DeLonghi Pinguino PAC 36 Instructions For Use Manual

15
Instructions for use
Air-conditioner
PAC 36
16
Please read this instruction booklet carefully before installing and using the appliance. In this way, you will obtain the best possible results and maximum operating safety. In particular, refer to the safety warnings on page 24.
INTRODUCTION
The new PAC 36 is a highly versatile electronically­controlled air-conditioner: it can be used as a manual or automatic air-conditioner during the summer.
This conditioner consists of two units: the internal unit is designed to operate inside the room to be conditioned; the external unit is installed in the open. The two units are connected by a special hose, approximately 3,5 metres in length. This hose contains the freon tubes, the electrical wiring and the condensation discharge tube.
This appliance also has a SLEEP function. This function activates a program studied and designed to increase comfort during sleeping hours. The program not only ensures perfect silence (from both the internal and external units) but also controls the temperature of the environment, without lowering it excessively, to produce the healthiest conditions.
TECHNICAL DATA
Power supply voltage see rating label Maximum input power (air-conditioning mode) see rating label Cooling capacity* see rating label Fan speeds 2 Maximum air flow 560 m3/h Timer 24 h Length of hose 3500 mm Tube size 20 x 44 mm Dimensions (internal unit):
• width 560 mm
• height 735 mm
• depth 355 mm
• weight 44 kg
Dimensions (external unit):
• width 450 mm
• height 470 mm
• depth 210 mm
• weight 14 kg
* Standard conditions:
Room temperature 27°C
47% relative
humidity
External temperature 35°C
41% relative
humidity
Temperature during night
Temperature
60 min. 120 min.
Time
IDEAL OPERATING CONDITIONS
Room temperature 21 ÷ 32°C
External temperature 21 ÷ 43°C
17
DESCRIPTION
INTERNAL UNIT
Condensation discharge tube
Castors
Power cable
Rear panel
Carrying handle
Removable filter
Power cable
Air intake grille
INTERNAL UNIT
Connection hose
Air outlet grid
Control panel
Control panel cover
EXTERNAL UNIT
18
ACCESSORIES
ILLUSTRATION NUMBER SUPPLIED
2
4
4
2
1
2
1
4
DESCRIPTION
Wall bracket
Screws + wall plugs (Ø 6mm)
Nut and bolt (Ø 5mm)
Support belt with hook
Frame for connector hose
Castor stop
Condensation drainage coupling
Castors for external unit and washers
This appliance is fitted with a special HE (High Efficiency) system for extra-low energy consumption. When the unit is switched on, this system requires about 4 minutes before cold air is generated.