Dell FE200, FE100, FL100, FL200 User Manual

Dell™ PowerEdge™ Cluster FE100/FL100 and FE200/FL200
PLATFORM GUIDE
Guide des plates-formes
Plattform-Handbuch
Guía de plataforma
www.dell.com support.dell.com
Dell™ PowerEdge™ Cluster FE100/FL100 and FE200/FL200
PLATFORM GUIDE
www.dell.com support.dell.com
Throughout this guide, blocks of text may be accompanied by an icon and printed in bold type or in italic type. These blocks are notes, notices, cautions, and warnings, and they are used as follows:
NOTE: A NOTE indicates important information that helps you make better use of your computer system.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
WARNING: A WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious bodily injury.
____________________
Information in this document is subject to change without notice. © 2000-2001 Dell Computer Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell OpenManage, PowerEdge, and PowerVault are trademarks of Dell Computer Corporation; Microsoft, Windows, and Windows NT are regis­tered trademarks of Microsoft Corporation; Intel is a registered trademark of Intel Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation disclaims any propri­etary interest in trademarks and trade names other than its own.
April 2001 P/N 6C403 Rev. A02
Dell™ PowerEdge™ Cluster FE100/FL100 and FE200/FL200 Platform Guide
This guide provides the latest information on using Microsoft® Windows NT Server 4.0, Enterprise Edition operating system and Windows® 2000 Advanced Server operating system for the following Dell PowerEdge Cluster FE100/FL100 and FE200/FL200 products and components:
®
PowerEdge Cluster FE100
— Supported servers: PowerEdge 1550, 2400, 2450, 2550, 4300, 4350, 4400,
6100, 6300, 6350, 6400, 6450, and 8450
— Storage system: Dell PowerVault™ 65xF
®
— Cluster interconnect: Intel
a peripheral component interconnect (PCI) card or an integrated controller, if available
PRO/100+ Fast Ethernet controller, which can be
PowerEdge Cluster FL100
— Supported servers: PowerEdge 1550, 2400, 2450, 2550, 4300, 4350, 4400,
6100, 6300, 6350, 6400, 6450, and 8450
— Storage system: PowerVault 65xF
— Cluster interconnect: Giganet cluster local area network (cLAN) high perfor-
mance, low-latency host adapter
PowerEdge Cluster FE200
— Supported servers: PowerEdge 1550, 2400, 2450, 2550, 4300, 4350, 4400,
6300, 6350, 6400, 6450, and 8450
— Storage system: Dell PowerVault 660F/224F
— Cluster interconnect: Intel PRO/100+ Fast Ethernet controller, which can be
a PCI card or an integrated controller, if available
support.dell.com Dell PowerEdge Cluster Platform Guide 1-1
PowerEdge Cluster FL200
— Supported servers: PowerEdge 1550, 2400, 2450, 2550, 4300, 4350, 4400,
6300, 6350, 6400, 6450, and 8450
— Storage system: PowerVault 660F/224F
— Cluster interconnect: Giganet cLAN high performance, low-latency host
adapter
See the section related to your cluster product for more information on supported configurations. See also the Dell PowerEdge Cluster FE100/FL100 and FE200/FL200
Installation and Troubleshooting Guide for a detailed list of related documentation.
NOTE: Configurations not listed in this document are not certified or supported by Dell or Microsoft.
Windows NT 4.0 Server, Enterprise Edition
The PowerEdge Cluster FE100/FL100 and FE200/FL200 support clustering on Windows NT Server 4.0, Enterprise Edition. See the following sections for informa­tion on supported configurations and service packs. See also the Dell PowerEdge Cluster FE100/FL100 and FE200/FL200 Installation and Troubleshooting Guide for installation instructions for hardware configurations using Windows NT Server 4.0, Enterprise Edition.
PowerEdge Cluster FE100/FL100 and FE200/FL200 Homogeneous Configurations
Your PowerEdge Cluster FE100/FL100 and FE200/FL200 system supports the follow­ing PowerEdge servers as cluster nodes in homogeneous pairs (same server) on Windows NT 4.0, Enterprise Edition:
PowerEdge 1550-1550
PowerEdge 2400-2400
PowerEdge 2450-2450
PowerEdge 2550-2550
PowerEdge 4300-4300
PowerEdge 4350-4350
PowerEdge 4400-4400
PowerEdge 6300-6300
PowerEdge 6350-6350
PowerEdge 6400-6400
PowerEdge 6450-6450
PowerEdge 8450-8450
1-2 Dell PowerEdge Cluster Platform Guide
PowerEdge Cluster FE100/FL100 Heterogeneous Configurations
Your PowerEdge Cluster FE100/FL100 system supports the following PowerEdge servers as cluster nodes in heterogeneous pairs (mixed server models) with Windows NT 4.0, Enterprise Edition:
PowerEdge 2400-4300
PowerEdge 2450-4350
PowerEdge 4400-2400
PowerEdge 4400-4300
PowerEdge 6300-4300
PowerEdge 6300-6100
PowerEdge 6350-4350
PowerEdge 6400-4400
PowerEdge 6400-6300
PowerEdge 6450-6350
PowerEdge 8450-6350
PowerEdge 8450-6450
NOTES: Both nodes must be configured with identical operating systems and service packs, similar drivers (network interface controllers [NICs], Fibre Channel host bus adapter [HBAs], and so on), utilities (Dell OpenManage™ system management soft­ware, and so on), and Fibre Channel HBA basic input/output system (BIOS).
Heterogeneous server clusters (mixed server models) are not supported with PowerEdge Cluster FE200/FL200 configurations running Windows NT 4.0.
Both optical and copper HBA connectors are supported in a storage area network (SAN)-attached and SAN appliance-attached configuration. Copper HBA connectors are supported in a direct-attached configuration.
Support for QLogic HBAs on Windows NT
Table 1-1 lists the QLogic HBAs and the PowerEdge servers on which they are sup­ported for Windows NT cluster configurations. Table 1-2 lists the QLogic HBAs and the PowerEdge servers on which they are supported for Windows NT FE200/FL200 cluster configurations. For PCI slot recommendations, see the section for your server model on adding peripherals required for cluster nodes, found later in this document.
support.dell.com Dell PowerEdge Cluster Platform Guide 1-3
Table 1-1. QLogic HBAs Supported for FE100 and FL100 on Windows NT
QLogic HBA
s
QLogic HBA
s
QLogic HBA
s
PowerEdge Servers 1550 2400 2450 2550
QLA-2100/ 33-MHz
QLA-2200/
xx x x x xx
33-MHz
QLA-2200/
xx x x x x x x x
66-MHz
4300/ 4350 4400 6100
6300/ 6350
xxx
Table 1-2. QLogic HBAs Supported for FE200 and FL200 on Windows NT
QLogic HBA
s
QLogic HBA
s
PowerEdge Servers 1550 2400 2450 2550
QLA-2200/
xx xx x x x
33-MHz
QLA-2200/
xxxx x xx x x
66-MHz
4300/ 4350 4400
6300/ 6350
NOTE: All QLogic HBAs used in the cluster nodes must be the same model within the cluster.
The supported drivers for the QLogic HBAs in Windows NT configurations are as follows:
6400/ 6450 8450
6400/ 6450 8450
For QLA-2100/ 33-MHz, version 7.05.08 or later
For QLA-2200/ 33-MHz, version 7.05.08 or later
For QLA-2200/ 66-MHz, version 7.05.08 or later
You can download the latest drivers from the Dell Web site at http://support.dell.com.
Windows NT 4.0 Service Pack Support
Windows NT Service Pack 6a or later is recommended for PowerEdge Cluster FE100/FL100 and FE200/FL200 systems.
1-4 Dell PowerEdge Cluster Platform Guide

