Statement of Volatility – Dell P2714T
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
The Dell P2714T contains both volatile and non-volatile (NV) components. Volatile components
lose their data immediately after power is removed from the component. Non-volatile (NV)
components continue to retain their data even after power is removed from the component.
The following NV components are present on the P2714T system board.
Table 1. List of Non-Volatile Components on System Board
Remedial Action
(Action necessary to
prevent loss of data)
Description
System EEPROM 24LC16B
16K bit, storage of system
setting(OSD)
VGA EDID EEPROM
24LC02B 2K bit, to store
VGA EDID
Reference
Designator
I312 Non-volatile No N/A
I305
Volatility
Description
Non-volatile
User Accessible
for external data
No N/A
DVI EDID EEPROM
24LC02B 2K bit, to store
HDMI EDID
Flash ROM MX25L4026EM
4M bit, to store firmware
CAUTION: All other components on the system board lose data if power is removed from the system.
Primary power loss (unplugging the power cord and removing the battery) destroys all user data on the
memory (DDR3, 1067 MHz). Secondary power loss (removing the on-board coin-cell battery) destroys
system data on the system configuration and time-of-day information.
______________
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright
and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or
other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective
companies.
I307, I308 Non Volatile No N/A
I311 Non Volatile No N/A
December 2014