Dell Force10 S50-01-GE-48T Installation Manual

Installing S50N and
S50V Systems
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not
followed.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Information in this publication is subject to change without notice. © 2010 Dell Force10. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™,
PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel
®
Xeon
, Core™ and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™, and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft Windows Server States and/or other countries. Red Hat Enterprise Linux and/or other countries. Novell
®
Oracle
is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware and vSphere
®
, MS-DOS® and Windows Vista® are either trademarks or registered trademarks of Microsoft Corporation in the United
®
is a registered trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries.
®
are registered trademarks or trademarks of VMWare, Inc. in the United States or other countries.
®
and Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States
®
, Virtual SMP®, vMotion®, vCenter®,
®
, Pentium®,
®
, Windows®,
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
November 2011 P/N 101-00059-03
Contents
1 About this Guide
Information Symbols and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 System Overview
Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
System Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LED Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Site Preparations
Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cabinet Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fans and Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
S50N-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
S50N and S50V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power over Ethernet (PoE) Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Storing Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 Installing the Switch
Inserting Optional Modules (10-Gigabit or Stacking) . . . . . . . . . . . . . . . . . . . . . . . . 17
Installing the System on a Tabletop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installing the System in a Rack or Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Two-Post Rack Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Four-Post Rack-mounting with Threaded Rails. . . . . . . . . . . . . . . . . . . . . . . . . 19
Four-Post Rack-mounting with Cage Nuts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Using SFTOS Stacking Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Using FTOS Stacking Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Connecting Stack Ports (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Supplying Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
S50N-DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5 Installing Backup Power
Backup Power Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Contents | 3
The Power Connections on the Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installing the Backup DC Power Supply for the S50V. . . . . . . . . . . . . . . . . . . . . . . . 30
Inserting Tandem S50V PSUs into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Connecting the S50V DC-to-DC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Installing the Backup DC Power Supply for the S50N . . . . . . . . . . . . . . . . . . . . . . . 34
DC Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Installing the External Power Shelf (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Inserting an S50N PSU into the EPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Connecting the DC-to-DC Cable for the S50N PSU . . . . . . . . . . . . . . . . . . . . . 37
6 Installing Ports
www.dell.com | support.dell.com
Accessing the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Connecting S50V Ethernet Ports with PoE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Installing Optics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Installing SFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Installing XFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7 Switch Specifications
Chassis Physical Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Environmental Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
AC Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
DC Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Safety Standards and Compliance Agency Certifications . . . . . . . . . . . . . . . . . 51
Electromagnetic Compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Product Recycling and Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
4 | Contents
8 Technical Support
The iSupport Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Accessing iSupport Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Contacting the Technical Assistance Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Locating Serial Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Requesting a Hardware Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Index
1

About this Guide

This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting the S50V or S50N switches (and related models, such as S50N-DC), inserting optional modules, and connecting to a power source. Except where noted, descriptions and instructions in this guide apply to all variants of these switches.
After you have completed the hardware installation and power-up of the switch, refer to the SFTOS™ Configuration Guide for software configuration information and to the SFTOS™ Command Reference for detailed Command Line Interface (CLI) information.