Windows 2000 Advanced Server

The PowerEdge Cluster FE100/FL100 and FE200/FL200 support clustering on Windows 2000 Advanced Server. See the following sections for information on sup­ported configurations and service packs. See also the Dell PowerEdge Cluster FE100/FL100 and FE200/FL200 Installation and Troubleshooting Guide for installation instructions for hardware configurations using Windows 2000 Advanced Server.
PowerEdge Cluster FE100/FL100 and FE200/FL200 Homogeneous Configurations
Your PowerEdge Cluster FE100/FL100 and FE200/FL200 configuration supports the following PowerEdge servers as cluster nodes in homogeneous pairs (same server) with Windows 2000 Advanced Server:
PowerEdge 1550-1550
PowerEdge 2400-2400
PowerEdge 2450-2450
PowerEdge 2550-2550
PowerEdge 4300-4300
PowerEdge 4350-4350
PowerEdge 4400-4400
PowerEdge 6300-6300
PowerEdge 6350-6350
PowerEdge 6400-6400
PowerEdge 6450-6450
PowerEdge 8450-8450
NOTE: Heterogeneous server clusters (mixed server models) are not supported with PowerEdge Cluster FE100/FL100 and FE200/FL200 configurations running Windows 2000 Advanced Server.
Support for Qlogic HBAs on Windows 2000
Table 1-3 lists the QLogic HBAs and the PowerEdge servers on which they are sup­ported for Windows 2000 cluster configurations. Table 1-4 lists the QLogic HBAs and the PowerEdge servers on which they are supported for Windows 2000 FE200/FL200 cluster configurations. For PCI slot recommendations, see the section for your server model on adding peripherals required for cluster nodes, found later in this document.
support.dell.com Dell PowerEdge Cluster Platform Guide 1-5
Table 1-3. QLogic HBAs Supported for FE100/FL100 on Windows 2000
QLogic HBA
s
PowerEdge Servers 1550 2400 2450 2550
QLA-2100/ 33-MHz
QLA-2200/
xx x x x x x
4300/ 4350 4400
6300/ 6350
xx
33-MHz
QLA-2200/
xxxx xxx xx
66-MHz
Table 1-4. QLogic HBAs Supported for FE200/FL200 on Windows 2000
QLogic HBA
s
PowerEdge Servers 1550 2400 2450 2550
QLA-2200/
xx x x x x x
33-MHz
QLA-2200/
xxxx xxx xx
4300/ 4350 4400
6300/ 6350
66-MHz
NOTE: All QLogic HBAs used in the cluster nodes must be the same model.
The supported drivers for the QLogic HBAs in Windows 2000 configurations are as follows:
For QLA-2100/ 33-MHz, version 7.05.08 or later
For QLA-2200/ 33-MHz, version 7.05.08 or later
For QLA-2200/ 66-MHz, version 7.05.08 or later
You can download the latest drivers from the Dell Web site at
http://support.dell.com.
6400/ 6450 8450
6400/ 6450 8450
Windows 2000 Service Pack Support
Microsoft Windows 2000 Service Pack 1 or later is recommended for PowerEdge Cluster FE100/FL100 and FE200/FL200 systems.
1-6 Dell PowerEdge Cluster Platform Guide

