Warnings
This appliance is designed for home air conditioning and must not be used for other purposes.
It is dangerous to modify or alter the characteristics of the appliance in any way.
•The appliance must be installed in conformity with legislation in force in the country concerned.
If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.
This air conditioning unit must be used by adults only. Never allow children to play with the applian­ce.
This appliance is designed for home air conditioning and must not be used for other purposes.
Do not allow children to play with the appliance.
•The appliance must be connected to an efficient earth system.
Have your electrical circuit checked by a qualified electrician.
Do not use extension cables.
Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
Do not move the appliance by pulling the power cable.
Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
Do not rest heavy or hot objects on top of the appliance.
•Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioning unit.
Always transport the appliance upright or resting on one side.
•Use the appliance as described in this instruction manual only.
•As with any electrical appliance, while the instructions aim to cover as many eventualities as possible, caution and common sense should be used when operating and installing this air conditioning unit.
•At the end of its working life, take the appliance to a special collection centre.
The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers.
When putting the appliance away, do not cover with plastic bags.
The refrigerant gas R407c conforms to EC regulations on the environment.
•Avoid perforating the refrigerant circuit of the appliance.
Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (e.g. aerosol cans).
DESCRIPTION 1
air outlet grille
2 control panel 3 castors 4 handles 5 evaporator air intake grille 6 air exhaust hose housing 7 condenser air intake grille 8 drain hose cover 9 power cable 10 flange cap 11 air exhaust hose
12 window outlet 13 suckers 14 castor locks 15 remote control unit (model L30/L40only)
20
D
uring the summer, you feel comfortable at a temperature of between 24 and 27° C with a relative humidity of about 50%. An air conditioning unit removes excess moisture and heat from the room where it is located. Compared with installed models, portable air conditioning units have the advantage that they can be moved from one room to another in the home or be transported from one building to another.
Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re-emitted into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside.
In models with case (Super­Pinguino), the circuit is cooled using air from outsi­de. All Pinguino and SuperPin­guino models can also be used in fan-only mode.
What are the Pinguino and SuperPinguino?
21
ENGLISH
The instructions below will enable you to prepare your air conditioning unit for operation as effi­ciently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with Pinguino:
Fit the air exhaust hose in the housing
at the back of the appliance. Insert it as
shown in figure A.
6
11
If you have a double window, use the suckers provided to hold the two parts of the window together (fig. C).
13
Fit the window outlet to the end of the hose .
Place the air conditioning unit near a win­dow or French window.
Make sure the air exhaust hose is unob­structed.
Open the window or French window sligh­tly and position the outlet as shown in figure B.
12
12
11
A
Preparing for use
B
C
Keep air hoses as short and free of cur­ves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
the mains socket and electrical circuit are adequate for the appliance;
the mains socket matches the plug. If this is not the case, have the plug replaced;
the mains socket is adequately earthed. Failure to follow these important safety instructions absolves the
manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
22
Preparing for use
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently (Fig. D).
Fit the flange accessory provided in the hole
Fit the hose in the housing at the back of the appliance (fig. A page 21).
Fit the end of the hose to the flange
as shown in fig. F.
10
11
11
10
Proceed as follows:
Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure E.
30 cm
30 cm
106
MAX100 cm
MIN 35
c
When the hose is not fitted, the hole can
be closed with the flange cap .
NOTE. When installing the air conditioning unit semi­permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
10
11
in the window pane
in the wall: you are recommended to insulate the sec­tion of wall using suitable insulation.
in the woo­den kick­board of a French win­dow
E
F
Keep the air hoses as short and free of curves as possible to avoid constrictions.
D
23
ENGLISH
Control panel L10/L15/L20H
DESCRIPTION OF THE CONTROL PANEL
A ON/OFF button B Mode selection button
Conditioning, fan, heating (L20H only).
C Air conditioning mode indicator light D Fan mode indicator light E Heating mode indicator light (L20H only) F Increase temperature/ programmed operating time button GTimer in operation indicator light H Display Displays the temperature values set and the programmed operating time I Reduce temperature/humidity/programmed operating time button L/M/N/O Fan speed and AUTO mode indicator lights P Fan speed selection button QTimer button
B A
C
D
E
GH
M
I
N
O
F
QP
THE CONTROL PANEL
MODELS L10/ L15/L20H
L
Loading...
+ 10 hidden pages