Information Symbols and Warnings

The following graphic symbols are used in this document to bring attention to hazards that exist when handling the switch and its components. Please read these alerts and heed their warnings and cautions.
Table 1-1
Table 1-1. Information Symbols
Symbol Warning Description
1
describes symbols contained in this guide.
Note This symbol informs you of important operational information.
Caution This symbol informs you that improper handling and installation could result in equipment
damage or loss of data.
Warning This symbol signals information about hardware handling that could result in injury.
WARNING: The installation of this equipment shall be performed by trained and qualified personnel only.
Read this guide before installing and powering up this equipment. This equipment contains two power cords. Disconnect both power cords before servicing.
WARNING: Class 1 laser product. Attention: Produit laser de classe 1 Warnung: Laserprodukt der Klasse
About this Guide | 5
WARNING: This equipment contains optical transceivers, which comply with the limits of Class 1 laser
radiation. Visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports when no cable is connected. Avoid exposure to laser radiation and do not stare into open apertures.
WARNING: Building Supply Notice for AC Power Supply Use. This product relies on the building's installation
for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors).
Attention: Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de
l'installation électrique du local. Vérifier qu'un fusible ou qu'un disjoncteur de 120 V alt., 15 A U.S. maximum (240 V alt., 10 A international) est utilisé sur les conducteurs de phase (conducteurs de charge).
Warnung: Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß- bzw.
Überstromschutz installiert ist. Stellen Sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehr als 240 V Wechselstrom, 10 A (bzw. in den USA 120 V Wechselstrom, 15 A) an den Phasenleitern (allen stromführenden Leitern) verwendet wird.
www.dell.com | support.dell.com
WARNING: Building Supply Notice for DC Power Supply Use. An external disconnect must be provided and
be easily accessible. Dell Force10 recommends the use of a 60A circuit breaker.
ATTENTION: Un interrupteur externe doit être fournis et doit être facilement accessible. Dell Force10
recommande l'utilisation d'un disjoncteur de 60Ampères.
WARNUNG: Eine leicht zugängliche Tren Dell Force10 nvorrichtung muss in der Verdrahtung eingebaut sein.
Dell Force10 empfiehlt einen 60A Sicherungsautomaten zu benutzen
CAUTION: Wear grounding wrist straps when handling this equipment to avoid ESD damage. CAUTION: Earthing (AKA grounding) connection essential before connecting supply. Always make the
ground connection first and disconnect it last.
CAUTION: Disposal of this equipment should be handled according to all national laws and regulations. See
Product Recycling and Disposal on page 52
CAUTION: This unit has more than one power supply connection; all connections must be removed to
.
remove all power from the unit.
ATTENTION: Cette unité est équipée de plusieurs raccordements d'alimentation. Pour supprimer tout courant
électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
WARNUNG: Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit
fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
CAUTION: Lithium Battery Notice. Danger of explosion if battery is replaced with incorrect type. Replace only
with the same type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
ACHTUNG - Explosionsgefahr wenn die Battery in umgekehrter Polarität eingesetzt wird. Nur miteinem
gleichen oder ähnlichen, vom Hersteller empfohlenen Typ, ersetzen. Verbrauchte Batterien müssen per den Instructionen des Herstellers verwertet werden.
ATTENTION - Il y a danger d'explosion s'il a remplacement incorrect de la batterie. Remplacer uniquement
avec une batterie du meme type ou d'un type equivalent recommande par le constructeur. Mettre au rebut les batteries usagees conformement aux instructions du fabricant.
NOTE: Other cautionary statements appear in context elsewhere in this book.
6 | About this Guide

Related Publications

The S50V or S50N (and related models, such as S50N-DC) can run on either FTOS or SFTOS. Depending on which software your system contains, refer to the following documents:
Table 1-2. Documentation
FTOS Documentation SFTOS Documentation
FTOS Configuration Guide for the S-Series SFTOS Configuration Guide FTOS Command Reference for the S-Series SFTOS Command Reference S-Series and FTOS Release Notes S-Series and SFTOS Release Notes
S25P Quick Reference
The Technical Documentation CD-ROM contains the S-Series hardware guides and the FTOS and SFTOS files listed above, respectively, except for the Release Notes. The CD-ROMs also have:
MIBs: Files for all SNMP MIBs supported by the software
Data sheets: Links to Dell Force10 product data sheets
NOTE: Documentation CD-ROMs do not have software. For the most recent documentation and software,
please visit iSupport (registration for access to some sections is required): http://www.force10networks.com/ CSPortal20/Main/SupportMain.aspx
NOTE: The iSupport website also has a section for S-Series techtips and FAQs.
About this Guide | 7
www.dell.com | support.dell.com
8 | About this Guide
2

