Delta VFB080D4H1 User Manual

ITEM #809721
HUMIDITY SENSING
BATH FAN
MODEL VFB080D4H1
TABLE OF CONTENTS
Package Contents 2
General Safety Information 3
Preparation and Wiring Diagrams 4
Assembly Instructions - New Construction 5
Assembly Instructions - Existing Construction 6
Grille Installation 8
Humidity Sensing Fan Operation 8
Care and Maintenance 9
Troubleshooting 10
Dimensions 11
Warranty 12
READ AND SAVE THESE INSTRUCTIONS
Address: 4405 Cushing Parkway, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
Scan here for product video
PACKAGE CONTENTS
PART DESCRIPTION QTY
1
2
Fan Body 1
Grille 1
1
3
4
5
6
HARDWARE CONTENTS
(Images are to scale)
Suspension Bracket I 1
Suspension Bracket II 1
Suspension Bracket III 1
Duct Connector 1
2
A
Long Wood Screw ( 4 x 25)
3
B
X 4
X 3
Short Machine Screw (M4 x 12)
4
5
6
Model: VFB080D4H1
2
GENERAL SAFETY INFORMATION
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Minimum 18 in.
READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. shown in Fig.A.
7. Provide suction parts with proper ventilation.
8. This unit is UL Listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
6. Ducted ventilating fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) – protected branch circuit.
8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a tub or shower.
10. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only).
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Minimum 18 in.
Fig. A
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig.B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at
4.
burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
Cooking area
Do not install above or
inside this area
4
5
4
Cooking
Equipment
°
floor
Fig. B
3
Model: VFB080D4H1
PREPARATION
Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits
WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton.
Check area above installation location to be sure that wiring can run to the planned location and that duct
proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
You may need the help of a second person to install this fan: one person on the attic side and one on the room side.
Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. However, most are available at y our loc al home improvement or hardware store.
DIMENSION REQUIREMENTS
Roof cap (with built-in
or
damper)
Wall cap (with built-in damper)
Short piece of flexible duct helps alignment and absorbs sound
Fan housing
Seal gap around housing
Caulk termination to duct
Proper insulation around the fan to minimize building heat loss and gain. Locate unit above (GFCI-protected circuit required) or within 5 feet of the shower head. Locate unit away from heating or cooling sources which can affect humidity levels. Do not locate near window. Unit may respond to the outdoor humidity level. Unit must be installed in ceiling to properly sense moisture.
proper sensing. The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed. Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Ceiling
Opening (L)
Ceiling
Opening (W)
10.25 in. 10.25 in. 8.5 in.
WIRING DIAGRAM
JUNCTION BOX
BLACK
WHITE
GREEN
Model: VFB080D4H1
SWITCH BOX
OFF
ON
POWER SWITCH
Ceiling
Opening (H)
L
N
GRD
Housing
Dimension (L)
9.68 in. 9.68 in. 7.98 in.
ON/OFF SWITCH
(purchase separately)
POWER SWITCH
4
SWITCH BOX
120 VAC
LINE IN
Housing
Dimension (W)
BLACK WHITE
GROUND
(bare)
WIRING