Guidelines for Adding Peripherals for PowerEdge Cluster FE100/FL100 and FE200/FL200 Configurations

The following sections describe adding peripherals for PowerEdge 1550, 2400, 2450, 2550, 4300, 4350, 4400, 6100, 6300, 6350, and 8450 cluster nodes.
WARNING: Hardware installation should be performed only by trained service technicians. Before working inside the system, see the safety instructions in your PowerEdge System Information document to avoid a situation that could cause serious injury or death.
Peripherals for PowerEdge 1550 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses and HBAs.
PCI buses
— PCI bus 1: PCI slot 1 is 64-bit, 66 MHz
— PCI bus 2: PCI slot 2 is 64-bit, 66 MHz
HBAs
— You can install an HBA into any available PCI slot.
Peripherals for PowerEdge 2400 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the Dell OpenManage Remote Assistant Card 2 (DRAC 2).
PCI buses
— PCI bus 0: PCI slots 1 through 5 are 64-bit, 33-MHz.
— PCI bus 1: PCI slot 6 is 32-bit, 33-MHz.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 6.
support.dell.com Dell PowerEdge Cluster Platform Guide 1-7
Peripherals for PowerEdge 2450 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses and HBAs.
PCI buses
— PCI bus 0: PCI slots 1 through 3 are 32-bit, 33-MHz.
HBAs
— You can install HBAs in any available PCI slot.
Peripherals for PowerEdge 2550 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses.
PCI buses
— PCI bus 0: PCI slots 1 through 3 are 64-bit, 33-MHz.
HBAs
— You can install HBAs in any available PCI slot.
Peripherals for PowerEdge 4300/4350 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
PCI buses
— PCI bus 0: PCI slots 1 through 3 are 32-bit, 33-MHz slots.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 4.
Peripherals for PowerEdge 4400 Cluster Nodes
The following list provides PCI slot assignment information for the systems’s PCI buses, HBAs, and the DRAC 2.
PCI buses
— PCI bus 0: PCI slots 1 and 2 are 64-bit, 33/66-MHz.
— PCI bus 1: PCI slots 3 through 6 are 64-bit, 33-MHz.
— PCI bus 2: PCI slot 7 is 32-bit, 33-MHz.
1-8 Dell PowerEdge Cluster Platform Guide
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses (PCI buses 1 and 2) to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 7.
Peripherals for PowerEdge 6100 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses and HBAs.
PCI buses
— PCI bus 0: PCI slots 1 through 3 are 32-bit, 33-MHz slots.
— PCI bus 1: PCI slots 4 through 6 are 32-bit, 33-MHz slots.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses to balance the load on the system.
Peripherals for PowerEdge 6300 and 6350 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
PCI buses
— PCI bus 0: PCI slots 1 through 3 are 32-bit, 33-MHz.
— PCI bus 1: PCI slots 4 through 7 are 64-bit, 33-MHz.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 3.
support.dell.com Dell PowerEdge Cluster Platform Guide 1-9
Peripherals for PowerEdge 6400 and 6450 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses, HBAs, and the DRAC 2.
PCI buses
— PCI bus 0: PCI slot 1 is 32-bit, 33-MHz.
— PCI bus 1: PCI slots 2 through 5 are 64-bit, 33-MHz.
— PCI bus 2: PCI slots 6 and 7 are 64-bit, 33/66-MHz.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses (PCI buses 1 and 2) to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 1.
Peripherals for PowerEdge 8450 Cluster Nodes
The following list provides PCI slot assignment information for the system’s PCI buses, RAID controllers, HBAs, and the DRAC 2.
PCI buses
— PCI bus 0: PCI slot 1 and 2 are 64-bit, 33-MHz.
— PCI bus 1: PCI slots 3 through 6 are 64-bit, 33-MHz.
— PCI bus 2: PCI slots 7 and 8 are 64-bit, 33/66-MHz.
— PCI bus 3: PCI slots 9 and 10 are 64-bit, 33/66-MHz.
RAID controllers
— Install the RAID controller for the server’s internal drives in PCI slot 1.
HBAs
— For dual HBA configurations, Dell recommends installing the HBAs on sepa-
rate PCI buses (PCI buses 2 and 3) to balance the load on the system.
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 2.
1-10 Dell PowerEdge Cluster Platform Guide
Dell™ PowerEdge™ Cluster FE100/FL100 et FE200/FL200
GUIDE DES PLATES-FORMES
www.dell.com support.dell.com
Remarques, avis, précautions et avertissements
Dans ce guide, certains blocs de texte sont accompagnés d'une icône et imprimés en caractères gras ou en italique. Ces blocs sont des remarques, des avis, des précau­tions et des avertissements utilisés comme suit :
REMARQUE : Une REMARQUE indique des informations importantes qui vous aident à utiliser votre système informatique au mieux.
AVIS : Un AVIS vous avertit d’un risque de dommage matériel ou de perte de données et vous indique comment éviter le problème.
PRÉCAUTION : Une PRÉCAUTION vous avertit d’une situation qui, si elle n'est pas évitée, peut entraîner des blessures plus ou moins graves.
AVERTISSEMENT : Un AVERTISSEMENT vous avertit d’une situation qui, si elle n'est pas évitée, peut provoquer la mort ou des blessures sérieuses.
____________________
Les informations contenues dans ce document sont sujettes à modification sans préavis. © 2000-2001 Dell Computer Corporation. Tous droits réservés.
Toute reproduction, sous quelque forme que ce soit, sans l'autorisation écrite de Dell Computer Corporation, est strictement interdite.
Marques utilisées dans ce texte†: Dell, le logo DELL, Dell O penManage, PowerEdge et PowerVault sont des marques de Dell Computer Corporation ; Microsoft, Windows et Windows NT sont des marques déposées de Microsoft Corporation ; Intel est une marque déposée de Intel Corporation.
D'autres marques et noms commerciaux peuvent être utilisés dans ce document pour faire réfé­rence aux entités se réclamant de ces marques et de ces noms ou à leurs produits. Dell Computer Corporation dénie tout intérêt propriétaire vis-à-vis des marques et des noms commerciaux autres que les siens.
Avril 2001 P/N 6C403 Rév. A02

