GENERAL DESCRIPTION
The PAC 30 ELECTRONIC is an extremely versatile air-conditioner, performing its air cooling function
through either water condensation or air condensation.
The user can choose between the two functions:
1) WATER FUNCTION - For economical, highly efficient and rapid air cooling. This function is
recommended when the appliance is first switched on and the environment is particularly hot.
2) AIR FUNCTION - For less intense cooling. A more convenient function (no need to fill water container).
The versatility of this appliance is demonstrated by its ability to switch automatically to air function
whenever the water container is empty.
The PAC 30 ELECTRONIC can also be used as a heater during the winter months.
The PAC 30 ELECTRONIC sets the temperature automatically.
TECHNICAL DATA Tab.1
IDEAL OPERATING CONDITIONS
(AIR-CONDITIONING FUNCTION) Tab.2
ROOM TEMPERATURE 21 ÷ 32°C
FREQUENCY see rating label
POWER SUPPLY
VOLTAGE see rating label
ROOM HUMIDITY FACTOR BELOW 80%
WATER FUNCTION - AIR FUNCTION
Power supply voltage (V) see rating label
Frequency (Hz) "
* Cooling capacity (Frig/h, W, Btu/h) "
Cooling capacity (Frig/h, W, Btu/h) "
Electric power consumption (A) "
Max.power consumption (air-condit.mode) (W) "
Max.power consumption (heating mode) (W) "
Air flow capacity (m3/h) 360
Timer 24 h
Dimensions: width (mm) 560
height 725
depth 365
Net weight (kg) 44
Technical data subject to change without prior notice
* According to standard ASHRAE 128P
NB. When indoor temperature exceeds 32°C, the appliance should be operated with water.

20
DESCRIPTION OF MAIN FEATURES
Tab.3
Air outlet grid
Control panel
Programmer (timer)
Water container
Castors
Castor stops
Water collecting tray
Water container compartment
door
Air filter
Air intake grid
Warranty envelope
Exhaust hose compartment
Power cable compartment
Handle
Water collecting tray
drainage tube

21
DESCRIPTION OF ACCESSORIES Tab.4
PARTS
SUPPLIED
DESCRIPTION
Exhaust hose
Stopper + flange
Castor stop
De-scaling fluid
Window nozzle
Suction cup set
1
1
2
1
1
1
ACCESSORY CHECK
Check that all parts listed in Table 4 are included.

22
Ø 98 mm (3" 3/4)
INSTALLATION FOR AIR-CONDITIONING FUNCTION
Our air-conditioner is portable and versatile: it
can be used as a permanent installation or wise
easily moved from one room to another.
The appliance must be fitted at least 30 cm.
from the surrounding walls.
When installed permanently, all air discharged from the rear hose is extracted from the room in which the
PAC 30 ELECTRONIC is installed.
Check that the room (particularly if it is small) is not “air-tight”; a drop in pressure could cause a malfunction
and thereby activate the safety switch. Air entering the room through door and window cracks is normally
sufficient. If necessary, leave a door slightly ajar (a gap of approx.1 cm. is adequate).
The unit can also be used as a “temporary”
installation for use in any room with a window or
french window; this “temporary” installation can
be used at any time until it is ready for permanent
instalment.
N.B.: In either case, check that the unit is resting
on at “perfectly level” surface. If necessary, use
the 2 castor stops for the front castors.
A1
in a window pane
A2 through the wooden
base-section of a glass door
A3
in the wall
Permanent installation
The outlet holes must be connected to the outside of the building and cannot be made in any wall or panel.
30 cm
30 cm
30 cm