Delfield N8631 User Manual

Short Form Specifications
NOTE: NOT TO SCALE
22"
55.9cm
12.75"
32.4cm
3"/7.6cm
2.37"
6.1cm
18"
45.7cm
25.87"
65.70cm
A
A – 4"
A – 10.2cm
NOTE: NOT TO SCALE
A – 8"
A – 20.3cm
NOTE: NOT TO SCALE
21"
53.3cm
RIGHT END VIEW
N8200 MODELS
PLAN VIEW
N8200 MODELS
ELEVATION VIEW
N8200 MODELS
1" (2.54CM)
Top is one-piece, 18-gauge stainless steel. Top has a drain trough and 2” (5.1cm) overhang around perimeter. Top is elevated 1.68” (2.5cm) above counter surface. Underside of frost top is sealed with refrigeration lines and insulated with high-density, closed-cell polyurethane. Exterior housing is 22-gauge galvanized steel.
Condensing unit is suspended below the frost top on a 16-gauge steel frame. Condensing unit uses HFC-404a refrigerant. Unit has an ON/OFF toggle switch, an 8’ (2.4m) cord and NEMA 5-15 plug. Unit has (1) stainless steel louver provided for field installation; cutout dimensions are 12” x 23.5” (30.5cm x 59.7cm). A second opening at the rear of the cabinet is provided at installation to allow for proper air circulation.
Optional Accessories and Modifications
• Single or double service flip-up sneezeguards
• Relocate compressor
• *220V/50 cycle electrical system
* Inclusion of this option will alter electrical specifications of the
unit.
PROJECT _____________________________________
ITEM NUMBER_________________________________
QUANTITY _______________ DATE________________
APPROVAL____________________________________
N8200
Drop-In Self-Contained Frost Top
Model N8259
Mechanical Data–Standard Unit
MODEL COUNTER CUTOUT VOLTS/HERTZ/ SHIP
NUMBER A DIMENSIONS PHASE H.P. AMPS WEIGHT
N8231 31.75" (80.6cm)
N8245
N8259
N8273
N8287
The Delfield Company, 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. ©2003 The Delfield Company. All rights reserved. Printed in U.S.A.
45.62” (115.9cm) 44.63” x 25” (113.3cm x 63.5cm) 115/60/1 1/4 7.0 185 lbs/ 83 kg
31.00” x 25" (78.1cm x 63.5cm) 115/60/1 1/4 7.0 170 lbs/ 77 kg
59.5” (151.1cm) 58.50” x 25” (148.59cm x 63.5cm) 115/60/1 1/4 7.0 213 lbs/ 96 kg
73.37" (186.4m) 72.38” x 25” (183.84cm x 63.5cm) 115/60/1 1/3 8.0 218 lbs/ 98 kg
87.25" (221.6cm) 86.25" x 25" (219.07cm x 63.5cm) 115/60/1 1/3 8.0 224 lbs/ 101 kg
19.87"
50.5cm
24.5"
62.23cm 26"
65.71cm
A
A – 1.37"
A – 3.48cm
A – 6"
A – 15.2cm
C
L
8"/20.3cm
B
NOTE: NOT TO SCALE
NOTE: NOT TO SCALE
8"
20.3cm
11"
27.9cm
19.18"
48.7cm
11.25"
28.6cm
NOTE: NOT TO SCALE
DRAIN IS 8.00"/20.3 cm FROM END OF BODY; POSITION RELATIVE TO CENTER LINE VARIES WITH LENGTH OF MODEL
16.37"
41.6cm
CONTROL PANEL CUTOUT DIMENSIONS:
4.25" x 12.25" (10.8cm x 31.1cm)
PLAN VIEW
8600 MODELS
ELEVATION VIEW
8600 MODELS
RIGHT END VIEW
8600 MODELS
PROJECT _____________________________________
ITEM NUMBER_________________________________
QUANTITY _______________ DATE________________
APPROVAL____________________________________
Drop-In Self-Contained Electric Hot & Cold Pans
Short Form Specifications
Top and well are one-piece 18-gauge stainless steel. Top has .68”
(4.26cm) overhang around perimeter. Well is 8” (20.3cm) deep and creased to a 1” (2.5cm) diameter drain. Unit is provided with adapter bars to allow placement of 12” 20 (30.5cm x 50.8cm) pans. Sides are wrapped with refrigeration lines and insulated with 1” (2.5cm) of blanket insulation. Exterior housing is 20-gauge galvanized steel.
Condensing unit is suspended below the well on a 16-gauge steel frame. Condensing unit uses HFC-134a refrigerant. Unit has a single temperature control and a three-way toggle switch provided in a control panel for mounting in a counter or at a remote location. Unit has a three-wire electrical junction box mounted to the underside of the unit. Unit must be hard-wired at installation. Unit has one stainless steel louver provided for field installation; cutout dimensions for louvers is 12” x 23.5” (30.5cm x 59.7cm)
Optional Accessories and Modifications
• Adapter plates and bars
• Single or double service flip-up sneezeguards
• Relocate compressor
• Telescoping cover
• *220V/50 cycle electrical system * Inclusion of this option will alter electrical specifications of the
unit.
N8600
Model N8645
pans by others
NOTE: Drain is located on left if facing service side.
Mechanical Data–Standard Unit
MODEL COUNTER CUTOUT VOLTS/HERTZ/ SHIP
NUMBER A B DIMENSIONS PHASE H.P. AMPS WEIGHT
N8631
N8645
N8659
N8673
N8687
The Delfield Company, 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com
Delfield reserves the right to make changes in design or specifications without prior notice. ©2003 The Delfield Company. All rights reserved. Printed in U.S.A.
31.75” (80.6cm) 5.91” (15cm) 30.75” X 25” (78.10cm x 63.5cm) 115/60/1 1/5 17.0 179 lbs/ 81 kg
45.62” (115.9cm) 12.84” (32.6cm) 44.62” x 25” (113.36cm x 63.5cm) 120/208/230 1/5 17.0 212 lbs/ 95 kg
59.5” (151.1cm) 19.78” (50.2cm) 58.5” x 25” (148.6cm x 63.5cm) 120/208/230 1/4 22.0 252 lbs/ 113 kg
73.37” (186.4cm) 26.71” (67.8cm) 72.38” x 25” (183.84cm x 63.5cm) 120/208/230 1/4 28.0 266 lbs/ 102 kg
87.25 (221.6cm) 33.65” (85.5cm) 86.25” x 25” (219.07cm x 63.5cm) 120/208/230 1/3 33.0 303 lbs/ 136 kg
DS82_8600 04/03