System Overview

The S50V and S50N models of the Dell Force10 S-Series are stackable, Layer 2 switch/Layer 3 routers with 48 built-in 10/100/1000 Base-T ports, four SFP ports, and up to four optional 10-Gigabit (10GbE) ports (XFP or CX4), in two expansion slots.
Figure 2-1
the same layout; just the catalog number differs. The S50N-DC (see that DC1 and DC2 status LEDs appear where the AC and DC status LEDs are on the S50V and S50N.
Figure 2-1. The S50V Front View
Status Panel
LEDs
Stack ID Indicator LED
OK
AC
XFP49
XFP51
Alarm
DC
XFP51
XFP52
shows the front panel of the S50V. The S50N has
Figure 3-1 on page 15
Link/Active Indicator LEDs (SFP Ports 45-48)
Catalog # (S50-01-GE-48T-V)
) differs only in
Alarm
AC
DC
XFP49
P5251XFP50
Stack ID
RJ-45 Console Port
Ethernet Ports (10/100/1000)
Figure 2-2. The S50V Rear View
Label (Part #, Serial #, MAC Address, Bar Code, FRU #)
10-Gigabit Modules or Stacking Modules (optional). Optical ports numbered from left to right.
Ethernet Port Numbers 49 to 52, Right to Left
Ground Connector
Shared 10/100/1000 Ports (45-48)
DC Power
-48V
FG
-48V
RTN
S50-01-GE-48T-V
SFP Ports (45-48)
11.5
Current Sharing
AC Power Receptacle
fn00157s50V
fn00158s50V
The rear of the S50N differs only in that its DC terminal block has a different lug arrangement, as shown
Figure 3-1 on page 15
in
, while the S50N-DC replaces the AC receptacle with a second DC terminal
block.
System Overview | 9

Equipment

The following items are necessary to install the system:
The switch
At least one grounded AC or DC power source per S50V or S50N switch; one or two grounded DC power sources per S50N-DC switch.
Cable (included) to connect the AC power source to the switch
Brackets for rack installation (included)
Screws for rack installation (included) and #2 Phillips screwdriver (not supplied)
Other optional components are:
www.dell.com | support.dell.com
Stacking cables for connecting switches when stacked (not supplied). See Connecting Stack Ports
(optional) on page 25.
Backup DC Power Module (see Chapter
Optical networking components (see Chapter
Stacking components (see Ports
, below)
, Installing Backup Power, on page 29)
, Installing Ports, on page 41)

Features

Internal power supply with power redundancy from built-in 1+1 AC/DC (AC: 110v/220v auto-detect; DC: -48V standards-based with terminal-type connectors). The one difference between the S50V and S50N is that the S50V has built-in support for 360W Power over Ethernet (PoE) — IEEE 802.3af — with power allocation control available through the CLI.
256MB RAM and 32MB internal Flash memory
Supports up to 32000 MAC address entries, with hardware-assisted aging
Stackable switch features
19-inch rack-mountable and standard 1U chassis height
Six built-in fans with automatic speed adjustment for temperature changes
Supports 9252-byte jumbo frames in FTOS, 9216-byte jumbo frames in SFTOS
Back-pressure support at half-duplex, IEEE 802.3x flow control at full duplex
Extensive LED system with per-port LEDs

Ports

48 fixed 10/100/1000 Mbps auto-sensing and auto-MDIX RJ45 ports, up to 15.4W PoE each
Four ports capable of using 10/100/1000 Base-T or 1000 Base-X using auto-media detect
Console port (see Chapter Ethernet copper cable) and terminal adapter (DB-9 to RJ-45)
10 | System Overview
, Installing Ports, on page 41): Supplied with console cable (straight-through
Expansion slots that accept any combination of the following optional, high-capacity uplink modules: 10GbE XFP (two ports), 10GbE CX4 (two ports), 12G stacking (two ports) or 24G stacking (one port). See Inserting Optional Modules (10-Gigabit or Stacking) on page
17 and Connecting Stack Ports
(optional) on page 25.

System Status

Chassis status information can be derived in several ways, including physical LED displays and boot menu options, both discussed here, along with CLI those options, see the Command Reference and Configuration Guide for your software (FTOS or SFTOS).

