Dell R310 User Manual

Dell™ PowerEdge™ R310
Systems
Getting Started
With Your System
Guide de mise en route
Primeiros passos com o sistema
Procedimientos iniciales con el sistema
Dell™ PowerEdge™
Getting Started
With Your System
Regulatory Model: E07S Series Regulatory Type: E07S002
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
WARNING: A WARNING indicates a potential for property damage,
personal injury, or death.
____________________
Information in this document is subject to change without notice. © 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.;
Intel and Pentium are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of
Microsoft Corporation in the United States and/or other countries; Red Hat and Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and other countries; SUSE is a registered trademark of Novell, Inc. in the United States and other countries; VMware and vSphere are registered trademarks or trademarks (the “Marks”) of VMware, Inc. in the United States and/or other jurisdictions; Citrix and XenServer are trademarks of Citrix Systems, Inc. and/or more of its subsidiaries, and may be registered in the United States Patent and Trademark Office and in other countries. Sun and Solaris are trademarks of Sun Microsystems, Inc. or its subsidiaries in the United States and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Regulatory Model: E07S Series Regulatory Type: E07S002
January 2010 P/N K086K Rev. A00

Installation and Configuration

WARNING: Before performing the following procedure, review the safety
instructions that came with the system.

Unpacking the System

Unpack your system and identify each item.

Installing the Rails and System in a Rack

Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.
Getting Started With Your System 3
Optional – Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.

Connecting the Power Cable(s)

Connect the system's power cable(s) to the system and, if a monitor is used, connect the monitor's power cable to the monitor.
4 Getting Started With Your System

Securing the Power Cables

Bend the system power cables into a loop as shown in the illustration and secure the cables to the brackets using the provided strap. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).

Turning On the System

Press the power button on the system and on the optional monitor if used. The power indicators should light.
Getting Started With Your System 5

Installing the Optional Bezel

Install the bezel (optional).

Complete the Operating System Setup

If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.
6 Getting Started With Your System

Supported Operating Systems

Microsoft® Windows® Small Business Server 2008 Standard and Premium ( x64) editions
Microsoft Windows Essential Business Server 2008 Standard and Premium ( x64) editions
Microsoft Windows Essential Business Server 2008 Premium ( x86) edition
Windows Web Server 2008 (x86) with SP2
Windows Server 2008 Standard and Enterprise (x86) editions with SP2
Windows Server 2008 Standard and Enterprise (x64) editions with SP2
Windows Server 2008 R2 Standard and Enterprise (x64) editions with SP2
Windows Web Server 2008 R2 (x86) with SP2
Windows Web Server 2003 (x86) with SP2
Windows Server 2003 R2 Standard and Enterprise (x86) editions with SP2
Windows Server 2003 R2 Standard and Enterprise (x64) editions with SP2
®
•Red Hat
Red Hat Enterprise Linux ES AP (Version 4.8) (x86)
Red Hat Enterprise Linux Server (Version 5.3) (x86_64)
Red Hat Enterprise Linux Server (Version 5.3) (x86)
•SUSE
•SUSE
•Citrix
•VMware
VMware ESX (Version 4.0) Update 1
VMware ESXi (Version 3.5) Update 5
VMware ESX (Version 3.5) Update 5
Sun™ Solaris™ 10 Update 10
Enterprise Linux® ES AP (Version 4.8) (x86_64)
®
Linux Enterprise Server 11 (x86_64)
®
Linux Enterprise Server 10 (x86_64) with SP3
®
XenServer™ Enterprise (Version 5.6)
®
ESXi (Version 4.0) Update 1
NOTE: For the latest information on supported operating systems,
see support.dell.com.
Getting Started With Your System 7

Other Information You May Need

WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document or as a separate document.
The rack documentation included with your rack solution describes how to install your system into a rack.
•The
Any media that ships with your system that provides documentation and
Hardware Owner’s Manual
features and describes how to troubleshoot the system and install or replace system components. This document is available online at
support.dell.com/manuals
tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
provides information about system
.

Obtaining Technical Assistance

If you do not understand a procedure in this guide or if the system does not perform as expected, see your Hardware Owner’s Manual. Dell™ offers comprehensive hardware training and certification. See www.dell.com/training for more information. This service may not be offered in all locations.
8 Getting Started With Your System

