INST ALLATION AND OPERATING INSTRUCTIONS
FAN / LED LIGHT / LED NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is AC
120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the
Nation Electrical Code (NEC) and the Occupation Safety
and Healthy Act (OSHA).
3. Always disconnect the power source before working on or
near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot
surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are configured as shown
in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential usage
only.
10. Do not install this ventilating fan where air temperature
may exceed 40°C (104°F).
Turning angle too large Duct shrink
and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and local code authorities.
5. When cutting or drilling into wall or ceiling, do not d amage
electrical wiring and other hidden utilities.
6. Ducted ventilating fan must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) – protected
branch circuit.
8. Do not use this unit with any other solid-state control
device. Solid-state controls may cause harmonic distortion,
which can cause motor humming noise.
9. NEVER place a switch where it can be reached from a tub
or shower.
10. Not to be installed in a ceiling thermally insulated to a
value greater than R40. (This is required for installation in
Canada only)
11. Do not open/disassemble the LED light engine or tear off
the warranty label for protect the life and performance.
CAUTION
Too many elbows Elbow near the body
Body
Fig. A
1. To reduce the risk of electric shock, please disconnect the
electrical supply circuit to the fan before installing
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. Not for use in cooking area. (Fig. B)
4. This product must be properly connect to the grounding
conductor of the supply circuit.
WARNING
MODEL VFB080D4LED1
e 1.
light kit.
Cooking area
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
Fig. B
1. Choose the installation type according to the fig as below:
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
(Include LED
Light Engine)
Long Screw
Suspension
bracketⅠ
(6.10 inch)
Suspension
bracketⅡ
(11.81 inch)
Suspension
bracketⅢ
(13.98 inch)
(M4×25)
Screw
(M4×12)
1
6
3
1
Spacing A on center joists Insert Suspension bracket Suspension bracket No.
12.0 inch Refer to Fig B-01, B-02 I,II
16.0 inch Refer to Fig B-03, B-04 I,II,III
19.2 inch Refer to Fig B-03, B-04 I,II,III
24.0 inch Refer to Fig B-03, B-04 I,II,III
1-1 TypeⅠ-12 inches between joists
1
1
INSTALLATIONS
A. Install with wood frame
MODEL VFB080D4LED1
e 2.
12.0
Joist Joist
B-01
Model No. VFB080D4LED1
Install Dim. (in.)
10.2 ╳ 10.2
1. Body installation
1-1. Construct the wood frame(not provided) with 30mm square
bar and attach it to the ceiling joist.
1-2. Attach the duct connector to the wood frame with taping
screw.
Duct connector
Wood frame
Wood frame
Taping screw
1-3. Insert the body into the wood frame and connect it to the
duct connector. Secure the body on wood frame with taping
screws.
Main Body
Joist
Screw M4×12
Suspension Bracket I
Long Screw(M4×25)
Joist
1-1.1 Insert the suspension bracketⅠ into the bracket cover of
adaptor side and select one of suspension bracketⅡ of the
back of the fan body.
1-1.2 Insert the fan between joists. Make sure the fan body is
level and perpendicular with the joist.
1-1.3. Ensure the distance between ceiling and fan body for the
thickness of grille.
1-1.4 Secure the all suspension bracket to joists by using
tapping screw on the tab.
1-1.5 Secure the suspension bracket I and II to fan body by
using screw(M4×12-2pce each).
1-2 T y peⅡ-16/19.2/24 inches between joists
Tab
Suspension Bracket II
B-02
B. Install with joist
Long Screw(M4×25)