LED Displays

show commands, and SNMP traps. For details on
As shown in
Figure 2-2 on page 9
, the front panel of the switch contains several sets of LEDs:
Stack ID: This is the LED at the far left of the front panel labeled “STACK ID”. See Stack ID in
T
able 2-2 on page 12). For more on stack unit numbering, see Stacking on page 23.
Status indicator LEDs on the left side of the front panel, to the right of the Stacking LED. See T
Each port has status indicator LEDs, described in T
Table 2-1. Port LED Displays
Feature Description
10/100/1000 Port LED* Speed LED (left side of each port)
Green — 1000M Amber — 100M Off — 10M Link/Active LED (right side of each port) Green — Link up on this port Blinking Green — Activity, transmitting or receiving packet at this port. Amber — Link up and power supplied on this port Off — No Link detected at this port
SFP Port LED* Link/Activity LED
Green — Link up on this port Blinking Green — Activity, transmitting or receiving packet in link up state Off — No Link detected at this port
XFP Port LED Link/Activity LED (Each XFP port has a status LED on the module and in the Status
Display at the left front of the switch) Green — Link up on this port Blinking Green — Activity, transmitting or receiving packet in link up state Off — No Link detected at this port
able 2-1.
able 2-2.
* The LEDs for a 10/100/1000 port numbered 45 through 48 are inactive if the shared SFP port (also labeled 45 through 48) is
enabled
.
System Overview | 11
NOTE: As suggested by the footnote above, the fiber SFP ports have priority over the four 10/100/1000 ports
with the same number.
The following table describes the LED status indicators on the left side of the front panel.
Table 2-2. Status Panel LED Display
Label LED Color Description
Left Side of the Status Panel OK Green
Off Green Blinking Amber
AC (on the S50V
www.dell.com | support.dell.com
and S50N) DC1 (on the
Green Amber Off
S50N-DC) XFP49* Green
Blinking Green Off
XFP50* Green
Blinking Green Off
STACK ID Green Indicates the stack ID (sometimes called "switch ID") of the unit.
Right Side of the Status Panel Alarm Amber
Red Off
DC (on the S50V and S50N)
DC2 (on the
Green Amber Off
S50N-DC) XFP51* Green
Blinking Green Off
XFP52* Green
Blinking Green Off
Unit is online. Unit is powered off. Unit is booting up. (blinking rate is 16 Hz) Error during boot-up.
Power supply is present and OK. Power supply is present but failed. Power supply is not present.
A valid 10G link is established on the port. Transmitting or receiving packets on the port. No link is established on the port.
A valid 10G link is established on the port. Transmitting or receiving packets on the port. No link is established on the port.
Starting with FTOS 7.8.1.0:
•“A” is displayed to the left of the stack ID if the unit is a standalone or
master (management) unit.
•“B” is displayed for a standby unit. (Actually, it’s an 8, because of the
limitations of the 7-segment LED.)
•“0” is displayed next to the stack ID, as before, for the other units.
Minor alarm: Fan or temperature is operating outside parameters. Major alarm No alarm
Power supply is present and OK. Power supply is present but failed. Power supply is not present.
A valid 10G link is established on the port. Transmitting or receiving packets on the port. No link is established on the port.
A valid 10G link is established on the port. Transmitting or receiving packets on the port. No link is established on the port.
*The four XFP LEDs on the front panel also indicate the status when CX4 ports are installed in the bay.
12 | System Overview

Site Preparations

This chapter describes requirements and procedures to install your system in the following topics:
Site Selection
Cabinet Placement on page 13
Rack Mounting on page 14
Fans and Airflow on page 14
Power on page 14
Storing Components on page 16
Tools Required on page 16
3
For detailed switch specifications, refer to
NOTE: Install the switch into a rack or cabinet before installing any optional components.
Chapter , Switch Specifications, on page 47
.

Site Selection

Make sure that the area where you install your switch meets the following safety requirements:
Near an adequate power source. Connect the system to the appropriate branch circuit protection as defined by your local electrical codes. See cautions in Information Symbols and
Environmental temperature between 32° – 122°F (0° – 50°C).
Relative humidity that does not exceed 85% non-condensing.
In a dry, clean, well-ventilated and temperature-controlled room, away from heat sources such as hot air vents or direct sunlight.
Away from sources of severe electromagnetic noise.
Positioned in a rack, cabinet, or on a desktop with adequate space in the front, rear, and sides of the unit for proper ventilation, and access.
Warnings on page 5.

Cabinet Placement

The cabinet must meet the following criteria:
Minimum cabinet size and airflow are according to the EIA standard.
Minimum of 5 inches (12.7 cm) between the side intake and exhaust vents and the cabinet wall.
Site Preparations | 13

Rack Mounting

When you prepare your equipment rack, ensure that the rack is earth ground. The equipment rack must be grounded to the same ground point used by the power service in your area. The ground path must be permanent.

Fans and Airflow

Ventilation is side-to-side, with six fans on the left side of the switch. For proper ventilation, position the switch in an equipment rack (or cabinet) with a minimum of five inches (12.7 cm) of clearance around the side intake and exhaust vents. When two S-Series systems are installed side by side, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow. The acceptable ambient temperature ranges are listed in
www.dell.com | support.dell.com
As listed in LED, which is green when the switch is operating within required temperature parameters and all components are operating normally, including fans. The LED is amber when the temperature or components are outside expected parameters, red in a major alarm.
The fan speed increases when the temperature reaches 72 degrees C, and decreases to normal speed when the temperature falls to 57 degrees C. The switch never intentionally stops managing traffic.
SFTOS logs a temperature warning message when a temperature of 77 degrees C is reached, and logs another message when the temperature returns to normal. The Command Line Interface (CLI) also reports an alarm.
Table 2-2 on page 12
Environmental Parameters on page 48
, the front panels of the S50N and S50V series have an Alarm status
.
Use the SFTOS Command Reference and SFTOS Configuration Guide.
In a stack, each unit has its own temperature monitoring and control. Status logging is identified by unit in the system log.
Fan replacement in the field is not offered as an option.
show logging command to see the log messages. For details, see the System Logs chapters of the

Power

S50N-DC

As shown below, the right side of the S50N-DC contains two terminal blocks for two 150W DC power supply inputs. The terminal blocks are labeled DC1 and DC2, which corresponds to the labels of the status LEDs on the front left of the switch. When both blocks are connected, they act in load-sharing mode with backup capability (one power supply can run the whole system).
14 | Site Preparations
Figure 3-1. The S50N-DC Rear View
Label (Part #, Serial #, MAC Address, Bar Code, FRU #)
10-Gigabit Modules or Stacking Modules (optional). Optical ports numbered from left to right.
Ethernet Port Numbers 49 to 52, Right to Left
Ground Connector
DC2
-48V RTN
-48V
-48V
FG
RTN
DC1
-48V
FG
fn00158s50N-DC

S50N and S50V

CAUTION: The power supply cord is used as the main disconnect device; ensure that the socket-outlet is
located/installed near the equipment and is easily accessible.
As shown in
Figure 2-2 on page 9
, the rear of the S50N and S50V models have both an auto-sensing 110/ 220V AC receptacle and a standard -48V terminal-type DC connector. The rear of an S50N differs only in the arrangement of the lugs on its DC terminal block
(Figure 3-1)
. Each system ships only with the AC power cord. There is no power switch. Connecting the switch to either an AC or DC power source starts the switch.
On both the S50N and S50V, either the AC or DC power supplies alone are sufficient to power the switch. When both AC and DC power supplies are connected, they act in roughly a 60%/40% load-sharing mode.
On the S50V, when the Dell Force10 470W DC Backup Power Supply is connected to the Current Sharing connection on the S50V DC terminal block, the switch uses the DC and AC power supplies in current-sharing (load-sharing plus additive) mode, so that the total capability is 470W+470W = 940W.
Backup Power Components on page 29
See
.
Dell Force10 also offers an external 180W DC power supply for the S50N and S50N-DC models, the same power supply used by the S50. However, the connections differ from those on the S50, so the power supply ships with DC cables to support each model. Rack-mounting hardware is supplied. For details on connecting to a power source, see
Supplying Power on page 27
.

Power over Ethernet (PoE) Support

Along with the optional DC power supply noted above, the S50V includes an internal 470W power supply that supports both the operation of the switch and an independent power distribution system to supply power to the 48 copper Ethernet ports, supporting the IEEE 802.3af standard for Power over Ethernet (PoE). Connect only powered devices that adhere to IEEE 802.3af.
Site Preparations | 15
The total PoE power budget for the switch is between 320W and 790W, depending on the power sources available. If the external 470W Redundant Power Supply (catalog # S50-01-PSU-V) from Dell Force10 is attached to the Current Sharing terminal (see use the
power-budget command in FTOS to convert the power supply to current-sharing mode to
Chapter , Installing Backup Power, on page 29
provide up to 790W of PoE. When running SFTOS, use the
inlinepower threshold command.
), you can
Each port can provide a maximum of 15.4W, subject to the power budget, voltage, power priority, and power limit settings. PoE is, by default, enabled globally on a first-come, first-serve basis, until it exceeds the total available power. Alternatively, the switch administrator can use the CLI to allocate power on a per-port and a per-stack-unit basis, with per-port power limits and port prioritization. For a brief introduction in this guide to the PoE commands, see
Connecting S50V Ethernet Ports with PoE on page 42
For details, see the PoE Commands sections in the Command Reference and Configuration Guide for your software.
www.dell.com | support.dell.com

Storing Components

If you do not install your system and components immediately, Dell Force10 recommends that you properly store the switch and all optional components until you are ready to install them.
WARNING: Electrostatic discharge (ESD) damage can occur when components are mishandled. Always
wear an ESD-preventive wrist or heel ground strap when handling the switch and its accessories. After you remove the original packaging, place the switch and its components on an antistatic surface.
.
Follow these storage guidelines:
Storage temperature should remain constant, in the range from -40° to 158° F (-40°C to 70° C).
Storage humidity should be within 10 to 90% (relative humidity), non-condensing
Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts.
Store in a dust-free environment.

Tools Required

S-Series switches are shipped fully assembled, encased in foam. A utility knife is useful for cutting the packing tape, and a Phillips #2 screwdriver is required for attaching rack screws, and is also used for making some attachments, including DC cables and rear cover plates. Wear an anti-static guard, as noted above.
16 | Site Preparations

Installing the Switch

To install S50V or S50N systems, Dell Force10 recommends that you complete the installation procedures in the order presented in this chapter:
Inserting Optional Modules (10-Gigabit or Stacking)
Installing the System on a Tabletop on page 18
4
Installing the System in a Rack or Cabinet on page
Stacking on page
Supplying Power on page 27
WARNING: As with all electrical devices of this type, take all the necessary safety precautions to prevent injury when
installing this system. Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the switch and its components. See other relevant cautions in the Preface.
23
19

Inserting Optional Modules (10-Gigabit or Stacking)

