) control (V/f or sensorless vector control)
The Resolution of
Frequency Setting and
Output Frequency
0.01Hz
Torque Characteristics
Including the auto-torque, auto-slip compensation; starting torque can be 150% at
1.0Hz
Overload Endurance 150% of rated current for 1 minute
Skip Frequency Three zones, settings range 0.1-400Hz
Accel/Decel Time 0.1 to 3600 seconds (4 Independent settings for Accel/Decel time)
Stall Prevention Level 20 to 250%, setting of rated current
DC Brake
Operation frequency 0.1-400.0Hz, output 0-100% rated current
Start time 0-60 seconds, stop time 0-60 seconds
Regenerated Brake
Torque
Approx. 20%(up to 125% possible with option brake resistor or brake unit externally
mounted, 1-15HP brake chopper built-in)
Control Characteristics
V/f Pattern Adjustable V/f pattern, 1.5 power curve, 1.7 power curve, square and cube curve
Keypad Setting by
Frequency
Setting
External
Signal
Potentiometer-5kΩ/0.5W, 0 to +10VDC; -10 to +10VDC, 4 to 20mA RS-485 interface;
Multi-Function Inputs 1 to 6 (15 steps, Jog, up/down)
Keypad Set by RUN, STOP and JOG
Operation
Setting
Signal
External
Signal
2 wires/3 wires (Fwd, Rev, EF), JOG operation, RS-485 serial interface (MODBUS),
process logic control
Multi-Function Input
Signal
Multi-step selection 0 to 15, Jog, accel/decel inhibit, first to forth accel/decel switches,
counter, PLC operation, external Base Block (NC, NO), auxiliary motor control is
invalid, ACI/AVI/AUI selections, driver reset, UP/DOWN key settings, sink/source
selection
Multi-Function Output
Indication
AC drive operating, frequency attained, non-zero, Base Block, fault indication,
local/remote indication, PLC operation indication, auxiliary motor output, driver is
ready, overheat alarm, emergency stop
Operating Characteristics
Analog Output Signal Output frequency/current/voltage/frequency command/speed/factor
Alarm Output Contact Contact will be On when it malfunctions (1 Form C contact or 3 open collector outputs)
Operation Functions
AVR, accel/decel S-Curve, over-voltage/over-current stall prevention, fault records,
reverse inhibition, momentary power loss restart, DC brake, auto torque/slip
compensation, auto tuning, adjustable carrier frequency, output frequency limits,
parameter lock/reset, vector control, counter, PG feedback control, PID control, fan &
pump control, external counter, PLC, MODBUS communication, abnormal reset,
abnormal re-start, power-saving, sleep/revival function, digital frequency output, fan
control, sleep/wake frequency, master/auxiliary frequency, 1st/2nd frequency source
selections
Protection Functions
Over voltage, over current, under voltage, under current, external fault, overload,
ground fault, overheating, electronic thermal, IGBT short circuit
Display Keypads
8-key, 7-segment LED with 5-digit, 8 status LEDs, master frequency, output frequency,
output current, custom units, parameter values for setup and lock, faults, RUN, STOP,
RESET, FWD/REV, JOG
Enclosure Rating IP20
Pollution Degree 2
Installation Location Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature -10oC to 40oC Non-Condensing and not frozen
Storage/ Transportation
Temperature
-20 oC to 60 oC
Ambient Humidity Below 90% RH (non-condensing)
Environmental Conditions
Vibration 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz