IMPORTANT SAFEGUARDS
- After unpacking, make sure the appliance is complete and undamaged. If in doubt, do not use and consult a qualified electrician.
- Before plugging the appliance into the mains electricity supply, make sure the mains voltage corre­sponds to the voltage indicated on the rating element.
- If the power cable is damaged, it must be replaced by the manufacturer, an authorised service cen­tre or a qualified electrician in order to eliminate all risk.
- This appliance must be used exclusively for the purpose for which it was expressly conceived, na­mely as a domestic humidifier. Any other use is considered improper and thus dangerous. Improper, incorrect or irresponsible use and/or repairs performed by unqualified personnel absolve the manufacturer from all liability for resulting damage.
- The appliance must not be used by young children or unfit persons without adequate supervision.
- Do not allow children to play with the appliance.
- The inside of this appliance may become extremely hot. You should therefore take maximum care when using the appliance.
- Do not remove the tank or move the appliance while in operation. Always wait at least 15 minutes after turning off and unplugging from the mains.
- Never use the humidifier without water. Use tap water only without any additives. Always fill the tank with the appliance off.
- Do not move the humidifier when the tank is full or the appliance is in operation
- Do not leave the appliance turned on unnecessarily as it could represent a hazard.
- Never place the hands, face or body directly above or near the mist discharge grill while the ap­pliance is in operation.
- Place the appliance on a stable level surface. Never place it on carpet or rugs or on delicate furnitu­re as they could be damaged by contact with water or mist.
- Do not place the humidifier near heat sources such as heaters, radiators etc. Position it near a power socket. For optimum operation, position the humidifier at least 10 cm from the wall. Make sure the mist discharged from the grill is not directed against the wall. This could cause da­mage, particularly to wallpaper.
- When the appliance is plugged into the mains, always respect the following fundamental safety ru­les:
- never touch the appliance with damp or wet hands;
- do not use the appliance with bare or damp feet;
- do not pull the power cable or appliance itself to unplug from the mains;
- keep the appliance out of reach of children;
- do not insert foreign bodies into the appliance;
- protect the appliance from atmospheric agents and do not use out of doors;
- do not obstruct the mist discharge grill.
- If the appliance is to be disposed of definitively, after unplugging from the mains socket, you are recommended to remove the power cable to make it unusable.
- Before cleaning or maintenance of any sort, always unplug the appliance from the mains socket.
- In the event of breakdown and/or malfunction, turn the appliance off. Do not attempt to repair it. For all repairs, contact authorised service centres only and insist on the use of original spare parts and accessories.
- Before use, always check that the power cable is undamaged.
- Keep the sensor dry and never immerse in water.
- Excessive humidity in the room may lead to the formation of condensation on windows and furni­ture. If this occurs, turn the humidifier off ;
KEEP THIS BOOKLET IN A SAFE PLACE FOR FUTURE CONSULTATION.
4
GB
READ THIS BOOKLET CAREFULLY BEFORE USING THE APPLIANCE. THIS IS THE ONLY WAY TO ENSURE BEST RESULTS AND MAXIMUM SAFETY.
5
DESCRIPTION A) Mist discharge grill with cup for
perfumes and medication
B) Protective cover C) Water tank D) Base E) Control panel F) Humidity sensor G) Water conduit H) Evaporation element
Model UH700M I) ON/OFF/humidistat selector L) "No water" light M) "Appliance on" light N) "Power on" light
Model UH800E O) Display P) Button to increase relative humidity Q) Button to reduce relative humidity R) Maximum and minimum power se-
lector button
S) Restart button T) ON/OFF button
The humidifier tank contains about 6 litres of water for about 26 hours operation.
BEFORE USING
NOTE: When you unpack your humidifier, you may find water marks. This is nor-
mal as each appliance is tested before sale.
1.Make sure the appliance is unplugged.
2.Place on a stable surface.
3.To fill the tank, turn it upside down and remove the cap by turning clockwise. Fill with fresh clean water then close by rotating the cap clockwise. Make sure it is ti­ghtly closed.
4.Make sure the evaporator element is clean and free from foreign bodies.
5.Position the tank correctly on the base.
6.Plug into the mains socket.
INSTRUCTIONS
Position the tank on the base and plug the appliance into the mains socket. The hu­midifier is now ready for use.
Model UH700M
Turn the ON/OFF/humidistat selector (I) to one of the positions between OFF and MAX.
TECHNICAL SPECIFICATIONS
MODEL UH 700M UH 800E Tank capacity 6 litres 6 litres Absorbed power
see rating plate see rating plate
Mist discharge levels 12 Automatic shutdown ** "No water" light ** Teflon-coated evaporator element ** Vaporiser for perfumes or medicinal substances ** Size: (LxDxH) 33x20,6x35,4 cm 33x20,6x35,4 cm