The S50V (catalog number S50-01-GE-48T-V) and S50N (catalog number S50-01-GE-48T-AC for AC­powered version of S50N; S50-01-GE-48T-DC for S50N-DC) have two expansion slots in the back of the chassis, for which there are four modules available:
Module Description Catalog Number
2-port 10GbE XFP (optical connection) S50-01-10GE-2P 2-port 10GbE CX4 (copper connection) S50-01-10GE-2C 2-port 12GbE Stacking S50-01-12G-2S 1-port 24GbE Stacking S50-01-24G-1S
The system supports any of the modules inserted in any combination of slots (although connecting all four ports of two 12G stacking modules is not supported, nor is connecting a 12G stack port in one switch to a 24G stack port in another switch). The ports are numbered 49 through 52, from left to right as you face the front of the chassis. So, for clarity in the use of the CLI in port assignment, if you are only using one XFP or CX4 module, insert it in the left-most expansion slot.
NOTE: The 10G modules cannot be used for stacking. See
page 25
.
Connecting Stack Ports (optional) on
Installing the Switch | 17
To install a module, follow the steps below:
f
Step Task
1 If the system is on, save the running configuration, if desired (and different from the startup configuration) with
the command write memory. Then power down the system by unplugging it from its power source.
CAUTION: Hot-swapping (inserting or removing) a module can crash and lock up the system, requiring a
power cycle.
2 Use a #2 Phillips screwdriver to remove either a module faceplate or an existing module. Note that these slots,
when used for 10G Ethernet ports, are assigned port numbers from left to right as you face the front of the system. So, for clarity in programming those ports, you might favor the left-most slot for the first 10G module that you install.
3 Grasp the module faceplate, and remove the module from its packaging, then slide it into the slot until the module
www.dell.com | support.dell.com
faceplate is flush with the rear cover of the system.
n00144s50V
4 Secure the captive screws on either side of the module. 5 The optical XFP 10-Gigabit module (Catalog # S50-01-10GE-2P) requires additional XFP transceiver inserts,
which are not included in the module kit. See
Installing XFPs on page 44
or the installation instructions that come
with the transceiver.
CAUTION: You can connect a CX4 cable to an XFP port through a CX4 XFP converter (catalog number
GP- XFP-1CX4) in the slot. However, an XFP port does not support the use of the cx4-cable-length command, discussed next.
CX4 module (catalog number S50-01-10GE-2C) ports do not require inserts. If you are installing a CX4 module, and you are connecting the ports with a cable substantially shorter or longer than 5 meters, use the cx4-cable­length command to set the signal strength. Use cx4-cable-length long for a longer cable, cx4-cable-length short for a shorter cable. For details when using FTOS, see the Interfaces chapter in the FTOS Command Reference. When using SFTOS, see the System Management Commands chapter in the SFTOS Command Reference for details.
NOTE: Take care not to connect CX4 ports to 12G stack ports in the switch. The receptacles and cables are
the same, but they are incompatible. CX4 ports are labeled as such; stack ports are not labeled. You can order several cable lengths of each type; they are not part of the module kit. For details, see Using CX4 Cables (CX4 Cable Matrix) in the S-Series tech tips on iSupport:
ToolTipsSSeries.aspx

Installing the System on a Tabletop

http://www.force10networks.com/CSPortal20/KnowledgeBase/
The system can be positioned on a stable tabletop. Four rubber standoffs are provided for that purpose in the plastic bag in the switch shipping box. Keep the following in mind when using a tabletop:
18 | Installing the Switch
Ensure that your tabletop is stable and can handle the weight of the switch or a stack of switches, if that is the case, along with any added backup power supplies.
Position the table for proper ventilation and easy access to separate power outlets for each device.

Installing the System in a Rack or Cabinet

The system provides three rack-mounting methods:
Two-Post Rack Mounting
Four-Post Rack-mounting with Threaded Rails
Four
-Post Rack-mounting with Cage Nuts

Two-Post Rack Mounting

The switch is shipped with the universal front-mounting brackets (rack ears) attached. Ensure that there is adequate clearance surrounding the rack to permit access and airflow. If you are installing two switches side-by-side, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow.
Position the chassis in the rack. Secure the chassis with two of the supplied screws through each bracket and onto the rack post.
Figure 4-1. Two-post (Front-mounted) Rack-mounting
fn00147as50V

Four-Post Rack-mounting with Threaded Rails

Ensure that there is adequate clearance surrounding the cabinet or rack to permit access and airflow. If you are installing two S-Series side-by-side, position the two units at least 5 inches (12.7 cm) apart to permit proper airflow. Follow the steps below to install a unit into a 4-post 19-inch equipment rack, using the attached front mounting brackets and the optional adjustable rear-mounting brackets.
Installing the Switch | 19
Step Task
V
1 Align the three screw holes of the adjustable rear mounting bracket with the three holes in the unit, and secure the
mounting bracket with three screws.
www.dell.com | support.dell.com
2 Insert the unit into the rack, and secure the chassis to the front post with two screws. Then secure it to the rear
posts with two screws.
fn00146s50
20 | Installing the Switch
fn00147s50V
Loading...