Dell PowerEdge M IO Aggregator Getting Started Guide

Dell PowerEdge FN 410S I/O Aggregator Getting Started Guide
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2014 - 03
Rev. A00
Contents
1 About this Guide........................................................................................................5
2 Introduction............................................................................................................... 7
Product Description...............................................................................................................................7
3 Hardware Overview..................................................................................................9
Internal Ports......................................................................................................................................... 9
Front Panel.............................................................................................................................................9
Port Numbering.....................................................................................................................................9
USB Console Port..................................................................................................................................9
System Status.......................................................................................................................................10
4 Installation................................................................................................................13
Unpacking the Aggregator..................................................................................................................13
Unpacking Steps.................................................................................................................................. 13
5 Installing and Configuring the Aggregator...................................................... 15
Installing a switch in a Dell PowerEdge FX2 Server Chassis.............................................................. 16
Connecting a Console Terminal.........................................................................................................16
Invoking the X-Loader and U-Boot CLIs............................................................................................ 17
Reconfiguring Default Settings........................................................................................................... 17
Before You Start.............................................................................................................................17
Reconfiguration Using the CMC Interface................................................................................... 18
Reconfiguration Using the CLI......................................................................................................18
Aggregator Auto-Configuration......................................................................................................... 19
Data Center Bridging Support...................................................................................................... 20
FCoE Connectivity........................................................................................................................ 20
iSCSI Operation............................................................................................................................. 20
Link Aggregation........................................................................................................................... 20
Link Tracking................................................................................................................................. 20
Configuring VLANs.............................................................................................................................. 21
Uplink LAG......................................................................................................................................21
Server-Facing LAGs....................................................................................................................... 21
Mode Transitions........................................................................................................................... 21
6 Assembling a VLT....................................................................................................23
Cabling the VLT...................................................................................................................................23
Configuring and Bringing Up a VLT....................................................................................................23
7 Programmable-MUX Mode.................................................................................. 25
Configuring and Bringing Up the Programmable-MUX Mode..........................................................25
8 Next Steps.................................................................................................................27
9 Technical Specifications.......................................................................................29
1

About this Guide

This document helps you in getting started with Dell PowerEdge FN 410S I/O Aggregator. For complete installation and configuration information, refer to the documents listed below:
Table 1. Dell PowerEdge FN 410S I/O Aggregator Documents
Information Documentation
Hardware installation and power-up instructions Installing the Dell PowerEdge FN 410S I/O Aggregator
Software configuration Dell Networking Operating System (OS) Configuration
Guide for the Dell PowerEdge FN 410S I/O Aggregator
Command line interface Dell Networking OS Command Line Reference Guide
for the Dell PowerEdge FN 410S I/O Aggregator
Latest updates Dell Networking OS Release Notes for the Dell
PowerEdge FN 410S I/O Aggregator
About this Guide
5
6
2

Introduction

This document provides basic information about the Dell PowerEdge FN 410S I/O Aggregator, including how to install and perform the initial configuration. This document assumes the Dell PowerEdge FX2 server chassis is installed correctly. For the complete installation instructions, refer to the Dell PowerEdge FX2 server chassis Installation Guide .
For information about how to configure and monitor switch features, refer to the Configuration Guide for the Dell PowerEdge FN 410S I/O Aggregator, which is available on the Dell Support website at http://
www.dell.com/support/manuals.

Product Description

The aggregator is a multi layer, 12x10Gigabit Ethernet switch that operates in a Dell PowerEdge FX2 server chassis, which can support up to eight servers and two aggregator switches with four uplink interfaces each.
The Dell PowerEdge FX2 server chassis is managed by a single chassis management controller (CMC), which is similar to the CMC unit on the Dell PowerEdge M1000e and provides management connectivity to two I/O Modules and the iDRAC units of all eight servers.
Introduction
7
8
3

Hardware Overview

This section contains information about input/output aggregator (IOA) characteristics and modular hardware configurations.

Internal Ports

The aggregator provides 8x10 Gigabit Ethernet internal ports. The internal ports are connected to server through the Dell PowerEdge FX2 server chassis midplane.
The aggregator also provides an internal Ethernet interface—the out-of-band (OOB) interface, which is dedicated to switch management traffic on this port, and is segregated from operational network traffic on the switch ports and cannot be switched or routed to the operational network.

Front Panel

The following figure shows the aggregator front panel.
Figure 1. I/O Aggregator Front Panel

Port Numbering

When installed in a server enclosure, the Dell PowerEdge FN 410S I/O Aggregator ports are numbered from 1 to 12. Ports from 1 to 8 are internal server-facing ports. Ports from 9 to 12 are external ports numbered from left to right on the switch.
To configure a port, specify the slot (from 0 to 5; default: 0) and port number (from 1 to 12) in the interface port-type slot/port command, where slot is the unit number of the aggregator displayed in the
Dell(conf)# interface tengigabitethernet 0/4
show system brief command. For example:

USB Console Port

Use the upper USB console port to manage the switch through an RS-232 serial interface. This port provides a direct connection to the switch and allows you to access the command-line interface (CLI)
Hardware Overview
9
Loading...
+ 20 hidden pages