DeLonghi Pinguino PAC 30 ELECTRONIC Instruction Manual

18
Dear Sir/Madam We thank you for purchasing this Pinguino
appliance and congratulate you on your wise choice.
Please make the time and effort to read this manual carefully.
We hope that the Pinguino will become a welcome friend this summer, a source of comfort and refreshment.
Best wishes De Longhi S.p.A.
19
GENERAL DESCRIPTION
The PAC 30 ELECTRONIC is an extremely versatile air-conditioner, performing its air cooling function through either water condensation or air condensation.
The user can choose between the two functions:
1) WATER FUNCTION - For economical, highly efficient and rapid air cooling. This function is recommended when the appliance is first switched on and the environment is particularly hot.
2) AIR FUNCTION - For less intense cooling. A more convenient function (no need to fill water container).
The versatility of this appliance is demonstrated by its ability to switch automatically to air function whenever the water container is empty. The PAC 30 ELECTRONIC can also be used as a heater during the winter months. The PAC 30 ELECTRONIC sets the temperature automatically.
TECHNICAL DATA Tab.1
IDEAL OPERATING CONDITIONS (AIR-CONDITIONING FUNCTION) Tab.2
ROOM TEMPERATURE 21 ÷ 32°C
FREQUENCY see rating label
POWER SUPPLY
VOLTAGE see rating label
ROOM HUMIDITY FACTOR BELOW 80%
WATER FUNCTION - AIR FUNCTION Power supply voltage (V) see rating label Frequency (Hz) " * Cooling capacity (Frig/h, W, Btu/h) " Cooling capacity (Frig/h, W, Btu/h) " Electric power consumption (A) " Max.power consumption (air-condit.mode) (W) " Max.power consumption (heating mode) (W) " Air flow capacity (m3/h) 360 Timer 24 h Dimensions: width (mm) 560
height 725 depth 365
Net weight (kg) 44
Technical data subject to change without prior notice
* According to standard ASHRAE 128P
NB. When indoor temperature exceeds 32°C, the appliance should be operated with water.
20
DESCRIPTION OF MAIN FEATURES
Tab.3
Air outlet grid Control panel Programmer (timer)
Water container
Castors Castor stops
Water collecting tray
Water container compartment door
Air filter
Air intake grid Warranty envelope
Exhaust hose compartment
Power cable compartment
Handle
Water collecting tray drainage tube
21
DESCRIPTION OF ACCESSORIES Tab.4
PARTS
SUPPLIED
DESCRIPTION
Exhaust hose
Stopper + flange
Castor stop
De-scaling fluid
Window nozzle
Suction cup set
1
1
2
1
1
1
ACCESSORY CHECK
Check that all parts listed in Table 4 are included.
22
Ø 98 mm (3" 3/4)
INSTALLATION FOR AIR-CONDITIONING FUNCTION
Our air-conditioner is portable and versatile: it can be used as a permanent installation or wise easily moved from one room to another.
The appliance must be fitted at least 30 cm. from the surrounding walls.
When installed permanently, all air discharged from the rear hose is extracted from the room in which the PAC 30 ELECTRONIC is installed. Check that the room (particularly if it is small) is not “air-tight”; a drop in pressure could cause a malfunction and thereby activate the safety switch. Air entering the room through door and window cracks is normally sufficient. If necessary, leave a door slightly ajar (a gap of approx.1 cm. is adequate).
The unit can also be used as a “temporary” installation for use in any room with a window or french window; this “temporary” installation can be used at any time until it is ready for permanent instalment.
N.B.: In either case, check that the unit is resting on at “perfectly level” surface. If necessary, use the 2 castor stops for the front castors.
A1 in a window pane
A2 through the wooden
base-section of a glass door
A3 in the wall
Permanent installation
The outlet holes must be connected to the outside of the building and cannot be made in any wall or panel.
30 cm
30 cm
30 cm
Loading...