Guide des plates-formes Dell™ PowerEdge™ Cluster FE100/FL100 et FE200/FL200

Ce guide présente les informations les plus récentes concernant l'utilisation du sys­tème d'exploitation Microsoft système d'exploitation Windows sants Dell PowerEdge Cluster FE100/FL100 et FE200/FL200 suivants :
®
Windows NT® Server 4.0, Enterprise Edition et du
®
2000 Advanced Server pour les produits et compo-
PowerEdge Cluster FE100
— Serveurs pris en charge : PowerEdge 1550, 2400, 2450, 2550, 4300, 4350,
4400, 6100, 6300, 6350, 6400, 6450 et 8450
— Système de stockage : Dell PowerVault™ 65xF
®
— Interconnexion de clusters : Contrôleur Intel
vant être une carte PCI (Peripheral Component Interconnect [interconnexion de composants périphériques]) ou un contrôleur intégré, si celui-ci est disponible
PRO/100+ Fast Ethernet, pou-
PowerEdge Cluster FL100
— Serveurs pris en charge : PowerEdge 1550, 2400, 2450, 2550, 4300, 4350,
4400, 6100, 6300, 6350, 6400, 6450 et 8450
— Système de stockage : PowerVault 65xF
— Interconnexion de clusters : Adaptateur à l'hôte à faible latence et à hautes
performances, en réseau cLAN (cluster Local Area Network [cluster de réseau local]) Giganet
PowerEdge Cluster FE200
— Serveurs pris en charge : PowerEdge 1550, 2400, 2450, 2550, 4300, 4350,
4400, 6300, 6350, 6400, 6450 et 8450
— Système de stockage : Dell PowerVault 660F/224F
— Interconnexion de clusters : Contrôleur Intel PRO/100+ Fast Ethernet, pou-
vant être une carte PCI ou un contrôleur intégré, si celui-ci est disponible
support.dell.com Guide des plates-formes Dell PowerEdge Cluster 2-1
Loading...
+ 39 hidden pages