Technical Specifications

Processor
Processor type Intel
Expansion Bus
Bus type PCI Express Generation 2
Expansion slots One x16 half-length slot
Memory
Architecture 1066-MHz and 1333-MHz registered parity and
Memory module sockets Six 240-pin
Memory module capacities 1 GB, 2 GB, 4 GB, and 8 GB (RDIMMs only)
Minimum RAM 1 GB
Maximum RAM 32 GB
Drives
Hard drives Up to four 3.5" hot-swappable SAS or
Optical drive One optional internal slimline SATA
®
Xeon® processor 3400 series or Intel Core™ i3 processor, or Intel Pentium
One x8 half-length slot
®
processor
NOTE: Both the slots support x8 routing.
non registered DDR-III memory modules
SATA drives
or
Up to four 3.5" cabled SAS or SATA internal drives
or
Up to four 2.5" hot-swappable SAS or
2.5" SSD drives
DVD-ROM or DVD+/-RW drive
NOTE: DVD devices are data only.
Optional external USB DVD-ROM
Getting Started With Your System 9
Connectors
Back
NIC
Serial
USB
Video
Front
Video
USB
Internal
USB
Video
Video type Matrox G200, integrated in BMC
Video memory 8 MB graphics memory
Power
AC power supply (per power supply)
Wa t ta g e
Vo lt ag e
Heat dissipation
Maximum inrush current
Batteries
System battery
Two RJ-45 (for integrated 1-GB NICs)
9-pin, DTE, 16550-compatible
Two 4-pin, USB 2.0-compliant
15-pin VGA
15-pin VGA
Two 4-pin, USB 2.0-compliant
Two 4-pin, USB 2.0-compliant
350 W (non-redundant power supply)
400 W (redundant power supply)
100–240 VAC, 50/60 Hz
1571 BTU/hr maximum (non-redundant power supply)
1666 BTU/hr maximum (redundant power supply)
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 A per power supply for 10 ms or less.
CR 2032 3.0-V lithium coin cell
10 Getting Started With Your System
Physical
Height 4.29 cm (1.69 in)
Width 43.4 cm (17.09 in)
Depth 61.26 cm (24.12 in)
Weight (maximum configuration) 15 kg (33.02 lbs)
Weight (empty configuration) 5.96 kg (13.12 lbs)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
–40° to 65°C (–40° to 149°F) with a maximum temperature gradation of 20°C per hour
8% to 85% (noncondensing) with a maximum humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Getting Started With Your System 11
Environmental (continued)
Altitude
Operating
Storage
Airborne Contaminant Level
Class
–16 to 3,048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)
G2 or lower as defined by ISA-S71.04-1985
12 Getting Started With Your System
Systèmes Dell™
PowerEdge™ R310

Guide de mise en route

Modèle réglementaire : Série E07S Type réglementaire : E07S002
Remarques, précautions et avertissements
REMARQUE : Une REMARQUE indique des informations importantes qui peuvent
vous aider à mieux utiliser votre ordinateur.
PRÉCAUTION : Une PRÉCAUTION vous avertit d'un risque de dommage matériel
ou de perte de données en cas de non-respect des instructions données.
AVERTISSEMENT: Un AVERTISSEMENT vous avertit d’un risque
d'endommagement du matériel, de blessure corporelle ou de mort.
____________________
Les informations contenues dans ce document sont sujettes à modification sans préavis. © 2010 Dell Inc. Tous droits réservés.
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Inc. est strictement interdite.
Marques mentionnées dans ce document : Dell, le logo DELL et PowerEdge sont des marques de Dell Inc. ; Intel et Pentium sont des marques déposées d'Intel Corporation aux États-Unis et dans d'autres pays ; Microsoft, Windows et Windows Server sont des marques ou des marques déposées de Microsoft Corporation aux États-Unis et/ou d'autres pays ; Red Hat et Enterprise Linux sont des marques déposées de Red Hat, Inc. aux États-Unis et dans d'autres pays ; SUSE est une marque déposée de Novell, Inc. aux États-Unis et dans d'autres pays ; VMware et vSphere sont des marques ou des marques déposées (les “marques”) de VMware, Inc. aux États-Unis et/ou dans d'autres juridictions ; Citrix et XenServer sont des marques de Citrix Systems, Inc. et/ou de ses filiales et peuvent être déposées auprès de l'organisme United States Patent and Trademark Office aux États-Unis et dans d'autres pays. Sun et Solaris sont des marques de Sun Microsystems, Inc. ou de ses filiales aux États-Unis et dans d'autres pays.
D'autres marques commerciales et noms de marque peuvent être utilisés dans ce document pour faire référence aux entités se réclamant de ces marques et de ces noms ou de leurs produits. Dell Inc. dénie tout intérêt propriétaire vis-à-vis des marques et des noms de marque autres que les siens.
Modèle réglementaire : Série E07S Type réglementaire : E07S002
Janvier 2010 N/P K086K Rév. A00

Installation et configuration

AVERTISSEMENT: Avant d'exécuter la procédure ci-dessous,
lisez les consignes de sécurité fournies avec le système.

Déballage du système

Sortez le système de son emballage et identifiez chaque élément.

Installation des rails et du système dans un rack

Assemblez les rails et installez le système dans le rack en suivant les consignes de sécurité et les instructions d'installation du rack fournies avec votre système.
Guide de mise en route 15
Loading...
+ 37 hidden pages