CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the
problem.
User
Accessible
for external
data
Remedial Action (Action
necessary to prevent loss of
data)
Embedded
Flash in
embedded
controller
MEC1641
Embedded Flash –
288KB user space, 32-bit Access,
10K cycles Endurance.
Embedded
Flash in
embedded
controller
MSP430
Embedded Flash –
NV-RAM 8KB user space. Single
bit write.
Embedded
Flash in
sensor
controller
STM32F10
3CBU6
Embedded Flash –
NV-RAM 128KB user space for
programing.
Embedded
Flash in
TPM
controller
AT97SC32
04
Embedded Flash –
NV-RAM 1280 Bytes user space
for programing.
Non Volatile memory, 64K
bytes.
Non Volatile memory, 16 MB,
System BIOS and Video BIOS
for basic boot operation, PSA
(on board diags), PXE diags.
System
Memory –
LP-DDR3
memory
On board
memory
solution.
U1601,
U1602,
U1701,
1.2V LP-DDR3 SDRAM
device is a low-current self
refresh version of the 1.2V LPDDR3 SDRAM device.
Statement of Volatility – Dell Venue 11 Pro-7130/7139
The Dell Venue 11 pro contains both volatile and non-volatile (NV) components. Volatile components lose their data
immediately after power is removed from the component. Non-volatile (NV) components continue to retain their data even
after power is removed from the component. The following NV components are present on the Dell Venue 11 pro system
board.
Table 1. List of Non-Volatile Components on System Board
Month yyyy
User
Accessible
for external
data
Remedial Action (Action
necessary to prevent loss of
data)
System
Memory –
DDR3LRS
memory
On board
memory
solution.
U1501,
U1502,
U1601,
U1602,
1.35 V DDR3L-RS SDRAM
device is a low-current selfrefresh version of the 1.35 V
DDR3L SDRAM device. Total
4GB and 8GB versions are
used in Venue 11 pro.
Non Volatile memory, 256
Bytes of Battery-backed
SRAM.
Stores CMOS information.
Non-Volatile magnetic media,
various sizes in
64,128,256GB. Types are all
also SSD (solid state flash
drive) solutions.
CAUTION: All other components on the system board lose data if power is removed from the system. Primary power
loss (unplugging the power cord and removing the battery) destroys all user data on the memory (DDR3, 1067 MHz).
Secondary power loss (removing the on-board coin-cell battery) destroys system data on the system configuration
and time-of-day information.
______________
© 2013 Dell Inc.
Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™,
OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core™ and Celeron® are
registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™, and
AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, MS-DOS® and Windows Vista® are
either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat Enterprise Linux® and
Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® is a registered trademark and SUSE ™
is a trademark of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®,
Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries.
VMware®, Virtual SMP®, vMotion®, vCenter®, and vSphere® are registered trademarks or trademarks of VMWare, Inc. in the United States or other
countries.